994 resultados para quadrat-variance methods


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the microbial distribution in the root canal system after periapical lesion induction in dogs' teeth using different methods. Fifty-two root canals were assigned to 4 groups (n=13). Groups I and II: root canals were exposed to the oral cavity for 180 days; groups III and IV: root canals were exposed for 7 days and then the coronal openings were sealed for 53 days. The root apices of groups I and III were perforated, while those of groups II and IV remained intact. After the experimental periods, the animals were euthanized and the anatomic pieces containing the roots were processed and stained with the Brown & Brenn method to assess the presence and distribution of microorganisms. The incidence of microorganisms at different sites of the roots and periapical lesions was analyzed statistically by the chi-square test at 5% significance level. All groups presented microorganisms in the entire root canal system. A larger number of microorganisms was observed on the root canal walls, apical delta and dentinal tubules (p<0.05), followed by cementum and cemental resorption areas. In spite of the different periods of exposure to the oral environment, the methods used for induction of periapical periodontitis yielded similar distribution of microorganisms in the root canal system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the most important properties of artificial teeth is the abrasion wear resistance, which is determinant in the maintenance of the rehabilitation's occlusal pattern. OBJECTIVES: This in vitro study aims to evaluate the abrasion wear resistance of 7 brands of artificial teeth opposed to two types of antagonists. MATERIAL AND METHODS: Seven groups were prepared with 12 specimens each (BIOLUX & BL, TRILUX & TR, BLUE DENT & BD, BIOCLER & BC, POSTARIS & PO, ORTHOSIT & OR, GNATHOSTAR & GN), opposed to metallic (M & nickel-chromium alloy), and to composite antagonists (C & Solidex indirect composite). A mechanical loading device was used (240 cycles/min, 4 Hz speed, 10 mm antagonist course). Initial and final contours of each specimen were registered with aid of a profile projector (20x magnification). The linear difference between the two profiles was measured and the registered values were subjected to ANOVA and Tukey's test. RESULTS: Regarding the antagonists, only OR (M = 10.45 ± 1.42 µm and C = 2.77 ± 0.69 µm) and BC (M = 6.70 ± 1.37 µm and C = 4.48 ± 0.80 µm) presented statistically significant differences (p < 0.05). Best results were obtained with PO (C = 2.33 ± 0.91 µm and M = 1.78 ± 0.42 µm), followed by BL (C = 3.70 ± 1.32 µm and M = 3.70 ± 0.61 µm), statistically similar for both antagonists (p>0.05). Greater result variance was obtained with OR, which presented the worse results opposed to Ni-Cr (10.45 ± 1.42 µm), and results similar to the best ones against composite (2.77 ± 0.69 µm). CONCLUSIONS: Within the limitations of this study, it may be concluded that the antagonist material is a factor of major importance to be considered in the choice of the artificial teeth to be used in the prosthesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The interest in using titanium to fabricate removable partial denture (RPD) frameworks has increased, but there are few studies evaluating the effects of casting methods on clasp behavior. OBJECTIVE: This study compared the occurrence of porosities and the retentive force of commercially pure titanium (CP Ti) and cobalt-chromium (Co-Cr) removable partial denture circumferential clasps cast by induction/centrifugation and plasma/vacuum-pressure. MATERIAL AND METHODS: 72 frameworks were cast from CP Ti (n=36) and Co-Cr alloy (n=36; control group). For each material, 18 frameworks were casted by electromagnetic induction and injected by centrifugation, whereas the other 18 were casted by plasma and injected by vacuum-pressure. For each casting method, three subgroups (n=6) were formed: 0.25 mm, 0.50 mm, and 0.75 mm undercuts. The specimens were radiographed and subjected to an insertion/removal test simulating 5 years of framework use. Data were analyzed by ANOVA and Tukey's to compare materials and cast methods (α=0.05). RESULTS: Three of 18 specimens of the induction/centrifugation group and 9 of 18 specimens of plasma/vacuum-pressure cast presented porosities, but only 1 and 7 specimens, respectively, were rejected for simulation test. For Co-Cr alloy, no defects were found. Comparing the casting methods, statistically significant differences (p<0.05) were observed only for the Co-Cr alloy with 0.25 mm and 0.50 mm undercuts. Significant differences were found for the 0.25 mm and 0.75 mm