967 resultados para measuring instruments


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A sampling and analytical system has been developed for shipboard measurements of high-resolution vertical profiles of the marine trace gas dimethylsulfide (DMS). The system consists of a tube attached to a CTD with a peristaltic pump on deck that delivers seawater to a membrane equilibrator and atmospheric pressure chemical ionization mass spectrometer (Eq-APCIMS). This allows profiling DMS concentrations to a depth of 50 m, with a depth resolution of 1.3-2 m and a detection limit of nearly 0.1 nmol L-1. The seawater is also plumbed to allow parallel operation of additional continuous instruments, and simultaneous collection of discrete samples for complementary analyses. A valve alternates delivery of seawater from the vertical profiler and the ship�s underway intake, thereby providing high-resolution measurements in both the vertical and horizontal dimensions. Tests conducted on various cruises in the Mediterranean Sea, Atlantic, Indian, and Pacific Oceans show good agreement between the Eq-APCIMS measurements and purge and trap gas chromatography with flame photometric detection (GC-FPD) and demonstrate that the delivery of seawater from the underway pump did not significantly affect endogenous DMS concentrations. Combination of the continuous flow DMS analysis with high-frequency hydrographic, optical, biological and meteorological measurements will greatly improve the spatial/temporal resolution of seagoing measurements and improve our understanding of DMS cycling.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives—To inform researchers and clinicians about the most appropriate generic and disease specific measures of health related quality of life for use among people with ischaemic heart disease. Methods—MEDLINE and BIDS were searched for research papers which contained a report of at least one of the three most common generic instruments or at least one of the five disease specific instruments used with ischaemic heart disease patients. Evidence for the validity, reliability, and sensitivity of these instruments was critically appraised. Results—Of the three generic measures—the Nottingham health profile, sickness impact profile, and short form 36 (SF-36)—the SF-36 appears to offer the most reliable, valid, and sensitive assessment of quality of life. However, a few of the SF-36 subscales lack a sufficient degree of sensitivity to detect change in a patient’s clinical condition. According to the best available evidence, the quality of life after myocardial infarction questionnaire should be preferred to the Seattle angina questionnaire, the quality of life index cardiac version, the angina pectoris quality of life questionnaire, and the summary index. Overall, research on disease specific measures is sparse compared to the number of studies which have investigated generic measures. Conclusions—An assessment of the quality of life of people with ischaemic heart disease should comprise a disease specific measure in addition to a generic measure. The SF-36 and the quality of life after myocardial infarction questionnaire (version 2) are the most appropriate currently available generic and disease specific measures of health related quality of life, respectively. Further research into the measurement of health related quality of life of people with ischaemic heart disease is required in order to address the problems (such as lack of sensitivity to detect change) identified by the review.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Increasing emphasis is being placed on the evaluation of health-related quality of life. However, there is no consensus on the definition of this concept and as a result there are a plethora of existing measurement instruments. Head-to-head comparisons of the psychometric properties of existing instruments are necessary to facilitate evidence-based decisions about which instrument should be chosen for routine use. Therefore, an individualised instrument (the modified Patient Generated Index), a generic instrument (the Short Form 36) and a disease-specific instrument (the Quality of Life after Myocardial Infarction questionnaire) were administered to patients with ischaemic heart disease (n=117) and the evidence for the validity, reliability and sensitivity of each instrument was examined and compared. The modified Patient Generated Index compared favourably with the other instruments but none of the instruments examined provided sound evidence for sensitivity to change. Therefore, any recommendation for the use of the individualised approach in the routine collection of health-related quality of life data in clinical practice must be conditional upon the submission of further evidence to support the sensitivity of such instruments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report on a study comparing absolute K-alpha yield from Ti foils measured with a calibrated system of an X-ray CCD coupled to a curved LiF Von-Hamos crystal spectrometer to the difference in the signals measured simultaneously with two similar photodiodes fitted with two different filters. Our data indicate that a combination of photodiodes with different filters could be developed into an alternative and inexpensive diagnostic for monitoring single shot pulsed emission in a narrow band of X-ray region.