165 resultados para microclimate
Resumo:
We report on a revisit in 2009 to sites where vegetation was recorded in 1967 and 1970 on Disko Island, West Greenland. Re-sampling of the same clones of the grass Phleum alpinum after 39 years showed complete stability in biometrics but dramatic earlier onset of various phenological stages that were not related to changes in population density. In a fell-field community, there was a net species loss, but in a herb-slope community, species losses balanced those that were gained. The type of species establishing and increasing in frequency and/or cover abundance at the fell-field site, particularly prostrate dwarf shrubs, indicates a possible start of a shift towards a heath, rather than a fell-field community. At the herb-slope site, those species that established or increased markedly in frequency and/or cover abundance indicate a change to drier conditions. This is confirmed both by the decrease in abundance of Alchemilla glomerulans and Epilobium hornemanii, and the drying of a nearby pond. The causes of these changes are unknown, although mean annual temperature has risen since 1984.
Resumo:
Passive chambers are used to examine the impacts of summer warming in Antarctica but, so far, impacts occurring outside the growing season, or related to extreme temperatures, have not been reported, despite their potentially large biological significance. In this review, we synthesise and discuss the microclimate impacts of passive warming chambers (closed, ventilated and Open Top Chamber-OTC) commonly used in Antarctic terrestrial habitats, paying special attention to seasonal warming, during the growing season and outside, extreme temperatures and freeze-thaw events. Both temperature increases and decreases were recorded throughout the year. Closed chambers caused earlier spring soil thaw (8-28 days) while OTCs delayed soil thaw (3-13 days). Smaller closed chamber types recorded the largest temperature extremes (up to 20°C higher than ambient) and longest periods (up to 11 h) of above ambient extreme temperatures, and even OTCs had above ambient temperature extremes over up to 5 consecutive hours. The frequency of freeze-thaw events was reduced by ~25%. All chamber types experienced extreme temperature ranges that could negatively affect biological responses, while warming during winter could result in depletion of limited metabolic resources. The effects outside the growing season could be as important in driving biological responses as the mean summer warming. We make suggestions for improving season-specific warming simulations and propose that seasonal and changed temperature patterns achieved under climate manipulations should be recognised explicitly in descriptions of treatment effects.
Resumo:
The moist evergreen Afromontane forest of SW Ethiopia has become extremely fragmented and most remnants are intensively managed for cultivation of coffee (Coffea arabica). We investigated the distributions of epiphytic orchids in shade trees and their understory in forests with contrasting management intensity to determine biodiversity losses associated with coffee cultivation and to determine the capacity of coffee shrubs to act as refugia for orchid species. We studied epiphytic orchids in managed forests and natural forests and recorded orchid diversity and abundance in different tree zones of 339 trees and in the understory. Coffee management was associated with a downward shift of orchid species as orchid species were occurring in significantly lower tree zones in managed forest. The number of shrubs in the understory of managed forest was not higher than in natural forests, yet orchid abundance was higher in the understory of managed forests. Local extinctions of epiphytic orchids and species losses in the outer tree zones (a contraction of habitat) in managed forests are most likely driven by losses of large, complex-structured climax trees, and changes in microclimate, respectively. Coffee shrubs and their shade trees in managed forests are shown here to be a suitable habitat for only a limited set of orchid species. As farmers continue to convert natural forest into managed forest for coffee cultivation, further losses of habitat quality and collateral declines in regional epiphytic orchid diversity can be expected. Therefore, the conservation of epiphytic orchid diversity, as well as other components of diversity of the coffee forests, must primarily rely on avoiding coffee management intensification in the remaining natural forest. Convincing farmers to keep forest-climax trees in their coffee forest and to tolerate orchids on their coffee shrubs may also contribute to a more favorable conservation status of orchids in Ethiopian coffee agroecosystems.
Resumo:
La presente investigación parte del problema en las zonas de clima cálido - húmedo en las cuales se producen impactos asociados a la incomodidad térmica producto de la intensa radiación solar, altas temperaturas y elevada humedad. Estos factores reducen la calidad de los espacios abiertos y desarrollan en la población una actitud de rechazo hacia el uso del microespacio urbano entre edificaciones en los desarrollos urbanos - conjuntos urbanos - , los mismos frecuentemente admiten soluciones que al parecer no contribuyen a la realización de las actividades comunes de esparcimiento de la población residente. Por lo tanto, el objetivo de la investigación es profundizar en la temática urbano - ambiental - social y el diseño urbano vinculada a la particularidad morfológica local, las condiciones microclimáticas, el uso del microespacio y los requerimientos de los usuarios. La finalidad de desarrollar estrategias de control microclimático del microespacio entre edificios en clima cálido - húmedo en búsqueda de soluciones óptimas que satisfagan las necesidades de los usuarios de los espacios exteriores en estas áreas residenciales. La investigación se centra en el estudio de las particularidades contextuales relacionadas con el microclima y las características urbanas - morfotipológicas, básicamente los factores microclimáticos (soleamiento y ventilación), los morfológicos y edificatorios y las características de las superficies (pavimentos). En coherencia con el objetivo propuesto el trabajo se desarrolla en cuatro fases: la primera aborda la revisión documental, literatura relevante e investigaciones relativas a la calidad ambiental, medio social, medio físico, el microespacio urbano, control y diseño sostenible, modelización proyectual y estrategias sostenibles; la segunda fase se refiere al marco contextual, características urbanas, datos climáticos locales, planes y procesos urbanos, tipologías y conformación urbana. En esta fase se describe el proceso de selección, análisis y evaluación urbano - ambiental de los casos de estudio (conjuntos residenciales). En la tercera fase se aborda el marco evaluativo y estudio de casos, consideraciones físicas, climáticas y valoración térmico - ambiental de los conjuntos residenciales seleccionados. En esta fase se aplican Técnicas Estadísticas y de Simulación Computacional y se analizan los resultados obtenidos. Finalmente, la cuarta fase propositiva incluye el establecimiento de Estrategias, Principios y Lineamientos de optimación térmica y se exponen las Conclusiones parciales de la tesis, alcances y perspectivas futuras. Finalmente, los resultados obtenidos en la investigación demuestran que el análisis en las experiencias de la realidad permiten comprobar que las situaciones y alteraciones ambientales sustanciales, los niveles de afectación térmica y las condiciones de confortabilidad e impacto derivan de las características urbanas, los componentes del microespacio y de las condiciones climáticas las cuales afectan el desarrollo de las actividades y el uso efectivo del microespacio entre edificios. El análisis de los factores morfo - climáticos incidentes y el estudio de los efectos de interacción contribuyen al establecimiento de Principios y Lineamientos para la evaluación y diseño sostenible del microespacio entre edificios y el uso correcto de los elementos del clima en estas áreas urbanas destinadas a la actividad social y al esparcimiento de la población residente. ABSTRACT This research starts from the problem of hot - humid climate zones where impacts related to thermal discomfort are produced as a result from the intense solar radiation and high temperatures and humidity. These factors reduce the quality of open spaces and people develop an attitude of rejection towards the use of urban microspace among buildings within urban developments - urban complexes - . Usually, these complexes admit solutions that apparently do not contribute to the achievement of common leisure activities in the resident dwellers. Therefore, the main purpose of this research is to deepen in the urban - environmental - social issue and urban design linked to the local morphological particularity, microclimate conditions, use of microspace and users’ requirements. In order to develop microclimate control strategies of microspace among buildings in hot - humid climate to look for optimal solutions that satisfy users’ needs of outdoors spaces in these residential areas. The research focuses in the study of contextual particularities related to microclimate and urban - morphotypological characteristics. Basically, microclimate (sunlight and ventilation), morphological and building factors as well as road surface characteristics. According to the proposed objective, this research is developed in four phases: the first one considers documentary review, relevant literature and researches related to environmental quality, social environment, physical environment, urban microspace, control and sustainable design, project modelling and sustainable strategies; while the second phase refers to contextual framework, urban characteristics, local climate data, plans and urban processes, typologies and urban structure. In this phase, the process of selection, analysis and urban - environmental evaluation of case studies (residential complexes) is described. The third phase approaches the assessment framework and case studies, physical and climate considerations as well as environmental - thermal evaluation of selected residential complexes. In this phase, statistical techniques and computational simulations are applied. Likewise, results obtained are analysed. Similarly, fourth and proposing phase includes the establishment of strategies, principles and guidelines of thermal optimization and partial conclusions of the thesis, scopes and future perspectives are exposed. Finally, from the results obtained, it is demonstrated that the analysis on reality experiences allow proving that situations and substantial environmental changes, levels of thermal affectations, comfort conditions and impact derive from urban characteristics, microspace components and from climate conditions which affect the development of activities and the effective use of microspace among buildings. The analysis of incidental morpho - climate factors and the study of interaction effects contribute to the establishment of principles and guidelines for the assessment and sustainable design of microspace among buildings as well as the correct use of climate elements in these urban areas oriented to social and leisure activities of resident population.
