938 resultados para winogradsly columns


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reinforced concrete (RC) jacketing is a common method to retrofit existing columns with poor structural performance. It can be applied in two different ways: if the continuity of the jacket is ensured, the axial load of the column can be transferred to the jacket, which will be directly loaded; conversely, if no continuity is provided, the jacket induces only confinement action. In both cases the strength and ductility evaluation is rather complex, due to the different physical phenomena included, such as confinement, composite action core-jacket, preload, buckling of longitudinal bars.
Although different theoretical studies have been carried out to calculate the confinement effects, a practical approach to evaluate the flexural capacity and ductility is still missing. The calculation of these quantities is often related to the use of commercial computer programs, taking advantage of numerical methods such as fiber method or finite element method.
This paper presents a simplified approach to calculate the flexural strength and ductility of square RC jacketed sections subjected to axial load and bending moment. In particular the proposed approach is based on the calibration of the stress-block parameters including the confinement effect. Equilibrium equations are determined and buckling of longitudinal bars is modeled with a suitable stress-strain law. Moment-curvature curves are derived with simple calculations. Finally, comparisons are made with numerical analyses carried out with the code OpenSees and with experimental data available in the literature, showing good agreement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reinforced concrete (RC) jacketing is a common method for retrofitting existing columns with poor structural performance. It can be applied in two different ways: if the continuity of the jacket is ensured, the axial load of the column can be transferred to the jacket, which will be directly loaded; conversely, if no continuity is provided, the jacket will induce only confinement action. In both cases the strength and ductility evaluation is rather complex, due to the different physical phenomena included, such as confinement, core-jacket composite action, preload and buckling of longitudinal bars.
Although different theoretical studies have been carried out to calculate the confinement effects, a practical approach to evaluate the flexural capacity and ductility is still missing. The calculation of these quantities is often related to the use of commercial software, taking advantage of numerical methods such as fibre method or finite element method.
This paper presents a simplified approach to calculate the flexural strength and ductility of square RC jacketed sections subjected to axial load and bending moment. In particular the proposed approach is based on the calibration of the stress-block parameters including the confinement effect. Equilibrium equations are determined and buckling of longitudinal bars is modelled with a suitable stress-strain law. Moment-curvature curves are derived with simple calculations. Finally, comparisons are made with numerical analyses carried out with the code OpenSees and with experimental data available in the literature, showing good agreement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ancient columns, made with a variety of materials such as marble, granite, stone or masonry are an important part of the
European cultural heritage. In particular columns of ancient temples in Greece and Sicily which support only the architrave are
characterized by small axial load values. This feature together with the slenderness typical of these structural members clearly
highlights as the evaluation of the rocking behaviour is a key aspect of their safety assessment and maintenance. It has to be noted
that the rocking response of rectangular cross-sectional columns modelled as monolithic rigid elements, has been widely investigated
since the first theoretical study carried out by Housner (1963). However, the assumption of monolithic member, although being
widely used and accepted for practical engineering applications, is not valid for more complex systems such as multi-block columns
made of stacked stone blocks, with or without mortar beds. In these cases, in fact, a correct analysis of the system should consider
rocking and sliding phenomena between the individual blocks of the structure. Due to the high non-linearity of the problem, the
evaluation of the dynamic behaviour of multi-block columns has been mostly studied in the literature using a numerical approach
such as the Discrete Element Method (DEM). This paper presents an introductory study about a proposed analytical-numerical
approach for analysing the rocking behaviour of multi-block columns subjected to a sine-pulse type ground motion. Based on the
approach proposed by Spanos (2001) for a system made of two rigid blocks, the Eulero-Lagrange method to obtain the motion
equations of the system is discussed and numerical applications are performed with case studies reported in the literature and with a
real acceleration record. The rocking response of single block and multi-block columns is compared and considerations are made
about the overturning conditions and on the effect of forcing function’s frequency.
