930 resultados para standard combustion enthalpy
Resumo:
Background: The use of three-dimensional rotational angiography (3D-RA) to assess patients with congenital heart diseases appears to be a promising technique despite the scarce literature available. Objectives: The objective of this study was to describe our initial experience with 3D-RA and to compare its radiation dose to that of standard two-dimensional angiography (2D-SA). Methods: Between September 2011 and April 2012, 18 patients underwent simultaneous 3D-RA and 2D-SA during diagnostic cardiac catheterization. Radiation dose was assessed using the dose-area-product (DAP). Results: The median patient age and weight were 12.5 years and 47.5 Kg, respectively. The median DAP of each 3D-RA acquisition was 1093µGy.m2 and 190µGy.m2 for each 2D-SA acquisition (p<0.01). In patients weighing more than 45Kg (n=7), this difference was attenuated but still significant (1525 µGy.m2 vs.413µGy.m2, p=0.01). No difference was found between one 3D-RA and three 2D-SA (1525µGy.m2 vs.1238 µGy.m2, p = 0.575) in this population. This difference was significantly higher in patients weighing less than 45Kg (n=9) (713µGy.m2 vs.81µGy.m2, P = 0.008), even when comparing one 3D-RA with three 2D-SA (242µGy.m2, respectively, p<0.008). 3D-RA was extremely useful for the assessment of conduits of univentricular hearts, tortuous branches of the pulmonary artery, and aorta relative to 2D-SA acquisitions. Conclusions: The radiation dose of 3D-RA used in our institution was higher than those previously reported in the literature and this difference was more evident in children. This type of assessment is of paramount importance when starting to perform 3D-RA.
Resumo:
Combustion, Coal, Droplet Combustion, Boudouard Reaction
Resumo:
Cross-Flow, Radial Jets Mixing, Temperature Homogenization, Optimization, Combustion Chamber, CFD
Resumo:
Magdeburg, Univ., Fak. für Verfahrens- und Systemtechnik, Diss., 2009
Resumo:
Potential risks of a secondary formation of polychlorinated dibenzodioxins/furans (PCDD/Fs) were assessed for two cordierite-based, wall-through diesel particulate filters (DPFs) for which soot combustion was either catalyzed with an iron- or a copper-based fuel additive. A heavy duty diesel engine was used as test platform, applying the eight-stage ISO 8178/4 C1 cycle. DPF applications neither affected the engine performance, nor did they increase NO, NO2, CO, and CO2 emissions. The latter is a metric for fuel consumption. THC emissions decreased by about 40% when deploying DPFs. PCDD/F emissions, with a focus on tetra- to octachlorinated congeners, were compared under standard and worst case conditions (enhanced chlorine uptake). The iron-catalyzed DPF neither increased PCDD/F emissions, nor did it change the congener pattern, even when traces of chlorine became available. In case of copper, PCDD/F emissions increased by up to 3 orders of magnitude from 22 to 200 to 12 700 pg I-TEQ/L with fuels of < 2, 14, and 110 microg/g chlorine, respectively. Mainly lower chlorinated DD/Fs were formed. Based on these substantial effects on PCDD/F emissions, the copper-catalyzed DPF system was not approved for workplace applications, whereas the iron system fulfilled all the specifications of the Swiss procedures for DPF approval (VERT).
Resumo:
Purpose: To investigate the accuracy of 4 clinical instruments in the detection of glaucomatous damage. Methods: 102 eyes of 55 test subjects (Age mean = 66.5yrs, range = [39; 89]) underwent Heidelberg Retinal Tomography (HRTIII), (disc area<2.43); and standard automated perimetry (SAP) using Octopus (Dynamic); Pulsar (TOP); and Moorfields Motion Displacement Test (MDT) (ESTA strategy). Eyes were separated into three groups 1) Healthy (H): IOP<21mmHg and healthy discs (clinical examination), 39 subjects, 78 eyes; 2) Glaucoma suspect (GS): Suspicious discs (clinical examination), 12 subjects, 15 eyes; 3) Glaucoma (G): progressive structural or functional loss, 14 subjects, 20 eyes. Clinical diagnostic precision was examined using the cut-off associated with the p<5% normative limit of MD (Octopus/Pulsar), PTD (MDT) and MRA (HRT) analysis. The sensitivity, specificity and accuracy were calculated for each instrument. Results: See table Conclusions: Despite the advantage of defining glaucoma suspects using clinical optic disc examination, the HRT did not yield significantly higher accuracy than functional measures. HRT, MDT and Octopus SAP yielded higher accuracy than Pulsar perimetry, although results did not reach statistical significance. Further studies are required to investigate the structure-function correlations between these instruments.