Resumo:
El microclima urbano juega un rol importante en el consumo energético de los edificios y en las sensaciones de confort en los espacios exteriores. La urgente necesidad de aumentar la eficiencia energética, reducir las emisiones de los contaminantes y paliar la evidente falta de sostenibilidad que afecta a las ciudades, ha puesto la atención en el urbanismo bioclimático como referente para una propuesta de cambio en la forma de diseñar y vivir la ciudad. Hasta ahora las investigaciones en temas de microclima y eficiencia energética se han concentrado principalmente en como orientar el diseño de nuevos desarrollo. Sin embargo los principales problemas de la insostenibilidad de las actuales conurbaciones son el resultado del modelo de crecimiento especulativo y altamente agotador de recursos que han caracterizado el boom inmobiliario de las últimas décadas. Vemos entonces, tanto en España como en el resto de los Países Europeos, la necesidad de reorientar el sector de la construcción hacía la rehabilitación del espacio construido, como una alternativa capaz de dar una solución más sostenible para el mercado inmobiliario. En este propósito de mejorar la calidad de las ciudades actuales, el espacio público juega un papel fundamental, sobre todo como lugar para el encuentro y la socialización entre los ciudadanos. La sensación térmica condiciona la percepción de un ambiente, así que el microclima puede ser determinante para el éxito o el fracaso de un espacio urbano. Se plantea entonces cómo principal objetivo de la investigación, la definición de estrategias para el diseño bioclimático de los entornos urbanos construidos, fundamentados en las componentes morfotipológica, climática y de los requerimientos de confort para los ciudadanos. Como ulterior elemento de novedad se decide estudiar la rehabilitación de los barrios de construcción de mediado del siglo XX, que en muchos casos constituyen bolsas de degrado en la extendida periferia de las ciudades modernas. La metodología empleada para la investigación se basa en la evaluación de las condiciones climáticas y de confort térmico de diferentes escenarios de proyecto, aplicados a tres casos de estudio situados en un barrio periurbano de la ciudad de Madrid. Para la determinación de los parámetros climáticos se han empleado valores obtenidos con un proceso de simulación computarizada, basados en los principios de fluidodinámica, termodinámica y del intercambio radioactivo en el espacio construido. A través de uso de programas de simulación podemos hacer una previsión de las condiciones microclimáticas de las situaciones actuales y de los efectos de la aplicación de medidas. La gran ventaja en el uso de sistemas de cálculo es que se pueden evaluar diferentes escenarios de proyecto y elegir entre ellos el que asegura mejores prestaciones ambientales. Los resultados obtenidos en los diferentes escenarios han sido comparados con los valores de confort del estado actual, utilizando como indicador de la sensación térmica el índice UTCI. El análisis comparativo ha permitido la realización de una tabla de resumen donde se muestra la evaluación de las diferentes soluciones de rehabilitación. Se ha podido así demostrar que no existe una solución constructiva eficaz para todas las aplicaciones, sino que cada situación debe ser estudiada individualmente, aplicando caso por caso las medidas más oportunas. Si bien los sistemas de simulación computarizada pueden suponer un importante apoyo para la fase de diseño, es responsabilidad del proyectista emplear las herramientas más adecuadas en cada fase y elegir las soluciones más oportunas para cumplir con los objetivos del proyecto. The urban microclimate plays an important role on buildings energy consumption and comfort sensation in exterior spaces. Nowadays, cities need to increase energy efficiency, reduce the pollutants emissions and mitigate the evident lack of sustainability. In reason of this, attention has focused on the bioclimatic urbanism as a reference of change proposal of the way to design and live the city. Hitherto, the researches on microclimate and energy efficiency have mainly concentrated on guiding the design of new constructions. However the main problems of unsustainability of existing conurbations are the result of the growth model highly speculative and responsible of resources depletion that have characterized the real estate boom of recent decades. In Spain and other European countries, become define the need to redirect the construction sector towards urban refurbishment. This alternative is a more sustainable development model and is able to provide a solution for the real estate sector. In order to improve the quality of today's cities, the public space plays a key role, especially in order to provide to citizens places for meeting and socializing. The thermal sensation affects the environment perception, so microclimate conditions can be decisive for the success or failure of urban space. For this reasons, the main objective of this work is focused on the definition of bioclimatic strategies for existing urban spaces, based on the morpho-typological components, climate and comfort requirements for citizens. As novelty element, the regeneration of neighborhoods built in middle of the twentieth century has been studied, because are the major extended in periphery of modern cities and, in many cases, they represent deprived areas. The research methodology is based on the evaluation of climatic conditions and thermal comfort of different project scenarios, applied to three case studies located in a suburban neighborhood of Madrid. The climatic parameters have been obtained by computer simulation process, based on fluid dynamics, thermodynamics and radioactive exchange in urban environment using numerical approach. The great advantage in the use of computing systems is the capacity for evaluate different project scenarios. The results in the different scenarios were compared with the comfort value obtained in the current state, using the UTCI index as indicator of thermal sensation. Finally, an abacus of the thermal comfort improvement obtained by different countermeasures has been performed. One of the major achievement of doctoral work is the demonstration of there are not any design solution suitable for different cases. Each situation should be analyzed and specific design measures should be proposed. Computer simulation systems can be a significant support and help the designer in the decision making phase. However, the election of the most suitable tools and the appropriate solutions for each case is designer responsibility.
Resumo:
Debido a la complejidad de los procesos que controlan el intercambio de gases de carbono (C) y nitrógeno (N) entre el suelo y la atmósfera, en los sistemas forestales y agroforestales, son comprensibles las incógnitas existentes respecto a la estimación de los flujos de los gases de efecto invernadero (GEI) y la capacidad como reservorios de carbono de los suelos, bajo diferentes formas de uso y regímenes de alteración a escala regional y global. Esta escasez de información justifica la necesidad de caracterizar la dinámica de intercambio de GEI en los ecosistemas Mediterráneos, en especial en el contexto actual de cambio climático, y el incremento asociado de temperatura y periodos de sequía, alteración de los patrones de precipitación, y el riesgo de incendios forestales; cuyas consecuencias afectarán tanto a los compartimentos de C y de N del suelo como a la capacidad de secuestro de C de estos ecosistemas. Dentro de este contexto se enmarca la presente tesis doctoral cuyo objetivo ha sido cuantificar y caracterizar los flujos de dióxido de carbono (CO2), de oxido nitroso (N2O) y de metano (CH4), junto con los stocks de C y N, en suelos forestales de Quercus ilex, Quercus pyrenaica y Pinus sylvestris afectados por incendios forestales; así como el estudiar el efecto de la gestión y la cubierta arbórea en la respiración del suelo y los stocks de C y N en una dehesa situada en el centro de la Península Ibérica. De manera que los flujos de CO2, N2O y CH4; y los parámetros físico-químicos y biológicos del suelo fueron estudiados en los diferentes tratamientos y ecosistemas a lo largo del trabajo que se presenta. Los resultados obtenidos muestran la existencia de variaciones temporales y espaciales de la respiración del suelo dentro de una escala geográfica pequeña, controladas principalmente por la temperatura y la humedad del suelo; y por los contenidos de C y N del suelo en un bosque de Pinus sylvestris en la vertiente norte de la Sierra de Guadarrama , en España. El análisis de los