undercuts dependent on the material used. For the 0.50 mm undercut, significant differences were found when the materials were induction casted. CONCLUSION: Although both casting methods produced satisfactory CP Ti RPD frameworks, the occurrence of porosities was greater in the plasma/vacuum-pressure than in the induction/centrifugation method, the latter resulting in higher clasp rigidity, generating higher retention force values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated in vitro the capacity of debris removal from the apical third of flattened root canals, using different final irrigation protocols. Thirty human mandibular central incisors with a mesiodistal flattened root were prepared using rotary instrumentation by Endo-Flare 25.12 and Hero 642 30.06, 35.02, 40.02 files, irrigated with 2 mL of 1% NaOCl after each file. The specimens were randomly distributed into 5 groups according to the final irrigation of root canals: Group I: 10 mL of distilled water (control), Group II: 10 mL of 1% NaOCl for 8 min, Group III: 2 mL of 1% NaOCl for 2 min (repeated 4 times), Group IV: 10 mL of 2.5% NaOCl for 8 min, and Group V: 10 mL of 2.5% NaOCl for 2 min (repeated 4 times). The apical thirds of the specimens were subjected to histological processing and 6-μm cross-sections were obtained and stained with hematoxylin-eosin. The specimens were examined under optical microscopy at ×40 magnification and the images were subjected to morphometric analysis using the Scion image-analysis software. The total area of root canal and the area with debris were measured in square millimeters. Analysis of variance showed no statistically significant difference (p>0.05) among the groups GI (2.39 ± 3.59), GII (2.91 ± 2.21), GIII (0.73 ± 1.36), GIV (0.95 ± 0.84) and GV (0.51 ± 0.22). In conclusion, the final irrigation protocols evaluated in this study using the Luer syringe presented similar performance in the removal of debris from the apical third of flattened root canals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compared the mandibular displacement from three methods of centric relation record using an anterior jig associated with (A) chin point guidance, (B) swallowing (control group) and (C) bimanual manipulation. Ten patients aged 25-39 years were selected if they met the following inclusion criteria: complete dentition (up to the second molars), Angle class I and absence of signs and symptoms of temporomandibular disorders and diagnostic casts showing stability in the maximum intercuspation (MI) position. Impressions of maxillary and mandibular arches were made with an irreversible hydrocolloid impression material. Master casts of each patient were obtained, mounted on a microscope table in MI as a reference position and 5 records of each method were made per patient. The mandibular casts were then repositioned with records interposed and new measurements were obtained. The difference between the two readings allowed measuring the displacement of the mandible in the anteroposterior and lateral axes. Data were analyzed statistically by ANOVA and Tukey's test at 5% significance level. There was no statistically significant differences (p>0.05) among the three methods for measuring lateral displacement (A=0.38 ± 0.26, B=0.32 ± 0.25 and C=0.32 ± 0.23). For the anteroposterior displacement (A=2.76 ± 1.43, B=2.46 ± 1.48 and C=2.97 ± 1.51), the swallowing method (B) differed significantly from the others (p<0.05), but no significant difference (p>0.05) was found between chin point guidance (A) and bimanual manipulation (C). In conclusion, the swallowing method produced smaller mandibular posterior displacement than the other methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Secondary caries has been reported as the main reason for restoration replacement. The aim of this in vitro study was to evaluate the performance of different methods - visual inspection, laser fluorescence (DIAGNOdent), radiography and tactile examination - for secondary caries detection in primary molars restored with amalgam. Fifty-four primary molars were photographed and 73 suspect sites adjacent to amalgam restorations were selected. Two examiners evaluated independently these sites using all methods. Agreement between examiners was assessed by the Kappa test. To validate the methods, a caries-detector dye was used after restoration removal. The best cut-off points for the sample were found by a Receiver Operator Characteristic (ROC) analysis, and the area under the ROC curve (Az), and the sensitivity, specificity and accuracy of the methods were calculated for enamel (D2) and dentine (D3) thresholds. These parameters were found for each method and then compared by the McNemar test. The tactile examination and visual inspection presented the highest inter-examiner agreement for the D2 and D3 thresholds, respectively. The visual inspection also showed better performance than the other methods for both thresholds (Az = 0.861 and Az = 0.841, respectively). In conclusion, the visual inspection presented the best performance for detecting enamel and dentin secondary caries in primary teeth restored with amalgam.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the effect of the use of 0.5% and 2% chlorhexidine digluconate on the immediate bond strength of a conventional adhesive system to dentin in primary teeth. METHODS: Twenty-one healthy primary molars were divided into three groups (n=7), being one control (A) and two experimental groups (B and C). After dentin exposure, in Group (A) the adhesive procedure was performed using 37% phosphoric acid gel (15 s); dentin was washed (15 s), air dried (30 s) and rehydrated with water. Groups B and C followed similar procedures but for re-hydration with 0.5% and 2% chlorhexidine, respectively, for 30 s. A resin composite block was built simulating a restoration, and the teeth were stored in distilled water at 37°C for 24 h before the microtensile bond strength test. The bond strength data were analyzed by analysis of variance. RESULTS: No statistically significant difference in bond strength was found among the tested groups (P>0.05) CONCLUSION: The 0.5% and 2% concentrations of chlorhexidine presented similar behavior and caused no adverse effects on the bond strength to dentin in primary teeth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: This in situ study evaluated the discriminatory power and reliability of methods of dental plaque quantification and the relationship between visual indices (VI) and fluorescence camera (FC) to detect plaque. MATERIAL AND METHODS: Six volunteers used palatal appliances with six bovine enamel blocks presenting different stages of plaque accumulation. The presence of plaque with and without disclosing was assessed using VI. Images were obtained with FC and digital camera in both conditions. The area covered by plaque was assessed. Examinations were done by two independent examiners. Data were analyzed by Kruskal-Wallis and Kappa tests to compare different conditions of samples and to assess the inter-examiner reproducibility. RESULTS: Some methods presented adequate reproducibility. The Turesky index and the assessment of area covered by disclosed plaque in the FC images presented the highest discriminatory powers. CONCLUSION: The Turesky index and images with FC with disclosing present good reliability and discriminatory power in quantifying dental plaque.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gaseous N losses from soil are considerable, resulting mostly from ammonia volatilization linked to agricultural activities such as pasture fertilization. The use of simple and accessible measurement methods of such losses is fundamental in the evaluation of the N cycle in agricultural systems. The purpose of this study was to evaluate quantification methods of NH3 volatilization from fertilized surface soil with urea, with minimal influence on the volatilization processes. The greenhouse experiment was arranged in a completely randomized design with 13 treatments and five replications, with the following treatments: (1) Polyurethane foam (density 20 kg m-3) with phosphoric acid solution absorber (foam absorber), installed 1, 5, 10 and 20 cm above the soil surface; (2) Paper filter with sulfuric acid solution absorber (paper absorber, 1, 5, 10 and 20 cm above the soil surface); (3) Sulfuric acid solution absorber (1, 5 and 10 cm above the soil surface); (4) Semi-open static collector; (5) 15N balance (control). The foam absorber placed 1 cm above the soil surface estimated the real daily rate of loss and accumulated loss of NH3N and proved efficient in capturing NH3 volatized from urea-treated soil. The estimates based on acid absorbers 1, 5 and 10 cm above the soil surface and paper absorbers 1 and 5 cm above the soil surface were only realistic for accumulated N-NH3 losses. Foam absorbers can be indicated to quantify accumulated and daily rates of NH3 volatilization losses similarly to an open static chamber, making calibration equations or correction factors unnecessary.