216 resultados para stains


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Superficial stains and irregularities of the enamel are generally what prompt patients to seek dental intervention to improve their smile. These stains or defects may be due to hypoplasia, amelogenesis imperfecta, mineralized white spots, or fluorosis, for which enamel microabrasion is primarily indicated. Enamel microabrasion involves the use of acidic and abrasive agents, such as with 37% phosphoric acid and pumice or 6% hydrochloric acid and silica, applied to the altered enamel surface with mechanical pressure from a rubber cup coupled to a rotatory mandrel of a low-rotation micromotor. If necessary, this treatment can be safely combined with bleaching for better esthetic results. Recent studies show that microabrasion is a conservative treatment when the enamel wear is minimal and clinically imperceptible. The most important factor contributing to the success of enamel microabrasion is the depth of the defect, as deeper, opaque stains, such as those resulting from hypoplasia, cannot be resolved with microabrasion, and require a restorative approach. Surface enamel alterations that result from microabrasion, such as roughness and microhardness, are easily restored by saliva. Clinical studies support the efficacy and longevity of this safe and minimally invasive treatment. The present article presents the clinical and scientific aspects concerning the microabrasion technique, and discusses the indications for and effects of the treatment, including recent works describing microscopic and clinical evaluations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This is a clinical case report of a patient who presented with dental stains in the buccal and proximal aspects of the anterior teeth. Buccal stains were removed using the enamel microabrasion technique, and vital tooth bleaching with carbamide peroxide was also performed. Restorative procedures employing composite resin were done for a better result in the proximal aspect of teeth. Clinical significance: The authors observed the combination of these esthetic techniques improved the patient's smile. Today, dental esthetics attempts to imitate natural teeth by making them white, well-shaped, and aligned with no spots. This has enabled the development of several esthetic techniques, such as microabrasion to remove dental enamel surface stains and surface irregularities,1-6 and vital tooth bleaching to treat yellowish teeth.7 The enamel microabrasion technique uses different abrasive agents associated with chemical solutions,1,2,4,6 allowing the removal of intrinsic, hard-texture stains, and different coloring spots on the enamel surface, as well as correction of irregularities on the dental buccal surface.1,8 The various microabrasive products include the Opalustre® (Ultradent Products, http://www.ultradent.com)or Prema® Compound (Premier Dental Products, http://www.premusa.com), a low-concentration hydrochloric acid product associated with silica microparticles that is certainly effective for microabrasion technique,4,6,9,10 providing a good safety profile for the patient and professional. The microabrasion technique also promotes micro-reduction on the adamantine surface.4,5,10 In some cases, after its completion, microabrasion may cause teeth to become darker or yellowish because of the thinner remaining enamel surface, leading to more evident observation of the dentinal tissue, which in general determines tooth color. In these clinical conditions, correction of the color pattern of dental elements can be obtained with carbamide peroxide products applied in custom trays, such as the bleaching products Whiteness Perfect at 10% or 16% (FGM Productos Odontologicos, http://www.fgm.ind.br) or Opalescence® at 10% or 15% (Ultradent Products), with a considerable margin of clinical success, provided it is well indicated, well performed, and supervised by the professional.4,6,9,10 Considering all the aforementioned aspects, the authors present a clinical case about a dental-enamel microabrasion technique used to remove buccal enamel surface stains associated with dental vital bleaching and restorative procedures in the proximal aspect of anterior teeth. - See more at: https://www.dentalaegis.com/cced/2010/08/different-esthetic-techniques-used-in-combination-to-recover-the-smile#sthash.McFoH7El.dpuf