efectos de los incendios forestales a largo plazo (6-8 años) revela que las pérdidas anuales de C a través de la respiración del suelo en las zonas quemadas de Quercus ilex, Quercus pyrenaica y Pinus sylvestris fueron 450 gCm-2yr-1, 790 gCm-2yr-1 y 1220 gCm-2yr-1, respectivamente; lo que representa una reducción del 43%, 22% y 11% en comparación con las zonas no quemadas de dichas especies, debido a la destrucción de la masa arbórea. El efecto del fuego también alteró los flujos N2O y CH4 del suelo, de una forma diferente en los distintos ecosistemas y estacionalidades estudiadas. De tal modo, que los suelos quemados mostraron una mayor oxidación del CH4 en las masas de Q. ilex, y una menor oxidación en las de P. sylvestris; además de una disminución de los flujos de N2O en Q. pyrenaica. Los incendios también afectaron los parámetros microclimáticos de los suelos forestales, observándose un incremento de la temperatura del suelo y una disminución de la humedad en los emplazamientos quemados que en los no quemados. Los cationes intercambiables, el pH, el cociente C/N, el contenido en raicillas y la biomasa microbiana también disminuyeron en las zonas quemadas. Aunque el C orgánico del suelo no se alteró de manera significativa, si lo hizo la calidad de la materia orgánica, disminuyendo el carbono lábil y aumentando las formas recalcitrantes lo que se tradujo en menor sensibilidad de la respiración del suelo a la temperatura (valores de Q10) en las zonas quemadas. Los resultados del estudio realizado en la Dehesa muestran que las actividades silvopastorales estudiadas afectaron levemente y de forma no constante a la respiración del suelo y las condiciones microclimáticas del suelo. Se observó una reducción 12% de la respiración del suelo por efecto del pastoreo no intensivo. Sin embargo, se observaron incrementos de 3Mg/ha en los stocks de C y de 0.3 Mg/ha en los stocks de N en los suelos pastoreados en comparación con los no pastoreados. Aunque, no se observó un claro efecto de la labranza sobre la respiración del suelo en nuestro experimento, sin embargo si se observó una disminución de 3.5 Mg/ha en las reservas de C y de 0.3 Mg/ ha en las de N en los suelos labrados comparados con los no labrados. La copa del arbolado influyó de forma positiva tanto en la respiración del suelo, como en los stocks de C y N de los suelos. La humedad del suelo jugó un papel relevante en la sensibilidad de la respiración a la temperatura del suelo. Nuestros resultados ponen de manifiesto la sensibilidad de la respiración del suelo a cambios en la humedad y los parámetros edáficos, y sugieren que la aplicación de modelos estándar para estimar la respiración del suelo en áreas geográficas pequeñas puede no ser adecuada a menos que otros factores sean considerados en combinación con la temperatura del suelo. Además, las diferentes respuestas de los flujos de gases de efecto invernadero a los cambios, años después de la ocurrencia de incendios forestales, destaca la necesidad de incluir estos cambios en las futuras investigaciones de la dinámica del carbono en los ecosistemas mediterráneos. Por otra parte, las respuestas divergentes en los valores de respiración del suelo y en los contenidos de C y N del suelo observados en la dehesa, además de la contribución de la copa de los árboles en los nutrientes del suelo ilustran la importancia de mantener la gestión tradicional aplicada en beneficio de la capacidad de almacenar C en la dehesa estudiada. La información obtenida en este trabajo pretende contribuir a la mejora del conocimiento de la dinámica y el balance de C en los sistemas mediterráneos, además de ayudar a predecir el impacto del cambio climático en el intercambio de C entre los ecosistemas forestales y agroforestales y la atmósfera. ABSTRACT Due to the complexity of the processes that control the exchange of carbon (C) and nitrogen (N) gasses between soils and the atmosphere in forest and agroforestry ecosystems, understandable uncertainties exist as regards the estimation of greenhouse gas (GHG) fluxes and the soil sink capacity at regional and global scale under different forms of land use and disturbance regimes. These uncertainties justify the need to characterize the exchange dynamics of GHG between the atmosphere and soils in Mediterranean terrestrial ecosystems, particularly in the current context of climate change and the associated increase in temperature, drought periods, heavy rainfall events, and increased risk of wildfires, which affect not only the C and N pools but also the soil C sink capacity of these ecosystems. Within this context, the aims of the present thesis were, firstly, to quantify and characterize the fluxes of carbon dioxide (CO2), nitrous oxide (N2O) and methane (CH4) as well as the C and N stocks in Quercus ilex, Quercus pyrenaica and Pinus sylvestris stands affected by wildfires, and secondly, to study the effects of Quercus ilex canopy and management on both soil respiration and C and N pools in dehesa systems in the center of Iberian Peninsula. Soil CO2, N2O and CH4 fluxes, and soil physical-chemical and biological parameters were studied under the different treatments and ecosystems considered in this study. The results showed seasonal and spatial variations in soil respiration within small geographic areas, mainly controlled by soil temperature and moisture in addition to soil carbon and nitrogen stocks in mixed pine–oak forest ecosystems on the north facing slopes of the Sierra de Guadarrama in Spain. The analysis of long term effects of wildfires (6–8 years) revealed that annual carbon losses through soil respiration from burned sites in Quercus ilex, Quercus pyrenaica and Pinus sylvestris stands were 450 gCm-2yr-1, 790 gCm-2yr-1 and 1220 gCm-2yr-1, respectively; with burned sites emitting 43%, 22% and 11% less in burned as opposed to non-burned sites due the loss of trees. Fire may alter both N2O and CH4 fluxes although the magnitude of such variation depends on the site, soil characteristics and seasonal climatic conditions. The burned sites showed higher CH4 oxidation in Q.ilex stands, and lower oxidation rates in P. sylvestris stands. A reduction in N2O fluxes in Q. pyrenaica stands was detected at burned sites along with changes in soil microclimate; higher soil temperature and lower soil moisture content. Exchangeable cations, the C/N ratio, pH, fine root and microbial biomass were also found to decrease at burned sites. Although the soil organic carbon was not significantly altered, the quality of the organic matter changed, displaying a decrease in labile carbon and a relative increase in refractory forms, leading to lower sensitivity of soil respiration to temperature (Q10 values) at burned sites. The results from the dehesa study show that light grazing and superficial tilling practices used in the studied dehesa system in Spain had a slight but non-consistent impact on soil respiration and soil microclimate over the study period. The reduction in soil respiration in the dehesa system due to the effects of grazing was around 12 %. However, increments of 3Mg/ha in C stocks and 0.3 Mg/ha in N stocks in grazed soils were observed. Although no clear effect of tilling on soil respiration was found, a decrease of 3.5 Mg/ha in C stocks and 0.3 Mg/ha in N stocks was detected for tilled soils. The presence of a tree canopy induced increases in soil respiration, soil C and N stocks, while soil moisture was found to play an important role in soil respiration temperature response. Our results suggest that the use of standard models to estimate soil respiration in small geographical areas may not be adequate unless other factors are considered in addition to soil temperature. Furthermore, the different responses of GHG flux to climatic shifts, many years after the occurrence of wildfire, highlight the need to include these shifts in C dynamics in future research undertaken in Mediterranean ecosystems. Furthermore, divergent responses in soil respiration and soil C and N stocks to grazing or tilling practices in Dehesa systems, and the influence of tree canopy on soil respiration and soil nutrient content, illustrate the importance of maintaining beneficial management practices. Moreover, the carbon sequestration capacity of the Dehesa system studied may be enhanced through improvements in the management applied. It is hoped that the information obtained through this research will contribute towards improving our understanding of the dynamics and balance of C in Mediterranean systems, and help predict the impact of climate change on the exchange of C between forest and agroforestry ecosystems and the atmosphere.
