976 resultados para measurement technology
Resumo:
Phosphorus is an essential element for plants and animals, playing a fundamental role in the production of biochemical energy. Despite its relevance, phosphorus is not commonly determined by instrumental neutron activation analysis (INAA), because (32)P does not emit gamma-rays in its decay. There are alternative methods for the determination of phosphorus by INAA, such as the use of beta counting or the measurement of bremsstrahlung originated from the high energy beta particle from (32)P. Here the determination of phosphorus in plant materials by measuring the bremsstrahlung production was further investigated, to optimize an analytical protocol for minimizing interferences and overcoming the poor specificity. Eight certified reference materials of plant matrices with phosphorus ranging between 171 and 5,180 mg kg(-1) were irradiated at a thermal neutron flux of 9.5 x 10(12) cm(-2) s(-1) and measured with a HPGe detector at decay times varying from 7 to 60 days. Phosphorus solutions added to a certified reference material at three levels were used for calibration. Counts accumulated in the baseline at four different regions of the gamma-ray spectra were tested for the determination of phosphorus, with better results for the 100 keV region. The Compton scattering contribution in the selected range was discounted using an experimental peak-to-Compton factor and the net areas of all peaks in the spectra with energies higher than 218 keV, i.e. Compton edge above 100 keV. Amongst the interferences investigated, the production of (32)P from sulfur, and the contribution of Compton scattering should be considered for producing good results.
Resumo:
The differential production cross section of electrons from semileptonic heavy-flavor hadron decays has been measured at midrapidity (\y\ < 0.5) in proton-proton collisions at root s = 7 TeV with ALICE at the LHC. Electrons were measured in the transverse momentum range 0.5 < p(t) < 8 GeV/c. Predictions from a fixed-order perturbative QCD calculation with next-to-leading-log resummation agree with the data within the theoretical and experimental uncertainties. DOI: 10.1103/PhysRevD.86.112007
Resumo:
In this study, the measurement of the concentration and size of particles and the identification of their sources were carried out at five orthopedic surgeries. The aerosol concentration and particle size distribution, ranging from 0.3 mu m 10 mu m, were measured and related to the type of indoor activity. The handling of surgical linen and gowns, handling of the patient, use of electrosurgical apparatus, use of a bone saw, handling of equipment, and cleaning of the room were identified as the most important sources of particles, with each of these activities posing different risks to the health of the patients and workers. The results showed that most of the particles were above 0.5 mu m and that there was a strong correlation among all particles of sizes above 1 mu m. Particles with diameters in the range of 0.3 mu m-0.5 mu m had a good correlation only with particles in the ranges of 0.5 mu m-1.0 mu m and 1.0 mu m-3.0 mu m in three of the surgeries analyzed. Findings led to the conclusion that most of the events responsible for generating aerosol particles in an orthopedic surgery room are brief, intermittent, and highly variable, thus requiring the use of specific instrumentation for their continuous identification and characterization.
Resumo:
We report the measurement of direct photons at midrapidity in Au + Au collisions at root s(NN) = 200 GeV. The direct photon signal was extracted for the transverse momentum range of 4 GeV/c < pT < 22 GeV/c, using a statistical method to subtract decay photons from the inclusive photon sample. The direct photon nuclear modification factor R-AA was calculated as a function of p(T) for different Au + Au collision centralities using the measured p + p direct photon spectrum and compared to theoretical predictions. R-AA was found to be consistent with unity for all centralities over the entire measured pT range. Theoretical models that account for modifications of initial direct photon production due to modified parton distribution functions in Au and the different isospin composition of the nuclei predict a modest change of R-AA from unity. They are consistent with the data. Models with compensating effects of the quark-gluon plasma on high-energy photons, such as suppression of jet-fragmentation photons and induced-photon bremsstrahlung from partons traversing the medium, are also consistent with this measurement.