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: avaliar o efeito da administração da associação estavudina/nelfinavir durante toda a prenhez da rata, avaliando seu peso e dos conceptos, bem como o número de implantações, fetos, placentas, reabsorções e mortalidades materna e fetal. MÉTODOS: quarenta ratas albinas EPM-1 Wistar, prenhes, foram aleatoriamente divididas em quatro grupos: GCtrl (controle do veículo) e três experimentais, ExpI, ExpII e ExpIII, que receberam, respectivamente, 1/40, 3/120 e 9/360 mg/kg por dia de estavudina/nelfinavir por via oral. As drogas e o veículo (água destilada) foram administrados por gavagem em duas tomadas diárias (12/12 horas), desde o dia 0 até o 20º dia da prenhez. No último dia do experimento, todos os animais foram anestesiados e eutanasiados. Foram avaliados a evolução do peso materno no 7º, 14º e 20º dias, número de fetos, placentas, implantações, reabsorções, óbitos intrauterinos, malformações maiores e o peso dos fetos e das placentas. A análise estatística foi realizada por análise de variância (ANOVA), complementada pelo teste de Kruskal-Wallis (p<0,05). RESULTADOS: em relação ao peso corporal das ratas, houve ganho gradual e progressivo durante o decorrer da prenhez em todos os grupos, sendo este ganho mais evidente no período final; porém não foram constatadas diferenças estatisticamente significantes entre eles. O número de fetos, placentas, implantações, assim como os pesos fetais e placentários também não mostraram diferenças estatisticamente significantes entre os grupos analisados. Não foram observadas, também nos grupos experimentais, reabsorções e malformações fetais maiores externas, no entanto, observamos entre o 8º e o 14º dias de gestação um caso de morte materna em cada grupo experimental. CONCLUSÕES: a administração da associação estavudina/nelfinavir não mostrou efeitos deletérios sobre os conceptos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: avaliar os efeitos da administração da associação zidovudina-lamivudina-ritonavir nos fígados e rins de ratas prenhes e seus conceptos do ponto de vista morfológico e fisiológico. MÉTODOS: 40 ratas albinas prenhes foram aleatoriamente divididas em 4 grupos: 1 controle (Ctrl: controle de veículo) e 3 experimentais (Exp1x, Exp3x e Exp9x). Estes últimos foram tratados por solução oral de zidovudina/lamivudina/ritonavir (Exp1x: 10/5/20 mg/kg; Exp3x: 30/15/60 mg/kg; Exp9x: 90/45/180 mg/kg). As drogas e o veículo foram administrados por gavagem, desde o 1º até o 20º dia de prenhez. No último dia do experimento, todos os animais foram anestesiados e sangue foi retirado da cavidade cardíaca para avaliação sérica das enzimas aspartato aminotransferase (AST) e alanina aminotransferase (ALT), por método calorimétrico, bem como da ureia, determinada por método cinético-enzimático, e creatinina, por método cinético-colorimétrico. Em seguida, fragmentos dos fígados e rins maternos e fetais foram coletados, fixados em formol a 10% e processados segundo os métodos histológicos para inclusão em parafina. Cortes com 5 µm de espessura foram corados pela hematoxilina-eosina (HE) e analisados por microscopia de luz. Na leitura das lâminas, considerou-se o padrão de normalidade para fígado e rins, tais como: hepatócitos, espaço porta íntegros e veias hepáticas bem definidas. Nos rins, a presença de corpúsculos renais, túbulos contorcidos e alças de Henle típicos. Nos fígados fetais considerou-se, ainda, a morfologia das células da linhagem eritrocitária nas diferentes fases do desenvolvimento, bem como os megacariócitos. Quando houve alteração da coloração padrão estabelecida para as estruturas hepáticas e renais, alteração na morfologia de núcleos, rompimento de limites de alguma organela citoplasmática, presença de congestão vascular, tudo isso foi entendido como provavelmente provocado pelas drogas em sua(s) dose(s) de aplicação. A avaliação estatística foi realizada por análise de variância (ANOVA), completada pelo teste de Tukey-Kramer (p<0,05). RESULTADOS: os fígados maternos dos grupos Ctrl, Exp1x e Exp3x mostraram hepatócitos típicos, espaço porta íntegros e veias hepáticas com aspecto normal. No fígado materno do grupo Exp9x, foram encontrados hepatócitos com sinais de atrofia e apoptose (eosinofilia citoplasmática e núcleos picnóticos). Além disso, identificou-se vasodilatação dos capilares sinusoides (congestão). Os rins maternos dos grupos Ctrl e Exp1x apresentaram-se normais, com corpúsculos renais, túbulos contorcidos e alças de Henle típicos. Já nos grupos Exp3x e Exp9x, foram encontrados congestão vascular, glomérulos pequenos ricos em células contendo núcleos hipercromáticos, sendo mais intensos no Exp9x. Com relação aos fígados e rins fetais, não foram observadas alterações morfológicas ou fisiológicas nos grupos estudados. Encontrou-se aumento significante nos níveis da AST (305,70±55,80; p<0,05) e da creatinina (0,50±0,09; p<0,05) no grupo Exp9x. CONCLUSÕES: nossos resultados evidenciam que a administração da associação zidovudina/lamivudina/ritonavir a ratas prenhes em altas doses causa alterações morfológicas e funcionais nos fígados e rins maternos. Não houve alterações nem morfológicas nem fisiológicas nos fígados e rins fetais.