870 resultados para optical spatial solitons
Resumo:
A theoretical investigation of the nonlinear copropagation of two optical pulses of different frequencies in a photonic crystal fiber is presented. Different phenomena are observed depending on whether the wavelength of the signal pulse is located in the normal or the anomalous dispersion region. In particular, it is found that the phenomenon of pulse trapping occurs when the signal wavelength is located in the normal dispersion region while the pump wavelength is located in the anomalous dispersion region. The signal pulse suffers cross-phase modulation by the Raman shifted soliton pulse and it is trapped and copropagates with the Raman soliton pulse along the fiber. As the input peak power of the pump pulse is increased, the red-shift of the Raman soliton is considerably enhanced with the simultaneous further blue-shift of the trapped pulse to satisfy the condition of group velocity matching.
Resumo:
We have experimentally demonstrated pulses 0.4 mJ in duration smaller than 12 fs; with an excellent spatial beam profile by self-guided propagation in argon. The original 52 fs pulses from the chirped pulsed amplification laser system are first precompressed to 32 fs by inserting an acoustic optical programmable dispersive filter instrument into the laser system for spectrum reshaping and dispersion compensation, and the pulse spectrum is subsequently broadened by filamentation in an argon cell. By using chirped mirrors for post-dispersion compensation, the pulses are successfully compressed to smaller than 12 fs.
Resumo:
Optical microscopy has become an indispensable tool for biological researches since its invention, mostly owing to its sub-cellular spatial resolutions, non-invasiveness, instrumental simplicity, and the intuitive observations it provides. Nonetheless, obtaining reliable, quantitative spatial information from conventional wide-field optical microscopy is not always intuitive as it appears to be. This is because in the acquired images of optical microscopy the information about out-of-focus regions is spatially blurred and mixed with in-focus information. In other words, conventional wide-field optical microscopy transforms the three-dimensional spatial information, or volumetric information about the objects into a two-dimensional form in each acquired image, and therefore distorts the spatial information about the object. Several fluorescence holography-based methods have demonstrated the ability to obtain three-dimensional information about the objects, but these methods generally rely on decomposing stereoscopic visualizations to extract volumetric information and are unable to resolve complex 3-dimensional structures such as a multi-layer sphere.
The concept of optical-sectioning techniques, on the other hand, is to detect only two-dimensional information about an object at each acquisition. Specifically, each image obtained by optical-sectioning techniques contains mainly the information about an optically thin layer inside the object, as if only a thin histological section is being observed at a time. Using such a methodology, obtaining undistorted volumetric information about the object simply requires taking images of the object at sequential depths.
Among existing methods of obtaining volumetric information, the practicability of optical sectioning has made it the most commonly used and most powerful one in biological science. However, when applied to imaging living biological systems, conventional single-point-scanning optical-sectioning techniques often result in certain degrees of photo-damages because of the high focal intensity at the scanning point. In order to overcome such an issue, several wide-field optical-sectioning techniques have been proposed and demonstrated, although not without introducing new limitations and compromises such as low signal-to-background ratios and reduced axial resolutions. As a result, single-point-scanning optical-sectioning techniques remain the most widely used instrumentations for volumetric imaging of living biological systems to date.
In order to develop wide-field optical-sectioning techniques that has equivalent optical performance as single-point-scanning ones, this thesis first introduces the mechanisms and limitations of existing wide-field optical-sectioning techniques, and then brings in our innovations that aim to overcome these limitations. We demonstrate, theoretically and experimentally, that our proposed wide-field optical-sectioning techniques can achieve diffraction-limited optical sectioning, low out-of-focus excitation and high-frame-rate imaging in living biological systems. In addition to such imaging capabilities, our proposed techniques can be instrumentally simple and economic, and are straightforward for implementation on conventional wide-field microscopes. These advantages together show the potential of our innovations to be widely used for high-speed, volumetric fluorescence imaging of living biological systems.
Resumo:
The spatial longitudinal coherence length (SLCL), which is determined by the size of and the distance from the source, is introduced to investigate the longitudinal resolution of lensless ghost imaging. Its influence is discussed quantitatively by simulation. The discrepancy of position sensitivity between Scareelli et al. [Appl. Phys. Lett. 88, 061106 (2006)] and Basano and Ottonello [Appl. Phys. Lett. 88, 091109 (2006)] is clarified. (C) 2008 Optical Society of America.
Resumo:
Intrinsically fuzzy morphological erosion and dilation are extended to a total of eight operations that have been formulated in terms of a single morphological operation--biased dilation. Based on the spatial coding of a fuzzy variable, a bidirectional projection concept is proposed. Thus, fuzzy logic operations, arithmetic operations, gray-scale dilation, and erosion for the extended intrinsically fuzzy morphological operations can be included in a unified algorithm with only biased dilation and fuzzy logic operations. To execute this image algebra approach we present a cellular two-layer processing architecture that consists of a biased dilation processor and a fuzzy logic processor. (C) 1996 Optical Society of America
Resumo:
On the basis of signed-digit negabinary representation, parallel two-step addition and one-step subtraction can be performed for arbitrary-length negabinary operands.; The arithmetic is realized by signed logic operations and optically implemented by spatial encoding and decoding techniques. The proposed algorithm and optical system are simple, reliable, and practicable, and they have the property of parallel processing of two-dimensional data. This leads to an efficient design for the optical arithmetic and logic unit. (C) 1997 Optical Society of America.