Resumo:
The effect of event background fluctuations on charged particle jet reconstruction in Pb-Pb collisions at root s(NN) = 2.76 TeV has been measured with the ALICE experiment. The main sources of non-statistical fluctuations are characterized based purely on experimental data with an unbiased method, as well as by using single high p(t) particles and simulated jets embedded into real Pb-Pb events and reconstructed with the anti-k(t) jet finder. The influence of a low transverse momentum cut-off on particles used in the jet reconstruction is quantified by varying the minimum track p(t) between 0.15 GeV/c and 2 GeV/c. For embedded jets reconstructed from charged particles with p(t) > 0.15 GeV/c, the uncertainty in the reconstructed jet transverse momentum due to the heavy-ion background is measured to be 11.3 GeV/c (standard deviation) for the 10% most central Pb-Pb collisions, slightly larger than the value of 11.0 GeV/c measured using the unbiased method. For a higher particle transverse momentum threshold of 2 GeV/c, which will generate a stronger bias towards hard fragmentation in the jet finding process, the standard deviation of the fluctuations in the reconstructed jet transverse momentum is reduced to 4.8-5.0 GeV/c for the 10% most central events. A non-Gaussian tail of the momentum uncertainty is observed and its impact on the reconstructed jet spectrum is evaluated for varying particle momentum thresholds, by folding the measured fluctuations with steeply falling spectra.
Resumo:
The ALICE experiment at the LHC has studied J/psi production at mid-rapidity in pp collisions at root s = 7 TeV through its electron pair decay on a data sample corresponding to an integrated luminosity L-int = 5.6 nb(-1). The fraction of J/psi from the decay of long-lived beauty hadrons was determined for J/psi candidates with transverse momentum p(t) > 1,3 GeV/c and rapidity vertical bar y vertical bar < 0.9. The cross section for prompt J/psi mesons, i.e. directly produced J/psi and prompt decays of heavier charmonium states such as the psi(2S) and chi(c) resonances, is sigma(prompt J/psi) (p(t) > 1.3 GeV/c, vertical bar y vertical bar < 0.9) = 8.3 +/- 0.8(stat.) +/- 1.1 (syst.)(-1.4)(+1.5) (syst. pol.) mu b. The cross section for the production of b-hadrons decaying to J/psi with p(t) > 1.3 GeV/c and vertical bar y vertical bar < 0.9 is a sigma(J/psi <- hB) (p(t) > 1.3 GeV/c, vertical bar y vertical bar < 0.9) = 1.46 +/- 0.38 (stat.)(-0.32)(+0.26) (syst.) mu b. The results are compared to QCD model predictions. The shape of the p(t) and y distributions of b-quarks predicted by perturbative QCD model calculations are used to extrapolate the measured cross section to derive the b (b) over bar pair total cross section and d sigma/dy at mid-rapidity.
Resumo:
We report a measurement of the proton-air cross section for particle production at the center-of-mass energy per nucleon of 57 TeV. This is derived from the distribution of the depths of shower maxima observed with the Pierre Auger Observatory: systematic uncertainties are studied in detail. Analyzing the tail of the distribution of the shower maxima, a proton-air cross section of [505 +/- 22(stat)(-36)(+28)(syst)] mb is found.
Resumo:
Abstract Background Spotted cDNA microarrays generally employ co-hybridization of fluorescently-labeled RNA targets to produce gene expression ratios for subsequent analysis. Direct comparison of two RNA samples in the same microarray provides the highest level of accuracy; however, due to the number of combinatorial pair-wise comparisons, the direct method is impractical for studies including large number of individual samples (e.g., tumor classification studies). For such studies, indirect comparisons using a common reference standard have been the preferred method. Here we evaluated the precision and accuracy of reconstructed ratios from three indirect methods relative to ratios obtained from direct hybridizations, herein considered as the gold-standard. Results We performed hybridizations using a fixed amount of Cy3-labeled reference oligonucleotide (RefOligo) against distinct Cy5-labeled targets from prostate, breast and kidney tumor samples. Reconstructed ratios between all tissue pairs were derived from ratios between each tissue sample and RefOligo. Reconstructed ratios were compared to (i) ratios obtained in parallel from direct pair-wise hybridizations of tissue samples, and to (ii) reconstructed ratios derived from hybridization of each tissue against a reference RNA pool (RefPool). To evaluate the effect of the external references, reconstructed ratios were also calculated directly from intensity values of single-channel (One-Color) measurements derived from tissue sample data collected in the RefOligo experiments. We show that the average coefficient of variation of ratios between intra- and inter-slide replicates derived from RefOligo, RefPool and One-Color were similar and 2 to 4-fold higher than ratios obtained in direct hybridizations. Correlation coefficients calculated for all three tissue comparisons were also similar. In addition, the performance of all indirect methods in terms of their robustness to identify genes deemed as differentially expressed based on direct hybridizations, as well as false-positive and false-negative rates, were found to be comparable. Conclusion RefOligo produces ratios as precise and accurate as ratios reconstructed from a RNA pool, thus representing a reliable alternative in reference-based hybridization experiments. In addition, One-Color measurements alone can reconstruct expression ratios without loss in precision or accuracy. We conclude that both methods are adequate options in large-scale projects where the amount of a common reference RNA pool is usually restrictive.