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Enamel microabrasion can eliminate enamel irregularities and discoloration defects, improving the appearance of teeth. This article presents the latest treatment protocol of enamel microabrasion to remove stains on the enamel surface. It has been verified that teeth submitted to microabrasion acquire a yellowish color because of the thinness of the remaining enamel, revealing the color of dentinal tissue to a greater degree. In these clinical conditions, correction of the color pattern of these teeth can be obtained with a considerable margin of clinical success using products containing carbamide peroxide in custom trays. Thus, patients can benefit from combined enamel microabrasion/tooth bleaching therapy, which yields attractive cosmetic results. Esthetics plays an important role in contemporary dentistry, especially because the media emphasizes beauty and health. Currently, in many countries, a smile is considered beautiful if it imitates a natural appearance, with clear, well-aligned teeth and defined anatomical shapes.1-3 Enamel microabrasion is one technique that can be used to correct discolored enamel. This technique has been elucidated and strongly advocated by Croll and Cavanaugh since 1986,4 and by other investigators1,2,5-13 who suggested mechanical removal of enamel stains using acidic substances in conjunction with abrasive agents. Enamel microabrasion is indicated to remove intrinsic stains of any color and of hard texture, and is contraindicated for extrinsic stains, dentinal stains, for patients with deficient labial seals, and in cases where there is no possibility to place a rubber dam adequately during the microabrasion procedure.1,2 It should be emphasized that enamel microabrasion causes a microreduction on the enamel surface,3,6,10 and, in some cases, teeth submitted to microabrasion may appear a darker or yellowish color because the thin remaining enamel surface can reveal some of the dentinal tissue color. In these situations, according to Haywood and Heymann in 1989,14 correction of the color pattern of teeth can be obtained through the use of whitening products containing carbamide peroxide in custom trays. A considerable margin of clinical success has been shown when diligence to at-home protocols is achieved by the patient and supervised by the professional.3 Considering these possibilities, this article presents the microabrasion technique for removal of stains on dental enamel, followed by tooth bleaching with carbamide peroxide and composite resin restoration, if required.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract: Pyogenic granuloma (PG) is a benign inflammatory lesion, nonneoplastic in nature, which occurs in the oral cavity and skin. This lesion arises in response to various stimuli such as low-grade local irritations, traumatic injury, or hormonal factors. Recently, in some cases, the occurrence of recurrent PGs in skin associated with vascular lesions, such as port-wine stains, has been described. It has been postulated that this association is promoted by arteriovenous anastomoses in the vascular lesions, leading to the development of PG. The authors discuss 2 cases of recurrent PG in patients with a port-wine stain, and the treatment options adopted.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Strongyloidiasis is an intestinal parasitosis with an obligatory pulmonary cycle. A Th2-type immune response is induced and amplifies the cellular response through the secretion of inflammatory mediators. Although this response has been described as being similar to asthma, airway remodeling during pulmonary migration of larvae has not yet been established. The aim of this study was to identify the occurrence of airway remodeling during Strongyloides venezuelensis (S. v.) infection and to determine the ability of dexamethasone treatment to interfere with the mechanisms involved in this process. Rats were inoculated with 9,000 S. v. larvae, treated with dexamethasone (2 mg/kg) and killed at 1, 3, 5, 7, 14 and 21 days. Morphological and morphometric analyzes with routine stains and immunohistochemistry were conducted, and some inflammatory mediators were evaluated using ELISA. Goblet cell hyperplasia and increased bronchiolar thickness, characterized by edema, neovascularization, inflammatory infiltrate, collagen deposition and enlargement of the smooth muscle cell layer were observed. VEGF, IL1-beta and IL-4 levels were elevated throughout the course of the infection. The morphological findings and the immunomodulatory response to the infection were drastically reduced in dexamethasone-treated rats. The pulmonary migration of S. venezuelensis larvae produced a transitory, but significant amount of airway remodeling with a slight residual bronchiolar fibrosis. The exact mechanisms involved in this process require further study. (C) 2012 Elsevier Ireland Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

