963 resultados para [HbA.sup.1c]
Resumo:
<p>Objective: The first aim of this study was to assess 25-hydroxy vitamin D (25OHD) concentrations in women with type 1 diabetes (T1DM) during pregnancy, post-delivery and also foetal (cord blood) 25OHD concentrations and to examine relationships between these. The second aim of the study was to investigate potential interactions between maternal body mass index (BMI) and foetal vitamin D status. A further study aim was to examine potential relationships between maternal 25OHD and glycosylated haemoglobin (HbA<sub>1csub>) throughout pregnancy.p><p>Research Design and Methods: This was an observational study of 52 pregnant controls without diabetes and 65 pregnant women with T1DM in a university teaching hospital. Maternal serum 25OHD was measured serially throughout the pregnancy and post-delivery. Cord blood 25OHD was measured at delivery. 25OHD was measured by liquid chromatography tandem mass spectrometry (LC-MS/MS).p><p>Results: Vitamin D deficiency (25OHD <25 nmol/L) was apparent in both the T1DM subjects and controls at all 3 pregnancy trimesters. Vitamin D levels in all cord blood were <50 nmol/L. Maternal 25OHD correlated positively with cord 25OHD at all 3 trimesters in the T1DM group (p= 0.02; p<0.001; p<0.001). 25OHD levels within cord blood were significantly lower for women with diabetes classified as obese vs. normal weight at booking [normal weight BMI <25 kg/m<sup>2sup> vs. obese BMI >30 kg/m<sup>2 sup>(nmol/L±SD); 19.93±11.15 vs. 13.73±4.74, p= 0.026]. In the T1DM group, HbA<sub>1csub> at booking was significantly negatively correlated with maternal 25OHD at all 3 trimesters (p= 0.004; p = 0.001; p= 0.05).p><p>Conclusion: In T1DM pregnancy, low vitamin D levels persist throughout gestation and post-delivery. Cord blood vitamin D levels correlate with those of the mother, and are significantly lower in obese women than in their normal weight counterparts. Maternal vitamin D levels exhibit a significant negative relationship with HbA<sub>1csub> levels, supporting a potential role for this vitamin in maintaining glycaemic control. p>
Resumo:
<p>In this work, an economical route based on hydrothermal and layer-by-layer (LBL) self-assembly processes has been developed to synthesize unique Al <sub>2sub>O<sub>3sub>-modified LiV<sub>3sub>O<sub>8sub> nanosheets, comprising a core of LiV<sub>3sub>O<sub>8sub> nanosheets and a thin Al <sub>2sub>O<sub>3sub> nanolayer. The thickness of the Al<sub>2sub>O <sub>3sub> nanolayer can be tuned by altering the LBL cycles. When evaluated for their lithium-storage properties, the 1 LBL Al<sub>2sub>O <sub>3sub>-modified LiV<sub>3sub>O<sub>8sub> nanosheets exhibit a high discharge capacity of 191 mA h g<sup>-1sup> at 300 mA g<sup>-1sup> (1C) over 200 cycles and excellent rate capability, demonstrating that enhanced physical and/or chemical properties can be achieved through proper surface modification. © 2014 Elsevier B.V. All rights reserved.p>
Resumo:
Glycated hemoglobin (HbA(1c)) is a `gold standard' biomarker for assessing the glycemic index of an individual. HbA(1c) is formed due to nonenzymatic glycosylation at N-terminal valine residue of the P-globin chain. Cation exchange based high performance liquid chromatography (CE HPLC) is mostly used to quantify HbA(1c), in blood sample. A few genetic variants of hemoglobin and post-translationally modified variants of hemoglobin interfere with CE HPLC-based quantification,. resulting in its false positive estimation. Using mass spectrometry, we analyzed a blood sample with abnormally high HbA(1c) (52.1%) in the CE HPLC method. The observed HbA(1c) did not corroborate the blood glucose level of the patient. A mass spectrometry based bottom up proteomics approach, intact globin chain mass analysis, and chemical modification of the proteolytic peptides identified the presence of Hb Beckman, a genetic variant of hemoglobin, in the experimental sample. A similar surface area to charge ratio between HbA(1c) and Hb Beckman might have resulted in the coelution of the variant with HbA(1c) in CE HPLC. Therefore, in the screening of diabetes mellitus through the estimation of HbA(1c), it is important to look for genetic variants of hemoglobin in samples that show abnormally high glycemic index, and HbA(1c) must be estimated using an alternative method. (C) 2015 Elsevier Inc. All rights reserved.
Resumo:
To investigate the efficacy of sensor-augmented pump therapy vs. multiple daily injection therapy in patients with suboptimally controlled Type 1 diabetes.
Resumo:
Study Design. Analysis of a case series of 24 Lenke 1C adolescent idiopathic scoliosis (AIS) patients receiving selective thoracoscopic anterior scoliosis correction. Objective. To report the behaviour of the compensatory lumbar curve in a group of Lenke IC AIS patients following thoracoscopic anterior scoliosis correction, and to compare the results of this study with previously published data. Summary of Background Data. Several prior studies have reported spontaneous lumbar curve correction for both anterior and posterior selective fusion in Lenke 1C/King-Moe II patients; however to our knowledge no previous studies have reported outcomes of thoracoscopic anterior correction for this curve type. Methods. All AIS patients with a curve classification of Lenke 1C and a minimum of 24 months follow-up were retrieved from a consecutive series of 190 AIS patients who underwent thoracoscopic anterior instrumented fusion. Cobb angles of the major curve, instrumented levels, compensatory lumbar curve, and T5-T12 kyphosis were recorded, as well as coronal spinal balance, T1 tilt angle and shoulder balance. All radiographic parameters were measured before surgery and at 2, 6, 12 and 24 months after surgery. Results. Twenty-four female patients with right thoracic curves had a mean thoracic Cobb angle of 53.0° before surgery, decreasing to 24.9° two years after surgery. The mean lumbar compensatory Cobb angle was 43.5° before surgery, spontaneously correcting to 25.4° two years after surgery, indicating balance between the thoracic and lumbar scoliotic curves. The lumbar correction achieved (41.8%) compares favourably to previous studies. Conclusions. Selective thoracoscopic anterior fusion allows spontaneous lumbar curve correction and achieves coronal balance of main thoracic and compensatory lumbar curves, good cosmesis and patient satisfaction. Correction and balance are maintained 24 months after surgery.
Resumo:
Many, but not all, of the current 21 serotypes of Yersinia pseudotuberculosis have been investigated with regard to the chemical structures of their O-specific polysaccharide (OPS) and the genetic basis of their biosynthesis. Completion of the genetics and structures of the remaining serotypes will enhance our understanding of the emerging relationship between genetics and structures within this species. Here, we present a structural and genetic analysis of the Y. pseudotuberculosis serotype O:1c OPS. Our results showed that this OPS has the same backbone as Y. pseudotuberculosis O:2b, but with a 3,6-dideoxy-D-ribo-hexofuranose (paratofuranose, Parf) side-branch instead of a 3,6-dideoxy-D-xylo-hexopyranose (abequopyranose, Abep). The 3'-end of the gene cluster is the same as for O:2b and has the genes for synthesis of the backbone and for processing the completed repeat unit. The 5'-end of the cluster consists of the same genes as O:1b for synthesis of Parf and a related gene for its transfer to the repeating unit backbone.
Resumo:
A new family of low-power logic circuits, employing a multiemitter transistor input circuit and a modified complementary p-n-p n-p-n output stage, having almost the same performance as standard TTL circuits and suitable for IC use, is reported in this correspondence.
Resumo:
Niobium-based alloys are well-established refractory materials; as a result of their high melting temperature and good creep properties, these alloys find their applications in nuclear reactors. The present study deals with a microstructural response of these materials during hot working. The evolution of microstructure and texture during high-temperature deformation has been investigated in the temperature range 1500-1700A degrees C and strain rate range of 0.001-0.1 s(-1). For each deformed sample, the microstructure has been examined in detail. The microstructural features clearly revealed the formation of a substructure and the occurrence of dynamic recrystallization in a proper temperature-strain rate window. At low strain rates, the necklace structure formation was more prominent.
Resumo:
La presente lista constituye el tercer suplemento a las bibliografías de los peces de Agua Dulce de la Argentina y Uruguay (López et al., 1981, 1982, 1986). Los criterios que sustentan la inclusión de los trabajos son los señalados en 1981. Se incluyen en este trabajo los artículos posteriores a 1986 y los que han pasado inadvertidos en las anteriores. Se mencionan las especies citadas, salvo cuando figuran en el título del trabajo o su número es excesivo. (PDF tiene 36 paginas.)
Resumo:
Near-infrared to ultraviolet upconversion luminescence was observed in the Pr3+ :Y2SiO5 crystal with 120 fs, 800 mn infrared laser irradiation. The observed emissions at around 270 nm and 305 nm could be assigned to 5d -> 4f transitions of Pr3+ ions. The relationship between the upconversion luminescence intensity and the pump power of the femtosecond laser reveals that the UV emission belongs to simultaneous three-photon absorption induced upconversion luminescence. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
对我们所制作的λ/4相移DFB掺Yb3+光纤激光器的运行特性进行了研究。研究表明:光纤端面菲涅尔反射会破坏激光器的单纵模运行,因此为获得稳定的羊纵模运行须使用隔离器或甘油清除光纤端面菲涅尔反射;机械扰动则会使沿光纤传输的单偏振激光的偏振面发生变化;温度的涨落则会引起激光输出功率的不稳定涨落。所研制à/4相移DFB单纵模、单偏振激光器具有如下特性:阈值为38mW,当泵浦功率为140 mW时,获得了25mW的1053 nm单 纵模、羊偏振激光.偏振消光比约30 dB,单纵模激光功率涨落小于2%,边模抑制比约6
Resumo:
The Er3+-Yb3+ codoped Al2O3 has been prepared by the sol-gel method using the aluminium isopropoxide [Al(OC3H7)(3)]-derived Al2O3 sols with addition of the erbium nitrate [Er(NO3)(3) center dot 5H(2)O] and ytterbium nitrate [Yb(NO3)(3) center dot 5H(2)O]. The phase structure, including only two crystalline types of doped Al2O3 phases, theta and gamma, was obtained for the 1 mol% Er3+ and 5 mol% Yb3+ codoped Al2O3 at the sintering temperature of 1,273 K. By a 978 nm semiconductor laser diodes excitation, the visible up-conversion emissions centered at about 523, 545, and 660 nm were obtained. The temperature dependence of the green up-conversion emissions was studied over a wide temperature range of 300-825 K, and the reasonable agreement between the calculated temperature by the fluorescence intensity ratio (FIR) theory and the measured temperature proved that Er3+-Yb3+ codoped Al2O3 plays an important role in the application of high temperature sensor.
Resumo:
Cr2+掺杂II-VI族化合物在中红外波段的输出,在气体检测、遥感、通信、眼科医学、神经外科等领域有着重要的应用前景。目前已经获得了最大1.7 W的连续输出功率,18.5 W的平均脉冲功率,1100 nm的调谐范围和最窄4 ps的脉宽。对Cr2+:ZnSe连续、脉冲、随机纳米激光器以及其它的Cr2+掺杂II-VI族化合物激光器的最新的国内外研究进展进行了综述。
Resumo:
We demonstrate passive Q-switching of short-length double-clad Tm3+-doped silica fiber lasers near 2 mu m pumped by a laser diode array (LDA) at 790 nm. Polycrystalline Cr2+:ZnSe microchips with thickness from 0.3 to 1 mm are adopted as the Q-switching elements. Pulse duration of 120 ns, pulse energy over 14 mu] and repetition rate of 53 kHz are obtained from a 5-cm long fiber laser. As high as 530 kHz repetition rate is achieved from a 50-cm long fiber laser at similar to 10-W pump power. The performance of the Q-switched fiber lasers as a function of fiber length is also analyzed. (c) 2008 Elsevier B.V. All rights reserved.