925 resultados para olfactory detection of conspecifics
Resumo:
Using the Roche LightCycler we developed a real-time reverse transcriptase polymerase chain reaction (RT-PCR) assay using the Influenza A LightCycler RT-PCR (FA-LC-RTPCR) for the rapid detection of Influenza A. The assay was used to examine 178 nasopharyngeal aspirate (NPA) samples, from patients with clinically recognised respiratory tract infection, for the presence of Influenza A RNA. The results were then compared to a testing algorithm combining direct immunofluorescent assy (DFA) and a culture augmented DFA (CA-DFA) assay. In total, 76 (43%) specimens were positive and 98 (55%) specimens were negative by both the FA-LC-RTPCR and the DFA and CA-DFA algorithm. In addition, the FA-LC-RTPCR detected a further 4 (2%) positive specimens, which were confirmed by a conventional RT-PCR method. The high level of sensitivity and specificity, combined with the rapid turnaround time for results, makes the LC-RT-PCR assay suitable for the detection of Influenza A in clinical specimens.
Resumo:
The recent description of the respiratory pathogen human metapneumovirus (hMPV) has highlighted a deficiency in current diagnostic techniques for viral agents associated with acute lower respiratory tract infections. We describe two novel approaches to the detection of viral RNA by use of reverse transcriptase PCR (RT-PCR). The PCR products were identified after capture onto a solid-phase medium by hybridization with a sequence-specific, biotinylated oligonucleotide probe. The assay was applied to the screening of 329 nasopharyngeal aspirates sampled from patients suffering from respiratory tract disease. These samples were negative for other common microbial causes of respiratory tract disease. We were able to detect hMPV sequences in 32 (9.7%) samples collected from Australian patients during 2001. To further reduce result turnaround times we designed a fluorogenic TaqMan oligoprobe and combined it with the existing primers for use on the LightCycler platform. The real-time RT-PCR proved to be highly reproducible and detected hMPV in an additional 6 out of 62 samples (9.6%) tested during the comparison of the two diagnostic approaches. We found the real-time RT-PCR to be the test of choice for future investigation of samples for hMPV due to its speed, reproducibility, specificity, and sensitivity.
Resumo:
Three Herpes Simplex Virus LightCycler polymerase chain reaction assays were compared for the detection of herpes simplex virus in 48 swab specimens. The assays comprised of one in-house assay and two commercial kits: the Artus HSV LC RealArt PCR kit and the Roche LightCycler HSV 1/2 Detection kit. On the whole, the three assays had comparable sensitivities. However, differentiation of herpes simplex virus types 1 and 2 by melting curve analysis was problematic in all assays. Overall, the results highlight the limitations of typing herpes simplex virus by melting curve analysis.
Resumo:
We report the development of epitope-blocking enzyme-linked immunosorbent assays (ELISAs) for the rapid detection of serum antibodies to West Nile virus (WNV) in taxonomically diverse North American avian species. A panel of flavivirus-specific monoclonal antibodies (MAbs) was tested in blocking assays with serum samples from WNV-infected chickens and crows. Selected MAbs were further tested against serum samples from birds that represented 16 species and 10 families. Serum samples were collected from birds infected with WW or Saint Louis encephalitis virus (SLEV) and from noninfected control birds. Serum samples from SLEV-infected birds were included in these experiments because WNV and SLEV are closely related antigenically, are maintained in similar transmission cycles, and have overlapping geographic distributions. The ELISA that utilized MAb 3.11126 potentially discriminated between WW and SLEV infections, as all serum samples from WNV-infected birds and none from SLEV-infected birds were positive in this assay. Assays with MAbs 2132 and 6B6C-1 readily detected serum antibodies in all birds infected with WNV and SLEV, respectively, and in most birds infected with the other virus. Two other MAbs partially discriminated between infections with these two viruses. Serum samples from most WNV-infected birds but no SLEV-infected birds were positive with MAb 3.676, while almost all serum samples from SLEV-infected birds but few from WNV-infected birds were positive with MAb 6B5A-5. The blocking assays reported here provide a rapid, reliable, and inexpensive diagnostic and surveillance technique to monitor WNV activity in multiple avian species.
