957 resultados para non-destructive test
Resumo:
Nowadays there is great interest in structural damage detection in systems using nondestructive tests. Once the failure is detected, as for instance a crack, it is possible to take providences. There are several different approaches that can be used to obtain information about the existence, location and extension of the fault in the system by non-destructive tests. Among these methodologies, one can mention different optimization techniques, as for instance classical methods, genetic algorithms, neural networks, etc. Most of these techniques, which are based on element-byelement adjustments of a finite element (FE) model, take advantage of the dynamic behavior of the model. However, in practical situations, usually, is almost impossible to obtain an accuracy model. In this paper, it is proposed an experimental technique for damage location. This technique is based on H: norm to obtain the damage location. The dynamic properties of the structure were identified using experimental data by eigensystem realization algorithm (ERA). The experimental test was carried out in a beam structure through varying the mass of an element. For the output signal was used a piezoelectric sensor. The signal of input of sine form was generated through SignalCalc® software.
Resumo:
The goal of this research was to determine the density distribution in medium density fiberboard (MDF), manufactured with polyurethane derived from castor oil using, ultrasonic wave technique. The equipment used in this test is Steinkamp BP7 with plan and exponential transducers, both with 45 kHz frequencies, located in several zones on the plate in order to determine wave ultrasonic velocity. The Pinus caribaea and Eucalyptus grandis fiberboard were manufactured in the quality control and products development laboratory of Duratex with 500 mm long, 500 mm large, 8 and 15 mm of thickness. Three MDF for each fiber specimen and thickness were fabricated, totalizing twelve plates tested. The MDF were produced with 5% polyurethane addition, in temperature of 160°C, tension press of 53 bars and addition of moisture content of 12%. For determination of fiberboard density, samples were extracted from the same zones where the wave ultrasonic velocity was determined. In this case, DAX-Ray equipment was used. Statistical analysis shows good agreement with wave ultrasonic velocity and the density profile, validating the application of non-destructive technique in order to determine the density profile of MDF's.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The paper describes the preliminary studies of University of Minho on the use of Electric Impedance/Resistance Tomography to assess masonry structures. The study is focused on the analysis of values of current and voltage resulting from the use of an electrical source with voltage and frequency values from a distribution network. The analysis is made from results obtained through computer simulations, using a three-dimensional model of the idealized masonry structures. A finite element program was used for the simulations. Three types of electrodes were used in simulations, and the analysis of the results led to significant conclusions. Later masonry specimens were built and a series of preliminary tests were carried out in the laboratory. The comparative analysis of simulated and experimental results allowed identifying the factors that have influence on the physical results.
Resumo:
2,25Cr-1Mo alloy steels are widely used in petrochemical plant equipments working in high temperature conditions because of their good mechanical proprieties in these conditions. Although, when exposed for a long time at high temperature, in the rage of 343 °C to 593 °C, may present the temper embrittlement phenomenon. The component named stripper of assembly converter of fluid catalytic cracking unit (UFCC) of studied plant is manufactured using this material, which is subject to temper embrittlement. The phenomenon of temper embrittlement refers to progressive lose of toughness, making the material brittle. With embrittlement, equipaments manufactured with this material are under risks to suffer brittle fracture in the cool down and start-up situations of them, which can cause catastrophic failures. By this reason, this research studies presence of temper ebrittlement phenomenon on this material. To verify the toughness of the material is conventionally used charpy V-notch test. However, this test requires the removing of samples of the material to make specimens. This fact becomes critical when talk about structural components of an equipment. So, this research also studies a non-destructive test that can be executes in-situ, known as instrumented indentation, as an alternative detection of the phenomenon at the component stripper, by comparative of the mechanical proprieties obtained by conventional tests in similar samples
Resumo:
Es sollen hochfeste, gewichtreduzierte Zug- und Tragmittel aus hochmodularen (HM) und hochfesten (HT) Fasern validiert und dabei sowohl runde als auch flache, riemenartige Strukturen untersucht werden. Dadurch sind effizientere Fördersysteme und die Überwindung technischer Grenzen möglich. Darüber hinaus soll das Hauptkriterium für ein breites Anwendungsspektrum geschaffen werden: ein anerkanntes, zerstörungsfreies Prüfverfahren, mit dem der Austausch- bzw. Wartungszeitpunkt des textilen Tragmittels bestimmt werden kann. Können die o. g. Punkte erfolgreich bearbeitet werden, erfolgt eine Ausdehnung der textilen Strukturen in den Bereich kraftübertragender Maschinenelemente. Anhand von Feldversuchen in fördertechnischen Anlagen im Bergbau/ Intralogistik soll erstmals der vollständige Nachweis geführt werden, dass derartige textile Strukturen in technischen Anwendungen eingesetzt werden können. Der Nachweis umfasst die Validierung einer Vielzahl von Einzelschwerpunkten wie die Entwicklung einer Endlos-Herstellungstechnologie bzw. Endverbindung, die Tragmitteldimensionierung, die Erbringung von Festigkeitsnachweisen, die Erarbeitung von Vorschriften und die Erprobung der Verfahren zur Zustandsüberwachung.
