818 resultados para stress and failure analysis


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The reduction of friction and wear in systems presenting metal-to-metal contacts, as in several mechanical components, represents a traditional challenge in tribology. In this context, this work presents a computational study based on the linear Archard's wear law and finite element modeling (FEM), in order to analyze unlubricated sliding wear observed in typical pin on disc tests. Such modeling was developed using finite element software Abaqus® with 3-D deformable geometries and elastic–plastic material behavior for the contact surfaces. Archard's wear model was implemented into a FORTRAN user subroutine (UMESHMOTION) in order to describe sliding wear. Modeling of debris and oxide formation mechanisms was taken into account by the use of a global wear coefficient obtained from experimental measurements. Such implementation considers an incremental computation for surface wear based on the nodal displacements by means of adaptive mesh tools that rearrange local nodal positions. In this way, the worn track was obtained and new surface profile is integrated for mass loss assessments. This work also presents experimental pin on disc tests with AISI 4140 pins on rotating AISI H13 discs with normal loads of 10, 35, 70 and 140 N, which represent, respectively, mild, transition and severe wear regimes, at sliding speed of 0.1 m/s. Numerical and experimental results were compared in terms of wear rate and friction coefficient. Furthermore, in the numerical simulation the stress field distribution and changes in the surface profile across the worn track of the disc were analyzed. The applied numerical formulation has shown to be more appropriate to predict mild wear regime than severe regime, especially due to the shorter running-in period observed in lower loads that characterizes this kind of regime.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Apple consumption is highly recomended for a healthy diet and is the most important fruit produced in temperate climate regions. Unfortunately, it is also one of the fruit that most ofthen provoks allergy in atopic patients and the only treatment available up to date for these apple allergic patients is the avoidance. Apple allergy is due to the presence of four major classes of allergens: Mal d 1 (PR-10/Bet v 1-like proteins), Mal d 2 (Thaumatine-like proteins), Mal d 3 (Lipid transfer protein) and Mal d 4 (profilin). In this work new advances in the characterization of apple allergen gene families have been reached using a multidisciplinary approach. First of all, a genomic approach was used for the characterization of the allergen gene families of Mal d 1 (task of Chapter 1), Mal d 2 and Mal d 4 (task of Chapter 5). In particular, in Chapter 1 the study of two large contiguos blocks of DNA sequences containing the Mal d 1 gene cluster on LG16 allowed to acquire many new findings on number and orientation of genes in the cluster, their physical distances, their regulatory sequences and the presence of other genes or pseudogenes in this genomic region. Three new members were discovered co-localizing with the other Mal d 1 genes of LG16 suggesting that the complexity of the genetic base of allergenicity will increase with new advances. Many retrotranspon elements were also retrieved in this cluster. Due to the developement of molecular markers on the two sequences, the anchoring of the physical and the genetic map of the region has been successfully achieved. Moreover, in Chapter 5 the existence of other loci for the Thaumatine-like protein family in apple (Mal d 2.03 on LG4 and Mal d 2.02 on LG17) respect the one reported up to now was demonstred for the first time. Also one new locus for profilins (Mal d 4.04) was mapped on LG2, close to the Mal d 4.02 locus, suggesting a cluster organization for this gene family, as is well reported for Mal d 1 family. Secondly, a methodological approach was used to set up an highly specific tool to discriminate and quantify the expression of each Mal d 1 allergen gene (task of Chapter 2). In aprticular, a set of 20 Mal d 1 gene specific primer pairs for the quantitative Real time PCR technique was validated and optimized. As a first application, this tool was used on leaves and fruit tissues of the cultivar Florina in order to identify the Mal d 1 allergen genes that are expressed in different tissues. The differential expression retrieved in this study revealed a tissue-specificity for some Mal d 1 genes: 10/20 Mal d 1 genes were expressed in fruits and, indeed, probably more involved in the allergic reactions; while 17/20 Mal d 1 genes were expressed in leaves challenged with the fungus Venturia inaequalis and therefore probably interesting in the study of the plant defense mechanism. In Chapter 3 the specific expression levels of the 10 Mal d 1 isoallergen genes, found to be expressed in fruits, were studied for the first time in skin and flesh of apples of different genotypes. A complex gene expression profile was obtained due to the high gene-, tissue- and genotype-variability. Despite this, Mal d 1.06A and Mal d 1.07 expression patterns resulted particularly