Resumo:
Based on the two-step modified signed-digit (MSD) algorithm, we present a one-step algorithm for the parallel addition and subtraction of two MSD numbers. This algorithm is reached by classifying the three neighboring digit pairs into 10 groups and then making a decision on the groups. It has only a look-up truth table, and can be further formulated by eight computation rules. A joint spatial encoding technique is developed to represent both the input data and the computation rules. Furthermore, an optical correlation architecture is suggested to implement the MSD adder in parallel. An experimental demonstration is also given. (C) 1996 Society of Photo-Optical instrumentation Engineers.
Resumo:
A 2-D SW-banyan network is introduced by properly folding the 1-D SW-banyan network, and its corresponding optical setup is proposed by means of polarizing beamsplitters and 2-D phase spatial light modulators. Then, based on the characteristics and the proposed optical setup, the control for the routing path between any source-destination pair is given, and the method to determine whether a given permutation is permissible or not is discussed. Because the proposed optical setup consists of only optical polarization elements, it is compact in structure, its corresponding energy loss and crosstalk are low, and its corresponding available number of channels is high. (C) 1996 Society of Photo-Optical Instrumentation Engineers.
Resumo:
The routing scheme and some permutation properties of a four-shuffle-exchange-based Omega network are discussed. The corresponding optical setup, which is composed of 2-D phase spatial light modulators and calcite plates, is proposed and demonstrated through mapping the inputs to a 2-D array. Instead of one shuffle-exchange followed by one switching operation as in ordinary Omega networks, in our presented system, the shuffle interconnection embraced in the switches is accomplished simply by varying the switching structure of each stage. For the proposed polarization-optical modules, the system is compact in structure, efficient in performance, and insensitive to the environment. (C) 1997 Society of Photo-Optical Instrumentation Engineers.
Resumo:
[EN]For a good development of elastic optical networks, the design of flexible optical switching nodes is required. This work analyses the previously proposed flexible architectures and, based on the most appropriate, which is the Architecture on Demand (AoD), proposes a specific configuration of the node that includes spatial and spectral switching and the wavelength conversion functionality with a low blocking probability and the minimum amount of modules; the characteristics of the traffic that the designed node is able to cope with are specified in the last chapter. An evaluation of the designed node is also done, and, compared to the other architectures, it is shown that the Architecture on Demand gives better results than others and that it has a higher potential for future developments.
Resumo:
Spatial coherence properties of beam produced by Gaussian Schell-model source when the beam is propagating through atmosphere have been analyzed in terms of position vectors. New expressions for cross-spectral density of optical field and spectral degree of coherence as well as radiant intensity have been developed. Numerical results illustrated in this paper indicate the coherence degradation suffered from atmospheric turbulence and their directional dependence. (C) 2007 Elsevier GmbH. All rights reserved.
Resumo:
Microstructure optical fibers with flat-top fundamental mode are first proposed by introducing a low-index inner core into the core of index-guiding microstructure optical fibers. The design guidelines and characteristics of beam-shaping microstructure optical fibers are demonstrated. The interrelationships of inner-core index with laser wavelength, air hole diameter and size of inner core are investigated. The influence of the relative size of inner core on the spatial profile of the fundamental mode is demonstrated. Moreover, sensitivity of the flat-top fundamental mode profile from the slight change of the optimum inner-core index value is studied. Starting from these results we deduce that it is possible to fabricate beam-shaping microstructure fibers with nowadays technique. (C) 2005 Elsevier B.V. All rights reserved.
Resumo:
A relatively simple scheme for disk-type photopolymer high-density holographic storage based on angular and spatial multiplexing is described. The effects of the optical setup on the recording capacity and density are studied. Calculations and analysis show that this scheme is more effective than a scheme based on the spatioangular multiplexing for disk-type photopolymer high-density holographic storage, which has a limited medium thickness. Also an optimal beam recording angle exists to achieve maximum recording capacity and density. (C) 2002 Society of Photo-Optical Instrumentation Engineers.
Resumo:
In a configuration of optical far-field scanning microscopy, super-resolution achieved by inserting a third-order optical nonlinear thin film is demonstrated and analyzed in terms of the frequency response function. Without the thin film the microscopy is diffraction limited; thus, subwavelength features cannot be resolved. With the nonlinear thin film inserted, the resolution is dramatically improved and thus the microscopy resolves features significantly smaller than the smallest spacing allowed by the diffraction limit. A theoretical model is established and the device is analyzed for the frequency response function. The results show that the frequency response function exceeds the cutoff spatial frequency of the microscopy defined by the laser wavelength and the numerical aperture of the convergent lens. The main contribution to the improvement of the cutoff spatial frequency is from the phase change induced by the complex transmission of the nonlinear thin film. Experimental results are presented and are shown to be consistent with the results of theoretical simulations.