Resumo:
Estudi elaborat a partir d’una estada a la Universität Karlsruhe entre gener i maig del 2007. Les biblioteques d’estructures de dades defineixen interfícies i implementen algorismes i estructures de dades fonamentals. Un exemple n’és la Satandard Template Library (STL ), que forma part del llenguatge de programació C++. En el marc d’una tesi, s’està treballant per obtenir implementacions més eficients i/o versàtils d’alguns components de la STL. Per a fer-ho s’utilitzen tècniques de la enginyeria d’algorismes. En particular, s’integra el coneixement de la comunitat algorítmica i es té en consideració la tecnologia existent. L’acció durant l’estada s’ha emmarcat en el desenvolupament la Multi Core STL (MCSTL ). La MCSTL és una implementació paral•lela de la STL per a màquines multi-core. Les màquines multi-core són actualment l’únic tipus de màquina disponible al mercat. Per tant, tot i que el paral•lelisme obtingut no sigui òptim, és preferible a tenir els processadors esperant, ja que , la tendència és que el nombre de processadors per computador augmenti.
Resumo:
A novel approach to measure carbon dioxide (CO2) in gaseous samples, based on a precise and accurate quantification by (13)CO2 internal standard generated in situ is presented. The main goal of this study was to provide an innovative headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable in the routine determination of CO2. The main drawback of the GC methods discussed in the literature for CO2 measurement is the lack of a specific internal standard necessary to perform quantification. CO2 measurement is still quantified by external calibration without taking into account analytical problems which can often occur considering gaseous samples. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate in situ an internal labeled standard gas ((13)CO2) on the basis of the stoichiometric formation of CO2 by the reaction of hydrochloric acid (HCl) with sodium hydrogen carbonate (NaH(13)CO3). This method allows a precise measurement of CO2 concentration and was validated on various human postmortem gas samples in order to study its efficiency.
Resumo:
The monetary policy reaction function of the Bank of England is estimated by the standard GMM approach and the ex-ante forecast method developed by Goodhart (2005), with particular attention to the horizons for inflation and output at which each approach gives the best fit. The horizons for the ex-ante approach are much closer to what is implied by the Bank’s view of the transmission mechanism, while the GMM approach produces an implausibly slow adjustment of the interest rate, and suffers from a weak instruments problem. These findings suggest a strong preference for the ex-ante approach.
Resumo:
The monetary policy reaction function of the Bank of England is estimated by the standard GMM approach and the ex-ante forecast method developed by Goodhart (2005), with particular attention to the horizons for inflation and output at which each approach gives the best fit. The horizons for the ex-ante approach are much closer to what is implied by the Bank’s view of the transmission mechanism, while the GMM approach produces an implausibly slow adjustment of the interest rate, and suffers from a weak instruments problem. These findings suggest a strong preference for the ex-ante approach.
Resumo:
This paper uses data on the world's copper mining industry to measure the impact on efficiency of the adoption of the ISO 14001 environmental standard. Anecdotal and case study literature suggests that firms are motivated to adopt this standard so as to achieve greater efficiency through changes in operating procedures and processes. Using plant level panel data from 1992-2007 on most of the world's industrial copper mines, the study uses stochastic frontier methods to investigate the effects of ISO adoption. The variety of models used in this study find that adoption either tends to improve efficiency or has no impact on efficiency, but no evidence is found that ISO adoption decreases efficiency.