Resumo:
In warm and dry climates, the use of porous systems should be required in order to allow a better leaf distribution inside the plant, causing more space in the clusters area and enhancing determined physiological processes so in the leaf (photosynthesis, v entilation, transpiration) as in berry (growth and maturation). Plant geometry indexes, yield and must composition have been studied in three different systems: sprawl with 12 shoots/m (S1); sprawl system with 18 shoots/m (S2) and vertical positioned syste m or VSP with 12 shoots/m (VSP1). Total leaf area increases as the crop load does, whoever surface area depends on to two factors: crop load and the training system (VSP vs. sprawl), which can provide differences in leaf exposure efficiencies. The main objective of this study was to validate digital photography measurements used to compare porosity differences among treatments and, as they affect plant microclimate and, therefore, yield and berry quality. Also, all previous studied indexes (LAI, SA, SFEr) tended to overestimate the relationship between exposed leaf surface and porosity of each treatment, but the use of digital method proved to be an effective tool in order to assess canopy porosity. Results showed that not positioned and free systems (sprawl) scored between 25- 50% more porosity in the clusters area than the fixed vertical system (VSP), which resulted in a better plant microclimate for test conditions, mainly by improving the exposure of internal clusters and internal canopy ventilation. On the other hand, higher crop load treatment (S2) showed a real increase in yield (16%) without any relevant change into must composition, even improving total anthocyanin content into berry during ripening
Resumo:
In warm and dry climates, the use of porous systems should be required in order to allow a better leaf distribution inside the plant, causing more space in the clusters area and enhancing determined physiological processes so in the leaf (photosynthesis, ventilation, transpiration) as in berry (growth and maturation). Plant geometry indexes, yield and must composition have been studied in three different systems: sprawl with 12 shoots/m (S1); sprawl system with 18 shoots/m (S2) and vertical positioned system or VSP with 12 shoots/m (VSP1). Total leaf area increases as the crop load does, whoever surface area depends on to two factors: crop load and the training system (VSP vs . sprawl), which can provide differences in leaf exposure efficiencies. The main objective of this study was to validate digital photography measurements used to compare porosity differences among treatments and, as they affect plant microclimate and, therefore, yield and berry quality. Also, all previous studied indexes (LAI, SA, SFEr) tended to overestimate the relationship between exposed leaf surface and porosity of each treatment, but the use of digital method proved to be an effective tool in order to assess canopy porosity. Results showed that not positioned and free systems (sprawl) scored between 25 - 50% more porosity in the clusters area than the fixed vertical system (VSP), which resulted in a better plant microclimate for test conditions, mainly by improving the exposure of internal clusters and internal canopy ventilation. On the other hand, higher crop load treatment (S2) showed a real increase in yield (16%) without any relevant change into must composition, even improving total anthocyanin content into berry during ripening
Resumo:
Article New Forests November 2015, Volume 46, Issue 5, pp 869-883 First online: 17 June 2015 Establishing Quercus ilex under Mediterranean dry conditions: sowing recalcitrant acorns versus planting seedlings at different depths and tube shelter light transmissionsJuan A. OlietAffiliated withDepartamento de Sistemas y Recursos Naturales, E.T.S. Ingenieros de Montes, Universidad Politécnica de Madrid Email author View author's OrcID profile , Alberto Vázquez de CastroAffiliated withDepartamento de Sistemas y Recursos Naturales, E.T.S. Ingenieros de Montes, Universidad Politécnica de Madrid, Jaime PuértolasAffiliated withLancaster Environment Centre, Lancaster University $39.95 / €34.95 / £29.95 * Rent the article at a discount Rent now * Final gross prices may vary according to local VAT. Get Access AbstractSuccess of Mediterranean dry areas restoration with oaks is a challenging goal. Testing eco-techniques that mimic beneficial effects of natural structures and ameliorate stress contributes to positive solutions to overcoming establishment barriers. We ran a factorial experiment in a dry area, testing two levels of solid wall transmission of tube shelters (60 and 80 %) plus a control mesh, and two depths (shallow and 15 cm depth) of placing either planted seedlings or acorns of Quercus ilex. Microclimate of the planting or sowing spots was characterized by measuring photosynthetically active radiation, temperature and relative humidity. Plant response was evaluated in terms of survival, phenology, acorn emergence and photochemical efficiency (measured through chlorophyll fluorescence). We hypothesize that tube shelters and deep planting improve Q. ilex post-planting and sowing performance because of the combined effects of reducing excessive radiation and improving access to moist soil horizons. Results show that temperature and PAR was reduced, and relative humidity increased, in deep spots. Midsummer photochemical efficiency indicates highest level of stress for oaks in 80 % light transmission shelter. Optimum acorn emergence in spring was registered within solid wall tree shelters, and maximum summer survival of germinants and of planted seedlings occurred when acorns or seedlings were placed at 15 cm depth irrespectively of light transmission of shelter. Survival of germinants was similar to that of planted seedlings. The importance of techniques to keep high levels of viability after sowing recalcitrant seeds in the field is emphasized in the study
Resumo:
La importancia de conocer bien el entorno para un proyecto arquitectónico es que podemos adaptarlo a nuestras necesidades fisiológicas de Confort Térmico. Podemos decir entonces que el edificio juega un papel fundamental como técnica de control de nuestro entorno. El edificio nos debería entregar un entorno controlado para que nos sintamos bien térmicamente, considerando además, que la arquitectura por sí misma puede lograr dicho confort la mayor parte de las veces. De no ser así, los usuarios tienden a colocar elementos mecánicos, para generar frío o calor artificialmente. Es fundamental entonces que nuestros edificios, tengan una correcta interacción con los recursos naturales del lugar para lograr dicho confort térmico. Pero lograr el Confort Térmico en todos los edificios de una ciudad como unidad, no logrará que la ciudad entera sea confortable térmicamente, ya que las complejas interacciones hacen que la problemática se deba enfrentar como algo sistémico. Esto quiere decir, que para que una ciudad o un conjunto logren la Confortabilidad Térmica deseada por sus habitantes debiera haber sido planificada conforme a variables urbanas que interactúen con el medio natural en forma eficiente. Con la observación de ciertos conjuntos habitacionales antiguos en el interior del Valle del Elqui, Chile y de sus relaciones entre variables urbanas y naturales, queda de manifiesto ciertas características que conllevan a pensar que existió una planificación ambiental en éstos que llevaron a lograr un conjunto con características bioclimáticas. Las evidencias de la existencia en primer lugar de un patrón urbanístico en dichos conjuntos habitacionales antiguos, hacen pensar que dicho patrón se trataría de un patrón bioclimático rural planificado, lo que hace que exista un gran interés por el estudio de estos conjuntos. Hasta ahora, en Chile, los pocos estudios de Confort Térmico que existen, están orientados a edificaciones aisladas, al Confort térmico interior de la edificación en el ámbito urbano, y en nada a Patrones Bioclimáticos de Conjuntos Habitacionales en una situación de ruralidad como a la referida en esta investigación. Además, los estudios referidos al clima urbano, difieren a los del clima rural, por lo que se necesitan mayores estudios aún para comprender mejor la problemática. Es por esto, que la mayoría de los casos mencionados en este estudio son contextualizados al ámbito urbano por carecer de otros estudios rurales. Es en este sentido que esta investigación cobra real importancia y pretende establecer la relación existente entre las variables morfológicas rurales y los recursos naturales del lugar y que generan un confort térmico ideal para sus habitantes, al mismo tiempo, se analiza la existencia de un Patrón Bioclimático en un poblado denominado Algarrobito ubicado en la cuenca del Valle del Elqui, Chile. Es en este sentido que el propósito principal de este trabajo es determinar la real existencia de un Patrón Bioclimático que relacione la morfología rural y edificada de los antiguos poblados pertenecientes a la cuenca del Valle de Elqui Chile con el microclima del lugar. La metodología empleada se basa en realizar primeramente el estudio del microclima del lugar a través de las Cartas Bioclimáticas. Para ello se obtuvo información de datos climatológicos de las estaciones meteorológicas ubicadas en la cuenca del Valle de Elqui, principalmente las más cercanas al lugar de estudio. Mediante una revisión exhaustiva de la información arquitectónica, así como de una labor de reconocimiento en terreno realizada en el poblado seleccionado y de la aplicación del Climograma local, se identificaron las diferentes zonas bioclimáticas del poblado antiguo y potenciales áreas de estudio en el conjunto. Esta actividad incluyó un estudio preliminar de la energía solar local, vientos, humedad, temperaturas y su interacción con el conjunto, permitiendo una primera aproximación a la problemática del espacio exterior y las viviendas. Esto permitió en base a las condicionantes del lugar, la arquitectura vernácula y los materiales descubrir un Patrón en el antiguo conjunto que permitía entregar confortabilidad térmica a sus habitantes y darse cuenta también, que el nuevo conjunto emplazado en el sector no seguía ese patrón con las disfuncionalidades que ello llevaba. Con esto quedó demostrado en primer lugar la existencia de un Patrón Bioclimático rural, los beneficios del patrón, la importancia de éste como causante de Confortabilidad Térmica del conjunto, y por ende de mejor eficiencia energética, así como también, que el nuevo conjunto no sigue para nada este Patrón, pero que existe también la posibilidad de rectificación y por supuesto, que los nuevos desarrollos residenciales del Valle del Elqui, puedan planificarse en base al patrón bioclimático descubierto. ABSTRACT Knowing the environment of an architectonic proyect is really important for adjusting it to our physiological needs of Thermal Comfort. So we can say that the building plays a key role as a technique of control of our environment. The building should give us a controlled environment to make us feel good thermally, and it usually can reach pleasurable temperatures by itself. If it isn't like that, people cooled or heated the ambience with mechanical elements. So a correct interaction between the buildings and natural resources is important to reach a thermal comfort. But achieving Thermal Comfort in all the buildings of a city as a unit will not achieve the whole city is thermally comfortable, because the complex interactions cause the problem needs to be solved as something systemic. This means that for a city or a set reach the Thermal Comfortability desired by its inhabitants, it should have been planned according to the urban variables that interact with the natural environment efficiently. Observing some old housing complexes in Elqui Valley, Chile, and the relationships between their natural and urban variables, some features lead to think that the environmental planning in these led to achieve a set with bioclimatic features. First, the evidences about the existence of an urban pattern in those old housing complexes, make thinking that the pattern would be a planned urban pattern, which generates interest in its study. In Chile, there have been few studies about Thermal Comfort, oriented to isolated buildings and indoor thermal comfort, but Bioclimatic Urban Patterns haven't been studied at all. In this sense, this investigation acquires a real importance and pretends to establish the relationship between urban variables and natural resources of the place that generates a good thermal comfort for its habitants. At the same time, the existence of a Bioclimatic Urban Pattern in Algarrobito, located in Elqui Valley basin, Chile, is analized. It is in this sense that the main purpose of this work is to determine the real existence of a Bioclimatic Urban Pattern, that links the urban and constructive form of the old villages of it with its microclimate. The methodology used is based on performing first the study of the microclimate of the place through the Bioclimatic Cards. To do this, weather stations, located in Elqui valley, near the place that was studied, were used to obtain information of climatological data. The different bioclimatic zones to the old town and potential areas of study in the set were identified, through an exhaustive review of the architectural information, a field reconnaissance work performed on the selected town and the application of the Local Climograph. This activity included a preliminary study of the local solar energy, the winds, the moisture, the temperatures, and their interaction with the set, allowing a first aproximation to troubles of outer space and housing. This allowed, based on the conditions of the place, vernacular architecture and materials, discovering an urban pattern in the old set, which allowed to give thermal comfort to its inhabitants and realize that the new set of the place did not follow this pattern, with the dysfunctions that it carried. These points demonstrated, in first place, the existence of a Bioclimatic Urban Pattern, the benefits of it, the importance of it as a cause of Thermal Comfortability, and therefore a better efficiency of energy, also that the new set doesn’t follow this Pattern at all, but that the posibility of rectification exists and, of course, that the new residencial development in Elqui Valley can be planned based on bioclimatic pattern discovered.