LipL32 is the most abundant outer membrane protein from pathogenic Leptospira and has been shown to bind extracellular matrix (ECM) proteins as well as Ca2+. Recent crystal structures have been obtained for the protein in the apo-and Ca2+-bound forms. In this work, we produced three LipL32 mutants (D163-168A, Q67A, and S247A) and evaluated their ability to interact with Ca2+ and with ECM glycoproteins and human plasminogen. The D163-168A mutant modifies aspartate residues involved in Ca2+ binding, whereas the other two modify residues in a cavity on the other side of the protein structure. Loss of calcium binding in the D163-D168A mutant was confirmed using intrinsic tryptophan fluorescence, circular dichroism, and thermal denaturation whereas the Q67A and S247A mutants presented the same Ca2+ affinity as the wild-type protein. We then evaluated if Ca2+ binding to LipL32 would be crucial for its interaction with collagen type IV and plasma proteins fibronectin and plasminogen. Surprisingly, the wild-type protein and all three mutants, including the D163-168A variant, bound to these ECM proteins with very similar affinities, both in the presence and absence of Ca2+ ions. In conclusion, calcium binding to LipL32 may be important to stabilize the protein, but is not necessary to mediate interaction with host extracellular matrix proteins.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As várias opções para a realização de tratamentos estéticos conservadores permitem ao profissional a escolha de materiais e técnicas apropriados, que melhor se enquadrem nas características individuais de cada paciente e na realidade de seu consultório. No caso clínico apresentado, a técnica de clareamento dental em consultório com peróxido de hidrogênio a 35% (Total Blanc Office, DFL), ativado com luz híbrida LED/LASER e a microabrasão de esmalte com pasta de acido fosfórico a 37% e pedra pomes, foram associados. Os resultados com o clareamento em consultório são imediatos, de forma que o profissional dispõe de total controle sobre aplicação do gel clareador em áreas e dentes específicos. A microabrasão do esmalte é um tratamento simples e custo relativamente baixo, remove as manchas superficiais do esmalte com preservação de estrutura dental. No caso apresentado, a associação das duas técnicas proporcionou a obtenção de excelente resultado estético em apenas uma sessão de atendimento.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract Background Salivary Glands Malignant Neoplasms (SGMNs) account for 3-6% of head and neck cancers and 0.3% of all cancers. Tumor cells that express CD44 and CD24 exhibit a stem-cell-like behavior. CD44 is the binding site for hyaluronic acid, and CD24 is a receptor that interacts with P-selectin to induce metastasis and tumor progression. The present study aims to evaluate the expression of CD44 and CD24 on SGMNs and correlated these data with several clinicopathologic features. Methods Immunohistochemical stains for CD44 and CD24 were performed on tissue microarrays containing SGMN samples from 69 patients. The CD44, CD24 and CD44/CD24 expression phenotypes were correlated to patient clinicopathologic features and outcome. Results CD44 expression was associated with the primary site of neoplasm (p = 0.046). CD24 was associated with clinical stage III/IV (p = 0.008), T stage (p = 0,27) and lymph node (p = 0,001). The CD44/CD24 profiles were associated with the primary site of injury (p = 0.005), lymph node (p = 0.011) and T stage (p = 0.023). Univariate analysis showed a significant relationship between clinical staging and disease- free survival (p = 0.009), and the overall survival presents relation with male gender (p = 0.011) and metastasis (p = 0.027). Conclusion In summary, our investigation confirms that the clinical stage, in accordance with the literature, is the main prognostic factor for SGMN. Additionally, we have presented some evidence that the analysis of isolated CD44 and CD24 immunoexpression or the two combined markers could give prognostic information associated to clinicopathologic features in SGMN. Virtual Slides The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/1284611098470676.