963 resultados para variance and coherence
Resumo:
This study was carried out to evaluate the performance and egg quality of laying hens, in their second laying cycle submitted to different forced-molting methods and three environmental temperatures. Six hundred layers were distributed in a completely randomized experimental design with 15 treatments with five replicates of eight birds each, according to 5x3 factorial arrangement (molting methods vs. temperatures). The following forced-molting methods were applied: 90%, 70%, 50% dietary alfalfa inclusion, addition of 2,800 ppm zinc, and feed fasting. Temperatures were: 20 ºC, 27 ºC and 35 ºC. At the end of each period of the second laying cycle, bird performance and egg quality were evaluated. Data were submitted to analysis of variance and means were compared by orthogonal and polynomial contrasts. The highest alfalfa inclusion level (90% alfalfa and 10% basal diet) proved to be efficient as compared to the other methods, independently of temperature.
Resumo:
Were estimate (co)variance and genetic associations between conformation, finishing precocity and muscling visual scores measured at weaning (SCW, SFW and SMW, respectively) and yearling (SCY. SFY and SMY, respectively) with mature weight (MW) in Nelore cows, in order to predict the possible changes that inclusion of visual scores in beef cattle selection indices would bring to female mature weight. The data set contained records of 36,757 females, born between 1993 and 2006, belonging to the Jacarezinho cattle raising farm. (Co)variance components were estimated by bivariate animal models using Bayesian inference method through Gibbs sampling, assuming a linear model for MW and a nonlinear (threshold) model for conformation, finishing precocity and muscling visual scores. The first 10,000 rounds were considered as the burn-in period and discarded. The posterior means of direct heritability distributions were: 0.16 +/- 0.02 (SCW); 0.20 +/- 0.02 (SFW); 0.19 +/- 0.02 (SMW); 0.24 +/- 0.02 (SCY); 0.31 +/- 0.02 (SFY); 0.32 +/- 0.02 (SMY) and 0.46 +/- 0.04 (MW). Estimates of genetic correlations between visual scores and MW were positive and moderate, ranging from 0.27 +/- 0.06 to 0.36 +/- 0.04. Visual scores and MW should respond favorably to direct selection. Mature weight can be used in Nelore breeding programs designed to monitor the cows' size. Selection of animals with higher conformation, finishing precocity and muscling scores, especially at yearling, should promote an increase in cows' mature weight. (c) 2010 Elsevier B.V. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Physical exercise and statins, which are recommended for the treatment of dyslipidemia, are independently associated to the occurrence of muscle injury. The objective is analyze the effect of aerobic exercise associated to the use of simvastatin on the morphology of the gastrocnemius muscle. Thirty Wistar rats were divided into six groups, two of which received a standard diet (1 sedentary and 1 exercised) and four (1 sedentary with medication, 1 sedentary without medication, 1 exercised with medication, 1 exercised without medication) received a hypercholesterolemic diet (standard diet with the addition of cholesterol and coconut oil). Simvastatin (20 mg/Kg) was administered five days a week for eight weeks, together with aerobic training on a treadmill (9.75 m/min) for 60 minutes a day. The gastrocnemius muscle was removed, sliced, stained with Hematoxylin-Eosin and submitted to a histochemical reaction to determine mitochondrial activity. The data were analyzed using a paired t-test, analysis of variance and Scheffe's post hoc test (p<0.05). Greater histological alterations were found in the medicated and exercised animals, with a greater frequency of occurrence as well. The histochemical analysis revealed that the medicated groups had fibers with more intensive mitochondrial activity alongside fibers with an absence of reaction. The morphometric analysis revealed no significant differences between groups. It is suggested that simvastatin is a medication that leads to the occurrence of muscle injury and its administration in association with physical activity may exacerbate these injuries. This finding may be related to cellular respiration.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: The aim of this in vitro study was to assess the biomechanical stability of 9 different osteosynthesis methods after sagittal split ramus osteotomy by simulating the masticatory forces and using a 3-point biomechanical test method.Materials and Methods: Forty-five polyurethane hemimandibles with bone-like consistency were randomly assigned to 9 groups (n = 5) and subjected to sagittal split ramus osteotomy. After 4-mm advancement of the distal segment, the bone segments were fixed by different osteosynthesis methods using 2.0-mm miniplate/screw systems: group A, one 4-hole conventional straight miniplate; group B, one 4-hole locking straight miniplate; group C, one 4-hole conventional miniplate and one bicortical screw; group D, one 4-hole locking miniplate and 1 bicortical screw; group E, one 6-hole conventional straight miniplate; group F, one 6-hole locking straight miniplate; group (3: two 4-hole conventional straight miniplates; group H. two 4-hole locking straight miniplates; and group 1, 3 bicortical screws in an inverted-L. pattern. All models were mounted on a base especially constructed for this purpose. Using a 3-point biomechanical test model, the hemimandibles were loaded in compressive strength in an Instron machine (Norwood, MA) until a 3-mm displacement occurred between segments vertically or horizontally. Data were analyzed by analysis of variance and Tukey test (alpha = 1%).Results: The multiparametric comparison of the groups showed a statistically significant difference (P<.01) between groups that used 2 miniplates (groups G and H), 1 miniplate and 1 bicortical screw (groups C and D), and only bicortical screws (group D compared with groups that used only 1 miniplate with 2 screws per segment (groups A and B) and 3 screws per segment (groups E and F).Conclusion: The placement of 2.0-mm-diameter bicortical screws in the retromolar region, associated or not with conventional and locking miniplates with monocortical screws, promoted a better stabilization of bone segments. Locking miniplates presented a better performance in bone fixation in all groups. (C) 2010 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 68:724-730, 2010