.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A análise dos efeitos dos sismos mostra que a investigação em engenharia sísmica deve dar especial atenção à avaliação da vulnerabilidade das construções existentes, frequentemente desprovidas de adequada resistência sísmica tal como acontece em edifícios de betão armado (BA) de muitas cidades em países do sul da Europa, entre os quais Portugal. Sendo os pilares elementos estruturais fundamentais na resistência sísmica dos edifícios, deve ser dada especial atenção à sua resposta sob ações cíclicas. Acresce que o sismo é um tipo de ação cujos efeitos nos edifícios exige a consideração de duas componentes horizontais, o que tem exigências mais severas nos pilares comparativamente à ação unidirecional. Assim, esta tese centra-se na avaliação da resposta estrutural de pilares de betão armado sujeitos a ações cíclicas horizontais biaxiais, em três linhas principais. Em primeiro lugar desenvolveu-se uma campanha de ensaios para o estudo do comportamento cíclico uniaxial e biaxial de pilares de betão armado com esforço axial constante. Para tal foram construídas quatro séries de pilares retangulares de betão armado (24 no total) com diferentes características geométricas e quantidades de armadura longitudinal, tendo os pilares sido ensaiados para diferentes histórias de carga. Os resultados experimentais obtidos são analisados e discutidos dando particular atenção à evolução do dano, à degradação de rigidez e resistência com o aumento das exigências de deformação, à energia dissipada, ao amortecimento viscoso equivalente; por fim é proposto um índice de dano para pilares solicitados biaxialmente. De seguida foram aplicadas diferentes estratégias de modelação não-linear para a representação do comportamento biaxial dos pilares ensaiados, considerando não-linearidade distribuída ao longo dos elementos ou concentrada nas extremidades dos mesmos. Os resultados obtidos com as várias estratégias de modelação demonstraram representar adequadamente a resposta em termos das curvas envolventes força-deslocamento, mas foram encontradas algumas dificuldades na representação da degradação de resistência e na evolução da energia dissipada. Por fim, é proposto um modelo global para a representação do comportamento não-linear em flexão de elementos de betão armado sujeitos a ações biaxiais cíclicas. Este modelo tem por base um modelo uniaxial conhecido, combinado com uma função de interação desenvolvida com base no modelo de Bouc- Wen. Esta função de interação foi calibrada com recurso a técnicas de otimização e usando resultados de uma série de análises numéricas com um modelo refinado. É ainda demonstrada a capacidade do modelo simplificado em reproduzir os resultados experimentais de ensaios biaxiais de pilares.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an experimental investigation carried out on concrete filled fibre reinforced polymers (FRP) tubes, subjected to monotonic and cyclic loading. Two types of FRP materials were used: glass fibres and carbon fibres. Different failure modes and the effect of concrete fill, type of confinement materials, reinforcement ratio based on tube thickness and type of loading are examined. The study shows that external confinement of concrete by means of modern materials, such fibre reinforced polymers, can enhance its strength and ductility as well as result in large energy absorption capacity. This has important safety implications, especially in regions with seismic activity. A model that predicts the behaviour of confined concrete which takes into account the stiffness and effectiveness of different confinement materials is briefly introduced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Volatile organic compounds are a common source of groundwater contamination that can be easily removed by air stripping in columns with random packing and using a counter-current flow between the phases. This work proposes a new methodology for the column design for any particular type of packing and contaminant avoiding the necessity of a pre-defined diameter used in the classical approach. It also renders unnecessary the employment of the graphical Eckert generalized correlation for pressure drop estimates. The hydraulic features are previously chosen as a project criterion and only afterwards the mass transfer phenomena are incorporated, in opposition to conventional approach. The design procedure was translated into a convenient algorithm using C++ as programming language. A column was built in order to test the models used either in the design or in the simulation of the column performance. The experiments were fulfilled using a solution of chloroform in distilled water. Another model was built to simulate the operational performance of the column, both in steady state and in transient conditions. It consists in a system of two partial non linear differential equations (distributed parameters). Nevertheless, when flows are steady, the system became linear, although there is not an evident solution in analytical terms. In steady state the resulting system of