Resumo:
La termografía es un método de inspección y diagnóstico basado en la radiación infrarroja que emiten los cuerpos. Permite medir dicha radiación a distancia y sin contacto, obteniendo un termograma o imagen termográfica, objeto de estudio de este proyecto. Todos los cuerpos que se encuentren a una cierta temperatura emiten radiación infrarroja. Sin embargo, para hacer una inspección termográfica hay que tener en cuenta la emisividad de los cuerpos, capacidad que tienen de emitir radiación, ya que ésta no sólo depende de la temperatura del cuerpo, sino también de sus características superficiales. Las herramientas necesarias para conseguir un termograma son principalmente una cámara termográfica y un software que permita su análisis. La cámara percibe la emisión infrarroja de un objeto y lo convierte en una imagen visible, originalmente monocromática. Sin embargo, después es coloreada por la propia cámara o por un software para una interpretación más fácil del termograma. Para obtener estas imágenes termográficas existen varias técnicas, que se diferencian en cómo la energía calorífica se transfiere al cuerpo. Estas técnicas se clasifican en termografía pasiva, activa y vibrotermografía. El método que se utiliza en cada caso depende de las características térmicas del cuerpo, del tipo de defecto a localizar o la resolución espacial de las imágenes, entre otros factores. Para analizar las imágenes y así obtener diagnósticos y detectar defectos, es importante la precisión. Por ello existe un procesado de las imágenes, para minimizar los efectos provocados por causas externas, mejorar la calidad de la imagen y extraer información de las inspecciones realizadas. La termografía es un método de ensayo no destructivo muy flexible y que ofrece muchas ventajas. Por esta razón el campo de aplicación es muy amplio, abarcando desde aplicaciones industriales hasta investigación y desarrollo. Vigilancia y seguridad, ahorro energético, medicina o medio ambiente, son algunos de los campos donde la termografía aportaimportantes beneficios. Este proyecto es un estudio teórico de la termografía, donde se describen detalladamente cada uno de los aspectos mencionados. Concluye con una aplicación práctica, creando una cámara infrarroja a partir de una webcam, y realizando un análisis de las imágenes obtenidas con ella. Con esto se demuestran algunas de las teorías explicadas, así como la posibilidad de reconocer objetos mediante la termografía. Thermography is a method of testing and diagnosis based on the infrared radiation emitted by bodies. It allows to measure this radiation from a distance and with no contact, getting a thermogram or thermal image, object of study of this project. All bodies that are at a certain temperature emit infrared radiation. However, making a thermographic inspection must take into account the emissivity of the body, capability of emitting radiation. This not only depends on the temperature of the body, but also on its surface characteristics. The tools needed to get a thermogram are mainly a thermal imaging camera and software that allows analysis. The camera sees the infrared emission of an object and converts it into a visible image, originally monochrome. However, after it is colored by the camera or software for easier interpretation of thermogram. To obtain these thermal images it exists various techniques, which differ in how heat energy is transferred to the body. These techniques are classified into passive thermography, active and vibrotermografy. The method used in each case depends on the thermal characteristics of the body, the type of defect to locate or spatial resolution of images, among other factors. To analyze the images and obtain diagnoses and defects, accuracy is important. Thus there is a image processing to minimize the effects caused by external causes, improving image quality and extract information from inspections. Thermography is a non-‐destructive test method very flexible and offers many advantages. So the scope is very wide, ranging from industrial applications to research and development.Surveillance and security, energy saving, environmental or medicine are some of the areas where thermography provides significant benefits. This project is a theoretical study of thermography, which describes in detail each of these aspects. It concludes with a practical application, creating an infrared camera from a webcam, and making an analysis of the images obtained with it. This will demonstrate some of the theories explained as well as the ability to recognize objects by thermography.
