1000 resultados para Água - desinfecção


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The treatment of wastewater is essential to human health. One of the most important steps is the disinfection treatment which uses chlorine to eliminate bacteria as required by environmental agencies. However, the identification of potentially toxic byproducts generated by this method, such as trihalomethanes, has stimulated the development of new alternative disinfection technologies. Among them, heterogeneous photocatalysis, TiO2 photocatalysis and electrochemical disinfection are considered suitable alternatives to the chlorination method. Thus, the present dissertation analyzes the evolution of active chlorine species in a synthetic NaCl solution and it is tested to treat a synthetic solution of the dye Reactive Blue 19 using boron-doped diamond (BDD) and ruthenium oxide (Ti/Ru0.3Ti0.7O2) as anodes. The indirect electrochemical process was discussed in terms of mineralization of the total organic load and percentage of color removal in order to evaluate the applicability of electrochemical technology. Electrochemical experiments were carried out with different current densities (25, 50 and 75 mA.cm-2) during 120 minutes. On the other hand, other important parameter in this study was the influence of the proportion sp3/sp2 on BDD anode on the performance of the evolution of active chlorine species which was investigated by electrolytic techniques (linear polarization), with the intention of determining the related training oxidizing species and consumption energy to chemical or electrochemical reactions. From the results, it can be noted that the BDD electrode showed better efficiency throughout the electrochemical process.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The treatment of wastewater is essential to human health. One of the most important steps is the disinfection treatment which uses chlorine to eliminate bacteria as required by environmental agencies. However, the identification of potentially toxic byproducts generated by this method, such as trihalomethanes, has stimulated the development of new alternative disinfection technologies. Among them, heterogeneous photocatalysis, TiO2 photocatalysis and electrochemical disinfection are considered suitable alternatives to the chlorination method. Thus, the present dissertation analyzes the evolution of active chlorine species in a synthetic NaCl solution and it is tested to treat a synthetic solution of the dye Reactive Blue 19 using boron-doped diamond (BDD) and ruthenium oxide (Ti/Ru0.3Ti0.7O2) as anodes. The indirect electrochemical process was discussed in terms of mineralization of the total organic load and percentage of color removal in order to evaluate the applicability of electrochemical technology. Electrochemical experiments were carried out with different current densities (25, 50 and 75 mA.cm-2) during 120 minutes. On the other hand, other important parameter in this study was the influence of the proportion sp3/sp2 on BDD anode on the performance of the evolution of active chlorine species which was investigated by electrolytic techniques (linear polarization), with the intention of determining the related training oxidizing species and consumption energy to chemical or electrochemical reactions. From the results, it can be noted that the BDD electrode showed better efficiency throughout the electrochemical process.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A dessalinização da água do mar é um método usado para obter água potável. Na dessalinização da água também é necessária a desinfecção de água com o cloro. Esta desinfecção garante à água condições seguras em termos microbiológicos mas promove a formação de novas substâncias consideradas tóxicas, resultantes da reacção do cloro com a matéria orgânica presente na água. Essas substâncias são designados por subprodutos de desinfecção de água com o cloro (DBP) dos quais destacam-se os trihalometanos (THM), os ácidos haloacéticos (HAA), os haloacetonitrilos (HAN), as haloacetonas (HK). A concentração dessas substâncias em águas para consumo humano é muito baixa e constitui sempre um desafio a sua detecção e quantificação. Neste trabalho desenvolveu-se e optimizou-se métodos de análises de DBP em água para consumo humano. Os DBP voláteis foram analisados por headspace e cromatografia gasosa com detecção por captura electrónica (HS-GC-ECD) e por microextracção em fase sólida no headspace e cromatografia gasosa com detecção por captura electrónica (SPME-HS-GC-ECD). Para os DBP não voláteis (HAA) aplicou-se a extracção em fase sólida e cromatografia líquida com detector de fila de diodos (SPE-RPHPLC- DAD). Foram analisados os DBP na água dessalinizada por osmose inversa proveniente de Cabo Verde e na água da cidade de Porto, de forma a verificar as diferenças em termos qualitativos e quantitativos. Usou-se um planeamento factorial de Box-Behnken para a optimização de métodos analíticos. Este modelo foi igualmente aplicado na simulação laboratorial de dessalinização da água do mar por osmose inversa e desinfecção com o cloro, tendo como objectivo identificar os factores mais significativos na formação de DBP em água dessalinizada (pH, temperatura e tempo de desinfecção).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Este trabalho de pesquisa foi desenvolvido com o objetivo de verificar a eficácia de diferentes concentrações de cloro utilizadas como agente sanitizante na água de lavagem de alface(Lactuca sativa L.), do tipo americana, minimamente processada. Na matéria-prima foram realizadas contagens de bolores, leveduras e coliformes totais. No produto final foram realizadas contagens de bolores e leveduras, coliformes totais e avaliação sensorial. O processamento mínimo da alface compreendeu as seguintes etapas: corte do talo, desfolhamento da cabeça, primeira seleção, primeira lavagem, segunda seleção, corte em tiras, segunda lavagem, tratamento de imersão em soluções contendo 70, 100 e 130mg/L de cloro, centrifugação, acondicionamento em sacos plásticos e armazenamento a 2°C e a 20°C. Os resultados mostraram que a imersão em solução contendo 70mg/L de cloro confere a alface minimamente processada uma vida-útil de seis dias e em solução contendo 100 e 130mg/L, nove dias e que o seu aroma, textura e gosto não foram afetados por estes tratamentos.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Brazil has vast amounts of hydric resources, whose quality has been deteriorating due to pollutant dumping. Household waste disposal is one of the main sources of water pollution, stimulating bacteria proliferation and introducing microorganisms, including those from fecal matter. Conventional water disinfection methods are a solution, but on the downside, they lead to the formation byproducts hazardous to human health. In this study, aiming to develop bactericidal filters for the disinfection of drinking water; silver nanoparticles were deposited on alumina foams through three routes: sputtering DC, dip coating and in situ chemical reduction of silver nitrate. The depositions were characterized through X-ray diffraction, scanning electron microscopy and EDS element mapping. The influence of the depositions on permeability and mechanical properties of the ceramic foams was assessed and, in sequence, a preliminary antibacterial efficiency analysis was carried out. Characterization results indicate that the chemical reduction routes were efficient in depositing homogeneously distributed silver particles and that the concentration of the metallic precursor salt affects size and morphology of the particles. The antibacterial efficiency analysis indicates that the chemical reduction filters have potential for water disinfection