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chemical disinfectants are usually associated with mechanical methods to remove stains and reduce biofilm formation. This study evaluated the effect of disinfectants on release of metal ions and surface roughness of commercially pure titanium, metal alloys, and heat-polymerized acrylic resin, simulating 180 immersion trials. Disk-shaped specimens were fabricated with commercially pure titanium (Tritan), nickel-chromium-molybdenum-titanium (Vi-Star), nickel-chromium (Fit Cast-SB Plus), and nickel-chromium-beryllium (Fit Cast-V) alloys. Each cast disk was invested in the flasks, incorporating the metal disk to the heat-polymerized acrylic resin. The specimens (n=5) were immersed in these solutions: sodium hypochlorite 0.05%, Periogard, Cepacol, Corega Tabs, Medical Interporous, and Polident. Deionized water was used as a control. The quantitative analysis of metal ion release was performed using inductively coupled plasma mass spectrometry (ELAN DRC II). A surface analyzer (Surftest SJ-201P) was used to measure the surface roughness (µm). Data were recorded before and after the immersions and evaluated by two-way ANOVA and Tukey's test (α=0.05). The nickel release proved most significant with the Vi-Star and Fit Cast-V alloys after immersion in Medical Interporous. There was a significant difference in surface roughness of the resin (p=0.011) after immersion. Cepacol caused significantly higher resin roughness. The immersion products had no influence on metal roughness (p=0.388). It could be concluded that the tested alloys can be considered safe for removable denture fabrication, but disinfectant solutions as Cepacol and Medical Interporous tablet for daily denture immersion should be used with caution because it caused greater resin surface roughness and greater ion release, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this thesis, we investigated the evaporation of sessile microdroplets on different solid substrates. Three major aspects were studied: the influence of surface hydrophilicity and heterogeneity on the evaporation dynamics for an insoluble solid substrate, the influence of external process parameters and intrinsic material properties on microstructuring of soluble polymer substrates and the influence of an increased area to volume ratio in a microfluidic capillary, when evaporation is hindered. In the first part, the evaporation dynamics of pure sessile water drops on smooth self-assembled monolayers (SAMs) of thiols or disulfides on gold on mica was studied. With increasing surface hydrophilicity the drop stayed pinned longer. Thus, the total evaporation time of a given initial drop volume was shorter, since the drop surface, through which the evaporation occurs, stays longer large. Usually, for a single drop the volume decreased linearly with t1.5, t being the evaporation time, for a diffusion-controlled evaporation process. However, when we measured the total evaporation time, ttot, for multiple droplets with different initial volumes, V0, we found a scaling of the form V0 = attotb. The more hydrophilic the substrate was, the more showed the scaling exponent a tendency to an increased value up to 1.6. This can be attributed to an increasing evaporation rate through a thin water layer in the vicinity of the drop. Under the assumption of a constant temperature at the substrate surface a cooling of the droplet and thus a decreased evaporation rate could be excluded as a reason for the different scaling exponent by simulations performed by F. Schönfeld at the IMM, Mainz. In contrast, for a hairy surface, made of dialkyldisulfide SAMs with different chain lengths and a 1:1 mixture of hydrophilic and hydrophobic end groups (hydroxy versus methyl group), the scaling exponent was found to be ~ 1.4. It increased to ~ 1.5 with increasing hydrophilicity. A reason for this observation can only be speculated: in the case of longer hydrophobic alkyl chains the formation of an air layer between substrate and surface might be favorable. Thus, the heat transport to the substrate might be reduced, leading to a stronger cooling and thus decreased evaporation rate. In the second part, the microstructuring of polystyrene surfaces by drops of toluene, a good solvent, was investigated. For this a novel deposition technique was developed, with which the drop can be deposited with a syringe. The polymer substrate is lying on a motorized table, which picks up the pendant drop by an upward motion until a liquid bridge is formed. A consecutive downward motion of the table after a variable delay, i.e. the contact time between drop and polymer, leads to the deposition of the droplet, which can evaporate. The resulting microstructure is investigated in dependence of the processes parameters, i.e. the approach and the retraction speed of the substrate and the delay between them, and in dependence of the intrinsic material properties, i.e. the molar mass and the type of the polymer/solvent system. The principal equivalence with the microstructuring by the ink-jet technique was demonstrated. For a high approach and retraction speed of 9 mm/s and no delay between them, a concave microtopology was observed. In agreement with the literature, this can be explained by a flow of solvent and the dissolved polymer to the rim of the pinned droplet, where polymer is accumulated. This effect is analogue to the