associated with the degree of allergenicity of the different cultivars. They were not the most expressed Mal d 1 genes in apple but here it was hypotized a relevant importance in the determination of allergenicity for both qualitative and quantitative aspects of the Mal d 1 gene expression levels. In Chapter 4 a clear modulation for all the 17 PR-10 genes tested in young leaves of Florina after challenging with the fungus V. inaequalis have been reported but with a peculiar expression profile for each gene. Interestingly, all the Mal d 1 genes resulted up-regulated except Mal d 1.10 that was down-regulated after the challenging with the fungus. The differences in direction, timing and magnitude of induction seem to confirm the hypothesis of a subfunctionalization inside the gene family despite an high sequencce and structure similarity. Moreover, a modulation of PR-10 genes was showed both in compatible (Gala-V. inaequalis) and incompatible (Florina-V. inaequalis) interactions contribute to validate the hypothesis of an indirect role for at least some of these proteins in the induced defense responses. Finally, a certain modulation of PR-10 transcripts retrieved also in leaves treated with water confirm their abilty to respond also to abiotic stress. To conclude, the genomic approach used here allowed to create a comprehensive inventory of all the genes of allergen families, especially in the case of extended gene families like Mal d 1. This knowledge can be considered a basal prerequisite for many further studies. On the other hand, the specific transcriptional approach make it possible to evaluate the Mal d 1 genes behavior on different samples and conditions and therefore, to speculate on their involvement on apple allergenicity process. Considering the double nature of Mal d 1 proteins, as apple allergens and as PR-10 proteins, the gene expression analysis upon the attack of the fungus created the base for unravel the Mal d 1 biological functions. In particular, the knowledge acquired in this work about the PR-10 genes putatively more involved in the specific Malus-V. inaequalis interaction will be helpful, in the future, to drive the apple breeding for hypo-allergenicity genotype without compromise the mechanism of response of the plants to stress conditions. For the future, the survey of the differences in allergenicity among cultivars has to be be thorough including other genotypes and allergic patients in the tests. After this, the allelic diversity analysis with the high and low allergenic cultivars on all the allergen genes, in particular on the ones with transcription levels correlated to allergencity, will provide the genetic background of the low ones. This step from genes to alleles will allow the develop of molecular markers for them that might be used to effectively addressed the apple breeding for hypo-allergenicity. Another important step forward for the study of apple allergens will be the use of a specific proteomic approach since apple allergy is a multifactor-determined disease and only an interdisciplinary and integrated approach can be effective for its prevention and treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L’attività di ricerca della presente tesi di dottorato ha riguardato sistemi tribologici complessi di interesse industriale per i quali sono stati individuati, mediante failure analysis, i meccanismi di usura dominanti. Per ciascuno di essi sono state studiate soluzioni migliorative sulla base di prove tribologiche di laboratorio. Nella realizzazione di maglie per macchine movimentazione terra sono ampiamente utilizzati i tradizionali acciai da bonifica. La possibilità di utilizzare i nuovi microlegati a medio tenore di carbonio, consentirebbe una notevole semplificazione del ciclo produttivo e benefici in termini di costi. Una parte della tesi ha riguardato lo studio del comportamento tribologico di tali acciai. E’ stato anche affrontato lo studio tribologico di motori idraulici, con l’obiettivo di riuscire a migliorarne la resistenza ad usura e quindi la vita utile. Sono state eseguite prove a banco, per valutare i principali meccanismi di usura, e prove di laboratorio atte a riprodurre le reali condizioni di utilizzo, valutando tecniche di modificazione superficiale che fossero in grado di ridurre l’usura dei componenti. Sono state analizzate diverse tipologie di rivestimenti Thermal Spray in termini di modalità di deposizione (AFS-APS) e di leghe metalliche depositate (Ni,Mo,Cu/Al). Si sono infine caratterizzati contatti tribologici nel settore del packaging, dove l’utilizzo di acciai inox austenitici è in alcuni casi obbligatorio. L’acciaio inossidabile AISI 316L è ampiamente utilizzato in applicazioni in cui siano richieste elevate resistenze alla corrosione, tuttavia la bassa resistenza all’usura, ne limitano l’impiego in campo tribologico. In tale ambito, è stata analizzata una problematica tribologica relativa a macchine automatiche per il dosaggio di polveri farmaceutiche. Sono state studiate soluzioni alternative che hanno previsto sia la completa sostituzione dei materiali della coppia tribologica, sia l’individuazione di tecniche di modificazione superficiale innovative quali la cementazione a bassa temperatura anche seguita dalla deposizione di un rivestimento di carbonio amorfo idrogenato a-C:H