Resumo:
El cambio climático y sus efectos requieren con urgencia el desarrollo de estrategias capaces no solo de mitigar pero también permitir la adaptación de los sistemas afectados por este fenómeno a los cambios que están provocando a nivel mundial. Olas de calor más largas y frecuentes, inundaciones, y graves sequías aumentan la vulnerabilidad de la población, especialmente en asentamientos urbanos. Este fenómeno y sus soluciones potenciales han sido ampliamente estudiados en las últimas décadas desde diferentes perspectivas y escalas que analizan desde el fenómeno regional de isla de calor al aumento de la intensidad energética necesaria en los edificios para mantener las condiciones de confort en los escenarios de calentamiento que se predicen. Su comprensión requiere el entendimiento de este fenómeno y un profundo análisis de las estrategias que pueden corregirlo y adaptarse a él. En la búsqueda de soluciones a este problema, las estrategias que incorporan sistemas naturales tales como las cubiertas ajardinadas, las fachadas vegetadas y bosques urbanos, se presentan como opciones de diseño capaces de proporcionan múltiples servicios al ecosistema urbano y de regular y hacer frente a los efectos del cambio climático. Entre los servicios que aportan estos sistemas naturales se incluyen la gestión de agua de tormentas, el control del efecto isla de calor, la mejora de la calidad del aire y del agua, el aumento de la diversidad, y como consecuencia de todo lo anterior, la reducción de la huella ecológica de las ciudades. En la última década, se han desarrollado múltiples estudios para evaluar y cuantificar los servicios al ecosistema proporcionados por las infraestructuras verdes, y específicamente las cubiertas ajardinadas, sin embargo, determinados servicios como la capacidad de la regulación del microclima urbano no ha sido apenas estudiados. La mayor parte de la literatura en este campo la componen estudios relacionados con la capacidad de las cubiertas ajardinadas de reducir el efecto de la isla de calor, en una escala local, o acerca de la reducción de la demanda energética de refrigeración debida a la instalación de cubiertas ajardinadas en la escala de edificio. La escala intermedia entre estos dos ámbitos, la calle, desde su ámbito habitable cercano al suelo hasta el límite superior del cañón urbano que configura, no han sido objeto detallado de estudio por lo que es esta escala el objeto de esta tesis doctoral. Esta investigación tiene como objeto contribuir en este campo y aportar un mayor entendimiento a través de la cuantificación del impacto de las cubiertas ajardinadas sobre la temperatura y humedad en el cañón urbano en la escala de calle y con un especial foco en el nivel peatonal. El primer paso de esta investigación ha sido la definición del objeto de estudio a través del análisis y revisión de trabajos tanto teóricos como empíricos que investigan los efectos de cubiertas ajardinadas en el entorno construido, entendidas como una herramienta para la adaptación y mitigación del impacto del cambio climático en las ciudades. La literatura analizada, revela el gran potencial de los sistemas vegetales como herramientas para el diseño pasivo puesto que no solo son capaces de mejorar las condiciones climáticas y microclimaticas en las ciudades reduciendo su demanda energética, sino también la necesidad de mayor análisis en la escala de calle donde confluyen el clima, las superficies urbanas y materiales y vegetación. Este análisis requiere una metodología donde se integren la respuesta térmica de edificios, las variaciones en los patrones de viento y radiación, y la interacción con la vegetación, por lo que un análisis cuantitativo puede ayudar a definir las estrategias más efectivas para lograr espacios urbanos más habitables. En este contexto, el objetivo principal de esta investigación ha sido la evaluación cuantitativa del impacto de la cubierta ajardinada en el microclima urbano a escala de barrio en condiciones de verano en los climas mediterráneos continentales. Para el logro de este objetivo, se ha seguido un proceso que persigue identificar los modelos y herramientas de cálculo capaces de capturar el efecto de la cubierta ajardinada sobre el microclima, identificar los parámetros que potencian o limitan este efecto, y cuantificar las variaciones que microclima creado en el cañón urbano produce en el consumo de energía de los edificios que rodean éste espacio. La hipótesis principal detrás de esta investigación y donde los objetivos anteriores se basan es el siguiente: "una cubierta ajardinada instalada en edificios de mediana altura favorece el establecimiento de microclimas a nivel peatonal y reduce las temperaturas en el entorno urbano donde se encuentra”. Con el fin de verificar la hipótesis anterior y alcanzar los objetivos propuestos se ha seguido la siguiente metodología: • definición del alcance y limitaciones del análisis • Selección de las herramientas y modelos de análisis • análisis teórico de los parámetros que afectan el efecto de las cubiertas ajardinadas • análisis experimental; • modelización energética • conclusiones y futuras líneas de trabajo Dada la complejidad de los fenómenos que intervienen en la generación de unas determinadas condiciones microclimáticas, se ha limitado el objeto de este estudio a las variables de temperatura y humedad, y sólo se han tenido en cuenta los componentes bióticos y abióticos del sistema, que incluyen la morfología, características superficiales del entorno estudiado, así como los elementos vegetales. Los componentes antrópicos no se han incluido en este análisis. La búsqueda de herramientas adecuadas para cumplir con los objetivos de este análisis ha concluido en la selección de ENVI-met v4 como el software más adecuado para esta investigación por su capacidad para representar los complejos fenómenos que caracterizan el microclima en cañones urbanos, en una escala temporal diaria y con unas escala local de vecindario. Esta herramienta supera el desafío que plantean los requisitos informáticos de un cálculo completo basado en elementos finitos realizados a través de herramientas de dinámica de fluidos computacional (CFD) que requieren una capacidad de cálculo computacional y tiempo privativos y en una escala dimensional y temporal limitada a esta capacidad computacional lo que no responde a los objetivos de esta investigación. ENVI-met 4 se basa es un modelo tridimensional del micro clima diseñado para simular las interacciones superficie-planta-aire en entornos urbanos. Basado en las ecuaciones fundamentales del equilibrio que representan, la conservación de masa, energía y momento. ENVI-met es un software predictivo, y como primer paso ha requerido la definición de las condiciones iniciales de contorno que se utilizan como punto de partida por el software para generar su propio perfil de temperatura y humedad diaria basada en la localización de la construcción, geometría, vegetación y las superficies de características físicas del entorno. La geometría de base utilizada para este primer análisis se ha basado en una estructura típica en cuanto al trazado urbano situada en Madrid que se ha simulado con una cubierta tradicional y una cubierta ajardinada en sus edificios. La estructura urbana seleccionada para este análisis comparativo es una red ortogonal con las calles principales orientadas este-oeste. El edificio típico que compone el vecindario se ha definido como “business as usual” (BAU) y se ha definido con una cubierta de baldosa de hormigón estándar, con un albedo 0.3, paredes con albedo 0.2 (construcción de muro de ladrillo típico) y cerramientos adiabáticos para evitar las posibles interferencias causadas por el intercambio térmico con el ambiente interior del edificio en los resultados del análisis. Para el caso de la cubierta ajardinada, se mantiene la misma geometría y características del edificio con excepción de la cobertura superficial de la azotea. Las baldosas de hormigón se han modificado con una cubierta ajardinada extensiva cubierta con plantas xerófilas, típicas en el clima de Madrid y caracterizado por su índice de densidad foliar, el “leaf area density” (LAD), que es la superficie total de superficie de hojas por unidad de volumen (m2/m3). El análisis se centra en los cañones urbanos entendidos como el espacio de calle comprendido entre los límites geométricos de la calle, verticales y horizontales, y el nivel superior de la cota urbana nivel de cubiertas. Los escenarios analizados se basan en la variación de la los principales parámetros que según la literatura analizada condicionan las variaciones microclimáticas en el ámbito urbano afectado por la vegetación, la velocidad del viento y el LAD de la azotea. Los resultados han sido registrados bajo condiciones de exposición solar diferentes. Las simulaciones fueron realizadas por los patrones de viento típico de verano, que para Madrid se caracterizan por vientos de componente suroeste que van desde 3 a 0 m/s. las simulaciones fueron realizadas para unas condiciones climáticas de referencia de 3, 2, 1 y 0 m/s a nivel superior del cañón urbano, como condición de contorno para el análisis. Los resultados calculados a 1,4 metros por encima del nivel del suelo, en el espacio habitado, mostraron que el efecto de la cubierta ajardinada era menor en condiciones de contorno con velocidades de viento más altas aunque en ningún caso el efecto de la cubierta verde sobre la temperatura del aire superó reducciones de temperatura de aire superiores a 1 º C. La humedad relativa no presentó variaciones significativas al comparar los diferentes escenarios. Las simulaciones realizadas para vientos con velocidad baja, entre 0 y 1 m/s mostraron que por debajo de 0.5 m/s la turbulencia del modelo aumentó drásticamente y se convirtió en el modelo inestable e