946 resultados para oily sanitary waste
Resumo:
Present paper present the main results obtained in the scope of an ongoing project which aims to contribute to the valorization of a waste generated by the Portuguese oil company in construction materials. This waste is an aluminosilicate with high pozzolanic reactivity. Several different technological applications had already been tested with success both in terms of properties and compliance with the corresponding standards specifications. Namely, this project results already demonstrated that this waste can be used in traditional concrete, self-compacted concrete, mortars (renders, masonry mortar, concrete repair mortars), cement main constituent as well as alkali activated binders.
Resumo:
The colony of urban stray cats living in the Rio de Janeiro zoological garden was studied in order to develop a population and health control program. As many cats as possible were captured during two months (47 animals) and were classified according to gender, age, weight and coat markings. They were submitted to a general health evaluation, examined for the presence of ectoparasites and sent to a surgical neutering program. All animals had a blood sample drawn for CBC, platelet count, heartworm and retroviruses detection. Capillary blood smears were made for hemoparasites detection. Coat marking and colors were tabby (59.7%), followed by solid black (17%); torbie (10.6%); bicolor (10.6%) and harlequin (2.1%). The only ectoparasites found were fleas, which infested 28% of the animals. The hemoparasites found were Haemobartonella felis (38%) and piroplasmas that could not be differentiated between Cytauxzoon spp. and Babesia spp. (47%). No cat was found infected by Dirofilaria immitis or FeLV (Feline Leukemia Virus), although FIV (Feline Immunodeficiency Virus) antibodies could be detected (21%). There was no correlation between hemoparasites and FIV infections. The estimated total cat population (mark-recapture method) was 59; 68% female and 32% male, suggesting that a neutering program is in fact needed.
Resumo:
O elevado consumo de água associado à escassez deste recurso contribuiu para que alternativas de reutilização/reciclagem de água fossem estudadas que permitam diminuir o seu consumo e minimizar a dependência das indústrias. Monitorizar e avaliar os consumos de água, a nível industrial, é imprescindível para assegurar uma gestão sustentável dos recursos hídricos, sendo este o objetivo da presente dissertação. As alternativas encontradas na unidade industrial em estudo foram a substituição do equipamento sanitário e o aproveitamento do efluente tratado para operações de lavagem e/ou arrefecimento por contacto direto. A maioria do equipamento sanitário não é eficiente, tendo-se proposto a substituição desse sistema por um de menor consumo que permitirá uma poupança de 30 % no consumo de água, que corresponderá a 12 149,37 €/ano, sendo o retorno do investimento estimado em 3 meses. O efluente industrial na entrada da ETAR e nas diferentes etapas - tratamento primário de coagulação/floculação; tratamento secundário ou biológico em SBR; tratamento terciário de coagulação/floculação - foi caracterizado através da medição da temperatura, pH, oxigénio dissolvido e pela determinação da cor, turvação, sólidos suspensos totais (SST), azoto total, carência química de oxigénio (CQO), Carência Bioquímica de Oxigénio ao fim de 5 dias (CBO5) e razão CBO5/CQO. Esta caracterização permitiu avaliar o efluente industrial bruto que se caracteriza por um pH alcalino (8,3 ± 1,7); condutividade baixa (451 ± 200,2 μS/cm); elevada turvação (11 255 ± 8812,8 FTU); cor aparente (63 670 ± 42293,4 PtCo) e cor verdadeira (33 621 ± 19547,9 PtCo) elevadas; teores elevados de CQO (24 753 ± 11806,7 mg/L O2) SST (5 164 ± 3845,5 mg/L) e azoto total (718 mg/L) e um índice de biodegradabilidade baixo (razão CBO5/CQO de 1,4). Este estudo permitiu verificar que a eficiência global do tratamento do efluente foi 82 % na remoção da turvação, 83 % na remoção da cor aparente, 96 % na remoção da cor verdadeira, 85 % na remoção da CQO e 30 % na remoção dos SST. Quanto às eficiências de remoção associadas ao tratamento primário no que diz respeito à turvação, cor aparente, CQO e SST, apresentam valores inferiores aos referidos na literatura para o mesmo tipo de tratamento em efluentes similares. As eficiências de remoção obtidas no tratamento secundário são inferiores às do tratamento primário: turvação, cor aparente, CQO e SST, pelo que procurou-se otimizar a primeira etapa do processo de tratamento Neste estudo de otimização estudou-se a influência de cinco coagulantes – Sulfato de Alumínio, PAX XL – 10, PAX 18, cloreto de ferro e a conjugação de PAX 18 com sulfato de ferro - e seis floculantes – Superfloc A 150, Superfloc A 130, PA 1020, Ambifloc 560, Ambifloc C58 e Rifloc 54 - no tratamento físico-químico do efluente. O PAX 18 e o Ambifloc 560 UUJ foram os que apresentaram as mais elevadas eficiências de remoção (99,85 % na cor, 99,87 % na turvação, 90,12 % na CQO e 99,87 % nos SST). O custo associado a este tratamento é de 1,03 €/m3. Pela comparação com os critérios de qualidade no guia técnico ERSAR, apenas o parâmetro da CQO excede o valor, contudo o valor obtido permite diminuir os custos associados a um tratamento posterior para remoção da CQO remanescente no efluente residual tratado.