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To assess the biological and technical complication rates of single crowns on vital teeth (SC-V), endodontically treated teeth without post and core (SC-E), with a cast post and core (SC-PC) and on implants (SC-I). Material and methods: From 392 patients with chronic periodontitis treated and documented by graduate students during the period from 1978 to 2002, 199 were reexamined during 2005 for this retrospective cohort study, and 64 of these patients were treated with SCs. Statistical analysis included Kaplan–Meier survival functions and event rates per 100 years of object-time. Poisson regression was used to compare the four groups of crowns with respect to the incidence rate ratio of failures, and failures and complications combined over 10 years and the entire observation period. Results: Forty-one (64%) female and 23 (36%) male patients participated in the reexamination. At the time of seating the crowns, the mean patient age was 46.8 (range 24–66.3) years. One hundred and sixty-eight single unit crowns were incorporated. Their mean follow-up time was 11.8 (range 0.8–26.4) years. During the time of observation, 22 biological and 11 technical complications occurred; 19 SC were lost. The chance for SC-V (56) to remain free of any failure or complication was 89.3% (95% confidence interval [CI] 76.1–95.4) after 10 years, 85.8% (95% CI 66–94.5) for SC-E (34), 75.9% for SC-PC (39), (95% CI 58.8–86.7) and 66.2% (95% CI 45.1–80.7) for SC-I (39). Over 10 years, 95% of SC-I remained free of failure and demonstrated a cumulative incidence of failure or complication of 34%. Compared with SC-E, SC-I were 3.5 times more likely to yield failures or complications and SC-PC failed 1.7 times more frequently than did SC-E. SC-V had the lowest rate of failures or complications over the 10 years. Conclusions: While SCs on vital teeth have the best prognosis, those on endodontically treated teeth have a slightly poorer prognosis over 10 years. Crowns on teeth with post and cores and implant-supported SCs displayed the highest incidence of failures and complications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Diverse psychological factors are involved in the pathophysiology of stress. In order to devise effective intervention strategies, it is important to elucidate which factors play the most important role in the association between psychological stress and exacerbation of Crohn's disease (CD). We hypothesized that the association between perceived stress and exacerbation of CD would remain after removal of mood and anxiety components, which are largely involved in stress perception. METHODS: In all, 468 adults with CD were recruited and followed in different hospitals and private practices of Switzerland for 18 months. At inclusion, patients completed the Perceived Stress Questionnaire and anxiety and depression were assessed using the Hospital Anxiety and Depression Scale. During the follow-up, gastroenterologists assessed whether patients presented with a CD exacerbation. By means of binary logistic regression analysis, we estimated the factor by which one standard deviation of perceived stress would increase the odds of exacerbation of CD with and without controlling for anxiety and depression. RESULTS: The odds of exacerbation of CD increased by 1.85 times (95% confidence interval 1.43-2.40, P < 0.001) for 1 standard deviation of perceived stress. After removing the anxiety and depression components, the residuals of perceived stress were no longer associated with exacerbation of CD. CONCLUSIONS: The association between perceived stress and exacerbation of CD was fully attributable to the mood components, specifically anxiety and depression. Future interventional studies should evaluate the treatment of anxiety and depression as a strategy for potential prevention of CD exacerbations. (Inflamm Bowel Dis 2011;).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Altered pressure in the developing left ventricle (LV) results in altered morphology and tissue material properties. Mechanical stress and strain may play a role in the regulating process. This study showed that confocal microscopy, three-dimensional reconstruction, and finite element analysis can provide a detailed model of stress and strain in the trabeculated embryonic heart. The method was used to test the hypothesis that end-diastolic strains are normalized after altered loading of the LV during the stages of trabecular compaction and chamber formation. Stage-29 chick LVs subjected to pressure overload and underload at stage 21 were reconstructed with full trabecular morphology from confocal images and analyzed with finite element techniques. Measured material properties and intraventricular pressures were specified in the models. The results show volume-weighted end-diastolic von Mises stress and strain averaging 50–82% higher in the trabecular tissue than in the compact wall. The volume-weighted-average stresses for the entire LV were 115, 64, and 147Pa in control, underloaded, and overloaded models, while