Resumo:
Intangible resources have raised the interests of scholars from different research areas due to their importance as crucial factors for firm performance; yet, contributions to this field still lack a theoretical framework. This research analyses the state-of-the-art results reached in the literature concerning intangibles, their main features and evaluation problems and models. In search for a possible theoretical framework, the research draws a kind of indirect analysis of intangibles through the theories of the firm, their critic and developments. The heterodox approaches of the evolutionary theory and resource-based view are indicated as possible frameworks. Based on this theoretical analysis, organization capital (OC) is identified, for its features, as the most important intangible for firm performance. Empirical studies on the relationship intangibles-firm performance have been sporadic and have failed to reach firm conclusions with respect to OC; in the attempt to fill this gap, the effect of OC is tested on a large sample of European firms using the Compustat Global database. OC is proxied by capitalizing an income statement item (Selling, General and Administrative expenses) that includes expenses linked to information technology, business process design, reputation enhancement and employee training. This measure of OC is employed in a cross-sectional estimation of a firm level production function - modeled with different functional specifications (Cobb-Douglas and Translog) - that measures OC contribution to firm output and profitability. Results are robust and confirm the importance of OC for firm performance.
Resumo:
Introduction. Glycomic analysis allows investigating on the global glycome within body fluids (as serum/plasma), this could eventually lead to identify new types of disease biomarkers, or as in this study, biomarkers of human aging studying specific aging models. Recent studies demonstrated that the plasma N-glycome is modified during human aging, suggesting that measurements of log-ratio of two serum/plasma N-glycans (NGA2F and NA2F), named GlycoAge test could provide a non-invasive biomarker of aging. Down syndrome (DS) is a genetic disorder in which multiple major aspects of senescent phenotype occur much earlier than in healthy age-matched subjects and has been often defined as an accelerated aging syndrome. The aim of this study was to compare plasma N-glycome of patients affected by DS with age- and sex matched non-affected controls, represented by their siblings (DSS), in order to assess if DS is characterized by a specific N-glycomic pattern. Therefore, in order to investigate if N-glycans changes that occur in DS were able to reveal an accelerated aging in DS patients, we enrolled the mothers (DSM) of the DS and DSS, representing the non-affected control group with a different chronological age respect to DS. We applied two different N-glycomics approaches on the same samples: first, in order to study the complete plasma N-glycome we applied a new high-sensitive protocol based on a MALDI-TOF-MS approach, second, we used DSA-FACE technology. Results: MALDI-TOF/MS analysis detected a specific N-glycomics signature for DS, characterized by an increase of fucosylated and bisecting species. Moreover, in DS the abundance of agalactosylated (as NA2F) species was similar or higher than their mothers. The measurement of GlycoAge test with DSA-FACE, validated also by MALDI-TOF, demonstrated a strongly association with age, moreover in DS, it’s value was similar to their mothers, and significantly higher than their age- and sex matched not-affected siblings
Resumo:
SMARTDIAB is a platform designed to support the monitoring, management, and treatment of patients with type 1 diabetes mellitus (T1DM), by combining state-of-the-art approaches in the fields of database (DB) technologies, communications, simulation algorithms, and data mining. SMARTDIAB consists mainly of two units: 1) the patient unit (PU); and 2) the patient management unit (PMU), which communicate with each other for data exchange. The PMU can be accessed by the PU through the internet using devices, such as PCs/laptops with direct internet access or mobile phones via a Wi-Fi/General Packet Radio Service access network. The PU consists of an insulin pump for subcutaneous insulin infusion to the patient and a continuous glucose measurement system. The aforementioned devices running a user-friendly application gather patient's related information and transmit it to the PMU. The PMU consists of a diabetes data management system (DDMS), a decision support system (DSS) that provides risk assessment for long-term diabetes complications, and an insulin infusion advisory system (IIAS), which reside on a Web server. The DDMS can be accessed from both medical personnel and patients, with appropriate security access rights and front-end interfaces. The DDMS, apart from being used for data storage/retrieval, provides also advanced tools for the intelligent processing of the patient's data, supporting the physician in decision making, regarding the patient's treatment. The IIAS is used to close the loop between the insulin pump and the continuous glucose monitoring system, by providing the pump with the appropriate insulin infusion rate in order to keep the patient's glucose levels within predefined limits. The pilot version of the SMARTDIAB has already been implemented, while the platform's evaluation in clinical environment is being in progress.