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Measures of icon designs rely heavily on surveys of the perceptions of population samples. Thus, measuring the extent to which changes in the structure of an icon will alter its perceived complexity can be costly and slow. An automated system capable of producing reliable estimates of perceived complexity could reduce development costs and time. Measures of icon complexity developed by Garcia, Badre, and Stasko (1994) and McDougall, Curry, and de Bruijn (1999) were correlated with six icon properties measured using Matlab (MathWorks, 2001) software, which uses image-processing techniques to measure icon properties. The six icon properties measured were icon foreground, the number of objects in an icon, the number of holes in those objects, and two calculations of icon edges and homogeneity in icon structure. The strongest correlates with human judgments of perceived icon complexity (McDougall et al., 1999) were structural variability (r(s) = .65) and edge information (r(s) =.64).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Multiplexed immunochemical detection platforms offer the potential to decrease labour demands, increase sample throughput and decrease overall time to result. A prototype four channel multiplexed high throughput surface plasmon resonance biosensor was previously developed, for the detection of food related contaminants. A study focused on determining the instruments performance characteristics was undertaken. This was followed by the development of a multiplexed assay for four high molecular weight proteins. The protein levels were simultaneously evaluated in serum samples of 10-week-old veal calves (n = 24) using multiple sample preparation methods. Each of the biosensor's four channels were shown to be independent of one another and produced multiplexed within run repeatability (n = 6) ranging from 2.0 to 6.7%CV, for the four tested proteins, whilst between run reproducibility (n = 4) ranged from 1.5 to 8.9%CV. Four calibration curves were successfully constructed before serum sample preparation was optimised for each protein. Multiplexed concentration analysis was successfully performed on four channels revealing that each proteins concentration was consistent across the twenty-four tested animals. Signal reproducibility (n > 19) on a further long term study revealed coefficient of variation ranging from 1.1% to 7.3% and showed that the multiplexed assay was stable for at least 480 cycles. These findings indicate that the performance characteristics fall within the range of previously published data for singleplex optical biosensors and that the multiplexing biosensor is fit-for-purpose for simultaneous concentration analysis in many different types of applications such as the multiplexed detection of markers of growth-promoter abuse and multiplexed detection of residues of concern in food safety. © 2013 Elsevier B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new method of measuring the total conductivity of atmospheric air is described. It depends on determination of the electrical relaxation time of a horizontal wire, mounted between two insulators, which is initially grounded and then allowed to charge freely. The total air conductivity derived is compared with that from an ion mobility spectrometer. Results from the two techniques agreed to within 1.2 fS m(-1). (c) 2006 American Institute of Physics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the summer 2000 EXPORT aircraft campaign (European eXport of Precursors and Ozone by long-Range Transport), two comprehensively instrumented research aircraft measuring a variety of chemical species flew wing tip to wing tip for a period of one and a quarter hours. During this interval a comparison was undertaken of the measurements of nitrogen oxide (NO), odd nitrogen species (NOy), carbon monoxide (CO) and ozone (O3). The comparison was performed at two different flight levels, which provided a 10-fold variation in the concentrations of both NO (10 to 1000 parts per trillion by volume (pptv)) and NOy (200 to over 2500 pptv). Large peaks of NO and NOy observed from the Falcon 20, which were at first thought to be from the exhaust of the C-130, were also detected on the 4 channel NOxy instrument aboard the C-130. These peaks were a good indication that both aircraft were in the same air mass and that the Falcon 20 was not in the exhaust plume of the C-130. Correlations and statistical analysis are presented between the instruments used on the two separate aircraft platforms. These were found to be in good agreement giving a high degree of correlation for the ambient air studied. Any deviations from the correlations are accounted for in the estimated inaccuracies of the instruments. These results help to establish that the instruments aboard the separate aircraft are reliably able to measure the corresponding chemical species in the range of conditions sampled and that data collected by both aircraft can be co-ordinated for purposes of interpretation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: Community-based care for mental disorders places considerable burden on families and carers. Measuring their experiences has become a priority, but there is no consensus on appropriate instruments. We aimed to review instruments carers consider relevant to their needs and assess evidence for their use. Method: A literature search was conducted for outcome measures used with mental health carers. Identified instruments were assessed for their relevance to the outcomes identified by carers and their psychometric properties. Results: Three hundred and ninety two published articles referring to 241 outcome measures were identified, 64 of which were eligible for review (used in three or more studies). Twenty-six instruments had good psychometric properties; they measured (i) carers' well-being, (ii) the experience of caregiving and (iii) carers' needs for professional support. Conclusion: Measures exist which have been used to assess the most salient aspects of carer outcome in mental health. All require further work to establish their psychometric properties fully.