997 resultados para unit disk graphs


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mycobacterium kansasii is a pulmonary pathogen that has been grown readily from municipal water, but rarely isolated from natural waters. A definitive link between water exposure and disease has not been demonstrated and the environmental niche for this organism is poorly understood. Strain typing of clinical isolates has revealed seven subtypes with Type 1 being highly clonal and responsible for most infections worldwide. The prevalence of other subtypes varies geographically. In this study 49 water isolates are compared with 72 patient isolates from the same geographical area (Brisbane, Australia), using automated repetitive unit PCR (Diversilab) and ITS RFLP. The clonality of the dominant clinical strain type is again demonstrated but with rep-PCR, strain variation within this group is evident comparable with other reported methods. There is significant heterogeneity of water isolates and very few are similar or related to the clinical isolates. This suggests that if water or aerosol transmission is the mode of infection, then point source contamination likely occurs from an alternative environmental source.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although accelerometers are extensively used for assessing gait, limited research has evaluated the concurrent validity of these devices on less predictable walking surfaces or the comparability of different methods used for gravitational acceleration compensation. This study evaluated the concurrent validity of trunk accelerations derived from a tri-axial inertial measurement unit while walking on firm, compliant and uneven surfaces and contrasted two methods used to remove gravitational accelerations: i) subtraction of the best linear fit from the data (detrending), and; ii) use of orientation information (quaternions) from the inertial measurement unit. Twelve older and twelve younger adults walked at their preferred speed along firm, compliant and uneven walkways. Accelerations were evaluated for the thoracic spine (T12) using a tri-axial inertial measurement unit and an eleven-camera Vicon system. The findings demonstrated excellent agreement between accelerations derived from the inertial measurement unit and motion analysis system, including while walking on uneven surfaces that better approximate a real-world setting (all differences <0.16 m.s−2). Detrending produced slightly better agreement between the inertial measurement unit and Vicon system on firm surfaces (delta range: −0.05 to 0.06 vs. 0.00 to 0.14 m.s−2), whereas the quaternion method performed better when walking on compliant and uneven walkways (delta range: −0.16 to −0.02 vs. −0.07 to 0.07 m.s−2). The technique used to compensate for gravitational accelerations requires consideration in future research, particularly when walking on compliant and uneven surfaces. These findings demonstrate trunk accelerations can be accurately measured using a wireless inertial measurement unit and are appropriate for research that evaluates healthy populations in complex environments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This contribution is focused on plasma-enhanced chemical vapor deposition systems and their unique features that make them particularly attractive for nanofabrication of flat panel display microemitter arrays based on ordered patterns of single-crystalline carbon nanotip structures. The fundamentals of the plasma-based nanofabrication of carbon nanotips and some other important nanofilms and nanostructures are examined. Specific features, challenges, and potential benefits of using the plasma-based systems for relevant nanofabrication processes are analyzed within the framework of the "plasma-building unit" approach that builds up on extensive experimental data on plasma diagnostics and nanofilm/nanostructure characterization, and numerical simulation of the species composition in the ionized gas phase (multicomponent fluid models), ion dynamics and interaction with ordered carbon nanotip patterns, and ab initio computations of chemical structure of single crystalline carbon nanotips. This generic approach is also applicable for nanoscale assembly of various carbon nanostructures, semiconductor quantum dot structures, and nano-crystalline bioceramics. Special attention is paid to most efficient control strategies of the main plasma-generated building units both in the ionized gas phase and on nanostructured deposition surfaces. The issues of tailoring the reactive plasma environments and development of versatile plasma nanofabrication facilities are also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fault identification in industrial machine is a topic of major importance under engineering point of view. In fact, the possibility to identify not only the type, but also the severity and the position of a fault occurred along a shaft-line allows quick maintenance and shorten the downtime. This is really important in the power generation industry where the units are often of several tenths of meters long and where the rotors are enclosed by heavy and pressure-sealed casings. In this paper, an industrial experimental case is presented related to the identification of the unbalance on a large size steam turbine of about 1.3 GW, belonging to a nuclear power plant. The case history is analyzed by considering the vibrations measured by the condition monitoring system of the unit. A model-based method in the frequency domain, developed by the authors, is introduced in detail and it is then used to identify the position of the fault and its severity along the shaft-line. The complete model of the unit (rotor – modeled by means of finite elements, bearings – modeled by linearized damping and stiffness coefficients and foundation – modeled by means of pedestals) is analyzed and discussed before being used for the fault identification. The assessment of the actual fault was done by inspection during a scheduled maintenance and excellent correspondence was found with the identified one by means of authors’ proposed method. Finally a complete discussion is presented about the effectiveness of the method, even in presence of a not fine tuned machine model and considering only few measuring planes for the machine vibration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