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The use of solar energy for water disinfection, and is accessible to disadvantaged communities because of its low cost, has the advantage of using disposable materials such as bottles of polyethylene terephthalate (PET). We present a study that used two methods of disinfection: the methodology proposed by the project Solar Water Disinfection (SODIS), which consisted of water disinfection by solar radiation and temperature and the methodology which the temperature of the water for disinfection. In both, we seek to eliminate microorganisms that cause serious diseases such as dysentery, typhoid, cholera, etc. Water samples were collected in the community of Bass, where the population has low income and the incidence of waterborne diseases is high. The experiments were divided into two stages. In step 1 we studied the feasibility of disinfection and in step 2 the feasibility of the pilot plant to obtain adequate levels of disinfection temperatures desired. The results showed the efficiency of the disinfection process, reaching an average of 80 to 100% death of microorganisms, but regrowth was observed in some samples. Finally on the good results of stage 1, is designed and built and tested in an experimental pilot plant, which has shown to be feasible to promote water disinfection through the use of solar energy. The water after treatment is in accordance with the limits established by Brazilian legislation for clean water, maintaining a positive performance for the disinfection and acceptable levels of bacterial regrowth

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Brazil has vast amounts of hydric resources, whose quality has been deteriorating due to pollutant dumping. Household waste disposal is one of the main sources of water pollution, stimulating bacteria proliferation and introducing microorganisms, including those from fecal matter. Conventional water disinfection methods are a solution, but on the downside, they lead to the formation byproducts hazardous to human health. In this study, aiming to develop bactericidal filters for the disinfection of drinking water; silver nanoparticles were deposited on alumina foams through three routes: sputtering DC, dip coating and in situ chemical reduction of silver nitrate. The depositions were characterized through X-ray diffraction, scanning electron microscopy and EDS element mapping. The influence of the depositions on permeability and mechanical properties of the ceramic foams was assessed and, in sequence, a preliminary antibacterial efficiency analysis was carried out. Characterization results indicate that the chemical reduction routes were efficient in depositing homogeneously distributed silver particles and that the concentration of the metallic precursor salt affects size and morphology of the particles. The antibacterial efficiency analysis indicates that the chemical reduction filters have potential for water disinfection