Resumo:
We evaluated the ability of epitope-blocking enzyme-linked immunosorbent assays (ELISAs) to detect West Nile virus (WNV) antibodies in domestic mammals. Sera were collected from experimentally infected horses, cats, and pigs at regular intervals and screened in ELISAs and plaque reduction neutralization tests. The diagnostic efficacies of these techniques were similar.
Resumo:
A blocking ELISA targeting an immunodominant West Nile epitope on the West Nile Virus NS1 protein was assessed for the detection of West Nile-specific antibodies in blood samples collected from 584 sentinel chickens and 238 wild birds collected in-New Jersey from May-December 2000. Ten mallard ducks (Anas platyrhynchos) experimentally infected with West Nile virus and six uninfected controls were also tested. The ELISA proved specific in detecting WNV antibodies in 9/10 chickens and 4/4 wild birds previously confirmed as positive by Plaque Reduction Neutralization test (PRNT) at the Center for Disease Control, Division of Vector Borne Diseases, Fort Collins, CO, USA (CDC). Nine out of the ten experimentally infected mallard ducks also tested positive for WN antibodies in the blocking ELISA, while 6/6 uninfected controls did not. Additionally, 1705 wild birds, collected in New Jersey from December 2000-November 2001 and Long Island, New York between November 1999 and August 2001 were also tested for WN antibodies by the blocking ELISA. These tests identified 30 positive specimens, 12 of which had formalin-fixed tissues available to allow detection of WN specific viral antigen in various tissues by WNV-specific immunohistochemistry. Our results indicate that rapid and specific detection of antibodies to WN virus in sera from a range of avian species by blocking ELISA is an effective strategy for WN Virus surveillance in avian hosts. In combination with detection of WN-specific antigens in tissues by immunohistochemistry (IHC) the blocking ELISA will also be useful for confirming WN infection in diseased birds.
Resumo:
Background Wide testing of the aldosterone: renin ratio among hypertensive individuals has revealed primary aldosteronism to be common, with most patients normokalaemic. Some investigators, however, have reported aldosterone-producing adenoma to be rare among patients so detected. Objective To test the hypothesis that differences among reported studies in the rate of detection of aldosterone-producing adenoma (as opposed to bilateral adrenal hyperplasia) reflect differences in the procedures used for diagnosis of primary aldosteronism, and the methods used to identify aldosterone-producing adenomas. Methods In the newly established Princess Alexandra Hospital Hypertension Unit (PAHHU), we used procedures developed by Greenslopes Hospital Hypertension Unit (which reports that more than 30% of patients with primary aldosteronism have aldosterone-producing adenomas) to diagnose primary aldosteronism and determine the subtype. All patients with an increased aldosterone: renin ratio (measured after correction for hypokalaemia and while the patient was not receiving interfering medications) underwent fludrocortisone suppression testing to confirm or exclude primary aldosteronism; if they were positive, they underwent genetic testing to exclude glucocorticoid-remediable aldosteronism before adrenal venous sampling was used to differentiate lateralizing from bilateral primary aldosteronism. Results This approach allowed PAHHU to diagnose, within 2 years, 54 patients [only seven (13%) hypokalaemic] with primary aldosteronism. All tested negative for glucocorticoid-remediable aldosteronism. Aldosterone production was lateralized to one adrenal in 15 patients (31%; only six hypokalaemic) and was bilateral in 34 (69%; all normokalaemic) of 49 patients who underwent adrenal venous sampling. Among patients with lateralizing adrenal hyperplasia, computed tomography revealed an ipsilateral mass in only six and a contralateral lesion in one. Fourteen patients underwent unilateral adrenalectomy, which cured the hypertension in seven and improved it in the remainder. In patients with bilateral primary aldlosteronism, hypertension responded to spironolactone (112.5-50 mg/ day) or amiloride (2.5-10 mg/day). Conclusion When performed with careful regard to confounding factors, measurement of the aldosterone: renin ratio in all hypertensive individuals, followed by fludrocortisone suppression testing to confirm or exclude primary aldosteronism and adrenal venous sampling to determine the subtype, can result in the detection of significant numbers of patients with specifically treatable or potentially curable hypertension. (C) 2003 Lippincott Williams Wilkins.