incapaz de producir resultados fiables. Esto es debido al modelo de turbulencia en el software que no es válido para velocidades de viento bajas, lo que limita la capacidad de ENVI-met 4 para realizar simulaciones en estas condiciones de viento y es una de las principales conclusiones de este análisis en cuanto a la herramienta de simulación. También se comprobó el efecto de las densidades de la densidad de hoja (LAD) de los componentes vegetales en el modelo en la capa de aire inmediatamente superior a la cubierta, a 0,5 m sobre este nivel. Se compararon tres alternativas de densidad de hoja con la cubierta de baldosa de hormigón: el techo verde con LAD 0.3 (hierba típica o sedum), LAD 1.5 (plantas mixtas típicas) y LAD 2.5 (masa del árbol). Los resultados mostraron diferencias de temperatura muy relevante entre las diferentes alternativas de LAD analizadas. Los resultados muestran variaciones de temperatura que oscilan entre 3 y 5 º C al comparar el estándar de la azotea concreta con albedo 0, 3 con el techo con vegetación y vegetación densa, mostrando la importancia del LAD en la cuantificación de los efectos de las cubiertas vegetales en microclima circundante, lo que coincide con los datos reportados en la literatura existente y con los estudios empíricos analizados. Los resultados de los análisis teóricos han llegado a las siguientes conclusiones iniciales relacionadas con la herramienta de simulación y los resultados del modelo: En relación con la herramienta ENVI-met, se han observado limitaciones para el análisis. En primer lugar, la estructura rígida de la geometría, las bases de datos y el tamaño de la cuadrícula, limitan la escala y resolución de los análisis no permitiendo el desarrollo de grandes zonas urbanas. Por otro lado la estructura de ENVI-met permite el desarrollo de este tipo de simulación tan complejo dentro de tiempos razonables de cálculo y requerimientos computacionales convencionales. Otra limitación es el modelo de turbulencia del software, que no modela correctamente velocidades de viento bajas (entre 0 y 1 m/s), por debajo de 0,5 m/s el modelo da errores y no es estable, los resultados a estas velocidades no son fiables porque las turbulencias generadas por el modelo hacen imposible la extracción de patrones claros de viento y temperatura que permitan la comparación entre los escenarios de cubierta de hormigón y ajardinada. Además de las limitaciones anteriores, las bases de datos y parámetros de entrada en la versión pública del software están limitados y la complejidad de generar nuevos sistemas adaptándolos al edificio o modelo urbano que se quiera reproducir no es factible salvo en la versión profesional del software. Aparte de las limitaciones anteriores, los patrones de viento y perfiles de temperatura generados por ENVI-met concuerdan con análisis previos en los que se identificaban patrones de variación de viento y temperaturas en cañones urbanos con patrones de viento, relación de aspecto y dimensiones similares a los analizados en esta investigación. Por lo tanto, el software ha demostrado una buena capacidad para reproducir los patrones de viento en los cañones de la calle y capturar el efecto de enfriamiento producido por la cubierta verde en el cañón. En relación con el modelo, el resultado revela la influencia del viento, la radiación y el LAD en la temperatura del aire en cañones urbanos con relación de aspecto comprendida entre 0,5 y 1. Siendo el efecto de la cubierta verde más notable en cañones urbanos sombreados con relación de aspecto 1 y velocidades de viento en el nivel de “canopy” (por encima de la cubierta) de 1 m/s. En ningún caso las reducciones en la temperatura del aire excedieron 1 º C, y las variaciones en la humedad relativa no excedieron 1% entre los escenarios estudiados. Una vez que se han identificado los parámetros relevantes, que fueron principalmente la velocidad del viento y el LAD, se realizó un análisis experimental para comprobar los resultados obtenidos por el modelo. Para éste propósito se identificó una cubierta ajardinada de grandes dimensiones capaz de representar la escala urbana que es el objeto del estudio. El edificio usado para este fin fue el parking de la terminal 4 del aeropuerto internacional de Madrid. Aunque esto no es un área urbana estándar, la escala y la configuración del espacio alrededor del edificio fueron considerados aceptables para el análisis por su similitud con el contexto urbano objeto de estudio. El edificio tiene 800 x 200 m, y una altura 15 m. Está rodeado de vías de acceso pavimentadas con aceras conformando un cañón urbano limitado por el edificio del parking, la calle y el edificio de la terminal T4. El aparcamiento está cerrado con fachadas que configuran un espacio urbano de tipo cañón, con una relación de aspecto menor que 0,5. Esta geometría presenta patrones de viento y velocidad dentro del cañón que difieren ligeramente de los generados en el estudio teórico y se acercan más a los valores a nivel de canopo sobre la cubierta del edificio, pero que no han afectado a la tendencia general de los resultados obtenidos. El edificio cuenta con la cubierta ajardinada más grande en Europa, 12 Ha cubiertas por con una mezcla de hierbas y sedum y con un valor estimado de LAD de 1,5. Los edificios están rodeados por áreas plantadas en las aceras y árboles de sombra en las fachadas del edificio principal. El efecto de la cubierta ajardinada se evaluó mediante el control de temperaturas y humedad relativa en el cañón en un día típico de verano. La selección del día se hizo teniendo en cuenta las predicciones meteorológicas para que fuesen lo más semejantes a las condiciones óptimas para capturar el efecto de la cubierta vegetal sobre el microclima urbano identificadas en el modelo teórico. El 09 de julio de 2014 fue seleccionado para la campaña de medición porque las predicciones mostraban 1 m/s velocidad del viento y cielos despejados, condiciones muy similares a las condiciones climáticas bajo las que el efecto de la cubierta ajardinada era más notorio en el modelo teórico. Las mediciones se registraron cada hora entre las 9:00 y las 19:00 en 09 de julio de 2014. Temperatura, humedad relativa y velocidad del viento se registraron en 5 niveles diferentes, a 1.5, 4.5, 7.5, 11.5 y 16 m por encima del suelo y a 0,5 m de distancia de la fachada del edificio. Las mediciones fueron tomadas en tres escenarios diferentes, con exposición soleada, exposición la sombra y exposición influenciada por los árboles cercanos y suelo húmedo. Temperatura, humedad relativa y velocidad del viento se registraron con un equipo TESTO 410-2 con una resolución de 0,1 ºC para temperatura, 0,1 m/s en la velocidad del viento y el 0,1% de humedad relativa. Se registraron las temperaturas de la superficie de los edificios circundantes para evaluar su efecto sobre los registros usando una cámara infrarroja FLIR E4, con resolución de temperatura 0,15ºC. Distancia mínima a la superficie de 0,5 m y rango de las mediciones de Tª de - 20 º C y 250 º C. Los perfiles de temperatura extraídos de la medición in situ mostraron la influencia de la exposición solar en las variaciones de temperatura a lo largo del día, así como la influencia del calor irradiado por las superficies que habían sido expuestas a la radiación solar así como la influencia de las áreas de jardín alrededor del edificio. Después de que las medidas fueran tomadas, se llevaron a cabo las siguientes simulaciones para evaluar el impacto de la cubierta ajardinada en el microclima: a. estándar de la azotea: edificio T4 asumiendo un techo de tejas de hormigón con albedo 0.3. b. b. cubierta vegetal : T4 edificio asumiendo una extensa cubierta verde con valor bajo del LAD (0.5)-techo de sedum simple. c. c. cubierta vegetal: T4 edificio asumiendo una extensa cubierta verde con alta joven valor 1.5-mezcla de plantas d. d. cubierta ajardinada más vegetación nivel calle: el edificio T4 con LAD 1.5, incluyendo los árboles existentes a nivel de calle. Este escenario representa las condiciones actuales del edificio medido. El viento de referencia a nivel de cubierta se fijó en 1 m/s, coincidente con el registro de velocidad de viento en ese nivel durante la campaña de medición. Esta velocidad del viento se mantuvo constante durante toda la campaña. Bajo las condiciones anteriores, los resultados de los modelos muestran un efecto moderado de azoteas verdes en el microclima circundante que van desde 1 º a 2 º C, pero una contribución mayor cuando se combina con vegetación a nivel peatonal. En este caso las reducciones de temperatura alcanzan hasta 4 ºC. La humedad relativa sin embargo, no presenta apenas variación entre los escenarios con y sin cubierta ajardinada. Las temperaturas medidas in situ se compararon con resultados del modelo, mostrando una gran similitud en los perfiles definidos en ambos casos. Esto demuestra la buena capacidad de ENVI-met para reproducir el efecto de la cubierta ajardinada sobre el microclima y por tanto para el fin de esta investigación. Las diferencias más grandes se registraron en las áreas cercanas a las zonas superiores de las fachadas que estaban más expuestas a la radiación del sol y también el nivel del suelo, por la influencia de los pavimentos. Estas diferencias se pudieron causar por las características de los cerramientos en el modelo que estaban limitados por los datos disponibles en la base de datos de software, y que se diferencian con los del edificio real. Una observación importante derivada de este estudio es la contribución del suelo húmedo en el efecto de la cubierta ajardinada en la temperatura del aire. En el escenario de la cubierta ajardinada con los arboles existentes a pie de calle, el efecto del suelo húmedo contribuye a aumentar las reducciones de temperatura hasta 4.5ºC, potenciando el efecto combinado de la cubierta