4-Hexylbithienopyridine has been prepared as a novel electron-accepting monomer for conjugated polymers. To test its electronic properties, alternating copolymers with fluorene and indenofluorene polymers have been prepared. The copolymers displayed reduction potentials about 0.5 V lower than for the corresponding fluorene and indenofluorene homopolymers, indicating much improved electron-accepting properties. Analysis of the microscopic morphology of thin films of the copolymers by AFM shows that they lack the extensive supramolecular order seen with the homopolymers, which is attributed to the bithienopyridine units disrupting the π-stacking. LEDs using these polymers as the emitting layer produce blue-green emission with low turn-on voltages with aluminum electrodes confirming their improved electron affinity. The indenofluorene copolymer displayed an irreversible red shift in emission at high voltages, which is attributed to oxidation of the indenofluorene units. This red shift occurred at higher potentials than for indenofluorene homopolymers in LEDs, suggesting that the heterocyclic moieties offer some protection against electrically promoted oxidation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new online method is presented for estimation of the angular random walk and rate random walk coefficients of IMU (inertial measurement unit) gyros and accelerometers. The online method proposes a state space model and proposes parameter estimators for quantities previously measured from off-line data techniques such as the Allan variance graph. Allan variance graphs have large off-line computational effort and data storage requirements. The technique proposed here requires no data storage and computational effort of O(100) calculations per data sample.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Delirium is a common underdiagnosed condition in advanced cancer leading to increased distress, morbidity, and mortality. Screening improves detection but there is no consensus as to the best screening tool to use with patients with advanced cancer. Objective To determine the incidence of delirium in patients with advanced cancer within 72 hours of admission to an acute inpatient hospice using clinical judgement and validated screening tools. Method One hundred consecutive patients with advanced cancer were invited to be screened for delirium within 72 hours of admission to an acute inpatient hospice unit. Two validated tools were used, the Delirium Rating Scale-Revised 98 (DRS-R-98) and the Confusion Assessment Method (CAM) shortened diagnostic algorithm. These results were compared with clinical assessment by review of medical charts. Results Of 100 consecutive admissions 51 participated and of these 22 (43.1%) screened positive for delirium with CAM and/or DRS-R-98 compared to 15 (29.4%) by clinical assessment. Eleven (21.6%) were identified as hypoactive delirium and 5 (9.8%) as subsyndromal delirium. Conclusion This study confirms that delirium is a common condition in patients with advanced cancer.While there remains a lack of consensus regarding the choice of delirium screening tool this study supports theCAMas being appropriate. Further research may determine the optimal screening tool for delirium enabling the development of best practice clinical guidelines for routinemedical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The palette of fluorescent proteins (FPs) has grown exponentially over the past decade, and as a result, live imaging of cells expressing fluorescently tagged proteins is becoming more and more mainstream. Spinning disk confocal (SDC) microscopy is a high-speed optical sectioning technique and a method of choice to observe and analyze intracellular FP dynamics at high spatial and temporal resolution. In an SDC system, a rapidly rotating pinhole disk generates thousands of points of light that scan the specimen simultaneously, which allows direct capture of the confocal image with low-noise scientific grade-cooled charge-coupled device cameras, and can achieve frame rates of up to 1000 frames per second. In this chapter, we describe important components of a state-of-the-art spinning disk system optimized for live cell microscopy and provide a rationale for specific design choices. We also give guidelines of how other imaging techniques such as total internal reflection microscopy or spatially controlled photoactivation can be coupled with SDC imaging and provide a short protocol on how to generate cell lines stably expressing