ODE can be solved, allowing for the calculation of the concentration profile in both phases inside the column. In transient state the system of PDE was numerically solved by finite differences, after a previous linearization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One important step in the design of air stripping operations for the removal of VOC is the choice of operating conditions, which are based in the phase ratio. This parameter sets on directly the stripping factor and the efficiency of the operation. Its value has an upper limit determined by the flooding regime, which is previewed using empirical correlations, namely the one developed by Eckert. This type of approach is not suitable for the development of algorithms. Using a pilot scale column and a convenient solution, the pressure drop was determined in different operating conditions and the experimental values were compared with the estimations. This particular research will be incorporated in a global model for simulating the dynamics of air stripping using a multi variable distributed parameter system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Volatile organic compounds are a common source of groundwater contamination that can be easily removed by air stripping in columns with random packing and using a counter-current flow between the phases. This work proposes a new methodology for column design for any type of packing and contaminant which avoids the necessity of an arbitrary chosen diameter. It also avoids the employment of the usual graphical Eckert correlations for pressure drop. The hydraulic features are previously chosen as a project criterion. The design procedure was translated into a convenient algorithm in C++ language. A column was built in order to test the design, the theoretical steady-state and dynamic behaviour. The experiments were conducted using a solution of chloroform in distilled water. The results allowed for a correction in the theoretical global mass transfer coefficient previously estimated by the Onda correlations, which depend on several parameters that are not easy to control in experiments. For best describe the column behaviour in stationary and dynamic conditions, an original mathematical model was developed. It consists in a system of two partial non linear differential equations (distributed parameters). Nevertheless, when flows are steady, the system became linear, although there is not an evident solution in analytical terms. In steady state the resulting ODE can be solved by analytical methods, and in dynamic state the discretization of the PDE by finite differences allows for the overcoming of this difficulty. To estimate the contaminant concentrations in both phases in the column, a numerical algorithm was used. The high number of resulting algebraic equations and the impossibility of generating a recursive procedure did not allow the construction of a generalized programme. But an iterative procedure developed in an electronic worksheet allowed for the simulation. The solution is stable only for similar discretizations values. If different values for time/space discretization parameters are used, the solution easily becomes unstable. The system dynamic behaviour was simulated for the common liquid phase perturbations: step, impulse, rectangular pulse and sinusoidal. The final results do not configure strange or non-predictable behaviours.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Letter to S.D. Woodruff from an illegible signature stating that he suspects a clerical error in one of the columns, n.d.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

By using suitable parameters, we present a uni¯ed aproach for describing four methods for representing categorical data in a contingency table. These methods include: correspondence analysis (CA), the alternative approach using Hellinger distance (HD), the log-ratio (LR) alternative, which is appropriate for compositional data, and the so-called non-symmetrical correspondence analysis (NSCA). We then make an appropriate comparison among these four methods and some illustrative examples are given. Some approaches based on cumulative frequencies are also linked and studied using matrices. Key words: Correspondence analysis, Hellinger distance, Non-symmetrical correspondence analysis, log-ratio analysis, Taguchi inertia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Research into transmissible spongiform encephalopathy (TSE) diseases has become a high priority worldwide in recent years yet remarkably little is known about the behaviour of TSE infectivity in the environment. The resilience and stability of prion proteins could lead to soils becoming a potential reservoir of TSE infectivity as a result of contamination from activities such as infected carcass burial or the dispersion of effluents from slaughter houses, or by contamination of pastures by infected animals, (e.g. scrapie in sheep). Knowledge of the fate of prion proteins in soils, and associated physico-chemical conditions which favour migration, can be used to help prevent re-infection