Resumo:
A cardiac-triggered free-breathing three-dimensional (3D) balanced fast field-echo projection renal magnetic resonance (MR) angiographic sequence was investigated for in-stent lumen visualization of a dedicated metallic renal artery stent. Fourteen prototype stents were deployed in the renal arteries of six pigs (in two pigs, three stents were deployed). Projection renal MR angiography was compared with standard contrast material-enhanced 3D breath-hold MR angiography. Artifact-free in-stent lumen visualization was achieved with both projection MR angiography and contrast-enhanced MR angiography. These promising results warrant further studies for visualization of in-stent restenosis.
Predictors of weight change in sedentary smokers receiving a standard smoking cessation intervention
Resumo:
L'arrêt de la cigarette est généralement associé à une prise de poids. Celle-ci peut menacer la motivation des fumeurs à s'engager dans un processus d'arrêt du tabac et constitue un motif de rechute. L'ordre de grandeur et la cinétique de la prise de poids liée à une tentative d'arrêt chez les fumeurs pris en charge selon les recommandations cliniques actuelles est peu décrite dans la littérature médicale. Le but de cette étude était de quantifier cette prise de poids, d'en déterminer la cinétique ainsi que les facteurs qui l'influencent, chez des fumeurs sédentaires bénéficiant d'une intervention d'aide à l'arrêt du tabac individualisée, composée de conseils individuels et d'une substitution nicotinique associant plusieurs modes d'administration. Nous avons analysé des données récoltées durant un essai clinique randomisé contrôlé au cours duquel était étudié l'impact d'une activité physique modérée sur les taux d'arrêt du tabac après un an chez des fumeurs sédentaires. Nous avons modélisé l'évolution du poids de l'ensemble des participants au cours du temps, selon la technique statistique des « modèles mixtes longitudinaux ». En séparant les périodes d'abstinence de la cigarette de celles de rechute et de l'utilisation reportée de substituts nicotiniques. Cette approche nous a permis de prendre en compte chaque participant à l'étude, par opposition à un modèle plus simple qui séparerait les sujets abstinents de ceux qui rechutent à n'importe quel moment de la période de suivi. Nous avons également ajusté ces modèles pour l'âge, le sexe, le niveau de dépendance à la nicotine et le niveau de formation des participants. Parmi l'ensemble des participants, nous avons noté une augmentation du poids durant les trois premiers mois de l'intervention, suivie d'une stabilisation. Au total, la prise de poids moyenne s'est élevée à 3.3 kg pour les femmes et 3.9 kg pour les hommes. Durant les périodes d'abstinence, les caractéristiques suivantes étaient associées à la prise de poids : sexe masculin et forte dépendance nicotinique. Un âge supérieur à 43 ans était associé à une prise de poids également durant les périodes de rechute. Nous avons observé une tendance, non statistiquement significative, vers une réduction de la prise des poids avec l'utilisation de substituts nicotiniques. Notre étude apporte de nouvelles données sur l'évolution du poids chez les fumeurs sédentaires qui bénéficient d'une intervention d'aide à l'arrêt du tabac. Ils prennent donc du poids, de manière modérée et limitée aux premiers mois. Parmi eux, les hommes, les individus les plus dépendants à la nicotine et les plus âgés doivent s'attendre à une prise de poids supérieure à la moyenne.
Application of standard and refined heat balance integral methods to one-dimensional Stefan problems
Resumo:
The work in this paper concerns the study of conventional and refined heat balance integral methods for a number of phase change problems. These include standard test problems, both with one and two phase changes, which have exact solutions to enable us to test the accuracy of the approximate solutions. We also consider situations where no analytical solution is available and compare these to numerical solutions. It is popular to use a quadratic profile as an approximation of the temperature, but we show that a cubic profile, seldom considered in the literature, is far more accurate in most circumstances. In addition, the refined integral method can give greater improvement still and we develop a variation on this method which turns out to be optimal in some cases. We assess which integral method is better for various problems, showing that it is largely dependent on the specified boundary conditions.