strains were 11, 7, and 4%; thus, neither was normalized in a volume-weighted sense. Localized epicardial strains at mid-longitudinal level were similar among the three groups and to strains measured from high-resolution ultrasound images. Sensitivity analysis showed changes in material properties are more significant than changes in geometry in the overloaded strain adaptation, although resulting stress was similar in both types of adaptation. These results emphasize the importance of appropriate metrics and the role of trabecular tissue in evaluating the evolution of stress and strain in relation to pressure-induced adaptation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thrombophilia has been associated with pregnancy complications and recurrent miscarriage. The aim of this systematic review was to evaluate the controversial association between thrombophilia and failures of assisted reproduction technology (ART). A systematic search of the literature for studies reporting on thrombophilia in women undergoing ART up to April 2011 yielded 33 studies (23 evaluating anti-phospholipid antibodies, 5 inherited thrombophilia, and 5 both) involving 6092 patients. Overall, methodologic quality of the studies was poor. Combined results from case-control studies showed that factor V Leiden was significantly more prevalent among women with ART failure compared with fertile parous women or those achieving pregnancy after ART (odds ratio = 3.08; 95% confidence interval, 1.77-5.36). The prothrombin mutation, methylenetetrahydrofolate reductase mutation, deficiency of protein S, protein C, or anti-thrombin were all not associated with ART failure. Women with ART failure tested more frequently positive for anti-phospholipids antibodies (odds ratio = 3.33; 95% confidence interval, 1.77-6.26) with evidence of high degree of between-study heterogeneity (I(2) = 75%; P < .00001). Prospective cohort studies did not show significant associations between thrombophilia and ART outcomes. Although case-control studies suggest that women experiencing ART failures are more frequently positive for factor V Leiden and anti-phospholipid antibodies, the evidence is inconclusive and not supported by cohort studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of self-etch primers has increased steadily because of their time savings and greater simplicity; however, overall benefits and potential disadvantages and harms have not been assessed systematically. In this study, we reviewed randomized controlled trials to assess the risk of attachment failure, bonding time, and demineralization adjacent to attachments between 1-stage (self-etch) and 2-stage (acid etch) bonding in orthodontic patients over a minimum follow-up period of 12 months.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This systematic review and meta-analysis compared the efficacy of different anthracyclines and anthracycline dosing schedules for induction therapy in acute myeloid leukaemia in children and adults younger than 60 years of age. Twenty-nine randomized controlled trials were eligible for inclusion in the review. Idarubicin (IDA), in comparison to daunorubicin (DNR), reduced remission failure rates (risk ratio (RR) 0·81; 95% confidence interval (CI), 0·66-0·99; P = 0·04), but did not alter rates of early death or overall mortality. Superiority of IDA for remission induction was limited to studies with a DNR/IDA dose ratio <5 (ratio <5: RR 0·65; 95% CI, 0·51-0·81; P < 0·001; ratio ≥5: RR 1·03; 95% CI, 0·91-1·16; P = 0·63). Higher-dose DNR, compared to lower-dose DNR, was associated with reduced rates for remission failure (RR 0·75; 95% CI, 0·60-0·94; P = 0·003) and overall mortality (RR 0·83; 95% CI, 0·75-0·93; P < 0·001), but not for early death. Comparisons of several other anthracycline derivates did not reveal significant differences in outcomes. Survival estimates in adults suggest that both high-dose DNR (90 mg/m(2) daily × 3 or 50 mg/m(2) daily × 5) and IDA (12 mg/m(2) daily × 3) can achieve 5-year survival rates of between 40 and 50 percent.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Shear-wave splitting can be a useful technique for determining crustal stress fields in volcanic settings and temporal variations associated with activity. Splitting parameters were determined for a subset of local earthquakes recorded from 2000-2010 at Yellowstone. Analysis was automated using an unsupervised cluster analysis technique to determine optimum splitting parameters from 270 analysis windows for each event. Six stations clearly exhibit preferential fast polarization values sub-orthogonal to the direction of minimum horizontal compression. Yellowstone deformation results in a local crustal stress field differing from the regional field dominated by NE-SW extension, and fast directions reflect this difference rotating around the caldera maintaining perpendicularity to the rim. One station exhibits temporal variations concordant with identified periods of caldera subsidence and uplift. From splitting measurements, we calculated a crustal anisotropy of ~17-23% and crack density ~0.12-0.17 possibly resulting from stress-aligned fluid filled microcracks in the upper crust and