ajardinada y la vegetación a pie de calle. Se realizó un análisis final después de extraer el perfil horario de temperaturas en el cañón urbano influenciado por el efecto de las cubiertas ajardinadas y los árboles. Con esos perfiles modificados de temperatura y humedad se desarrolló un modelo energético en el edificio asumiendo un edificio cerrado y climatizado, con uso de oficinas, una temperatura de consigna de acuerdo al RITE de 26 ºC, y con los sistemas por defecto que establece el software para el cálculo de la demanda energética y que responden a ASHRAE 90.1. El software seleccionado para la simulación fue Design Builder, por su capacidad para generar simulaciones horarias y por ser una de las herramientas de simulación energética más reconocidas en el mercado. Los perfiles modificados de temperatura y humedad se insertaron en el año climático tipo y se condujo la simulación horaria para el día definido, el 9 de Julio. Para la simulación se dejaron por defecto los valores de conductancia térmica de los cerramientos y la eficiencia de los equipos de acuerdo a los valores que fija el estándar ASHRAE para la zona climática de Madrid, que es la 4. El resultado mostraba reducciones en el consumo de un día pico de hasta un 14% de reducción en las horas punta. La principal conclusión de éste estudio es la confirmación del potencial de las cubiertas ajardinadas como una estrategia para reducir la temperatura del aire y consumo de energía en los edificios, aunque este efecto puede ser limitado por la influencia de los vientos, la radiación y la especie seleccionada para el ajardinamiento, en especial de su LAD. Así mismo, en combinación con los bosques urbanos su efecto se potencia e incluso más si hay pavimentos húmedos o suelos porosos incluidos en la morfología del cañón urbano, convirtiéndose en una estrategia potencial para adaptar los ecosistemas urbanos el efecto aumento de temperatura derivado del cambio climático. En cuanto a la herramienta, ENVI-met se considera una buena opción para éste tipo de análisis dada su capacidad para reproducir de un modo muy cercano a la realidad el efecto de las cubiertas. Aparte de ser una herramienta validada en estudios anteriores, en el caso experimental se ha comprobado por medio de la comparación de las mediciones con los resultados del modelo. A su vez, los resultados y patrones de vientos generados en los cañones urbanos coinciden con otros estudios similares, concluyendo por tanto que es un software adecuado para el objeto de esta tesis doctoral. Como líneas de investigación futura, sería necesario entender el efecto de la cubierta ajardinada en el microclima urbano en diferentes zonas climáticas, así como un mayor estudio de otras variables que no se han observado en este análisis, como la temperatura media radiante y los indicadores de confort. Así mismo, la evaluación de otros parámetros que afectan el microclima urbano tales como variables geométricas y propiedades superficiales debería ser analizada en profundidad para tener un resultado que cubra todas las variables que afectan el microclima en el cañón urbano. ABSTRACT Climate Change is posing an urgency in the development of strategies able not only to mitigate but also adapt to the effects that this global problem is evidencing around the world. Heat waves, flooding and severe draughts increase the vulnerability of population, and this is especially critical in urban settlements. This has been extensively studied over the past decades, addressed from different perspectives and ranging from the regional heat island analysis to the building scale. Its understanding requires physical and dimensional analysis of this broad phenomenon and a deep analysis of the factors and the strategies which can offset it. In the search of solutions to this problem, green infrastructure elements such as green roofs, walls and urban forests arise as strategies able provide multiple regulating ecosystem services to the urban environment able to cope with climate change effects. This includes storm water management, heat island effect control, and improvement of air and water quality. Over the last decade, multiple studies have been developed to evaluate and quantify the ecosystem services provided by green roofs, however, specific regulating services addressing urban microclimate and their impact on the urban dwellers have not been widely quantified. This research tries to contribute to fill this gap and analyzes the effects of green roofs and urban forests on urban microclimate at pedestrian level, quantifying its potential for regulating ambient temperature in hot season in Mediterranean –continental climates. The study is divided into a sequence of analysis where the critical factors affecting the performance of the green roof system on the microclimate are identified and the effects of the green roof is tested in a real case study. The first step has been the definition of the object of study, through the analysis and review of theoretical and empirical papers that investigate the effects of covers landscaped in the built environment, in the context of its use as a tool for adaptation and mitigation of the impact of climate change on cities and urban development. This literature review, reveals the great potential of the plant systems as a tool for passive design capable of improving the climatic and microclimatic conditions in the cities, as well as its positive impact on the energy performance of buildings, but also the need for further analysis at the street scale where climate, urban surfaces and materials, and vegetation converge. This analysis requires a methodology where the thermal buildings response, the variations in the patterns of wind and the interaction of the vegetation are integrated, so a quantitative analysis can help to define the most effective strategies to achieve liveable urban spaces and collaterally, , the improvement of the surrounding buildings energy performance. In this specific scale research is needed and should be customized to every climate, urban condition and nature based strategy. In this context, the main objective for this research was the quantitative assessment of the Green roof impact on the urban microclimate at a neighbourhood scale in summer conditions in Mediterranean- continental climates. For the achievement of this main objective, the following secondary objectives have been set: • Identify the numerical models and calculation tools able to capture the effect of the roof garden on the microclimate. • Identify the enhancing or limiting parameter affecting this effect. • Quantification of the impact of the microclimate created on the energy consumption of buildings surrounding the street canyon analysed. The main hypothesis behind this research and where the above objectives are funded on is as follows: "An extensive roof installed in medium height buildings favours the establishment of microclimates at the pedestrian level and reduces the temperatures in the urban environment where they are located." For the purpose of verifying the above hypothesis and achieving the proposed objectives the following methodology has been followed: - Definition of hypothesis and objectives - Definition of the scope and limitations - Theoretical analysis of parameters affecting gren roof performance - Experimental analysis; - Energy modelling analyisis - Conclusions and future lines of work The search for suitable tools and models for meeting the objectives of this analysis has led to ENVI-met v4 as the most suitable software for this research. ENVI met is a three-dimensional micro-climate model designed to simulate the surface-plant-air interactions in urban environments. Based in the fundamental equations representing, mass, energy and momentum conservation, the software has the capacity of representing the complex phenomena characterizing the microclimate in urban canyons, overcoming the challenge posed by the computing requirements of a full calculus based on finite elements done via traditional computational fluid dynamics tools. Once the analysis tool has been defined, a first set of analysis has been developed to identify the main parameters affecting the green roof influence on the microclimate. In this analysis, two different scenarios are compared. A neighborhood with standard concrete tile roof and the same configuration substituting the concrete tile by an extensive green roof. Once the scenarios have been modeled, different iterations have been run to identify the influence of different wind patterns, solar exposure and roof vegetation type on the microclimate, since those are the most relevant variables affecting urban microclimates. These analysis have been run to check the conditions under which the effects of green roofs get significance. Since ENVI-met V4 is a predictive software, the first step has been the definition of the initial weather conditions which are then used as starting point by the software, which generates its own daily temperature and humidity profile based on the location of the building, geometry, vegetation and the surfaces physical characteristics. The base geometry used for this first analysis has been based on a typical urban layout structure located in Madrid, an orthogonal net with the main streets oriented East-West to ease the analysis of solar radiation in the different points of the model. This layout represents a typical urban neighborhood, with street canyons keeping an aspect ratio between 0.5 and 1 and high sky view factor to ensure correct sun access to the streets and buildings and work with typical wind flow patterns. Finally, the roof vegetation has been defined in terms of foliage density known as Leaf Area Density (LAD) and defined as the total one-sided leaf area per unit of layer volume. This index is the most