943 resultados para peak accelerations


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A data manipulation method has been developed for automatic peak recognition and result evaluation in the analysis of organic chlorinated hydrocarbons with dual-column gas chromatography. Based on the retention times of two internal standards, pentachlorotoluene and decachlorobiphenyl, the retention times of chlorinated hydrocarbons can be calibrated automatically and accurately. It is very convenient to identify the peaks by comparing the retention times of samples with the calibrated retention times calculated from the relative retention indices of standards. Meanwhile, with a suggested two-step evaluation method the evaluation coefficients and the suitable quantitative results of each component can be automatically achieved for practical samples in an analytical system using two columns with different polarities and two internal standards. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Performance of comprehensive two-dimensional liquid chromatography system is greatly improved than we reported previously by using a silica monolithic column as for the second dimensional separation. Due to the increase of the elution speed on the second dimensional monolithic column, the first dimensional column efficiency and analysis rate can be greatly improved as comparing with conventionally second dimensional column. The developed system was applied to analysis of methanol extraction of two umbelliferae herbs Ligusticum chuanxiong Hort. and Angelica sinensis (Oliv.) Diels by using CN column as for the first dimensional separation and a silica monolithic ODS column for the second dimensional separation, and the obtained three-dimensional chromatograms were treated by normalization of peak heights with the value of the highest peak or setting a certain value using a software written in-house. It was observed that much more peaks for low-abundant components in TCM extract can clearly be detected here than we reported before, due to the large difference for the amount of components in TCMs' extract. With the above improvements in separation performance and data treatment, totally about 120 components in methanol extraction of Rhizoma chuanxiong and 100 in A. sinensis were separated with UV detection within 130 min. This result meant that both the number of peaks detected increase twice but the analysis time decease twice if comparing with the previously reported result. (c) 2005 Published by Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Jenkins, H., Beckmann, M., Draper, J., & Hardy, N. (2007). GC-MS Peak Labeling Under ArMet. Nikolau, B. J., & Wurtele, E. S. (Eds.), In: Concepts in Plant Metabolomics. (pp. 19-28). Dordrecht: Springer. Sponsorship: The authors gratefully acknowledge the United Kingdom Food Standards Agency (under the G02006 project) for support of their work in metabolomics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thatcher, Rhys, et al., 'Influence of blood donation on O-2 uptake on-kinetics, peak O-2 uptake and time to exhaustion during severe-intensity cycle exercise in humans', Experimental Physiology (2006) 91(3) pp.499-509 RAE2008

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Burnley, M., Doust, J., Vanhatalo, A., A 3-min all-out test to determine peak oxygen uptake and the maximal steady state, Medicine & Science in Sports & Exercise. 38(11):1995-2003, November 2006. RAE2008

Relevância:

20.00% 20.00%

Publicador:

Resumo:

http://www.archive.org/details/equatorssnowype00crawuoft

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thermal-optical analysis is a conventional method for classifying carbonaceous aerosols as organic carbon (OC) and elemental carbon (EC). This article examines the effects of three different temperature protocols on the measured EC. For analyses of parallel punches from the same ambient sample, the protocol with the highest peak helium-mode temperature (870°C) gives the smallest amount of EC, while the protocol with the lowest peak helium-mode temperature (550°C) gives the largest amount of EC. These differences are observed when either sample transmission or reflectance is used to define the OC/EC split. An important issue is the effect of the peak helium-mode temperature on the relative rate at which different types of carbon with different optical properties evolve from the filter. Analyses of solvent-extracted samples are used to demonstrate that high temperatures (870°C) lead to premature EC evolution in the helium-mode. For samples collected in Pittsburgh, this causes the measured EC to be biased low because the attenuation coefficient of pyrolyzed carbon is consistently higher than that of EC. While this problem can be avoided by lowering the peak helium-mode temperature, analyses of wood smoke dominated ambient samples and levoglucosan-spiked filters indicate that too low helium-mode peak temperatures (550°C) allow non-light absorbing carbon to slip into the oxidizing mode of the analysis. If this carbon evolves after the OC/EC split, it biases the EC measurements high. Given the complexity of ambient aerosols, there is unlikely to be a single peak helium-mode temperature at which both of these biases can be avoided. Copyright © American Association for Aerosol Research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The calanoid copepod Neocalan us plumchrus (Marukawa) is a dominant member of the spring mesozooplankton in the subarctic North Pacific and Bering Sea. Previous studies have shown interdecadal and latitudinal variation in seasonal developmental timing, with peak biomass occurring earlier in years and places with warmer upper ocean temperatures. Because N. plumchrus normally has a single dominant annual cohort, its seasonal timing can be indexed from measurements of total population biomass or by following progressive changes in stage composition. Early studies empirically found that peak upper ocean biomass occurred when about half of the pre-dormant population had reached copepodite stage 5 (C5). However, more recent comparisons derived from recent Continuous Plankton Recorder (CPR) data now show peak biomass when a larger fraction (> 80%) of the population is at C5. CPR samples the surface 10 to 15 m, but comparisons to depth-resolved BIONESS data show that this discrepancy is not an artefact of sampling depth. Other causes are either a prolongation of duration of pre-dormant C5 or a narrowing of the age range making up the annual cohort. We assessed changes in cohort width using a modification of Greve's cumulative percentile method, and found that average cohort widths in the Alaska Gyre were significantly narrower in 2000-2007 than in 1957-1965 (1968-1980 were intermediate). Net tow sampling of Strait of Georgia populations showed a similar significant narrowing of cohorts in the 2003-2005 sampling period. This study provides evidence that in addition to the shift to an earlier occurrence of peak biomass reported previously, the duration of the peak has also decreased in the last decade.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Effective collision strengths are presented for the Fe-peak element Fe III at electron temperatures (Te in degrees Kelvin) in the range 2 × 103 to 1 × 106. Forbidden transitions results are given between the 3d6, 3d54s, and the 3d54p manifolds applicable to the modeling of laboratory and astrophysical plasmas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A refined theoretical approach has been developed to study the double-differential cross sections (DDCS's) in proton-helium collisions as a function of the ratio of ionized electron velocity to the incident proton velocity. The refinement is done in the present coupled-channel calculation by introducing a continuum distorted wave in the final state coupled with discrete states including direct as well as charge transfer channels. It is confirmed that the electron-capture-to-the-continuum (ECC) peak is slightly shifted to a lower electron velocity than the equivelocity position. Comparing measurements and classical trajectory Monte Carlo (CTMC) calculations at 10 and 20 keV proton energies, excellent agreement of the ECC peak heights is achieved at both energies. However, a minor disagreement in the peak positions between the present calculation and the CTMC results is noted. A smooth behavior of the DDCS is found in the present calculation on both sides of the peak whereas the CTMC results show some oscillatory behavior particularly to the left of the peak, associated with the statistical nature of CTMC calculations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper discusses the calculation of electron impact collision strengths and effective collision strengths for iron peak elements of importance in the analysis of many astronomical and laboratory spectra. It commences with a brief overview of R-matrix theory which is the basis of computer programs which have been widely used to calculate the relevant atomic data used in this analysis. A summary is then given of calculations carried out over the last 20 y for electron collisions with Fe II. The grand challenge, represented by the calculation of accurate collision strengths and effective collision strengths for this ion, is then discussed. A new parallel R-matrix program PRMAT, which is being developed to meet this challenge, is then described and results of recent calculations, using this program to determine optically forbidden transitions in e- – Ni IV on a Cray T3E-1200 parallel supercomputer, are presented. The implications of this e- – Ni IV calculation for the determination of accurate data from an isoelectronic e- – Fe II calculation are discussed and finally some future directions of research are reviewed.