Resumo:
International audience
Resumo:
The near infrared (NIR) spectroscopy presents itself as an interesting non-destructive test tool as it enables a fast, simple and reliable way for characterizing large samplings of biological materials in a short period of time. This work aimed to establish multivariate models to estimate the crystallinity indices and tensile and burst strength of cellulosic and nanocellulosic films through NIR spectroscopy. NIR spectra were recorded from the films before tensile and bursting strength, and crystallinity tests. Spectral information were correlated with reference values obtained by laboratory procedures through partial least square regression (PLS-R). The PLS-R model for estimating the crystallinity index presented a coefficient of determination in cross-validation (R2cv) of 0,94 and the ratio of performance to deviation (RPD) was 3,77. The mechanical properties of the films presented a high correlation with the NIR spectra: R2p = 0,85 (RPD = 2,23) for tensile and R2p = 0,93 (RPD = 3,40) for burst strength. The statistics associated to the models presented have shown that the NIR spectroscopy has the potential to estimate the crystallinity index and resistance properties of cellulose and nanocellulose films on in-line monitoring systems.
Resumo:
In order to widely use Ge and III-V materials instead of Si in advanced CMOS technology, the process and integration of these materials has to be well established so that their high mobility benefit is not swamped by imperfect manufacturing procedures. In this dissertation number of key bottlenecks in realization of Ge devices are investigated; We address the challenge of the formation of low resistivity contacts on n-type Ge, comparing conventional and advanced rapid thermal annealing (RTA) and laser thermal annealing (LTA) techniques respectively. LTA appears to be a feasible approach for realization of low resistivity contacts with an incredibly sharp germanide-substrate interface and contact resistivity in the order of 10 -7 Ω.cm2. Furthermore the influence of RTA and LTA on dopant activation and leakage current suppression in n+/p Ge junction were compared. Providing very high active carrier concentration > 1020 cm-3, LTA resulted in higher leakage current compared to RTA which provided lower carrier concentration ~1019 cm-3. This is an indication of a trade-off between high activation level and junction leakage current. High ION/IOFF ratio ~ 107 was obtained, which to the best of our knowledge is the best reported value for n-type Ge so far. Simulations were carried out to investigate how target sputtering, dose retention, and damage formation is generated in thin-body semiconductors by means of energetic ion impacts and how they are dependent on the target physical material properties. Solid phase epitaxy studies in wide and thin Ge fins confirmed the formation of twin boundary defects and random nucleation growth, like in Si, but here 600 °C annealing temperature was found to be effective to reduce these defects. Finally, a non-destructive doping technique was successfully implemented to dope Ge nanowires, where nanowire resistivity was reduced by 5 orders of magnitude using PH3 based in-diffusion process.
Resumo:
The non-destructive evaluation of the water permeability of concrete structures is a long standing challenge, principally due to the difficulty of achieving a uni-direction flow for computing the water permeability coefficient. The use of a guard ring (GR) was originally proposed for the in situ sorptivity test, but little information can be found for the water permeability test. In this study, the effect of a GR was carefully examined through the flow simulation, which was verified by carrying out experiments. It was observed that the GR can confine the flow near the surface, but cannot achieve a uni-directional flow across the whole depth of flow. To achieve a better performance, it is essential to consider the effects of the size of the inner seal and the GR and the significant interaction between these two. The analysis of the experimental data has indicated that the GR influences the flow for porous concretes, but there is no significant effect for dense concretes. Further investigation, validated using the flow-net theory, has shown a strong correlation between the water permeability coefficients obtained with the GR (K w-GR) and without it (K w-No GR), suggesting that one dimensional flow is not essential for interpreting data for site tests. Another practical issue was that more than 30 % of the tests with GR failed due to the difficulty of achieving a good seal between the inner and the outer chambers. Based on the work reported in this paper, a new water permeability test is proposed.
Resumo:
Currently there is no reliable objective method to quantify the setting properties of acrylic bone cements within an operating theatre environment. Ultrasonic technology can be used to determine the acoustic properties of the polymerising bone cement, which are linked to material properties and provide indications of the physical and chemical changes occurring within the cement. The focus of this study was the critical evaluation of pulse-echo ultrasonic test method in determining the setting and mechanical properties of three different acrylic bone cement when prepared under atmospheric and vacuum mixing conditions. Results indicated that the ultrasonic pulse-echo technique provided a highly reproducible and accurate method of monitoring the polymerisation reaction and indicating the principal setting parameters when compared to ISO 5833 standard, irrespective of the acrylic bone cement or mixing method used. However, applying the same test method to predict the final mechanical properties of acrylic bone cement did not prove a wholly accurate approach. Inhomogeneities within the cement microstructure and specimen geometry were found to have a significant influence on mechanical property predictions. Consideration of all the results suggests that the non-invasive and non-destructive pulse-echo ultrasonic test method is an effective and reliable method for following the full polymerisation reaction of acrylic bone cement in real-time and then determining the setting properties within a surgical theatre environment. However the application of similar technology for predicting the final mechanical properties of acrylic bone cement on a consistent basis may prove difficult.