fluorescently tagged proteins by lentivirus-mediated transduction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim The aim of this reflective account is to provide a view of the intensive care unit (ICU) relative’s experiences of supporting and being supported in the ICU. Background Understanding the relatives’ experiences of ICU is important especially because a recent work has identified the potential for this group to develop post-traumatic stress disorder, a condition that is normally equated with the ICU survivor. Design A thematic analysis was used in identifying emerging themes that would be significant in an ICU nursing context. Setting The incident took place in two 8-bedded ICUs (Private and National Health Service) in October. Results Two emergent themes were identified from the reflective story – fear of the technological environment and feeling hopeless and helpless. Conclusion The use of relative stories as an insight into the live experiences of ICU relatives may give a deeper understanding of their life-world. The loneliness, anguish and pain of the ICU relative extends beyond the walls of the ICU, and this is often negated as the focus of the ICU team is the patient. Relevance to clinical practice: Developing strategies to support relatives might include the use of relative diaries used concurrently with patient diaries to support this groups recovery or at the very least a gaining a sense of understanding for their ICU experience. Relative follow-up clinics designed specifically to meet their needs where support and advice can be given by the ICU team, in addition to making timely and appropriate referrals to counselling services and perhaps involving spiritual leaders where appropriate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: The aim of this survey was to assess registered nurse’s perceptions of alarm setting and management in an Australian Regional Critical Care Unit. Background: The setting and management of alarms within the critical care environment is one of the key responsibilities of the nurse in this area. However, with up to 99% of alarms potentially being false-positives it is easy for the nurse to become desensitised or fatigued by incessant alarms; in some cases up to 400 per patient per day. Inadvertently ignoring, silencing or disabling alarms can have deleterious implications for the patient and nurse. Method: A total population sample of 48 nursing staff from a 13 bedded ICU/HDU/CCU within regional Australia were asked to participate. A 10 item open-ended and multiple choice questionnaire was distributed to determine their perceptions and attitudes of alarm setting and management within this clinical area. Results: Two key themes were identified from the open-ended questions: attitudes towards inappropriate alarm settings and annoyance at delayed responses to alarms. A significant number of respondents (93%) agreed that alarm fatigue can result in alarm desensitisation and the disabling of alarms, whilst 81% suggested the key factors are those associated with false-positive alarms and inappropriately set alarms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To examine personal and social demographics, and rehabilitation discharge outcomes of dysvascular and non-vascular lower limb amputees. Methods In total, 425 lower limb amputation inpatient rehabilitation admissions (335 individuals) from 2005 to 2011 were examined. Admission and discharge descriptive statistics (frequency, percentages) were calculated and compared by aetiology. Results Participants were male (74%), aged 65 years (s.d. 14), born in Australia (72%), had predominantly dysvascular aetiology (80%) and a median length of stay 48 days (interquartile range (IQR): 25–76). Following amputation, 56% received prostheses for mobility, 21% (n = 89) changed residence and 28% (n = 116) required community services. Dysvascular amputees were older (mean 67 years, s.d. 12 vs 54 years, s.d. 16; P < 0.001) and recorded lower functional independence measure – motor scores at admission (z = 3.61, P < 0.001) and discharge (z = 4.52, P < 0.001). More nonvascular amputees worked before amputation (43% vs 11%; P < 0.001), were prescribed a prosthesis by discharge (73% vs 52%; P < 0.001) and had a shorter length of stay (7 days, 95% confidence interval: –3 to 17), although this was not statistically significant. Conclusions Differences exist in social and demographic outcomes between dysvascular and non-vascular lower limb amputees.

Relevância:

20.00% 20.00%

Publicador: