984 resultados para pressure measurements
Resumo:
The impact of plasma technologies is growing both in the academic and in the industrial fields. Nowadays, a great interest is focused in plasma applications in aeronautics and astronautics domains. Plasma actuators based on the Magneto-Hydro-Dynamic (MHD) and Electro- Hydro-Dynamic (EHD) interactions are potentially able to suitably modify the fluid-dynamics characteristics around a flying body without utilizing moving parts. This could lead to the control of an aircraft with negligible response time, more reliability and improvements of the performance. In order to study the aforementioned interactions, a series of experiments and a wide number of diagnostic techniques have been utilized. The EHD interaction, realized by means of a Dielectric Barrier Discharge (DBD) actuator, and its impact on the boundary layer have been evaluated by means of two different experiments. In the first one a three phase multi-electrode flat panel actuator is used. Different external flow velocities (from 1 to 20m/s) and different values of the supplied voltage and frequency have been considered. Moreover a change of the phase sequence has been done to verify the influence of the electric field existing between successive phases. Measurements of the induced speed had shown the effect of the supply voltage and the frequency, and the phase order in the momentum transfer phenomenon. Gains in velocity, inside the boundary layer, of about 5m/s have been obtained. Spectroscopic measurements allowed to determine the rotational and the vibrational temperature of the plasma which lie in the range of 320 ÷ 440°K and of 3000 ÷ 3900°K respectively. A deviation from thermodynamic equilibrium had been found. The second EHD experiment is realized on a single electrode pair DBD actuator driven by nano-pulses superimposed to a DC or an AC bias. This new supply system separates the plasma formation mechanism from the acceleration action on the fluid, leading to an higher degree of the control of the process. Both the voltage and the frequency of the nano-pulses and the amplitude and the waveform of the bias have been varied during the experiment. Plasma jets and vortex behavior had been observed by means of fast Schlieren imaging. This allowed a deeper understanding of the EHD interaction process. A velocity increase in the boundary layer of about 2m/s had been measured. Thrust measurements have been performed by means of a scales and compared with experimental data reported in the literature. For similar voltage amplitudes thrust larger than those of the literature, had been observed. Surface charge measurements led to realize a modified DBD actuator able to obtain similar performances when compared with that of other experiments. However in this case a DC bias replacing the AC bias had been used. MHD interaction experiments had been carried out in a hypersonic wind tunnel in argon with a flow of Mach 6. Before the MHD experiments a thermal, fluid-dynamic and plasma characterization of the hypersonic argon plasma flow have been done. The electron temperature and the electron number density had been determined by means of emission spectroscopy and microwave absorption measurements. A deviation from thermodynamic equilibrium had been observed. The electron number density showed to be frozen at the stagnation region condition in the expansion through the nozzle. MHD experiments have been performed using two axial symmetric test bodies. Similar magnetic configurations were used. Permanent magnets inserted into the test body allowed to generate inside the plasma azimuthal currents around the conical shape of the body. These Faraday currents are responsible of the MHD body force which acts against the flow. The MHD interaction process has been observed by means of fast imaging, pressure and electrical measurements. Images showed bright rings due to the Faraday currents heating and exciting the plasma particles. Pressure measurements showed increases of the pressure in the regions where the MHD interaction is large. The pressure is 10 to 15% larger than when the MHD interaction process is silent. Finally by means of electrostatic probes mounted flush on the test body lateral surface Hall fields of about 500V/m had been measured. These results have been used for the validation of a numerical MHD code.
Resumo:
Flory-Huggins interaction parameters and thermal diffusion coefficients were measured for aqueous biopolymer solutions. Dextran (a water soluble polysaccharide) and bovine serum albumin (BSA, a water soluble protein) were used for this study. The former polymer is representative for chain macromolecules and the latter is for globular macromolecules. The interaction parameters for the systems water/dextran and water/BSA were determined as a function of composition by means of vapor pressure measurements, using a combination of headspace sampling and gas chromatography (HS-GC). A new theoretical approach, accounting for chain connectivity and conformational variability, describes the observed dependencies quantitatively for the system water/dextran and qualitatively for the system water/BSA. The phase diagrams of the ternary systems water/methanol/dextran and water/dextran/BSA were determined via cloud point measurements and modeled by means of the direct minimization of the Gibbs energy using the information on the binary subsystems as input parameters. The thermal diffusion of dextran was studied for aqueous solutions in the temperature range 15 < T < 55 oC. The effects of the addition of urea were also studied. In the absence of urea, the Soret coefficient ST changes its sign as T is varied; it is positive for T > 45.0 oC, but negative for T < 45.0 oC. The positive sign of ST means that the dextran molecules migrate towards the cold side of the fluid; this behavior is typical for polymer solutions. While a negative sign indicates the macromolecules move toward the hot side; this behavior has so far not been observed with any other binary aqueous polymer solutions. The addition of urea to the aqueous solution of dextran increases ST and reduces the inversion temperature. For 2 M urea, the change in the sign of ST is observed at T = 29.7 oC. At higher temperature ST is always positive in the studied temperature range. To rationalize these observations it is assumed that the addition of urea opens hydrogen bonds, similar to that induced by an increase in temperature. For a future extension of the thermodynamic studies to the effects of poly-dispersity, dextran was fractionated by means of a recently developed technique called Continuous Spin Fractionation (CSF). The solvent/precipitant/polymer system used for the thermodynamic studies served as the basis for the fractionation of dextran The starting polymer had a weight average molar mass Mw = 11.1 kg/mol and a molecular non-uniformity U= Mw / Mn -1= 1.0. Seventy grams of dextran were fractionated using water as the solvent and methanol as the precipitant. Five fractionation steps yielded four samples with Mw values between 4.36 and 18.2 kg/mol and U values ranging from 0.28 to 0.48.
Resumo:
Diese Arbeit beschäftigt sich mit den Unterschieden zwischen linearen und verzweigten Oligomeren/Polymeren mit praktisch gleichem chemischem Bau. Untersucht wurden eine Reihe von ungeladenen Polymeren in Hinsicht auf deren Wechselwirkungsparameter mit Lö-sungsmitteln sowie peripher geladene Dendrimere im Hinblick auf deren Staudingerindices in Wasser. Bei den ungeladenen Oligomeren/Polymeren handelt es sich um Oligoisoprene, Polygly-cerine und Oligo-Dimetylsiloxane. Vor den thermodynamischen Messungen war es notwen-dig, die verzweigten Produkte durch diskontinuierliche Spinn-Fraktionierung von linearen Bestandteilen zu befreien. In diesem Zusammenhang wurden die Phasendiagramme der Aus-gangsproben und der fraktionierten Proben bestimmt und mit denen der entsprechenden linea-ren Polymeren verglichen. Die Ergebnisse zeigen deutliche Einflüsse der Molekularchitektur, wobei Mischungen aus linearen und verzweigten Polymeren plus niedermolekularen Flüssig-keiten infolge der Unverträglichkeit der hochmolekularen Komponenten ungewöhnliches Verhalten zeigen. Die Flory-Huggins Wechselwirkungsparameter von linearen und verzweigten Polyme-ren wurden mit Hilfe von Dampfdruckmessungen (Headspace-Gaschromatographie) und dampfdruckosmometrischen Messungen bei unterschiedlichen Temperaturen bestimmt. Es zeigt sich, daß die -Werte in komplexer Weise von der Konzentration abhängen und mit einem Ansatz nach Wolf (Gleichung 26 und 31) quantitativ modellierbar sind. Allgemein gilt die folgende Ungleichung: bra > lin. Die Untersuchungen bezüglich der Staudingerindeces von Polyelektrolyten wurden an vier Generationen von peripher geladenen Dendrimeren durchgeführt. Die Ergebnisse zeigen, dass die [ ] Werte mit zunehmender Generation deutlich sinken. Bei der 1. Generation ver-hält sich das Dendrimer noch sehr ähnlich wie lineare Polyelektrolyte. Mit steigender Zahl der Generationen nimmt der Staudingerindex trotz zunehmendem Molekulargewicht deutlich ab, da der Polyelektrolyteffekt (Aufweitung der Knäuel durch elektrostatische Wechselwirkung) an Bedeutung verliert. Der Grund dafür liegt in einer Zunahme des Abstands der Ladungen zur Hauptkette und der Tatsache, dass der Zahl der Ladungen pro Molekül bei konstantem n entsprechend einer quadratischen Reihe zu (2, 4, 8, 16) zunimmt. Wie aus Messungen an der ETH Zürich bekannt ist, verhalten sich ungeladene Dendrimere in organischen Lösungsmit-teln wie die Lösungen von linearem Polystyrol.
Resumo:
OBJECTIVE: To compare the proportion and rate of healing, pain, and quality of life of low-strength medical compression stockings (MCS) with traditional bandages applied for the treatment of recalcitrant venous leg ulcers. METHODS: A single-center, randomized, open-label study was performed with consecutive patients. Sigvaris prototype MCS providing 15 mm Hg-25 mm Hg at the ankle were compared with multi-layer short-stretch bandages. In both groups, pads were placed above incompetent perforating veins in the ulcer area. The initial static pressure between the dressing-covered ulcer and the pad was 29 mm Hg and 49 mm Hg with MCS and bandages, respectively. Dynamic pressure measurements showed no difference. Compression was maintained day and night and changed every week. The primary endpoint was healing within 90 days. Secondary endpoints were healing within 180 days, time to healing, pain (weekly Likert scales), and monthly quality of life (ChronIc Venous Insufficiency Quality of Life [CIVIQ] questionnaire). RESULTS: Of 74 patients screened, 60 fulfilled the selection criteria and 55 completed the study; 28 in the MCS and 27 in the bandage group. Ulcers were recurrent (48%), long lasting (mean, 27 months), and large (mean, 13 cm2). All but one patient had deep venous reflux and/or incompetent perforating veins in addition to trunk varices. Characteristics of patients and ulcers were evenly distributed (exception: more edema in the MCS group; P = .019). Healing within 90 days was observed in 36% with MCS and in 48% with bandages (P = .350). Healing within 180 days was documented in 50% with MCS and in 67% with bandages (P = .210). Time to healing was identical. Pain scored 44 and 46 initially (on a scale in which 100 referred to maximum and 0 to no pain) and decreased within the first week to 20 and 28 in the MCS and bandage groups, respectively (P < .001 vs .010). Quality of life showed no difference between the treatment groups. In both groups, pain at 90 days had decreased by half, independent of completion of healing. Physical, social, and psychic impairment improved significantly in patients with healed ulcers only. CONCLUSION: Our study illustrates the difficulty of bringing large and long-standing venous ulcers to heal. The effect of compression with MCS was not different from that of compression with bandages. Both treatments alleviated pain promptly. Quality of life was improved only in patients whose ulcers had healed.
Resumo:
Advances in the area of mobile and wireless communication for healthcare (m-Health) along with the improvements in information science allow the design and development of new patient-centric models for the provision of personalised healthcare services, increase of patient independence and improvement of patient's self-control and self-management capabilities. This paper comprises a brief overview of the m-Health applications towards the self-management of individuals with diabetes mellitus and the enhancement of their quality of life. Furthermore, the design and development of a mobile phone application for Type 1 Diabetes Mellitus (T1DM) self-management is presented. The technical evaluation of the application, which permits the management of blood glucose measurements, blood pressure measurements, insulin dosage, food/drink intake and physical activity, has shown that the use of the mobile phone technologies along with data analysis methods might improve the self-management of T1DM.
Resumo:
OBJECTIVES: This study was designed to compare coronary collateral function in patients after bare-metal stent (BMS) or drug-eluting stent (DES) implantation. BACKGROUND: Drug-eluting stents have an inhibitory effect on the production of cytokines, chemotactic proteins, and growth factors, and may therefore negatively affect coronary collateral growth. METHODS: A total of 120 patients with long-term stable coronary artery disease (CAD) after stent implantation were included. Both the BMS group and the DES group comprised 60 patients matched for in-stent stenosis severity of the vessel undergoing collateral flow index (CFI) measurement at follow-up and for the duration of follow-up. The primary end point of the investigation was invasively determined coronary collateral function 6 months after stent implantation. Collateral function was assessed by simultaneous aortic, coronary wedge, and central venous pressure measurements (yielding CFI) and by intracoronary electrocardiogram during balloon occlusion. RESULTS: There were no differences between the groups regarding age, gender, body mass index, frequency of cardiovascular risk factors, use of cardiovascular drugs, severity of CAD, or site of coronary artery stenoses. Despite equal in-stent stenosis severity (46 +/- 34% and 45 +/- 36%) and equal follow-up duration (6.2 +/- 10 months and 6.5 +/- 5.4 months), CFI was diminished in the DES versus BMS group (0.154 +/- 0.097 vs. 0.224 +/- 0.142; p = 0.0049), and the rate of collaterals insufficient to prevent ischemia during occlusion (intracoronary electrocardiographic ST-segment elevation > or =0.1 mV) was higher with 50 of 60 patients in the DES group and 33 of 60 patients in the BMS group (p = 0.001). CONCLUSIONS: Collateral function long after coronary stenting is impaired with DES (sirolimus and paclitaxel) when compared with BMS. Considering the protective nature of collateral vessels, this could lead to more serious cardiac events in the presence of an abrupt coronary occlusion.
Resumo:
OBJECTIVE: Contact of blood with artificial surfaces and air as well as ischemia/reperfusion injury to the heart and lungs mediate systemic and local inflammation during cardiopulmonary bypass (CPB). Activation of complement and coagulation cascades leads to and accompanies endothelial cell damage. Therefore, endothelial-targeted cytoprotection with the complement inhibitor and endothelial protectant dextran sulfate (DXS, MW 5000) may attenuate CBP-associated myocardial and pulmonary injury. METHODS: Eighteen pigs (DXS, n=10; phosphate buffered saline [PBS], n=8) underwent standard cardiopulmonary bypass. After aortic cross-clamping, cardiac arrest was initiated with modified Buckberg blood cardioplegia (BCP), repeated after 30 and 60 min with BCP containing either DXS (300 mg/10 ml, equivalent to 5mg/kg) or 10 ml of PBS. Following 30 min reperfusion, pigs were weaned from CPB. During 2h of observation, cardiac function was monitored by echocardiography and invasive pressure measurements. Inflammatory and coagulation markers were assessed regularly. Animals were then sacrificed and heart and lungs analyzed. RESULTS: DXS significantly reduced CK-MB levels (43.4+/-14.8 ng/ml PBS, 35.9+/-11.1 ng/ml DXS, p=0.042) and significantly diminished cytokine release: TNFalpha (1507.6+/-269.2 pg/ml PBS, 222.1+/-125.6 pg/ml DXS, p=0.0071), IL1beta (1081.8+/-203.0 pg/ml PBS, 110.7+/-79.4 pg/ml DXS, p=0.0071), IL-6 (173.0+/-91.5 pg/ml PBS, 40.8+/-19.4 pg/ml DXS, p=0.002) and IL-8 (304.6+/-81.3 pg/ml PBS, 25.4+/-14.2 pg/ml DXS, p=0.0071). Tissue endothelin-1 levels were significantly reduced (6.29+/-1.90 pg/100mg PBS, 3.55+/-1.15 pg/100mg DXS p=0.030) as well as thrombin-anti-thrombin formation (20.7+/-1.0 microg/ml PBS, 12.8+/-4.1 microg/ml DXS, p=0.043). Also DXS reduced cardiac and pulmonary complement deposition, neutrophil infiltration, hemorrhage and pulmonary edema (measured as lung water content, 81+/-3% vs 78+/-3%, p=0.047), indicative of attenuated myocardial and pulmonary CPB-injury. Diastolic left ventricular function (measured as dp/dt(min)), pulmonary artery pressure (21+/-3 mmHg PBS, 19+/-3 mmHg DXS, p=0.002) and right ventricular pressure (21+/-1 mmHg PBS, 19+/-3 mmHg DXS p=0.021) were significantly improved with the use of DXS. CONCLUSIONS: Addition of DXS to the BCP solution ameliorates post-CPB injury and to a certain extent improves cardiopulmonary function. Endothelial protection in addition to myocyte protection may improve post-CPB outcome and recovery.
Resumo:
OBJECTIVE: Treatment of central and paracentral pulmonary embolism in patients with hemodynamic compromise remains a subject of debate, and no consensus exists regarding the best method: thrombolytic agents, catheter-based thrombus aspiration or fragmentation, or surgical embolectomy. We reviewed our experience with emergency surgical pulmonary embolectomy. METHODS: Between January of 2000 and March of 2007, 25 patients (17 male, mean age 60 years) underwent emergency open embolectomy for central and paracentral pulmonary embolism. Eighteen patients presented in cardiogenic shock, 8 of whom had cardiac arrest and required cardiopulmonary resuscitation. All patients underwent operation with mild hypothermic cardiopulmonary bypass. Concomitant procedures were performed in 8 patients (3 coronary artery bypass grafts, 2 patent foramen ovale closures, 4 ligations of the left atrial appendage, 3 removals of a right atrial thrombus). Follow-up is 96% complete with a median of 2 years (range, 2 months to 6 years). RESULTS: All patients survived the procedure, but 2 patients died in the hospital on postoperative days 1 (intracerebral bleeding) and 11 (multiorgan failure), accounting for a 30-day mortality of 8% (95% confidence interval: 0.98-0.26). Four patients died later because of their underlying disease. Pre- and postoperative echocardiographic pressure measurements demonstrated the reduction of the pulmonary hypertension to half of the systemic pressure values or less. CONCLUSION: Surgical pulmonary embolectomy is an excellent option for patients with major pulmonary embolism and can be performed with minimal mortality and morbidity. Even patients who present with cardiac arrest and require preoperative cardiopulmonary resuscitation show satisfying results. Immediate surgical desobstruction favorably influences the pulmonary pressure and the recovery of right ventricular function, and remains the treatment of choice for patients with massive central and paracentral embolism with hemodynamic and respiratory compromise.
Resumo:
BACKGROUND: Regression of left ventricular (LV) hypertrophy with normalization of diastolic function has been reported in patients with aortic stenosis late after aortic valve replacement (AVR). The purpose of the present study was to evaluate the effect of AVR on LV function and structure in chronic aortic regurgitation early and late after AVR. METHODS AND RESULTS: Twenty-six patients were included in the present analysis. Eleven patients with severe aortic regurgitation were studied before, early (21 months) and late (89 months) after AVR through the use of LV biplane angiograms, high-fidelity pressure measurements, and LV endomyocardial biopsies. Fifteen healthy subjects were used as controls. LV systolic function was determined from biplane ejection fraction and midwall fractional shortening. LV diastolic function was calculated from the time constant of LV relaxation, peak filling rates, and myocardial stiffness constant. LV structure was assessed from muscle fiber diameter, interstitial fibrosis, and fibrous content. LV muscle mass decreased significantly by 38% early and 55% late after surgery. Ejection fraction was significantly reduced preoperatively and did not change after AVR (P=NS). LV relaxation was significantly prolonged before surgery (89+/-28 ms) but was normalized late after AVR (42+/-14 ms). Early and late peak filling rates were increased preoperatively but normalized postoperatively. Diastolic stiffness constant was increased before surgery (22+/-6 versus 9+/-3 in control subjects; P=0.0003) and remained elevated early and late after AVR (23+/-4; P=0.002). Muscle fiber diameter decreased significantly after AVR but remained increased at late follow-up. Interstitial fibrosis was increased preoperatively and increased even further early but decreased late after AVR. Fibrosis was positively linearly correlated to myocardial stiffness and inversely correlated to LV ejection fraction. CONCLUSIONS: Patients with aortic regurgitation show normalization of macroscopic LV hypertrophy late after AVR, although fiber hypertrophy persists. These changes in LV myocardial structure late after AVR are accompanied by a change in passive elastic properties with persistent diastolic dysfunction.
Resumo:
PURPOSE: To prospectively determine reproducibility of magnetic resonance (MR) angiography and MR spectroscopy of deoxymyoglobin in assessment of collateral vessels and tissue perfusion in patients with critical limb ischemia (CLI) and to follow changes in patients undergoing intramuscular vascular endothelial growth factor (pVEGF)-C gene therapy, percutaneous transluminal angioplasty, supervised exercise training, or no therapy. MATERIALS AND METHODS: Study and gene therapy protocols were approved, and all patients gave written informed consent. To determine repeatability and reproducibility, seven patients underwent MR angiography and five underwent MR spectroscopy. The techniques were used to judge disease progress in 12 other patients with or without therapy: MR angiography to help determine change in visualization of collateral vessels and MR spectroscopy to help assess change in perfusion at proximal and distal calf levels. MR angiographic results were subjectively analyzed by three blinded readers. Intraobserver variability was expressed as 95% confidence interval (CI) (n=7); interobserver variability, as kappa statistic (n=15). Reexamination variability of MR spectroscopy was given as 95% CI for subsequent recovery times, and correlation with disease extent was calculated with Kendall taub rank correlation. Fisher-Yates test was used to correlate changes with pressure measurements and clinical course. RESULTS: Intraobserver and interobserver concordance was sensitive for detection of collateral vessels. Intraobserver agreement was 85.7% (95% CI: 42.1%, 99.6%). Interobserver agreement was high for small collateral vessels (kappa=0.74, P <.001) and fair for large collateral vessels (kappa=0.36, P=.002). MR spectroscopy was reproducible (95% CI: +/-26 seconds for proximal, +/-21 seconds for distal) and showed a correlation with disease extent (proximal calf, taub=0.84, P <.001; distal calf, taub=0.68, P=.04). Small collateral vessels increased over time (P=.04) but did not correlate with pressure measurements and clinical course. Recovery time correlated with clinical course (proximal calf, P=.03; distal calf, P=.005). CONCLUSION: MR angiography and MR spectroscopy of deoxymyoglobin can help document changes in visualization of collateral vessels and tissue perfusion in patients with CLI.
Resumo:
Hyperkalemia is a common life-threatening problem in hemodialysis patients. Because glycyrrhetinic acid (GA) inhibits the enzyme 11beta-hydroxy-steroid dehydrogenase II and thereby increases cortisol availability to the colonic mineralocorticoid receptor, it has the potential to lower serum potassium concentrations. To test this, 10 patients in a 6 month prospective, double-blind, placebo-controlled crossover study were given cookies or bread rolls supplemented with glycyrrhetinic acid or placebo. Twenty-four-hour blood pressure measurements were performed at baseline and week 6 and 12 of each treatment period. The ratio of plasma cortisol/cortisone was significantly increased in all patients on GA as compared to baseline or placebo, indicating appropriate enzyme inhibition. Nine of the 10 patients had a persistent decrease in predialysis serum potassium concentration. On GA, mean predialysis serum potassium was significantly lower than at baseline or on placebo. On placebo, serum potassium was significantly elevated above the upper limit of normal in 76% compared to 30% of measurements during GA treatment. Furthermore, on this treatment the frequency of severe hyperkalemia significantly decreased from 9% to 0.6%. No differences were found in parameters reflecting sodium retention. Although these studies show that prolonged GA supplementation persistently lowers serum potassium in dialysis patients, a long-term toxicity study will be mandatory before we recommend the routine use of this treatment.
Resumo:
OBJECTIVE To determine whether myocardial contrast echocardiography can be used to quantify collateral derived myocardial flow in humans. METHODS In 25 patients undergoing coronary angioplasty, a collateral flow index (CFI) was determined using intracoronary wedge pressure distal to the stenosis to be dilated, with simultaneous mean aortic pressure measurements. During balloon occlusion, echo contrast was injected into both main coronary arteries simultaneously. Echocardiography of the collateral receiving myocardial area was performed. The time course of myocardial contrast enhancement in images acquired at end diastole was quantified by measuring pixel intensities (256 grey units) within a region of interest. Perfusion variables, such as background subtracted peak pixel intensity and contrast transit rate, were obtained from a fitted gamma variate curve. RESULTS 16 patients had a left anterior descending coronary artery stenosis, four had a left circumflex coronary artery stenosis, and five had a right coronary artery stenosis. The mean (SD) CFI was 19 (12)% (range 0-47%). Mean contrast transit rate was 11 (8) seconds. In 17 patients, a significant collateral contrast effect was observed (defined as peak pixel intensity more than the mean + 2 SD of background). Peak pixel intensity was linearly related to CFI in patients with a significant contrast effect (p = 0.002, r = 0.69) as well as in all patients (p = 0.0003, r = 0.66). CONCLUSIONS Collateral derived perfusion of myocardial areas at risk can be demonstrated using intracoronary echo contrast injections. The peak echo contrast effect is directly related to the magnitude of collateral flow.
Resumo:
OBJECTIVE Well-developed collaterals provide survival benefit in patients with obstructive coronary artery disease (CAD). Therefore, in this study we sought to determine which clinical variables are associated with arteriogenesis. DESIGN Clinical and laboratory variables were collected before percutaneous coronary intervention. Multivariate analysis was performed to determine which variables are associated with the collateral flow index (CFI). PATIENTS Data from 295 chronic total occlusion (CTO) patients (Bern, Switzerland, Amsterdam, the Netherlands and Jena, Germany) were pooled. In earlier studies, patients had varying degrees of stenosis. Therefore, different stages of development of the collaterals were used. In our study, a unique group of patients with CTO was analysed. INTERVENTIONS Instead of angiography used earlier, we used a more accurate method to determine CFI using intracoronary pressure measurements. CFI was calculated from the occlusive pressure distal of the coronary lesion, the aortic pressure and central venous pressure. RESULTS The mean CFI was 0.39 ± 0.14. After multivariate analysis, β blockers, hypertension and angina pectoris duration were positively associated with CFI (B: correlation coefficient β=0.07, SE=0.03, p=0.02, B=0.040, SE=0.02, p=0.042 and B=0.001, SE=0.000, p=0.02). Furthermore also after multivariate analysis, high serum leucocytes, prior myocardial infarction and high diastolic blood pressure were negatively associated with CFI (B=-0.01, SE=0.005, p=0.03, B=-0.04, SE=0.02, p=0.03 and B=-0.002, SE=0.001, p=0.011). CONCLUSIONS In this unique cohort, high serum leucocytes and high diastolic blood pressure are associated with poorly developed collaterals. Interestingly, the use of β blockers is associated with well-developed collaterals, shedding new light on the potential action mode of this drug in patients with CAD.
Resumo:
OBJECTIVES Thoracic epidural analgesia (TEA) has been shown to inhibit detrusor activity in patients undergoing open renal surgery, resulting in clinically relevant post-void residuals. However, the impact of different epidural drug mixtures on urethral sphincter function is not completely elucidated. DESIGN Pooled analysis of an open observational study and a double-blind randomized trial. SETTING Single tertiary centre. SUBJECTS Twenty-eight women without lower urinary tract symptoms and post-void residual <100 mL, who underwent open renal surgery with TEA. METHODS Pooling results in three groups with different epidural regimens (7 with bupivacaine 0.125%, 8 with bupivacaine 0.125% and fentanyl 2 μg/mL, and 13 with bupivacaine 0.1% plus fentanyl 2 μg/mL and epinephrine 2 μg/mL). All women underwent urethral pressure measurements before TEA and during TEA 2-3 days postoperatively. All patients received a TEA placed at the insertion site interspace T 8-9. RESULTS Maximum urethral closure pressure at rest decreased significantly during TEA with bupivacaine alone (median 70 cm H2 O [interquartile range 66-76] to 43 [43-65], P = 0.031) and with bupivacaine/fentanyl/epinephrine (75 cm H2 O [68-78] to 56 [52-75], P = 0.028), whereas with bupivacaine/fentanyl, no significant change could be detected (74 [51-88] vs 67 [46-70], P = 0.156). In all groups, functional profile length at rest was not influenced during TEA. CONCLUSION TEA with bupivacaine and the addition of fentanyl and epinephrine appears to decrease maximum urethral closure pressure at rest in women. The addition of fentanyl alone to bupivacaine may reduce this effect. Thus, the TEA effect on urethral sphincter function seems to depend on the drug mixture administered.
Resumo:
The coronary collateral circulation is an alternative source of blood supply to a myocardial area jeopardized by the failure of the stenotic or occluded vessel to provide enough blood flow to this region. Until recently, only qualitative or semiqualitative methods have been available for the assessment of the coronary collateral circulation in humans, such as the patient's history of walk-through angina pectoris, the registration of intracoronary ECG signs for myocardial ischaemia or angina pectoris during coronary occlusion, or coronary angiographic classification (score 0-3) of collaterals. Studies of coronary wedge pressure measurements distal of a balloon-occluded coronary artery and the recent advent of ultrathin pressure and Doppler angioplasty guidewires have made it possible to obtain pressure or flow velocity data in remote vascular areas and, thus, to calculate functional variables for coronary collateral flow. Those coronary occlusive pressure- and flow velocity-derived parameters express collateral flow as a fraction of antegrade coronary flow during vessel patency of the collateral-receiving vessel. They are both interchangeable, and they have been validated in comparison to 'traditional' methods and against each other. The possibility of accurately measuring coronary collateral flow indices in humans undergoing coronary balloon angioplasty opens areas of investigation of the pathogenesis, pathophysiology and therapeutic promotion of the collateral circulation previously reserved for exclusively experimental studies. The purpose of this article is to review several clinically available methods for the functional characterization of the coronary collateral circulation.