977 resultados para nuclear resonance, medical diagnostic, lung


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The aim of this study was to investigate bone changes in the condyle, articular eminence and glenoid fossa in relation to the position of the articular disc. Methods: 148 temporomandibular joints (TMJs) of 74 symptomatic patients who underwent MRI were evaluated. The position of the disc was classified as either normal (N), disc displacement with reduction (DDwR), disc displacement without reduction (DDwoR) and posterior displacement (PD). Bone changes were investigated in the condyle and temporal components of the TMJ and classified as osteophytosis, sclerosis or erosion. Results: There were no bone changes in the glenoid fossa of the temporal bone. Of the total number of TMJs studied, 94 (63.5%) were N, 34 (23%) presented DDwoR, 19 (12.8%) presented DDwR and 1 (0.7%) presented PD. The bone changes in the condyle and posterior aspect of the articular eminence were associated with the position of the disc. The bone changes in the anterior aspect of the articular eminence were not associated with the position of the disc. Conclusion: In cases of DDwoR, bone changes in the condyles were more common. The combination of erosion and osteophytosis in the condyle and the bone changes of the posterior aspect of the articular eminence were associated with disc position. Dentomaxillofacial Radiology (2012) 41, 367-372. doi: 10.1259/dmfr/79317853

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE. The objective of our study was to evaluate the effectiveness of MRI in the detection of possible residual lesions after radiofrequency ablation (RFA) in the treatment of breast cancer. SUBJECTS AND METHODS. We prospectively evaluated 14 patients who had undergone ultrasound-guided core biopsies diagnostic of invasive ductal carcinoma (IDC; range of diameters, 1.0-3.0 cm) and then ultrasound-guided percutaneous RFA with sentinel node biopsy as the primary treatment. Breast MRI was performed 1 week before RFA to evaluate tumor extension and again 3 weeks after RFA to verify the presence of possible residual lesions. Conventional surgical resection of the tumors was performed 1 week after RFA. The MRI findings were compared with histopathologic analyses to confirm the presence or absence of residual tumor. RESULTS. There was no residual enhancement in seven lesions on the postablation breast MRI scans. These findings were confirmed by negative histopathologic findings in the surgical specimens. The MRI scans of five patients showed small areas of irregular enhancement that corresponded to residual lesions. In the two remaining patients, we observed enhancement of almost the entire lesion, indicating that RFA had failed. CONCLUSION. Breast MRI is effective in detecting residual lesions after RFA in patients with IDC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The purpose of this study was to analyse the use of digital tools for image enhancement of mandibular radiolucent lesions and the effects of this manipulation on the percentage of correct radiographic diagnoses. Methods: 24 panoramic radiographs exhibiting radiolucent lesions were selected, digitized and evaluated by non-experts (undergraduate and newly graduated practitioners) and by professional experts in oral diagnosis. The percentages of correct and incorrect diagnoses, according to the use of brightness/contrast, sharpness, inversion, highlight and zoom tools, were compared. All dental professionals made their evaluations without (T-1) and with (T-2) a list of radiographic diagnostic parameters. Results: Digital tools were used with low frequency mainly in T-2. The most preferred tool was sharpness (45.2%). In the expert group, the percentage of correct diagnoses did not change when any of the digital tools were used. For the non-expert group, there was an increase in the frequency of correct diagnoses when brightness/contrast was used in T-2 (p = 0.008) and when brightness/contrast and sharpness were not used in T-1 (p = 0.027). The use or non-use of brightness/contrast, zoom and sharpness showed moderate agreement in the group of experts [kappa agreement coefficient (kappa) = 0.514, 0.425 and 0.335, respectively]. For the non-expert group there was slight agreement for all the tools used (kappa <= 0.237). Conclusions: Consulting the list of radiographic parameters before image manipulation reduced the frequency of tool use in both groups of examiners. Consulting the radiographic parameters with the use of some digital tools was important for improving correct diagnosis only in the group of non-expert examiners. Dentomaxillofacial Radiology (2012) 41, 203-210. doi: 10.1259/dmfr/78567773