Resumo:
The aims of this study were a) to assess the ability of primary care doctors to make accurate ratings of psychiatric disturbance and b) to evaluate the use of a case-finding questionnaire in the detection of psychiatric morbidity. The estudy took place in three primary care clinics in the city of São Paulo, Brazil, during a six-month survey. A time sample of consecutive adult attenders were asked to complete a case-finding questionnaire for psychiatric disorders (the Self Report Questionnaire - SRQ) and a subsample were selected for a semi-structured psychiatric interview (the Clinical Interview Schedule - CIS). At the end of the consultation the primary care doctors were asked to assess, in a standardized way, the presence or absence of psychiatric disorder; these assessments were then compared with that ratings obtained in the psychiatric interview. A considerable proportion of minor psychiatric morbidity remained undetected by the three primary care doctors: the hidden morbidity ranged from 22% to 79%. When these were compared to those of the case-finding questionnaire, they were consistently lower, indicating that the use of these instruments can enhance the recognition of psychiatric disorders in primary care settings. Four strategies for adopting the questionnaire are described, and some of the clinical consequences of its use are discussed.
Resumo:
A series of studies in the field of Epidemiological Psychiatry have been performed over the last two decades, and these have focused on the ability of primary care physicians to detect emotional disorders in the patients that attend their practices. The scientific methodology utilized in these studies is the subject of this review, which contains a discussion concerning: a) interviewer awareness bias; b) accuracy of the instruments and c) medical and psychological concepts involved in defining minor emotional disorders. Suggestions for change in the methodology are made in each of the sections of the review.
Resumo:
In this paper we present an amorphous silicon device that can be used in two operation modes to measure the concentration of ions in solution. While crystalline devices present a higher sensitivity, their amorphous counterpart present a much lower fabrication cost, thus enabling the production of cheap disposable sensors for use, for example, in the food industry. The devices were fabricated on glass substrates by the PECVD technique in the top gate configuration, where the metallic gate is replaced by an electrolytic solution with an immersed Ag/AgCl reference electrode. Silicon nitride is used as gate dielectric enhancing the sensitivity and passivation layer used to avoid leakage and electrochemical reactions. In this article we report on the semiconductor unit, showing that the device can be operated in a light-assisted mode, where changes in the pH produce changes on the measured ac photocurrent. In alternative the device can be operated as a conventional ion selective field effect device where changes in the pH induce changes in the transistor's threshold voltage.
Resumo:
Cryptosporidium sp., a coccidian parasite usually found in the faeces of cattle, has been recently implicated as an agent of human intestinal disease, mainly in immunocompromised patients. In the study realized, by an indirect immunofluorescence technique, specific immunoglobulins (IgG and IgM) have been demonstrated in human serum against Cryptosporidium oocysts. Purified oocysts were used as antigens in the indirect immunofluorecence assay. After analyzing this test in sera from selected groups of patients, the frequency of both specific IgG and IgM of immunocompetent children who were excreting oocysts in their faeces was 62% and in children with negative excretion of oocysts was 20% and 40%, respectively. In adults infected with the human immunodeficiency virus (HIV) and who were excreting Cryptosporidium in their stools, the frequency was 57% for IgG but only 2% for IgM. Twenty three percent of immunocompromised adults with not determined excretion of oocysts in their stools had anti-Cryptosporidium IgG in their sera. Children infected with human immunodeficiency virus had no IgM and only 14% had IgG detectable in their sera. The indirect immunoflorescence assay, when used with other parasitological techniques appears to be useful for retrospective population studies and for diagnosis of acute infection. The humoral immune response of HIV positive patients to this protozoan agent needs clarification.
Resumo:
OBJETIVES: To detect anti-Giardia lamblia serum antibodies in healthy children attending public day care centers and to assess serological tests as tools for estimating the prevalence of G. lamblia in endemic areas. METHODS: Three separate stool specimens and filter paper blood samples were collected from 147 children ranging from 0 to 6 years old. Each stool sample was processed using spontaneous sedimentation and zinc sulfate flotation methods. Blood samples were tested by indirect immunofluorescence (IIF) and enzyme-linked immunosorbent assay (ELISA) for Giardia IgG. RESULTS AND CONCLUSIONS: Of 147 individuals tested, 93 (63.3%) showed Giardia cysts in their feces. Using IIF and ELISA, serum antibodies were detected in 93 (63.3%) and 100 (68%) samples , respectively. Sensitivity of IIF and ELISA was 82% and 72%, respectively. However, ELISA revealed to be less specific (39%) than IIF (70%). IIF also showed a higher concordance with microscopic examination than ELISA.