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Este trabalho teve por objetivo monitorar a qualidade microbiológica e identificar fatores de interferência na contaminação da água de consumo de creches de um município da região oeste de São Paulo. Colheram -se 24 amostras de água tratada em 24 pontos de 11 creches, no centro e periferia de um município da região oeste de São Paulo, durante junho e julho de 2005. De cada amostra pesquisaram-se coliformes totais e Escherichia Coli. Verificou-se que nenhuma das amostras indicou presença de Escherichia Coli, nem coliformes totais. Setenta e três por cento das creches possuíam filtros de água; 64%, utilizavam água dos refeitórios para dessedentação e água das cozinhas no preparo das refeições, mamadeiras, hidratação, lavagem e desinfecção de vegetais, higiene do ambiente, utensílios e equipamentos; apenas 27% das creches transportavam água dos refeitórios e de outras áreas para a cozinha para o preparo das mamadeiras e hidratação e 9% das creches empregavam apenas água da cozinha, tanto para preparação de alimentos quanto dessedentação das crianças. Em 46% das creches a última limpeza e desinfecção dos reservatórios havia sido realizada há seis meses, em 18% há sete meses, em 9% há doze meses e 27% há mais de 12 meses. Com relação aos encanamentos, 73% das creches possuíam encanamentos de PVC (policloreto de vinila) e 27% de ferro. Concluiu-se que é fundamental o monitoramento periódico da potabilidade da água de uso nas creches; há necessidade de se implementar o procedimento de higienização dos reservatórios de água nas creches alvo deste estudo

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O volume de águas residuais tratadas tem vindo a aumentar nos últimos anos devido ao cumprimento da legislação em vigor – visando a proteção dos meios recetores das cargas poluentes rejeitas pelos aglomerados urbanos e industriais. A maioria das estações de tratamento de águas residuais é projetada para reduzir a carga poluente de natureza química, não removendo de forma significativa a contaminação por microrganismos patogénicos. Determinados usos dos meios recetores como a produção de água para consumo humano, águas balneares, águas para suporte de vida aquícola, bem como a reutilização dos efluentes das estações de tratamento de águas residuais para rega, entre outros, requerem a redução da carga de patogénicos, levando à inclusão de processos de desinfeção a montante da descarga. Na atualidade, o processo de desinfeção de águas residuais mais vantajoso na generalidade das situações é a radiação ultravioleta, em detrimento dos processos químicos anteriormente utilizados (como a utilização de cloro). Este trabalho pretende documentar o desempenho das instalações de desinfeção por radiação ultravioleta em Portugal, através da avaliação da eficiência de remoção de microrganismos indicadores de contaminação fecal (coliformes fecais) e dos fatores que a podem condicionar, como o teor de sólidos em suspensão, as caraterísticas dos equipamentos utilizados e suas condições de operação e manutenção. Tendo sido identificadas as estações de tratamento de águas residuais com desinfeção por radiação ultravioleta operacional em Portugal, foi possível efetuar a escolha de 9 delas para integrarem os casos de estudo, com base num questionário remetido às respetivas entidades gestoras. A eficiência do processo de desinfeção dos casos de estudo foi inferida através da comparação das concentrações de coliformes fecais no afluente à unidade de desinfeção e no efluente da estação de tratamento de águas residuais, a qual também permitiu efetuar uma análise relativa às diversas aptidões de reutilização da água residual tratada, à luz de diversos documentos legislativos e normativos, nacionais e europeus. Após a análise e processamento dos dados recolhidos dos casos de estudo, concluiu-se que todos eles apresentavam processos de desinfeção eficientes, com redução efetiva de coliformes fecais e que, a reduzida concentração de partículas em suspensão no afluente às unidades de desinfeção concorreu para o seu bom desempenho, evidenciando assim, a importância de o tratamento que precede a desinfeção assegurar a efetiva remoção de sólidos em suspensão até valores médios da ordem dos 14 mg/L.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mestrado em Engenharia Química