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A computational pipeline combining texture analysis and pattern classification algorithms was developed for investigating associations between high-resolution MRI features and histological data. This methodology was tested in the study of dentate gyrus images of sclerotic hippocampi resected from refractory epilepsy patients. Images were acquired using a simple surface coil in a 3.0T MRI scanner. All specimens were subsequently submitted to histological semiquantitative evaluation. The computational pipeline was applied for classifying pixels according to: a) dentate gyrus histological parameters and b) patients' febrile or afebrile initial precipitating insult history. The pipeline results for febrile and afebrile patients achieved 70% classification accuracy, with 78% sensitivity and 80% specificity [area under the reader observer characteristics (ROC) curve: 0.89]. The analysis of the histological data alone was not sufficient to achieve significant power to separate febrile and afebrile groups. Interesting enough, the results from our approach did not show significant correlation with histological parameters (which per se were not enough to classify patient groups). These results showed the potential of adding computational texture analysis together with classification methods for detecting subtle MRI signal differences, a method sufficient to provide good clinical classification. A wide range of applications of this pipeline can also be used in other areas of medical imaging. Magn Reson Med, 2012. (c) 2012 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective Severe pulmonary hypoplasia and pulmonary arterial hypertension are associated with reduced survival in congenital diaphragmatic hernia (CDH). We aimed to determine whether fetal endoscopic tracheal occlusion (FETO) improves survival in cases of severe isolated CDH. Methods Between May 2008 and July 2010, patients whose fetuses had severe isolated CDH (lung-to-head ratio < 1.0, liver herniation into the thoracic cavity and no other detectable anomalies) were assigned randomly to FETO or to no fetal intervention (controls). FETO was performed under maternal epidural anesthesia supplemented with fetal intramuscular anesthesia. Tracheal balloon placement was achieved with ultrasound guidance and fetoscopy between 26 and 30 weeks of gestation. All cases that underwent FETO were delivered by the EXIT procedure. Postnatal therapy was the same for both treated fetuses and controls. The primary outcome was survival to 6 months of age. Other maternal and neonatal outcomes were also evaluated. Results Twenty patients were enrolled randomly to FETO and 21 patients to standard postnatal management. The mean gestational age at randomization was similar in both groups (P = 0.83). Delivery occurred at 35.6 +/- 2.4 weeks in the FETO group and at 37.4 +/- 1.9 weeks in the controls (P < 0.01). In the intention-to-treat analysis, 10/20 (50.0%) infants in the FETO group survived, while 1/21 (4.8%) controls survived (relative risk (RR), 10.5 (95% CI, 1.5-74.7), P < 0.01). In the receivedtreatment analysis, 10/19 (52.6%) infants in the FETO group and 1/19 (5.3%) controls survived (RR, 10.0 (95% CI, 1.4-70.6) P < 0.01). Conclusion FETO improves neonatal survival in cases with isolated severe CDH. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives To evaluate the accuracy and probabilities of different fetal ultrasound parameters to predict neonatal outcome in isolated congenital diaphragmatic hernia (CDH). Methods Between January 2004 and December 2010, we evaluated prospectively 108 fetuses with isolated CDH (82 left-sided and 26 right-sided). The following parameters were evaluated: gestational age at diagnosis, side of the diaphragmatic defect, presence of polyhydramnios, presence of liver herniated into the fetal thorax (liver-up), lung-to-head ratio (LHR) and observed/expected LHR (o/e-LHR), observed/expected contralateral and total fetal lung volume (o/e-ContFLV and o/e-TotFLV) ratios, ultrasonographic fetal lung volume/fetal weight ratio (US-FLW), observed/expected contralateral and main pulmonary artery diameter (o/e-ContPA and o/eMPA) ratios and the contralateral vascularization index (Cont-VI). The outcomes were neonatal death and severe postnatal pulmonary arterial hypertension (PAH). Results Neonatal mortality was 64.8% (70/108). Severe PAH was diagnosed in 68 (63.0%) cases, of which 63 died neonatally (92.6%) (P < 0.001). Gestational age at diagnosis, side of the defect and polyhydramnios were not associated with poor outcome (P > 0.05). LHR, o/eLHR, liver-up, o/e-ContFLV, o/e-TotFLV, US-FLW, o/eContPA, o/e-MPA and Cont-VI were associated with both neonatal death and severe postnatal PAH (P < 0.001). Receiver-operating characteristics curves indicated that measuring total lung volumes (o/e-TotFLV and US-FLW) was more accurate than was considering only the contralateral lung sizes (LHR, o/e-LHR and o/e-ContFLV; P < 0.05), and Cont-VI was the most accurate ultrasound parameter to predict neonatal death and severe PAH (P < 0.001). Conclusions Evaluating total lung volumes is more accurate than is measuring only the contralateral lung size. Evaluating pulmonary vascularization (Cont-VI) is the most accurate predictor of neonatal outcome. Estimating the probability of survival and severe PAH allows classification of cases according to prognosis. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE To report on our clinical experience with and the success rate and safety of percutaneous transcatheter embolization with N-butyl cyanoacrylate (NBCA) as the lone primary embolic agent used for arterial embolization of hemorrhagic liver lesions. MATERIALS AND METHODS This retrospective study enrolled all patients who presented to the emergency room with hemorrhagic liver lesions during a two-year period and were treated by percutaneous transcatheter embolization with NBCA. RESULTS Eight consecutive patients were evaluated, and 13 lesions were embolized exclusively with NBCA: eight pseudoaneurysms and five active bleeds. All patients were treated successfully using percutaneous transcatheter embolization with NBCA without re-bleedings or major complications. CONCLUSION Percutaneous transcatheter embolization with NBCA is a safe and effective method for treating hemorrhagic lesions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract Background Despite new brain imaging techniques that have improved the study of the underlying processes of human decision-making, to the best of our knowledge, there have been very few studies that have attempted to investigate brain activity during medical diagnostic processing. We investigated brain electroencephalography (EEG) activity associated with diagnostic decision-making in the realm of veterinary medicine using X-rays as a fundamental auxiliary test. EEG signals were analysed using Principal Components (PCA) and Logistic Regression Analysis Results The principal component analysis revealed three patterns that accounted for 85% of the total variance in the EEG activity recorded while veterinary doctors read a clinical history, examined an X-ray image pertinent to a medical case, and selected among alternative diagnostic hypotheses. Two of these patterns are proposed to be associated with visual processing and the executive control of the task. The other two patterns are proposed to be related to the reasoning process that occurs during diagnostic decision-making. Conclusions PCA analysis was successful in disclosing the different patterns of brain activity associated with hypothesis triggering and handling (pattern P1); identification uncertainty and prevalence assessment (pattern P3), and hypothesis plausibility calculation (pattern P2); Logistic regression analysis was successful in disclosing the brain activity associated with clinical reasoning success, and together with regression analysis showed that clinical practice reorganizes the neural circuits supporting clinical reasoning.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Im Rahmen dieser Arbeit wurde ein neuartiger Experimentaufbau -- das γ3 Experiment -- zur Messung von photoneninduzierten Kern-Dipolanregungen in stabilen Isotopen konzipiert und an der High Intensity γ-Ray Source (HIγS) an der Duke University installiert.rnDie hohe Energieauflösung und die hohe Nachweiseffizienz des Detektoraufbaus, welcher aus einer Kombination von LaBr Szintillatoren und hochreinen Germanium-Detektoren besteht, erlaubt erstmals die effiziente Messung von γ-γ-Koinzidenzen in Verbindung mit der Methode der Kernresonanzfluoreszenz.rnDiese Methode eröffnet den Zugang zum Zerfallsverhalten der angeregten Dipolzustände als zusätzlicher Observablen, die ein detaillierteres Verständnis der zugrunde liegenden Struktur dieser Anregungen ermöglicht.rnDer Detektoraufbau wurde bereits erfolgreich im Rahmen von zwei Experimentkampagnen in 2012 und 2013 für die Untersuchung von 13 verschiedenen Isotopen verwendet. Im Fokus dieser Arbeit stand die Analyse der Pygmy-Dipolresonanz (PDR) im Kern 140Ce im Energiebereich von 5,2 MeV bis 8,3 MeV basierend auf den mit dem γ3 Experimentaufbau gemessenen Daten. Insbesondere das Zerfallsverhalten der Zustände, die an der PDR beteiligt sind, wurde untersucht. Der Experimentaufbau, die Details der Analyse sowie die Resultate werden in der vorliegenden Arbeit präsentiert. Desweiteren erlaubt ein Vergleich der Ergebnisse mit theoretischen Rechnungen im quasi-particle phonon model (QPM) eine Interpretation des beobachteten Zerfallsverhaltens.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: We report mid-term results after 25 consecutive lung volume reduction operations (LVRS) for the treatment of severe dyspnea due to advanced emphysema. METHODS: Study design: patients were studied prospectively up to 12 months after surgery. Setting: preoperative evaluation, surgery and postoperative care took place in our university hospital. Patients: patient selection was based on severe dyspnea and airway obstruction despite optimal medical treatment, lung overinflation and completed rehabilitation programme. Patients with severe hypercarbia (PCO2>50 mmHg) were excluded. Nineteen rehabilitated patients who fulfilled our inclusion criteria but postponed or denied LVRS were followed up clinically. Interventions: LVRS was performed bilaterally in 22 patients (median sternotomy) and unilaterally in 3 patients (limited thoracotomy). Measures: Outcome was measured by dyspnea evaluation, 6-minute-walking distance and pulmonary function tests. RESULTS: Twelve months postoperatively dyspnea and