an active hydrothermal system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: This study tested whether feelings of personal control over one's life circumstances (i.e., personal mastery) would attenuate the relations between stress (i.e., negative life events and caregiving distress) and Plasminogen Activator Inhibitor (PAI)-1 antigen, an inhibitor of fibrinolysis implicated in the development of cardiovascular disease. DESIGN: Seventy-one spousal dementia caregivers were assessed for plasma levels of PAI-1 antigen, negative life events, caregiver distress, and feelings of personal mastery. Regression analysis was used to determine if personal mastery moderated the relations between stress (i.e., life stress and caregiving distress) and PAI-1 antigen levels. MAIN OUTCOME MEASURE: Plasminogen activator inhibitor (PAI)-1 antigen in plasma. RESULTS: After controlling for other factors associated with PAI-1 antigen levels, negative life events were positively associated with plasma PAI-1 antigen concentrations in participants low in personal mastery (beta = .31; p = .050) but not in individuals high in personal mastery (beta = .22; p = .184). The moderating effect of mastery on the relations between caregiving distress and PAI-1 antigen did not reach statistical significance (p = .091). CONCLUSIONS: These data suggest that mastery may protect individuals from some of the alterations in hemostatic factors that have been linked to cardiovascular risk.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM: The purpose of this study was to systematically review the literature on the survival rates of palatal implants, Onplants((R)), miniplates and mini screws. MATERIAL AND METHODS: An electronic MEDLINE search supplemented by manual searching was conducted to identify randomized clinical trials, prospective and retrospective cohort studies on palatal implants, Onplants((R)), miniplates and miniscrews with a mean follow-up time of at least 12 weeks and of at least 10 units per modality having been examined clinically at a follow-up visit. Assessment of studies and data abstraction was performed independently by two reviewers. Reported failures of used devices were analyzed using random-effects Poisson regression models to obtain summary estimates and 95% confidence intervals (CI) of failure and survival proportions. RESULTS: The search up to January 2009 provided 390 titles and 71 abstracts with full-text analysis of 34 articles, yielding 27 studies that met the inclusion criteria. In meta-analysis, the failure rate for Onplants((R)) was 17.2% (95% CI: 5.9-35.8%), 10.5% for palatal implants (95% CI: 6.1-18.1%), 16.4% for miniscrews (95% CI: 13.4-20.1%) and 7.3% for miniplates (95% CI: 5.4-9.9%). Miniplates and palatal implants, representing torque-resisting temporary anchorage devices (TADs), when grouped together, showed a 1.92-fold (95% CI: 1.06-2.78) lower clinical failure rate than miniscrews. CONCLUSION: Based on the available evidence in the literature, palatal implants and miniplates showed comparable survival rates of >or=90% over a period of at least 12 weeks, and yielded superior survival than miniscrews. Palatal implants and miniplates for temporary anchorage provide reliable absolute orthodontic anchorage. If the intended orthodontic treatment would require multiple miniscrew placement to provide adequate anchorage, the reliability of such systems is questionable. For patients who are undergoing extensive orthodontic treatment, force vectors may need to be varied or the roots of the teeth to be moved may need to slide past the anchors. In this context, palatal implants or miniplates should be the TADs of choice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION Light cure of resin-based adhesives is the mainstay of orthodontic bonding. In recent years, alternatives to conventional halogen lights offering reduced curing time and the potential for lower attachment failure rates have emerged. The relative merits of curing lights in current use, including halogen-based lamps, light-emitting diodes (LEDs), and plasma arc lights, have not been analyzed systematically. In this study, we reviewed randomized controlled trials and controlled clinical trials to assess the risks of attachment failure and bonding time in orthodontic patients in whom brackets were cured with halogen lights, LEDs, or plasma arc systems. METHODS Multiple electronic database searches were undertaken, including MEDLINE, EMBASE, and the Cochrane Oral Health Group's Trials Register, CENTRAL. Language restrictions were not applied. Unpublished literature was searched on ClinicalTrials.gov, the National Research Register, Pro-Quest Dissertation Abstracts, and Thesis database. Search terms included randomized controlled trial, controlled clinical trial, random allocation, double blind method, single blind method, orthodontics, LED, halogen, bond, and bracket. Authors of primary studies were contacted as required, and reference lists of the included studies were screened. RESULTS Randomized controlled trials and clinical controlled trials directly comparing conventional halogen lights, LEDs, or plasma arc systems involving patients with full arch, fixed, or bonded