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A empresa Petibol, S.A. – Embalagens de plástico centra-se na produção de embalagens de plástico a partir da matéria-prima Poliestireno Expandido (EPS) e Polipropileno Expandido (EPP). A empresa possui uma preocupação ao nível da qualidade da água e do aproveitamento energético, tendo desta forma surgido a realização do estudo na unidade industrial, com o objectivo de anular e/ou diminuir as possíveis lacunas existentes na unidade industrial. Numa primeira etapa foi realizada uma caracterização global à qualidade da água e à empresa, actualizando-se os esquemas já existentes, contabilizando-se os custos actuais relativamente aos processos no circuito da água (arrefecimento, aquecimento e pressurização), e por fim, efectuou-se um levantamento in loco do circuito de água, relativamente à pressão, temperatura e caudal. Numa fase posterior, foram propostos equipamentos e processos, tendo em vista a colmatação dos problemas identificados, realizando-se um subsequente estudo relativamente aos custos inerentes a esses novos processos. A caracterização à água foi avaliada em diferentes pontos do circuito industrial, tendo-se determinado na Sala de Bombagem que o filtro de areia não possuía as dimensões mais apropriadas, existindo também um problema a nível mecânico associado ao processo de contra-lavagem. Tais factos podem ser a causa da ocorrência de um aumento do teor de sólidos após a passagem na camada filtrante. Relativamente ao amaciador, este deveria amaciar de forma completa a água para alimentação à caldeira, embora se tenha registado à saída do amaciador uma dureza de 21,3 mg/L, denunciando problemas na troca iónica. No que toca à água de alimentação à caldeira, verifica-se a existência de parâmetros que não se encontram de acordo com os critérios enunciados para uma óptima qualidade, sendo eles o pH (10,14), condutividade (363 μS/cm), teor de ferro (1,21 mg/L) e a dureza (16 mg/L). De salientar que somente o teor de cobre, que se encontra em quantidades vestigiais, apresenta-se de acordo com os valores impostos. No que respeita à água da caldeira, esta apresenta parâmetros incompatíveis com os recomendados, sendo eles a condutividade (7350 μS/cm), teor de sólidos dissolvidos (5248 mg/L) e alcalinidade total (780 mg/L). De referir que o valor de pH (11,8) não se encontra de acordo com a aplicação do tratamento “fosfato-pH coordenado”. Em relação aos parâmetros com valores que se encontram dentro dos limites, estes correspondem à dureza (0 mg/L), ao teor de fosfatos (45 mg/L) e teor de sílica (0 mg/L). A água do circuito de arrefecimento foi sujeita a uma análise microbiológica, que corroborou a presença de um biofilme. Um dos problemas enunciados pela empresa, prendia-se com a impossibilidade de descarga, no colector municipal, dos condensados dos compressores, visto apresentarem uma quantidade de óleo de cerca de 43,3 mg/L, equivalente a quatro vezes o valor limite de emissão, de acordo com a legislação municipal. Por fim, o efluente de descarga industrial apresenta um valor de pH (10,3) acima do intervalo permitido por lei (6,0 – 9,0), sendo que a corrente que mais contribui para este acréscimo de pH corresponde à corrente proveniente da água de purga, visto esta apresentar um valor de pH de 12,22. De maneira a contornar os parâmetros enunciados, é proposto a substituição do filtro de areia da Sala de Bombagem, assim como a inserção de um conjunto de medidas de remoção de ferro e desinfecção, sendo a conjugação de arejamento, coagulação, filtração e desinfecção, por parte do hipoclorito, a proposta apresentada. Aos condensados dos compressores é apresentado um sistema de separação, que possibilita a remoção do óleo da água, e uma consequente descarga da mesma. Actualmente, não existe qualquer filtro de areia no circuito de arrefecimento da água, sendo proposto assim esse equipamento, de forma a minorar o desenvolvimento da população microbiana, bem como a permitir uma maior eficiência na transferência de calor na torre de arrefecimento. Relativamente à descarga industrial, é recomendável a colocação de um sistema de regularização automática de pH. A inserção de uma válvula de três vias permite um aproveitamento energético e de água, a partir da confluência da água oriunda dos furos com a água do tanque de água fria, sendo posteriormente alimentada à central de vácuo. No estudo da recuperação energética, um outro equipamento avaliado correspondeu à serpentina, no entanto, verificou-se que a poupança no consumo de gás natural era de apenas 0,005%, o que não se mostrou uma proposta viável. O orçamento de todos os equipamentos é de 11.720,76 €, possibilitando não só um melhor funcionamento industrial, como um menor impacto a nível ambiental. Os custos futuros de funcionamento aumentam em 3,36%, tendo a pressurização um aumento do seu custo em 3,4% em relação ao custo actual, verificando-se um custo anual de 10.781,21€, em relação aos processos de arejamento, coagulação e desinfecção.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Tecnologia e Segurança Alimentar

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia do Ambiente, Perfil de Engenharia Sanitária