967 resultados para quality use of medicines


Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE Different international target volume delineation guidelines exist and different treatment techniques are available for salvage radiation therapy (RT) for recurrent prostate cancer, but less is known regarding their respective applicability in clinical practice. METHODS AND MATERIALS A randomized phase III trial testing 64 Gy vs 70 Gy salvage RT was accompanied by an intense quality assurance program including a site-specific and study-specific questionnaire and a dummy run (DR). Target volume delineation was performed according to the European Organisation for the Research and Treatment of Cancer guidelines, and a DR-based treatment plan was established for 70 Gy. Major and minor protocol deviations were noted, interobserver agreement of delineated target contours was assessed, and dose-volume histogram (DVH) parameters of different treatment techniques were compared. RESULTS Thirty European centers participated, 43% of which were using 3-dimensional conformal RT (3D-CRT), with the remaining centers using intensity modulated RT (IMRT) or volumetric modulated arc technique (VMAT). The first submitted version of the DR contained major deviations in 21 of 30 (70%) centers, mostly caused by inappropriately defined or lack of prostate bed (PB). All but 5 centers completed the DR successfully with their second submitted version. The interobserver agreement of the PB was moderate and was improved by the DR review, as indicated by an increased κ value (0.59 vs 0.55), mean sensitivity (0.64 vs 0.58), volume of total agreement (3.9 vs 3.3 cm(3)), and decrease in the union volume (79.3 vs 84.2 cm(3)). Rectal and bladder wall DVH parameters of IMRT and VMAT vs 3D-CRT plans were not significantly different. CONCLUSIONS The interobserver agreement of PB delineation was moderate but was improved by the DR. Major deviations could be identified for the majority of centers. The DR has improved the acquaintance of the participating centers with the trial protocol.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES To assess the use of quality assessment tools among a cross-section of systematic reviews (SRs) and to further evaluate whether quality was used as a parameter in the decision to include primary studies within subsequent meta-analysis. STUDY DESIGN AND SETTING We searched PubMed for SRs (interventional, observational, and diagnostic) published in Core Clinical Journals between January 1 and March 31, 2014. RESULTS Three hundred nine SRs were identified. Quality assessment was undertaken in 222 (71.8%) with isolated use of the Cochrane risk of bias tool (26.1%, n = 58) and the Newcastle-Ottawa Scale (15.3%, n = 34) most common. A threshold level of primary study quality for subsequent meta-analysis was used in 12.9% (40 of 309) of reviews. Overall, fifty-four combinations of quality assessment tools were identified with a similar preponderance of tools used among observational and interventional reviews. Multiple tools were used in 11.7% (n = 36) of SRs overall. CONCLUSION We found that quality assessment tools were used in a majority of SRs; however, a threshold level of quality for meta-analysis was stipulated in just 12.9% (n = 40). This cross-sectional analysis provides further evidence of the need for more active or intuitive editorial processes to enhance the reporting of SRs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Web surveys are becoming increasingly popular in survey research including stated preference surveys. Compared with face-to-face, telephone and mail surveys, web surveys may contain a different and new source of measurement error and bias: the type of device that respondents use to answer the survey questions. This is the first study that tests whether the use of mobile devices, tablets or smartphones, affects survey characteristics and stated preferences in a web-based choice experiment. The web survey on expanding renewable energy production in Germany was carried out with 3182 respondents, of which 12% used a mobile device. Propensity score matching is used to account for selection bias in the use of mobile devices for survey completion. We find that mobile device users spent more time than desktop/laptop users to answer the survey. Yet, desktop/laptop users and mobile device users do not differ in acquiescence tendency as an indicator of extreme response patterns. For mobile device users only, we find a negative correlation between screen size and interview length and a positive correlation between screen size and acquiescence tendency. In the choice experiment data, we do not find significant differences in the tendency to choose the status quo option and scale between both subsamples. However, some of the estimates of implicit prices differ, albeit not in a unidirectional fashion. Model results for mobile device users indicate a U-shaped relationship between error variance and screen size. Together, the results suggest that using mobile devices is not detrimental to survey quality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objectives of this dissertation were to determine the quality of life in women with ovarian cancer and the association of their physical and emotional well-being with the number of symptoms, duration of symptoms, and the scores of common symptoms of ovarian cancer; to study the prevalence of complementary and alternative medicine techniques for symptom relief and its association with the number of symptoms, age, education, insurance, comorbidity, and satisfaction with medical care they received, and their pre-diagnostic experience of symptoms.