orthodontic appliances (not banded) with follow-up periods of a minimum of 6 months were included. Using predefined forms, 2 authors undertook independent extraction of articles; disagreements were resolved by discussion. The assessment of the risk of bias of the randomized controlled trials was based on the Cochrane Risk of Bias tool. Ten studies met the inclusion criteria; 2 were excluded because of high risk of bias. In the comparison of bond failure risk with halogen lights and plasma arc lights, 1851 brackets were included in both groups. Little statistical heterogeneity was observed in this analysis (I(2) = 4.8%; P = 0.379). There was no statistical difference in bond failure risk between the groups (OR, 0.92; 95% CI, 0.68-1.23; prediction intervals, 0.54, 1.56). Similarly, no statistical difference in bond failure risk was observed in the meta-analysis comparing halogen lights and LEDs (OR, 0.96; 95% CI, 0.64-1.44; prediction intervals, 0.07, 13.32). The pooled estimates from both comparisons were OR, 0.93; 95% CI, 0.74-1.17; and prediction intervals, 0.69, 1.17. CONCLUSIONS There is no evidence to support the use of 1 light cure type over another based on risk of attachment failure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE Clinical studies related to the long-term outcomes with implant-supported reconstructions are still sparse. The aim of this 10-year retrospective study was to assess the rate of mechanical/technical complications and failures with implant supported fixed dental prostheses (FDPs) and single crowns (SCs) in a large cohort of partially edentulous patients. MATERIALS AND METHODS The comprehensive multidisciplinary examination consisted of a medical/dental history, clinical examination, and a radiographic analysis. Prosthodontic examination evaluated the implant-supported reconstructions for mechanical/technical complications and failures, occlusal analysis, presence/absence of attrition, and location, extension, and retention type. RESULTS Out of three hundred ninety seven fixed reconstructions in three hundred three patients, two hundred sixty eight were SCs and one hundred twenty seven were FDPs. Of these three hundred ninety seven implant-supported reconstructions, 18 had failed, yielding a failure rate of 4.5% and a survival rate of 95.5% after a mean observation period of 10.75 years (range: 8.4-13.5 years). The most frequent complication was ceramic chipping (20.31%) followed by occlusal screw loosening (2.57%) and loss of retention (2.06%). No occlusal screw fracture, one abutment loosening, and two abutment fractures were noted. This resulted in a total mechanical/technical complication rate of 24.7%. The prosthetic success rate over a mean follow-up time of 10.75 years was 70.8%. Generalized attrition and FDPs were associated with statistically significantly higher rates of ceramic fractures when compared with SCs. Cantilever extensions, screw retention, anterior versus posterior, and gender did not influence the chipping rate. CONCLUSIONS After a mean exposure time of 10.75 years, high survival rates for reconstructions supported by Sand-blasted Large-grit Acid-etched implants can be expected. Ceramic chipping was the most frequent complication and was increased in dentitions with attrition and in FDPs compared with SCs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE The objective of this study was to evaluate stiffness, strength, and failure modes of monolithic crowns produced using computer-aided design/computer-assisted manufacture, which are connected to diverse titanium and zirconia abutments on an implant system with tapered, internal connections. MATERIALS AND METHODS Twenty monolithic lithium disilicate (LS2) crowns were constructed and loaded on bone level-type implants in a universal testing machine under quasistatic conditions according to DIN ISO 14801. Comparative analysis included a 2 × 2 format: prefabricated titanium abutments using proprietary bonding bases (group A) vs nonproprietary bonding bases (group B), and customized zirconia abutments using proprietary Straumann CARES (group C) vs nonproprietary Astra Atlantis (group D) material. Stiffness and strength were assessed and calculated statistically with the Wilcoxon rank sum test. Cross-sections of each tested group were inspected microscopically. RESULTS Loaded LS2 crowns, implants, and abutment screws in all tested specimens (groups A, B, C, and D) did not show any visible fractures. For an analysis of titanium abutments (groups A and B), stiffness and strength showed equally high stability. In contrast, proprietary and nonproprietary customized zirconia abutments exhibited statistically significant differences with a mean strength of 366 N (Astra) and 541 N (CARES) (P < .05); as well as a mean stiffness of 884 N/mm (Astra) and 1,751 N/mm (CARES) (P < .05), respectively. Microscopic cross-sections revealed cracks in all zirconia abutments (groups C and D) below the implant shoulder. CONCLUSION Depending on the abutment design, prefabricated titanium abutment and proprietary customized zirconia implant-abutment connections in conjunction with monolithic LS2 crowns had the best results in this laboratory investigation.