Resumo:
Thesis submitted to the Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia for the degree of Doctor of Philosophy in Environmental Engineering
Resumo:
Collecting and transporting solid waste is a constant problem for municipalities and populations in general. Waste management should take into account the preservation of the environment and the reduction of costs. The goal with this paper is to address a real-life solid waste problem. The case reveals some general and specific characteristics which are not rare, but are not widely addressed in the literature. Furthermore, new methods and models to deal with sectorization and routing are introduced, which can be extended to other applications. Sectorization and routing are tackled following a two-phase approach. In the first phase, a new method is described for sectorization based on electromagnetism and Coulomb’s Law. The second phase addresses the routing problems in each sector. The paper addresses not only territorial division, but also the frequency with which waste is collected, which is a critical issue in these types of applications. Special characteristics related to the number and type of deposition points were also a motivation for this work. A new model for a Mixed Capacitated Arc Routing Problem with Limited Multi-Landfills is proposed and tested in real instances. The computational results achieved confirm the effectiveness of the entire approach.
Resumo:
This article deals with a real-life waste collection routing problem. To efficiently plan waste collection, large municipalities may be partitioned into convenient sectors and only then can routing problems be solved in each sector. Three diverse situations are described, resulting in three different new models. In the first situation, there is a single point of waste disposal from where the vehicles depart and to where they return. The vehicle fleet comprises three types of collection vehicles. In the second, the garage does not match any of the points of disposal. The vehicle is unique and the points of disposal (landfills or transfer stations) may have limitations in terms of the number of visits per day. In the third situation, disposal points are multiple (they do not coincide with the garage), they are limited in the number of visits, and the fleet is composed of two types of vehicles. Computational results based not only on instances adapted from the literature but also on real cases are presented and analyzed. In particular, the results also show the effectiveness of combining sectorization and routing to solve waste collection problems.
Resumo:
For efficient planning of waste collection routing, large municipalities may be partitioned into convenient sectors. The real case under consideration is the municipality of Monção, in Portugal. Waste collection involves more than 1600 containers over an area of 220 km2 and a population of around 20,000 inhabitants. This is mostly a rural area where the population is distributed in small villages around the 33 boroughs centres (freguesia) that constitute the municipality. In most freguesias, waste collection is usually conducted 3 times a week. However, there are situations in which the same collection is done every day. The case reveals some general and specific characteristics which are not rare, but are not widely addressed in the literature. Furthermore, new methods and models to deal with sectorization and routing are introduced, which can be extended to other applications. Sectorization and routing are tackled following a three-phase approach. The first phase, which is the main concern of the presentation, introduces a new method for sectorization inspired by Electromagnetism and Coulomb’s Law. The matter is not only about territorial division, but also the frequency of waste collection, which is a critical issue in these types of applications. Special characteristics related to the number and type of deposition points were also a motivation for this work. The second phase addresses the routing problems in each sector: new Mixed Capacitated Arc Routing with Limited Multi-Landfills models will be presented. The last phase integrates Sectoring and Routing. Computational results confirm the effectiveness of the entire novel approach.