well-known formation of ring-like stains after the evaporation of coffee drops (coffee-stain effect). With decreasing retraction speed down to 10 µm/s the resulting surface topology changes from concave to convex. This can be explained with the increasing dissolution of polymer into the solvent drop prior to the evaporation. If the polymer concentration is high enough, gelation occurs instead of a flow to the rim and the shape of the convex droplet is received. With increasing delay time from below 0 ms to 1s the depth of the concave microwells decreases from 4.6 µm to 3.2 µm. However, a convex surface topology could not be obtained, since for longer delay times the polymer sticks to the tip of the syringe. Thus, by changing the delay time a fine-tuning of the concave structure is accomplished, while by changing the retraction speed a principal change of the microtopolgy can be achieved. We attribute this to an additional flow inside the liquid bridge, which enhanced polymer dissolution. Even if the pendant drop is evaporating about 30 µm above the polymer surface without any contact (non-contact mode), concave structures were observed. Rim heights as high as 33 µm could be generated for exposure times of 20 min. The concave structure exclusively lay above the flat polymer surface outside the structure even after drying. This shows that toluene is taken up permanently. The increasing rim height, rh, with increasing exposure time to the solvent vapor obeys a diffusion law of rh = rh0  tn, with n in the range of 0.46 ~ 0.65. This hints at a non-Fickian swelling process. A detailed analysis showed that the rim height of the concave structure is modulated, unlike for the drop deposition. This is due to the local stress relaxation, which was initiated by the increasing toluene concentration in the extruded polymer surface. By altering the intrinsic material parameters i.e. the polymer molar mass and the polymer/solvent combination, several types of microstructures could be formed. With increasing molar mass from 20.9 kDa to 1.44 MDa the resulting microstructure changed from convex, to a structure with a dimple in the center, to concave, to finally an irregular structure. This observation can be explained if one assumes that the microstructuring is dominated by two opposing effects, a decreasing solubility with increasing polymer molar mass, but an increasing surface tension gradient leading to instabilities of Marangoni-type. Thus, a polymer with a low molar mass close or below the entanglement limit is subject to a high dissolution rate, which leads to fast gelation compared to the evaporation rate. This way a coffee-rim like effect is eliminated early and a convex structure results. For high molar masses the low dissolution rate and the low polymer diffusion might lead to increased surface tension gradients and a typical local pile-up of polymer is found. For intermediate polymer masses around 200 kDa, the dissolution and evaporation rate are comparable and the typical concave microtopology is found. This interpretation was supported by a quantitative estimation of the diffusion coefficient and the evaporation rate. For a different polymer/solvent system, polyethylmethacrylate (PEMA)/ethylacetate (EA), exclusively concave structures were found. Following the statements above this can be interpreted with a lower dissolution rate. At low molar masses the concentration of PEMA in EA most likely never reaches the gelation point. Thus, a concave instead of a convex structure occurs. At the end of this section, the optically properties of such microstructures for a potential application as microlenses are studied with laser scanning confocal microscopy. In the third part, the droplet was confined into a glass microcapillary to avoid evaporation. Since here, due to an increased area to volume ratio, the surface properties of the liquid and the solid walls became important, the influence of the surface hydrophilicity of the wall on the interfacial tension between two immiscible liquid slugs was investigated. For this a novel method for measuring the interfacial tension between the two liquids within the capillary was developed. This technique was demonstrated by measuring the interfacial tensions between slugs of pure water and standard solvents. For toluene, n-hexane and chloroform 36.2, 50.9 and 34.2 mN/m were measured at 20°C, which is in a good agreement with data from the literature. For a slug of hexane in contact with a slug of pure water containing ethanol in a concentration range between 0 and 70 (v/v %), a difference of up to 6 mN/m was found, when compared to commercial ring tensiometry. This discrepancy is still under debate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Die