Resumo:
The 1s-2s interval has been measured in the muonium (;mgr;(+)e(-)) atom by Doppler-free two-photon pulsed laser spectroscopy. The frequency separation of the states was determined to be 2 455 528 941.0(9.8) MHz, in good agreement with quantum electrodynamics. The result may be interpreted as a measurement of the muon-electron charge ratio as -1-1.1(2.1)x10(-9). We expect significantly higher accuracy at future high flux muon sources and from cw laser technology.
Resumo:
This work presents an innovative integration of sensing and nano-scaled fluidic actuation in the combination of pH sensitive optical dye immobilization with the electro-osmotic phenomena in polar solvents like water for flow-through pH measurements. These flow-through measurements are performed in a flow-through sensing device (FTSD) configuration that is designed and fabricated at MTU. A relatively novel and interesting material, through-wafer mesoporous silica substrates with pore diameters of 20 -200 nm and pore depths of 500 µm are fabricated and implemented for electro-osmotic pumping and flow-through fluorescence sensing for the first time. Performance characteristics of macroporous silicon (> 500 µm) implemented for electro-osmotic pumping include, a very large flow effciency of 19.8 µLmin-1V-1 cm-2 and maximum pressure effciency of 86.6 Pa/V in comparison to mesoporous silica membranes with 2.8 µLmin-1V-1cm-2 flow effciency and a 92 Pa/V pressure effciency. The electrical current (I) of the EOP system for 60 V applied voltage utilizing macroporous silicon membranes is 1.02 x 10-6A with a power consumption of 61.74 x 10-6 watts. Optical measurements on mesoporous silica are performed spectroscopically from 300 nm to 1000 nm using ellipsometry, which includes, angularly resolved transmission and angularly resolved reflection measurements that extend into the infrared regime. Refractive index (n) values for oxidized and un-oxidized mesoporous silicon sample at 1000 nm are found to be 1.36 and 1.66. Fluorescence results and characterization confirm the successful pH measurement from ratiometric techniques. The sensitivity measured for fluorescein in buffer solution is 0.51 a.u./pH compared to sensitivity of ~ 0.2 a.u./pH in the case of fluorescein in porous silica template. Porous silica membranes are efficient templates for immobilization of optical dyes and represent a promising method to increase sensitivity for small variations in chemical properties. The FTSD represents a device topology suitable for application to long term monitoring of lakes and reservoirs. Unique and important contributions from this work include fabrication of a through-wafer mesoporous silica membrane that has been thoroughly characterized optically using ellipsometry. Mesoporous silica membranes are tested as a porous media in an electro-osmotic pump for generating high pressure capacities due to the nanometer pore sizes of the porous media. Further, dye immobilized mesoporous silica membranes along with macroporous silicon substrates are implemented for continuous pH measurements using fluorescence changes in a flow-through sensing device configuration. This novel integration and demonstration is completely based on silicon and implemented for the first time and can lead to miniaturized flow-through sensing systems based on MEMS technologies.
Resumo:
Fuel Cells are a promising alternative energy technology. One of the biggest problems that exists in fuel cell is that of water management. A better understanding of wettability characteristics in the fuel cells is needed to alleviate the problem of water management. Contact angle data on gas diffusion layers (GDL) of the fuel cells can be used to characterize the wettability of GDL in fuel cells. A contact angle measurement program has been developed to measure the contact angle of sessile drops from drop images. Digitization of drop images induces pixel errors in the contact angle measurement process. The resulting uncertainty in contact angle measurement has been analyzed. An experimental apparatus has been developed for contact angle measurements at different temperature, with the feature to measure advancing and receding contact angles on gas diffusion layers of fuel cells.