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A weather balloon and its suspended instrument package behave like a pendulum with a moving pivot. This dynamical system is exploited here for the detection of atmospheric turbulence. By adding an accelerometer to the instrument package, the size of the swings induced by atmospheric turbulence can be measured. In test flights, strong turbulence has induced accelerations greater than 5g, where g = 9.81 m s−2. Calibration of the accelerometer data with a vertically orientated lidar has allowed eddy dissipation rate values of between 10−3 and 10−2 m2 s−3 to be derived from the accelerometer data. The novel use of a whole weather balloon and its adapted instrument package can be used as a new instrument to make standardized in situ measurements of turbulence.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

When a multilayered material is analyzed by means of energy-dispersive X-ray fluorescence analysis, then the X-ray ratios of K alpha/K beta, or L alpha/L beta and L alpha/L gamma, for an element in the multilayered material, depend on the composition and thickness of the layer in which the element is situated, and on the composition and thickness of the superimposed layer (or layers). Multilayered samples are common in archaeometry, for example, in the case of pigment layers in paintings, or in the case of gilded or silvered alloys. The latter situation is examined in detail in the present paper, with a specific reference to pre-Columbian alloys from various museums in the north of Peru. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel method is proposed for measuring the hysteresis loops of ferroelectric polymers. The samples need to have only one electrode and are poled by corona discharge in a constant current corona triode. It is shown how the sample surface potential and the charging current are related to the remanent polarization and coercive field, so that the hysteresis loops can be obtained. An illustrative example is given for samples of beta-PVDF for which the hysteresis cycles were remarkably close to those obtained with the traditional Sawyer-Tower circuit. Values of 80 MV/m and 70 mC/m2 were estimated for the coercive field and remanent polarization, respectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated the effect of item inversion on the construct validity and reliability of psychometric scales and proposed a theoretical framework for the evaluation of the psychometric properties of data gathered with psychometric instruments. To this propose, we used the Maslach Burnout Inventory, which is the most used psychometric inventory to measure burnout in different professional context (Students, Teachers, Police, Doctors, Nurses, etc…). The version of the MBI used was the MBI-Student Survey (MBI-SS). This inventory is composed of three key dimensions: Exhaustion, Cynicism and Professional Efficacy. The two first dimensions—which have positive formulated items—are moderate to strong positive correlated, and show moderate to strong negative correlations with the 3rd dimension—which has negative formulated items. We tested the hypothesis that, in college students, formulating the 3rd dimension of burnout as Inefficacy (reverting the negatively worded items in the Efficacy dimension) improves the correlation of the 3rd dimension with the other two dimensions, improves its internal consistency, and the overall MBI-SS’ construct validity and reliability. Confirmatory factor analysis results, estimated by Maximum Likelihood, revealed adequate factorial fit for both forms of the MBI-SS (with Efficacy) vs. the MBI-SSi (with Inefficacy). Also both forms showed adequate convergent and discriminant related validity. However, reliability and convergent validity were higher for the MBI-SSi. There were also stronger (positive) correlations between the 3 factors in MBI-SSi than the ones observed in MBI-SS. Results show that positively rewording of the 3rd dimension of the MBI-SS improves its validity and reliability. We therefore propose that the 3rd dimension of the MBI-SS should be named Professional Inefficacy and its items should be positively worded.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Research into information quality on the internet, in particular on websites, has become increasingly important in recent years. In this paper a research project is described in which a measurement instrument was developed that enables the information quality of websites to be determined and analyzed from the customer perspective. The measurement instrument was developed in several stages and on the basis of a methodical-theoretical approach. In a first step, previous research results and measurement instruments were systematically analyzed. In a second step, these results were adjusted and supplemented on the basis of a qualitative study. A quantitative test of the measurement instrument is planned.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Intensive Family Preservation Services seek to reflect the values of focusing on client strengths and viewing clients as colleagues. To promote those values, Intensive Family Preservation Programs should include a systematic form of client self monitoring in their packages of outcome measures. This paper presents a model of idiographic self-monitoring used in time series, single system research design developed for Family Partners, a family preservation program of the School for Contemporary Education in Annandale, Virginia. The evaluation model provides a means of empowering client families to utilize their strengths and promote their status as colleague in determining their own goals, participating in the change process, and measuring their own progress.