909 resultados para intrauterine device


Relevância:

20.00% 20.00%

Publicador:

Resumo:

El projecte es va fer al KHLim a Diepenbeek. Es tractava de dissenyar un nou dispositiu de localització d'avaries del relè del motor, per tal de de substituir el que ja hi havia, per raons de seguretat

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Home blood pressure (BP) monitoring is recommended by several clinical guidelines and has been shown to be feasible in elderly persons. Wrist manometers have recently been proposed for such home BP measurement, but their accuracy has not been previously assessed in elderly patients. METHODS: Forty-eight participants (33 women and 15 men, mean age 81.3±8.0 years) had their BP measured with a wrist device with position sensor and an arm device in random order in a sitting position. RESULTS: Average BP measurements were consistently lower with the wrist than arm device for systolic BP (120.1±2.2 vs. 130.5±2.2 mmHg, P<0.001, means±SD) and diastolic BP (66.0±1.3 vs. 69.7±1.3 mmHg, P<0.001). Moreover, a 10 mmHg or greater difference between the arm and wrist device was observed in 54.2 and 18.8% of systolic and diastolic measures, respectively. CONCLUSION: Compared with the arm device, the wrist device with position sensor systematically underestimated systolic as well as diastolic BP. The magnitude of the difference is clinically significant and questions the use of the wrist device to monitor BP in elderly persons. This study points to the need to validate BP measuring devices in all age groups, including in elderly persons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To the Editor: The value of angiotensin-converting– enzyme (ACE) inhibitors, beta-blockers, and spironolactone has been well established by the results of numerous clinical trials. About 70 percent of the patients described by Rose et al. were treated with ACE inhibitors or angiotensin II–receptor antagonists; 35 to 40 percent received spironolactone, and only about 20 percent received beta-blockers. Thus, this population cannot have been considered to be optimally treated from the point of view of medical therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Most ventricular assist devices (VADs) currently used in infants are extracorporeal. These VADs require long-term anticoagulation therapy and extensive surgery, and two devices are needed for biventricular support. We designed a biventricular assist device based on shape memory alloy that reproduces the hemodynamic effects of cardiomyoplasty, supporting the heart with a compressing movement, and evaluated its performance in a dedicated mockup system. Nitinol fibers are the device's key component. Ejection fraction (EF), cardiac output (CO), and generated systolic pressure were measured on a test bench. Our test bench settings were a preload range of 0-15 mm Hg, an afterload range of 0-160 mm Hg, and a heart rate (HR) of 20, 30, 40, and 60 beats/min. A power supply of 15 volts and 3.5 amperes was necessary. The EF range went from 34.4% to 1.2% as the afterload and HR increased, along with a CO from 180 to 6 ml/min. The device generated a maximal systolic pressure of 25 mm Hg. Cardiac compression for biventricular assistance in child-sized heart using shape memory alloy is technically feasible. Further testing remains necessary to assess this VAD's in vivo performance range and its reliability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To identify specific major congenital malformations associated with use of carbamazepine in the first trimester of pregnancy. DESIGN: A review of all published cohort studies to identify key indications and a population based case-control study to test these indications. SETTING: Review of PubMed, Web of Science, and Embase for papers about carbamazepine exposure in the first trimester of pregnancy and specific malformations, and the EUROCAT Antiepileptic Study Database, including data from 19 European population based congenital anomaly registries, 1995-2005. PARTICIPANTS: The literature review covered eight cohort studies of 2680 pregnancies with carbamazepine monotherapy exposure, and the EUROCAT dataset included 98 075 registrations of malformations covering over 3.8 million births. MAIN OUTCOME MEASURES: Overall prevalence for a major congenital malformation after exposure to carbamazepine monotherapy in the first trimester. Odds ratios for malformations with exposure to carbamazepine among cases (five types of malformation identified in the literature review) compared with two groups of controls: other non-chromosomal registrations of malformations and chromosomal syndromes. RESULTS: The literature review yielded an overall prevalence for a major congenital malformation of 3.3% (95% confidence interval 2.7 to 4.2) after exposure to carbamazepine monotherapy in the first trimester. In 131 registrations of malformations, the fetus had been exposed to carbamazepine monotherapy. Spina bifida was the only specific major congenital malformation significantly associated with exposure to carbamazepine monotherapy (odds ratio 2.6 (95% confidence interval 1.2 to 5.3) compared with no antiepileptic drug), but the risk was smaller for carbamazepine than for valproic acid (0.2, 0.1 to 0.6). There was no evidence for an association with total anomalous pulmonary venous return (no cases with carbamazepine exposure), cleft lip (with or without palate) (0.2, 0.0 to 1.3), diaphragmatic hernia (0.9, 0.1 to 6.6), or hypospadias (0.7, 0.3 to 1.6) compared with no exposure to antiepileptic drugs. Further exploratory analysis suggested a higher risk of single ventricle and atrioventricular septal defect. CONCLUSION: Carbamazepine teratogenicity is relatively specific to spina bifida, though the risk is less than with valproic acid. Despite the large dataset, there was not enough power to detect moderate risks for some rare major congenital malformations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