relevant vegetation characteristic for the purpose of calculating the effect of vegetation on wind and solar radiation as well as the energy consumed during its metabolic processes. The building as usual (BAU) configuring the urban layout has been defined with standard concrete tile roofs, considering 0.3 albedo. Walls have been set with albedo 0.2 (typical brick wall construction) and adiabatic to avoid interference caused by thermal interchanges with the building indoor environment. For the proposed case, the same geometry and building characteristics have been kept. The only change is the roof surface coverage. The gravel on the roof has been changed with an extensive green roof covered with drought tolerant plants, typical in Madrid climate, and characterized by their LAD. The different scenarios analysed are based in the variation of the wind speed and the LAD of the roof. The results have been recorded under different sun exposure conditions. Simulations were run for the typical summer wind patterns, that for Madrid are characterized by South-west winds ranging from 3 to 0 m/s. Simulations were run for 3, 2, 1 and 0 m/s at urban canopy level. Results taken at 1.4 m above the ground showed that the green roof effect was lower with higher wind speeds and in any case the effect of the green roof on the air temperatures exceeded air temperature reductions higher than 1ºC. Relative humidity presented no variations when comparing the different scenarios. For the analysis at 0m/s, ENVI-met generated error and no results were obtained. Different simulations showed that under 0.5 m/s turbulence increased dramatically and the model became unstable and unable to produce reliable results. This is due to the turbulence model embedded in the software which is not valid for low wind speeds (below 1 m/s). The effect of the different foliage densities was also tested in the model. Three different alternatives were compared against the concrete roof: green roof with LAD 0.3 ( typical grass or sedum), 1.5 (typical mixed plants) and 2.5 (tree mass). The results showed very relevant temperature differences between the different LAD alternatives analyzed. Results show temperature variations ranging between 3 and 5 ºC when comparing the standard concrete roof with albedo 0, 3 with the vegetated roof and vegetated mass, showing the relevance of the LAD on the effects of green roofs on microclimate. This matches the data reported in existing literature and empirical studies and confirms the relevance of the LAD in the roof effect on the surrounding microclimate. The results of the theoretical analysis have reached the following initial conclusions related to both, the simulation tool and the model results: • In relation to the tool ENVI-met, some limitations for the analysis have been observed. In first place, the rigid structure of the geometry, the data bases and the grid size, limit the scale and resolution of the analysis not allowing the development of large urban areas. On the other hand the ENVI-met structure enables the development of this type of complex simulation within reasonable times and computational requirements for the purpose of this analysis. Additionally, the model is unable to run simulations at wind speeds lower than 0.5 m/s, and even at this speed, the results are not reliable because the turbulences generated by the model that made impossible to extract clear temperature differences between the concrete and green roof scenarios. Besides the above limitations, the wind patterns and temperature profiles generated by ENVImet are in agreement with previous analysis identifying wind patterns in urban canyons with similar characteristics and aspect ratio. Therefore the software has shown a good capacity for reproducing the wind effects in the street canyons and seems to capture the cooling effect produced by the green roof. • In relation to the model, the results reveals the influence of wind, radiation and LAD on air temperature in urban canyons with aspect ratio comprised between 0.5 and 1. Being the effect of the green roof more noticeable in shaded urban canyons with aspect ratio 1 and wind speeds of 1 m/s. In no case the reductions in air temperature exceeded 1ºC. Once the relevant parameters have been identified, mainly wind speed and LAD, an experimental analysis was conducted to test the results obtained by the model. For this purpose a large green roof was identified, able to represent the urban scale which is the object of the studio. The building identified for this purpose was the terminal 4, parking building of the international Madrid Airport. Even though this is not a standard urban area, the scale and configuration of the space around the building were deemed as acceptable for the analysis. The building is an 800x200 m, 15 m height parking building, surrounded by access paved paths and the terminal building. The parking is enclosed with facades that configure an urban canyon-like space, although the aspect ratio is lower than 0.5 and the wind patterns might differ from the theoretical model run. The building features the largest green roof in Europe, a 12 Ha extensive green roof populated with a mix of herbs and sedum with a LAD of 1.5. The buildings are surrounded by planted areas at the sidewalk and trees shading the main building facades. Green roof performance was evaluated by monitoring temperatures and relative humidity in the canyon in a typical summer day. The day selection was done taking into account meteorological predictions so the weather conditions on the measurement day were as close as possible as the optimal conditions identified in terms of green roof effects on the urban canyon. July 9th 2014 was selected for the measurement campaign because the predictions showed 1 m/s wind speed and sunny sky, which were very similar to the weather conditions where the effect of the green roof was most noticeable in the theory model. Measurements were registered hourly from 9:00am to 19:00 on July 9th 2014. Temperature, relative humidity and wind speed were recorded at 5 different levels, at 1.5, 4.5, 7.5, 11.5 and 16 m above ground and at 0.5 m distance from the building façade. Measurements were taken in three different scenarios, sunny exposure, shaded exposure, and shaded exposure influenced by nearby trees and moist soil. Temperature, relative humidity and wind speed were registered using a TESTO 410-2 anemometer, with 0.1ºC resolution for temperature, 0.1 m/s resolution for wind speed and 0.1 % for relative humidity. Surface temperatures were registered using an infrared camera FLIR E4, with temperature resolution 0.15ºC. Minimal distance to surface of 0.5 m and Tª measurements range from -20ºC and 250ºC. The temperature profiles measured on the site showed the influence of solar exposure on the temperature variations along the day, as well as the influence of the heat irradiated by the building surfaces which had been exposed to the sun radiation and those influenced by the moist soft areas around the building. After the measurements were taken, the following simulations were conducted to evaluate the impact of the green roof on the microclimate: a. Standard roof: T4 building assuming a concrete tile roof with albedo 0.3. b. Green roof: T4 building assuming an extensive green roof with low LAD value (0.5)-Simple Sedum roof. c. Green roof: T4 building assuming an extensive green roof with high LAD value 1.5- Lucerne and grasses d. Green roof plus street level vegetation: T4 Building, LAD 1.5 (Lucerne), including the existing trees at street level. This scenario represents the current conditions of the building. The urban canopy wind was set as 1 m/s, the wind speed register at that level during the measurement campaign. This wind speed remained constant over the whole campaign. Under the above conditions, the results of the models show a moderate effect of green roofs on the surrounding microclimate ranging from 1ºC to 2ºC, but a larger contribution when combining it with vegetation at pedestrian level, where 4ºC temperature reductions are reached. Relative humidity remained constant. Measured temperatures and relative humidity were compared to model results, showing a close match in the profiles defined in both cases and the good capacity of ENVI met to capture the impact of the green roof in this analysis. The largest differences were registered in the areas close to the top areas of the facades which were more exposed to sun radiation and also near to the soil level. These differences might be caused by differences between the materials properties included in the model (which were limited by the data available in the software database) and those in the real building. An important observation derived from this study is the contribution of moist soil to the green roof effect on air temperatures. In the green roof scenario with surrounding trees, the effect of the moist soil contributes to raise the temperature reductions at 4.5ºC. A final analysis was conducted after extracting the hourly temperature profile in the street canyon influenced by the effect of green roofs and trees. An energy model was run on the building assuming it was a conventional enclosed building. Energy demand reductions were registered in the building reaching up to 14% reductions at the peak hour. The main conclusion of this study is the potential of the green roofs as a strategy for reducing air temperatures and energy consumption in the buildings, although this effect can be limited by the influence of high speed winds. This effect can be enhanced its combination with urban forests and even more if soft moist pavements are included in the urban canyon morphology, becoming a potential strategy for adapting urban ecosystems to the increasing temperature effect derived from climate change.