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The aim of the present retrospective study was to evaluate the influence of age and gender on upper and lower airway width and upper lip length. In this study, 390 lateral cephalograms were divided into 13 age groups (ranging from 6 to 18 years) and were analyzed. The inter-group differences were analyzed using a MANOVA (Multivariate Analysis of the Variance), and the intragroup differences were analyzed using an ANOVA (Analysis of the Variance) and Tukey's test. The results of the present study indicated that although the airway width and the upper lip length increased with age, the lower airway width exhibited variable growth between the ages of six and eighteen years. The airway width was significantly greater in females than males, whereas the upper airway width was similar between these two genders. The lip length was significantly shorter in females than males. The lower airway width and upper lip length were significantly different between males and females, whereas the upper airway width was similar for the genders. The upper airway width and upper lip exhibited incremental growth between the ages of six and eighteen years. The upper lip closely followed the growth pattern of the upper airway width; the growth plateaued between the ages of 6 and 9 years, increased from 9 to 16 years and plateaued from 16 to 18 years.
Resumo:
Purpose: This study's purpose was to assess the amount of dental enamel loss on primary incisors after manual or mechanical microabrasion with a phosphoric acid/pumice poste. Methods: Ten exfoliated primary maxillary incisors were bisected faciolingually and the resulting 20 halves were randomly assigned to 2 groups: group 1 (N=10) manual technique (plastic spatula); and group 2 (N=10) mechanical technique (rubber cup attached to a low-speed handpiece). Microabrasion was performed on the buccal surface using an abrasive paste prepared with 37% phosphoric acid and pumice. Ten 20-second applications alternated with 20-second risings were performed in each group. Enamel thickness measurements made under stereomi-croscopy before and after microabrasion were analyzed statistically by analysis of variance and pairwise t test. Results: There was a statistically significant difference (P=.003) between the manual and mechanical techniques. The mechanical technique produced a mean enamel loss of 274.16 mu m (66% of total enamel thickness), while the mean enamel loss with the manual technique was 152.59 mu m (39% of total enamel thickness). Conclusion: Manual microabrasion using a plastic spatula removed less enamel, but was sufficient to eliminate most superficial stains and defects, and may be a viable option for the microabrasive technique on primary teeth. (Pediatr Dent 2008;30:420-3) Received March 15, 2007 / Lost Revision September 19, 2007 / Revision Accepted October 19, 2007
Resumo:
Statement of problem. Denture bases may become increasingly weaker as a result of thermal stress and flexural cyclic loading. Information regarding this potential problem and its relationship to the denture base reline is limited.Purpose. This study evaluated the influence of thermal and mechanical stresses on the strength of intact and relined denture bases.Material and methods. Twenty-eight microwave-polymerized (Acron MC) intact denture bases were prepared in the shape of a 3-mm-thick maxillary denture. Additionally, fifty-six 2-mm-thick denture bases were relined with 1 mm of autopolymerizing resin (Tokuyama Rebase Fast II or New Truliner) (n = 28). Intact and relined specimens were divided into 4 groups (n = 7) as follows: without stress (control); a mechanical stress at 0.8 Hz for 10,000 cycles; 5000 thermal cycles between 5 degrees C and 55 degrees C; or a combination thermo-mechanical stress. The specimens were vertically loaded in compression with a rounded rod at 5 mm/min until failure, using a universal testing machine. Data on maximum fracture load (N), deflection at fracture (%), and fracture energy (N-mm) were analyzed by 2-way analysis of variance and Student-Newman-Keuls tests (alpha = .05).Results. The strength of the denture bases relined with New Truliner was not significantly affected by any of the experimental conditions, but comparing the control groups, New Truliner exhibited the lowest maximum fracture load values. The maximum fracture load of intact denture bases (P = .002) and those relined with Tokuyama Rebase Fast II (P = .01) showed a significant decrease after thermal stress. Additionally, cyclic loading significantly decreased the maximum fracture load (P < .001), deflection at fracture (P = .025), and fracture energy (P < .001) of intact denture bases and those relined with Tokuyama Rebase (P values of .002, .039, and .001, respectively).Conclusion. Thermal and mechanical stresses exert deleterious effects on the strength of intact and/or relined denture bases, which vary according to the relining material used.