Analyse tandem-repetitiver DNA-Sequenzen hat einen festen Platz als genetisches Typisierungsverfahren in den Breichen der stammesgeschichtlichen Untersuchung, der Verwandtschaftsanalyse und vor allem in der forensischen Spurenkunde, bei der es durch den Einsatz der Multiplex-PCR-Analyse von Short Tandem Repeat-Systemen (STR) zu einem Durchbruch bei der Aufklärung und sicheren Zuordnung von biologischen Tatortspuren kam. Bei der Sequenzierung des humanen Genoms liegt ein besonderes Augenmerk auf den genetisch polymorphen Sequenzvariationen im Genom, den SNPs (single nucleotide polymorphisms). Zwei ihrer Eigenschaften – das häufige Vorkommen innerhalb des humanen Genoms und ihre vergleichbar geringe Mutationsrate – machen sie zu besonders gut geeigneten Werkzeugen sowohl für die Forensik als auch für die Populationsgenetik.rnZum Ziel des EU-Projekts „SNPforID“, aus welchem die vorliegende Arbeit entstanden ist, wurde die Etablierung neuer Methoden zur validen Typisierung von SNPs in Multiplexverfahren erklärt. Die Berücksichtigung der Sensitivität bei der Untersuchung von Spuren sowie die statistische Aussagekraft in der forensischen Analyse standen dabei im Vordergrund. Hierfür wurden 52 autosomale SNPs ausgewählt und auf ihre maximale Individualisierungsstärke hin untersucht. Die Untersuchungen der ersten 23 selektierten Marker stellen den ersten Teil der vorliegenden Arbeit dar. Sie umfassen die Etablierung des Multiplexverfahrens und der SNaPshot™-Typisierungsmethode sowie ihre statistische Auswertung. Die Ergebnisse dieser Untersuchung sind ein Teil der darauf folgenden, in enger Zusammenarbeit der Partnerlaboratorien durchgeführten Studie der 52-SNP-Multiplexmethode. rnEbenfalls im Rahmen des Projekts und als Hauptziel der Dissertation erfolgten Etablierung und Evaluierung des auf der Microarray-Technologie basierenden Verfahrens der Einzelbasenverlängerung auf Glasobjektträgern. Ausgehend von einer begrenzten DNA-Menge wurde hierbei die Möglichkeit der simultanen Hybridisierung einer möglichst hohen Anzahl von SNP-Systemen untersucht. Die Auswahl der hierbei eingesetzten SNP-Marker erfolgte auf der Basis der Vorarbeiten, die für die Etablierung des 52-SNP-Multiplexes erfolgreich durchgeführt worden waren. rnAus einer Vielzahl von Methoden zur Genotypisierung von biallelischen Markern hebt sich das Assay in seiner Parallelität und der Einfachheit des experimentellen Ansatzes durch eine erhebliche Zeit- und Kostenersparnis ab. In der vorliegenden Arbeit wurde das „array of arrays“-Prinzip eingesetzt, um zur gleichen Zeit unter einheitlichen Versuchsbedingungen zwölf DNA-Proben auf einem Glasobjektträger zu typisieren. Auf der Basis von insgesamt 1419 typisierten Allelen von 33 Markern konnte die Validierung mit einem Typisierungserfolg von 86,75% abgeschlossen werden. Dabei wurden zusätzlich eine Reihe von Randbedingungen in Bezug auf das Sonden- und Primerdesign, die Hybridisierungsbedingungen sowie physikalische Parameter der laserinduzierten Fluoreszenzmessung der Signale ausgetestet und optimiert. rn

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bacteria are generally difficult specimens to prepare for conventional resin section electron microscopy and mycobacteria, with their thick and complex cell envelope layers being especially prone to artefacts. Here we made a systematic comparison of different methods for preparing Mycobacterium smegmatis for thin section electron microscopy analysis. These methods were: (1) conventional preparation by fixatives and epoxy resins at ambient temperature. (2) Tokuyasu cryo-section of chemically fixed bacteria. (3) rapid freezing followed by freeze substitution and embedding in epoxy resin at room temperature or (4) combined with Lowicryl HM20 embedding and ultraviolet (UV) polymerization at low temperature and (5) CEMOVIS, or cryo electron microscopy of vitreous sections. The best preservation of bacteria was obtained with the cryo electron microscopy of vitreous sections method, as expected, especially with respect to the preservation of the cell envelope and lipid bodies. By comparison with cryo electron microscopy of vitreous sections both the conventional and Tokuyasu methods produced different, undesirable artefacts. The two different types of freeze-substitution protocols showed variable preservation of the cell envelope but gave acceptable preservation of the cytoplasm, but not lipid bodies, and bacterial DNA. In conclusion although cryo electron microscopy of vitreous sections must be considered the 'gold standard' among sectioning methods for electron microscopy, because it avoids solvents and stains, the use of optimally prepared freeze substitution also offers some advantages for ultrastructural analysis of bacteria.