^ This study was based on a secondary data analysis of a study of early detection of ovarian cancer. A sample of 139 women with ovarian cancer was recruited and was administered a questionnaire comprised of questions on their quality of life, their symptoms and what they did about the symptoms, whether they used any complementary and alternative medicine techniques, and other medical conditions they had. Out of this sample, 53 patients underwent in-depth interviews relating to their symptoms before the diagnosis and their experiences with the health care system leading to the ovarian cancer diagnosis. ^ In article #1, ovarian cancer patients were observed to have significantly poorer quality of life on all subscales and summary scores except pain, compared to that of the general population of US women. Physical well-being scores were negatively associated with the number of symptoms before diagnosis and a significant negative association of comorbidity index was observed with physical well-being. Higher education and increase in time since diagnosis was found to have better physical scores. Emotional well-being scores showed marginally significant associations with number of symptoms and bloating. ^ In article #2, a thematic content analysis of the ovarian cancer patients’ interviews revealed that on recognition of their symptoms women first assumed their symptoms to be a normal transient occurrence due to a pre-existing disease condition, or due to some other disease. A series of misattributions of their symptoms on their and their doctors’ part impacted their health care seeking.In article #3, a significantly greater likelihood of CAM use with an increase in the number of symptoms was observed.^ Based on the foregoing results, it is important to educate women on possible signs of ovarian cancer and also to educate doctors about the results of current research regarding ovarian cancer diagnosis. This will help to avoid a delay in getting a diagnosis and improve women’s quality of life. It emphasizes the diagnosis of ovarian cancer in earlier stages by more sensitive screening techniques. This study emphasizes the importance of consideration of comorbidity in any quality of life research. Additionally, educating women in the safe use of CAM techniques carries immense significance because the efficacy and safety of many of the currently advertized CAM products has not been scientifically validated. Further research is needed to confirm the findings of this study. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Radiological Physics Center (RPC) uses both on-site and remote reviews to credential institutions for participation in clinical trials. Anthropomorphic quality assurance (QA) phantoms are one tool the RPC uses to remotely audit institutions, which include thermoluminescent dosimeters (TLDs) and radiochromic film. The RPC desires to switch from TLD as the absolute dosimeter in the phantoms, to optically stimulated luminescent dosimeters (OSLDs), but a problem lies in the angular dependence exhibited by the OSLD. The purpose of this study was to characterize the angular dependence of OSLD and establish a correction factor if necessary, to provide accurate dosimetric measurements as a replacement for TLD in the QA phantoms. A 10 cm diameter high-impact polystyrene spherical phantom was designed and constructed to hold an OSLD to study the angular response of the dosimeter under the simplest of circumstances for both coplanar and non-coplanar treatment deliveries. OSLD were irradiated in the spherical phantom, and the responses of the dosimeter from edge-on angles were normalized to the response when irradiated with the beam incident normally on the surface of the dosimeter. The average normalized response was used to establish an angular correction factor for 6 MV and 18 coplanar treatments, and for 6 MV non-coplanar treatments specific to CyberKnife. The RPC pelvic phantom dosimetry insert was modified to hold OSLD, in addition to the TLD, adjacent to the planes of film. Treatment plans of increasing angular beam delivery were developed, three in Pinnacle v9.0 (4-field box, IMRT, and VMAT) and one in Accuray’s MultiPlan v3.5.3 (CyberKnife). The plans were delivered to the pelvic phantom containing both TLD and OSLD in the target volume. The pelvic phantom was also sent to two institutions to be irradiated as trials, one delivering IMRT, and the other a CyberKnife treatment. For the IMRT deliveries and the two institution trials, the phantom also included film in the sagittal and coronal planes. The doses measured from the TLD and OSLD were calculated for each irradiation, and the angular correction factors established from the spherical phantom irradiations were applied to the OSLD dose. The ratio of the TLD dose to the angular corrected OSLD dose was calculated for each irradiation. The corrected OSLD dose was found to be within 1% of the TLD measured dose for all irradiations, with the exception of the in-house CyberKnife deliveries. The films were normalized to both TLD measured dose and the corrected OSLD dose. Dose profiles were obtained and gamma analysis was performed using a 7%/4 mm criteria, to compare the ability of the OSLD, when corrected for the angular dependence, to provide equivalent results to TLD. The results of this study indicate that the OSLD can effectively be used as a replacement for TLD in the RPC’s anthropomorphic QA phantoms for coplanar treatment deliveries when a correction is applied for the dosimeter’s angular dependence.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cover tite: The use of existing and modified land use instruments to achieve environmental quality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

With this is bound the author's Medical reports of the effects of arsenic, in the cure of agues, remitting fevers, and periodic headachs. London, MDCCLXXVI.