Resumo:
O tratamento das águas residuais domésticas surge com o intuito de degradar os poluentes presentes, para que as águas residuais tratadas não prejudiquem o ambiente nem a saúde pública. O presente trabalho teve como objetivo a conceção e o dimensionamento de uma Estação de Tratamento de Águas Residuais (ETAR) na freguesia de Canelas com a finalidade de substituir a já existente e permitir a ampliação da área da rede de saneamento da freguesia. Foram considerados dois tipos de ETAR’s, compacta e convencional, para tratar águas residuais domésticas de aproxidamente 2000 habitantes, com um caudal médio de 400 m3/dia e um caudal de ponta de 1136,7 m3/dia. Das duas opções optou-se pela convencional uma vez que acarreta um menor investimento, no valor de 187 232 €, e se considera também mais adequada às características do efluente a tratar. O tratamento escolhido inclui inicialmente uma gradagem, com uma grade constituída por sete barras com um espaçamento de 20 mm entre elas, seguida de um tamisador rotativo com uma abertura de malha de 3 mm. Depois do tamisador, optou-se por um sistema de desarenação/desengorduramento com um volume do tanque de 3,95 m3 e um fluxo de ar de 17,9 m3/h. Na fase seguinte considerou-se um tratamento biológico por lamas ativadas em regime de arejamento prolongado num tanque de arejamento de volume igual a 245,8 m3 com um arejador submerso, seguindo-se um decantador secundário de volume 33,3 m3. Por último, escolheu-se um sistema de desinfeção por ultravioleta e, a montante do mesmo, um filtro rápido para eliminar pequenas partículas que o efluente ainda possa conter. Para a desinfeção foram consideradas duas secções com cinco módulos de duas lâmpadas cada, ou seja, vinte lâmpadas ultravioleta. Dos resíduos produzidos pelo tratamento da água residual, os gradados e as areias serão encaminhados para aterro, enquanto que as lamas serão enviadas para a ETAR das Termas de S.Vicente, para que sofram o tratamento adequado e sejam encaminhadas para o destinal final adequado (aplicação em solos agrícolas, compostagem ou em alternativa para aterro). No caso da ETAR covencional foi ainda avaliada a possível reutilização de um decantador da ETAR de Milhundos uma vez que esta se encontrava em fase de desativação. Desta avaliação, concluiu-se que não seria economicamente viável o seu reaproveitamento. Mestrado em Engenharia Química – Tecnologias de Proteção Ambiental Para além disso realizou-se também um levantamento dos principais problemas que ocorrem na maioria das ETAR’s e foram apresentadas as respetivas sugestões de resolução. A realização de um inquérito permititu concluir que os odores são o problema que mais causa incómodo à população.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Química e Bioquímica
Resumo:
World in Progress, Soares da Costa Magazine, 2, Set., 2011
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Química e Bioquímica
Resumo:
Materials Science Forum Vols. 730-732 (2013) pp 617-622
Resumo:
The effects of swine wastewater-derived biogas on microalgae productivity were determined. Experiments were conducted in a closed photobioreactor containing digestate effluent as culturing media and biogas in the headspaceas source of CO2. Experiments were carried out under mixothrophic and autothrophic conditions. Results showed that autotrophic growth rate (0.6 d-1)was twofoldfaster than mixotrophic. Frequent reinjections of biogas containing up to 2,000 ppm of hydrogen sulfide was not inhibitory to microalgae growth. The rapid removal of H2S in the system suggests photobioreactors can be an interesting alternative to biogas purification. A model to estimate microalgae productivity based on the amount of available CO2, inorganic and organic carbon was developedand showed good data fit correlation (r²= 0.99).
Resumo:
The objective of the study was to report the first occurrence of the parasitoid Brachymeria podagrica in pupae of Ophyra aenescens, a fly of medical-sanitary importance. Human feces was used as bait to collect the insects. In the study 20 pupae of Ophyra aenescens (Wiedemann) (Diptera: Muscidae) were obtained, of which 20% of the total yielded the parasitoid Brachymeria podagrica (Hymenoptera: Chalcididae).