of animals through grazing, to protect watercourses and develop good management practices. In two consecutive experiments of 9 and 6 months, the migration of recombinant ovine PrP (recPrP) in soil columns was followed under contrasting levels of microbial activity (normal versus reduced), under varying regimes of soil water content and redox potential, and in two different soil types (loamy sand and clay loam). At each analysis time (1, 3, 6 or 9 months), in both soil types, full-length recPrP was detected in the original contaminated layer, indicating the resilience and stability of recPrP under varied soil conditions, even in the presence of active soil microbial populations. Evidence of protein migration was found in every soil column at the earliest analysis time (1 or 3 months), but was restricted to a maximum distance of 1 cm, indicative of limited initial mobility in soils followed by strong adsorption over the following days to weeks. The survival of recPrP in the soil over a period of at least 9 months was demonstrated. In this study, recPrP was used as an indicator for potential TSE infectivity, although infectivity tests should be carried out before conclusions can be drawn regarding the infection risk posed by prions in soil. However, it has been demonstrated that soil is likely to act as a significant barrier to the dispersion of contaminated material at storage or burial sites. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cryoturbated Upper Chalk is a dichotomous porous medium wherein the intra-fragment porosity provides water storage and the inter-fragment porosity provides potential pathways for relatively rapid flow near saturation. Chloride tracer movement through 43 cm long and 45 cm diameter undisturbed chalk columns was studied at water application rates of 0.3, 1.0, and 1.5 cm h(-1). Microscale heterogeneity in effluent was recorded using a grid collection system consisting of 98 funnel-shaped cells each 3.5 cm in diameter. The total porosity of the columns was 0.47 +/- 0.02 m(3) m(-3), approximately 13% of pores were >15 mu m diameter, and the saturated hydraulic conductivity was 12.66 +/- 1.31 m day(-1). Although the column remained unsaturated during the leaching even at all application rates, proportionate flow through macropores increased as the application rate decreased. The number of dry cells (with 0 ml of effluent) increased as application rate decreased. Half of the leachate was collected from 15, 19 and 22 cells at 0.3, 1.0, 1.5 cm h(-1) application rates respectively. Similar breakthrough curves (BTCs) were obtained at all three application rates when plotted as a function of cumulative drainage, but they were distinctly different when plotted as a function of time. The BTCs indicate that the columns have similar drainage requirement irrespective of application rates, as the rise to the maxima (C/C-o) is almost similar. However, the time required to achieve that leaching requirement varies with application rates, and residence time was less in the case of a higher application rate. A two-region convection-dispersion model was used to describe the BTCs and fitted well (r(2) = 0.97-0-99). There was a linear relationship between dispersion coefficient and pore water velocity (correlation coefficient r = 0.95). The results demonstrate the microscale heterogeneity of hydrodynamic properties in the Upper Chalk. Copyright (C) 2007 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Columnar mesophases based on alternating triphenylene and hexaphenyltriphenylene moieties are exceptionally stable and able to accommodate bulky side-chain substituents within the alkyl chain continuum between the columns. This paper presents a system in which the triphenylene bears a fullerene on its side-chain and the hexaphenyltriphenylene equivalent is the aza-derivative hexakis(4-nonylphenyl)dipyrazino[2,3-f : 2'3'-h] quinoxalene, PDQ9. The mesophase formed was identified as hexagonal columnar (Col(h)) by X-ray diffraction (a = 25.2 angstrom and c = 3.5 angstrom) but, in addition to the expected peaks, there is indication of a two-dimensional hexagonal superlattice with d-spacing 59 angstrom. This superlattice is believed to arise from ordering of the fullerenes within the liquid crystal matrix. It can be explained on the assumption that, to maximise fullerene-fullerene contact, the fullerenes form chains which wrap around the central column in every group of seven columns of the triphenylene : PDQ9 Col(h) array.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple procedure was developed for packing PicoFrit HPLC columns with chromatographic stationary phase using a reservoir fabricated from standard laboratory HPLC fittings. Packed columns were mounted onto a stainless steel ultra-low volume precolumn filter assembly containing a 0.5-mu m pore size steel frit. This format provided a conduit for the application of the nanospray voltage and protected the column from obstruction by sample material. The system was characterised and operational performance assessed by analysis of a range of peptide standards (n = 9).