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Technical evaluation of analytical data is of extreme relevance considering it can be used for comparisons with environmental quality standards and decision-making as related to the management of disposal of dredged sediments and the evaluation of salt and brackish water quality in accordance with CONAMA 357/05 Resolution. It is, therefore, essential that the project manager discusses the environmental agency's technical requirements with the laboratory contracted for the follow-up of the analysis underway and even with a view to possible re-analysis when anomalous data are identified. The main technical requirements are: (1) method quantitation limits (QLs) should fall below environmental standards; (2) analyses should be carried out in laboratories whose analytical scope is accredited by the National Institute of Metrology (INMETRO) or qualified or accepted by a licensing agency; (3) chain of custody should be provided in order to ensure sample traceability; (4) control charts should be provided to prove method performance; (5) certified reference material analysis or, if that is not available, matrix spike analysis, should be undertaken and (6) chromatograms should be included in the analytical report. Within this context and with a view to helping environmental managers in analytical report evaluation, this work has as objectives the discussion of the limitations of the application of SW 846 US EPA methods to marine samples, the consequences of having data based on method detection limits (MDL) and not sample quantitation limits (SQL), and present possible modifications of the principal method applied by laboratories in order to comply with environmental quality standards.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The naturally occurring clonal diversity among field isolates of the major human malaria parasite Plasmodium vivax remained unexplored until the early 1990s, when improved molecular methods allowed the use of blood samples obtained directly from patients, without prior in vitro culture, for genotyping purposes. Here we briefly review the molecular strategies currently used to detect genetically distinct clones in patient-derived P. vivax samples, present evidence that multiple-clone P. vivax infections are commonly detected in areas with different levels of malaria transmission and discuss possible evolutionary and epidemiological consequences of the competition between genetically distinct clones in natural human infections. We suggest that, when two or more genetically distinct clones are present in the same host, intra-host competition for limited resources may select for P. vivax traits that represent major public health challenges, such as increased virulence, increased transmissibility and antimalarial drug resistance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a validade e a confiabilidade da versão brasileira de índice de capacidade para o trabalho. MÉTODOS:Estudo transversal com amostra de 475 trabalhadores de empresa do setor elétrico no estado de São Paulo (dez municípios em Campinas e região), realizado em 2005. Foram avaliados os seguintes aspectos da versão brasileira do Índice de Capacidade para o Trabalho: validade de construto, por meio de análise fatorial confirmatória e da capacidade discriminante; validade de critério, correlacionado o escore do índice com medidas de saúde auto-referidas; e confiabilidade, por meio da análise da consistência interna utilizando o coeficiente alfa de Cronbach. RESULTADOS: A análise fatorial indicou três fatores do construto capacidade para o trabalho: questões relativas aos "recursos mentais" (20,6% da variância), à autopercepção da capacidade para o trabalho (18,9% da variância) e à presença de doenças e limitações decorrentes do estado de saúde (18,4% da variância). O índice discriminou os trabalhadores segundo nível de absenteísmo, identificando média estatisticamente significativa (p<0,001) entre aqueles com absenteísmo elevado (37,2 pontos) e baixo (42,3 pontos). A análise de critério mostrou correlação do índice com todas as dimensões do estado de saúde analisadas (p<0,0001). O índice apresentou boa confiabilidade com coeficiente alfa de Cronbach (0,72). CONCLUSÕES: A versão brasileira do Índice de Capacidade para o Trabalho mostrou propriedades psicométricas satisfatórias quanto à validade de construto, de critério e de confiabilidade, representando uma opção adequada para avaliação da capacidade para o trabalho em abordagens individuais e inquéritos populacionais.