mobility improved significantly (MRC score from 3.3+/-0.7 to 2.12+/-0.8, 6-min-walk from 251+/-190 to 477+/-189 m). These results were superior compared to the results of the conservatively treated patients. Significant improvement could also be documented in airway obstruction (FEV1 from 960+/-369 to 1438+/-610 ml) and overinflation (TLC from 133+/-14 to 118+/-21% predicted and RV from 280+/-56 to 186+/-59% predicted). CONCLUSIONS: LVRS is an effective and promising treatment option for selected patients with end-stage emphysema and could be offered as an alternative and / or bridge to lung transplantation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The influence of respiratory motion on patient anatomy poses a challenge to accurate radiation therapy, especially in lung cancer treatment. Modern radiation therapy planning uses models of tumor respiratory motion to account for target motion in targeting. The tumor motion model can be verified on a per-treatment session basis with four-dimensional cone-beam computed tomography (4D-CBCT), which acquires an image set of the dynamic target throughout the respiratory cycle during the therapy session. 4D-CBCT is undersampled if the scan time is too short. However, short scan time is desirable in clinical practice to reduce patient setup time. This dissertation presents the design and optimization of 4D-CBCT to reduce the impact of undersampling artifacts with short scan times. This work measures the impact of undersampling artifacts on the accuracy of target motion measurement under different sampling conditions and for various object sizes and motions. The results provide a minimum scan time such that the target tracking error is less than a specified tolerance. This work also presents new image reconstruction algorithms for reducing undersampling artifacts in undersampled datasets by taking advantage of the assumption that the relevant motion of interest is contained within a volume-of-interest (VOI). It is shown that the VOI-based reconstruction provides more accurate image intensity than standard reconstruction. The VOI-based reconstruction produced 43% fewer least-squares error inside the VOI and 84% fewer error throughout the image in a study designed to simulate target motion. The VOI-based reconstruction approach can reduce acquisition time and improve image quality in 4D-CBCT.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"Contract No. AT(40-1)-Gen-33."

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rationale and Objectives. The authors attempt to provide a set of objectives for medical student training in radiology for contemporary medical practice. Materials and Methods. A questionnaire containing a list of educational objectives was sent to 32 radiologists in charge of medical student training in radiology at accredited residency programs in Australia and New Zealand. The importance of including each preselected objective in the curriculum was measured by respondents' agreement or disagreement on a scale of 1-6. Opportunity also was given to respondents to suggest objectives other than those presented on the questionnaire. Results. Twenty of the 32 questionnaires were returned, and a set of educational objectives was established based on the responses. The objectives were ranked in importance according to the mean score assigned to each objective by the respondents. Conclusion. This new set of educational objectives for medical student radiology training reflects recent changes in radiologic and medical practice and points to potential future developments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recently, a 3D phantom that can provide a comprehensive and accurate measurement of the geometric distortion in MRI has been developed. Using this phantom, a full assessment of the geometric distortion in a number of clinical MRI systems (GE and Siemens) has been carried out and detailed results are presented in this paper. As expected, the main source of geometric distortion in modern superconducting MRI systems arises from the gradient field nonlinearity. Significantly large distortions with maximum absolute geometric errors ranged between 10 and 25 mm within a volume of 240 x 240 x 240 mm(3) were observed when imaging with the new generation of gradient systems that employs shorter coils. By comparison, the geometric distortion was much less in the older-generation gradient systems. With the vendor's correction method, the geometric distortion measured was significantly reduced but only within the plane in which these 2D correction methods were applied. Distortion along the axis normal to the plane was, as expected, virtually unchanged. Two-dimensional correction methods are a convenient approach and in principle they are the only methods that can be applied to correct geometric distortion in a single slice or in multiple noncontiguous slices. However, these methods only provide an incomplete solution to the problem and their value can be significantly reduced if the distortion along the normal of the correction plane is not small. (C) 2004 Elsevier Inc. All rights reserved.