1000 resultados para methodology


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thermoacoustic engines are energy conversion devices that convert thermal energy from a high-temperature heat source into useful work in the form of acoustic power while diverting waste heat into a cold sink; it can be used as a drive for cryocoolers and refrigerators. Though the devices are simple to fabricate, it is very challenging to design an optimized thermoacoustic primemover with better performance. The study presented here aims to optimize the thermoacoustic primemover using response surface methodology. The influence of stack position and its length, resonator length, plate thickness, and plate spacing on pressure amplitude and frequency in a thermoacoustic primemover is investigated in this study. For the desired frequency of 207 Hz, the optimized value of the above parameters suggested by the response surface methodology has been conducted experimentally, and simulations are also performed using DeltaEC. The experimental and simulation results showed similar output performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Given the increasing cost of designing and building new highway pavements, reliability analysis has become vital to ensure that a given pavement performs as expected in the field. Recognizing the importance of failure analysis to safety, reliability, performance, and economy, back analysis has been employed in various engineering applications to evaluate the inherent uncertainties of the design and analysis. The probabilistic back analysis method formulated on Bayes' theorem and solved using the Markov chain Monte Carlo simulation method with a Metropolis-Hastings algorithm has proved to be highly efficient to address this issue. It is also quite flexible and is applicable to any type of prior information. In this paper, this method has been used to back-analyze the parameters that influence the pavement life and to consider the uncertainty of the mechanistic-empirical pavement design model. The load-induced pavement structural responses (e.g., stresses, strains, and deflections) used to predict the pavement life are estimated using the response surface methodology model developed based on the results of linear elastic analysis. The failure criteria adopted for the analysis were based on the factor of safety (FOS), and the study was carried out for different sample sizes and jumping distributions to estimate the most robust posterior statistics. From the posterior statistics of the case considered, it was observed that after approximately 150 million standard axle load repetitions, the mean values of the pavement properties decrease as expected, with a significant decrease in the values of the elastic moduli of the expected layers. An analysis of the posterior statistics indicated that the parameters that contribute significantly to the pavement failure were the moduli of the base and surface layer, which is consistent with the findings from other studies. After the back analysis, the base modulus parameters show a significant decrease of 15.8% and the surface layer modulus a decrease of 3.12% in the mean value. The usefulness of the back analysis methodology is further highlighted by estimating the design parameters for specified values of the factor of safety. The analysis revealed that for the pavement section considered, a reliability of 89% and 94% can be achieved by adopting FOS values of 1.5 and 2, respectively. The methodology proposed can therefore be effectively used to identify the parameters that are critical to pavement failure in the design of pavements for specified levels of reliability. DOI: 10.1061/(ASCE)TE.1943-5436.0000455. (C) 2013 American Society of Civil Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thermoacoustic refrigerator (TAR) converts acoustic waves into heat without any moving parts. The study presented here aims to optimize the parameters like frequency, stack position, stack length, and plate spacing involving in designing TAR using the Response Surface Methodology (RSM). A mathematical model is developed using the RSM based on the results obtained from DeltaEC software. For desired temperature difference of 40 K, optimized parameters suggested by the RSM are the frequency 254 Hz, stack position 0.108 m, stack length 0.08 m, and plate spacing 0.0005 m. The experiments were conducted with optimized parameters and simulations were performed using the Design Environment for Low-amplitude ThermoAcoustic Energy Conversion (DeltaEC) which showed similar results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solder joints in electronic packages undergo thermo-mechanical cycling, resulting in nucleation of micro-cracks, especially at the solder/bond-pad interface, which may lead to fracture of the joints. The fracture toughness of a solder joint depends on material properties, process conditions and service history, as well as strain rate and mode-mixity. This paper reports on a methodology for determining the mixed-mode fracture toughness of solder joints with an interfacial starter-crack, using a modified compact mixed mode (CMM) specimen containing an adhesive joint. Expressions for stress intensity factor (K) and strain energy release rate (G) are developed, using a combination of experiments and finite element (FE) analysis. In this methodology, crack length dependent geometry factors to convert for the modified CMM sample are first obtained via the crack-tip opening displacement (CTOD)-based linear extrapolation method to calculate the under far-field mode I and II conditions (f(1a) and f(2a)), (ii) generation of a master-plot to determine a(c), and (iii) computation of K and G to analyze the fracture behavior of joints. The developed methodology was verified using J-integral calculations, and was also used to calculate experimental fracture toughness values of a few lead-free solder-Cu joints. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A comprehensive design flow is proposed for the design of Micro Electro Mechanical Systems that are fabricated using SOIMUMPs process. Many of the designers typically do not model the temperature dependency of electrical conductivity, thermal conductivity and convection coefficient, as it is very cumbersome to create/incorporate the same in the existing FEM simulators. Capturing these dependencies is very critical particularly for structures that are electrically actuated. Lookup tables that capture the temperature dependency of electrical conductivity, thermal conductivity and convection coefficient are created. These look up tables are taken as inputs for a commercially available FEM simulator to model the semiconductor behavior. It is demonstrated that when temperature dependency for all the above mentioned parameters is not captured, then the error in estimation of the maximum temperature (for a given structure) could be as high as 30%. Error in the estimated resistance value under the same conditions is as high as 40%. When temperature dependency of the above mentioned parameters is considered then error w.r.t the measured values is less than 5%. It is evident that error in temperature estimates leads to erroneous results from mechanical simulations as well.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experimental data on evaporation of droplets of decane, Jet-A1, and Jet-A1 surrogate are generated using a spray in crossflow configuration. The advantage of a crossflow configuration is that it enables us to study droplet evaporation under forced convective conditions involving droplet diameters of size relevant in practical combustors. Specifically, spray from an airblast atomizer is injected into a preheated crossflow of air and the resulting spray is characterized in terms of spray structure along with droplet size and velocity. An existing correlation for the spray trajectory is modified to incorporate the effect of elevated temperature, and is found to be in good agreement with the experimental data. Droplet sizes and velocities are measured at different locations along the crossflow direction to assess droplet evaporation. Specifically, droplets having size less than 25-mu m are selected for further analysis since these droplets are observed to exhibit velocities which are aligned with the crossflow. By comparing the droplet diameter profiles at upstream and downstream locations, the evaporation constant k for the d(2)-law is obtained iteratively. To assess the efficacy of the values of k obtained, the calculated droplet size distribution using the proposed k values at the downstream location is compared with the measured droplet size distribution at that location. A reasonably good match is found for all the three liquids confirming the validity of the analysis. (C) 2015 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Impreso por la Diputación Foral de Álava, D.L. VI-430/99.