QDius2 és una aplicació pensada per a persones amb discapacitat visual. Consisteix en realitzar una descripció verbalitzada de l’estat d’un electrodomèstic utilitzant un dispositiu mòbil amb sistema operatiu Android. L’aplicació guiarà verbalment l’usuari perquè pugui enfocar el panell de control de l’electrodomèstic amb la càmera. Es processarà la imatge obtinguda per extreure la seva informació, ja sigui en el mateix mòbil o al núvol, segons les preferències de l’usuari, i es llegirà la informació resultant. Aquest projecte està dividit en vuit memòries, una per a cada integrant del grup.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Absent or reverse end-diastolic flow (Doppler II/III) in umbilical artery is correlated with poor perinatal outcome, particularly in intrauterine growth restricted (IUGR) fetuses. The optimal timing of delivery is still controversial. We studied the short- and long-term morbidity and mortality among these children associated with our defined management. STUDY DESIGN: Sixty-nine IUGR fetuses with umbilical Doppler II/III were divided into three groups; Group 1, severe early IUGR, no therapeutic intervention (n = 7); Group 2, fetuses with pathological biophysical profile, immediate delivery (n = 35); Group 3, fetuses for which expectant management had been decided (n = 27). RESULTS: In Group 1, stillbirth was observed after a mean delay of 6.3 days. Group 2 delivered at an average of 31.6 weeks and two died in the neonatal period (6%). In Group 3 after a mean delay of 8 days, average gestational age at delivery was 31.7 weeks; two intra uterine and four perinatal deaths were observed (22%). Long-term follow-up revealed no sequelae in 25/31 (81%) and 15/18 (83%), and major handicap occurred in 1 (3%) and 2 patients (11%), respectively, for Groups 2 and 3. CONCLUSION: Fetal mortality was observed in 22% of this high risk group. After a mean period of follow-up of 5 years, 82% of infants showed no sequelae. According to our management, IUGR associated with umbilical Doppler II or III does not show any benefit from an expectant management in term of long-term morbidity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. This study is an evaluation of the vacuum-assisted closure (VAC) therapy for the treatment of severe intrathoracic infections complicating lung resection, esophageal surgery, viscera perforation, or necrotizing pleuropulmonary infections.Methods. We reviewed the medical records of all patients treated by intrathoracic VAC therapy between January 2005 and December 2008. All patients underwent surgical debridement-decortication and control of the underlying cause of infection such as treatment of bronchus stump insufficiency, resection of necrotic lung, or closure of esophageal or intestinal leaks. Surgery was followed by intrathoracic VAC therapy until the infection was controlled. The VAC dressings were changed under general anesthesia and the chest wall was temporarily closed after each dressing change. All patients received systemic antibiotic therapy.Results. Twenty-seven patients (15 male, median age 64 years) underwent intrathoracic VAC dressings for the management of postresectional empyema (n = 8) with and without bronchopleural fistula, necrotizing infections (n = 7), and intrathoracic gastrointestinal leaks (n = 12). The median length of VAC therapy was 22 days (range 5 to 66) and the median number of VAC changes per patient was 6 (range 2 to 16). In-hospital mortality was 19% (n = 5) and was not related to VAC therapy or intrathoracic infection. Control of intrathoracic infection and closure of the chest cavity was achieved in all surviving patients.Conclusions. Vacuum-assisted closure therapy is an efficient and safe adjunct to treat severe intrathoracic infections and may be a good alternative to the open window thoracostomy in selected patients. Long time intervals in between VAC changes and short course of therapy result in good patient acceptance. (Ann Thorac Surg 2011;91:1582-90) (C) 2011 by The Society of Thoracic Surgeons

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A model of directed search with a finite number of buyers and sellers is considered, where sellers compete in direct mechanisms. Buyer heterogeneity and Nash equilibrium results in perfect sorting. The restriction to complementary inputs, that the match value function Q is supermodular, in addition coordinates the sellers strategies. In that case, equilibrium implements positive assortative matching, which is efficient and consistent with the stable (cooperative equilibrium) outcome. This provides a non-cooperative and decentralizedsolution for the Assignment Game. Conversely, if buyers are identical, no such coordination is possible, and there is a continuum of equilibria, one of which exhibits price posting, another yields competition in auctions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper studies a balance whose unobservable fulcrum is not necessarilylocated at the middle of its two pans. It presents three differentmodels, showing how this lack of symmetry modifies the observation, theformalism and the interpretation of such a biased measuring device. Itargues that the biased balance can be an interesting source of inspirationfor broadening the representational theory of measurement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Executive Summary The use of full-body restraint devices is a widespread practice in Iowa’s county jails. Full-body restraints come in the form of restraint chairs, boards, and beds, including two such devices manufactured in Iowa. Iowa law, which refers to these as four- and fivepoint restraints, states they are only to be used when an inmate is a threat to self, others, or jail security. However, the Ombudsman found they were also used on inmates who caused minor disruptions or in response to an inmate’s verbal abuse. In some cases, the restraints were used on inmates with known mental illness who were acting out, though no attempts were made to seek medical or mental health reviews for those inmates while restrained, leading to extended use of the restraint device.