961 resultados para intensity-duration-frequency relations


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Ethical conflicts are arising as a result of the growing complexity of clinical care, coupled with technological advances. Most studies that have developed instruments for measuring ethical conflict base their measures on the variables"frequency" and"degree of conflict". In our view, however, these variables are insufficient for explaining the root of ethical conflicts. Consequently, the present study formulates a conceptual model that also includes the variable"exposure to conflict", as well as considering six"types of ethical conflict". An instrument was then designed to measure the ethical conflicts experienced by nurses who work with critical care patients. The paper describes the development process and validation of this instrument, the Ethical Conflict in Nursing Questionnaire Critical Care Version (ECNQ-CCV). Methods: The sample comprised 205 nursing professionals from the critical care units of two hospitals in Barcelona (Spain). The ECNQ-CCV presents 19 nursing scenarios with the potential to produce ethical conflict in the critical care setting. Exposure to ethical conflict was assessed by means of the Index of Exposure to Ethical Conflict (IEEC), a specific index developed to provide a reference value for each respondent by combining the intensity and frequency of occurrence of each scenario featured in the ECNQ-CCV. Following content validity, construct validity was assessed by means of Exploratory Factor Analysis (EFA), while Cronbach"s alpha was used to evaluate the instrument"s reliability. All analyses were performed using the statistical software PASW v19. Results: Cronbach"s alpha for the ECNQ-CCV as a whole was 0.882, which is higher than the values reported for certain other related instruments. The EFA suggested a unidimensional structure, with one component accounting for 33.41% of the explained variance. Conclusions: The ECNQ-CCV is shown to a valid and reliable instrument for use in critical care units. Its structure is such that the four variables on which our model of ethical conflict is based may be studied separately or in combination. The critical care nurses in this sample present moderate levels of exposure to ethical conflict. This study represents the first evaluation of the ECNQ-CCV.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Ethical conflicts are arising as a result of the growing complexity of clinical care, coupled with technological advances. Most studies that have developed instruments for measuring ethical conflict base their measures on the variables"frequency" and"degree of conflict". In our view, however, these variables are insufficient for explaining the root of ethical conflicts. Consequently, the present study formulates a conceptual model that also includes the variable"exposure to conflict", as well as considering six"types of ethical conflict". An instrument was then designed to measure the ethical conflicts experienced by nurses who work with critical care patients. The paper describes the development process and validation of this instrument, the Ethical Conflict in Nursing Questionnaire Critical Care Version (ECNQ-CCV). Methods: The sample comprised 205 nursing professionals from the critical care units of two hospitals in Barcelona (Spain). The ECNQ-CCV presents 19 nursing scenarios with the potential to produce ethical conflict in the critical care setting. Exposure to ethical conflict was assessed by means of the Index of Exposure to Ethical Conflict (IEEC), a specific index developed to provide a reference value for each respondent by combining the intensity and frequency of occurrence of each scenario featured in the ECNQ-CCV. Following content validity, construct validity was assessed by means of Exploratory Factor Analysis (EFA), while Cronbach"s alpha was used to evaluate the instrument"s reliability. All analyses were performed using the statistical software PASW v19. Results: Cronbach"s alpha for the ECNQ-CCV as a whole was 0.882, which is higher than the values reported for certain other related instruments. The EFA suggested a unidimensional structure, with one component accounting for 33.41% of the explained variance. Conclusions: The ECNQ-CCV is shown to a valid and reliable instrument for use in critical care units. Its structure is such that the four variables on which our model of ethical conflict is based may be studied separately or in combination. The critical care nurses in this sample present moderate levels of exposure to ethical conflict. This study represents the first evaluation of the ECNQ-CCV.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Ethical conflicts are arising as a result of the growing complexity of clinical care, coupled with technological advances. Most studies that have developed instruments for measuring ethical conflict base their measures on the variables"frequency" and"degree of conflict". In our view, however, these variables are insufficient for explaining the root of ethical conflicts. Consequently, the present study formulates a conceptual model that also includes the variable"exposure to conflict", as well as considering six"types of ethical conflict". An instrument was then designed to measure the ethical conflicts experienced by nurses who work with critical care patients. The paper describes the development process and validation of this instrument, the Ethical Conflict in Nursing Questionnaire Critical Care Version (ECNQ-CCV). Methods: The sample comprised 205 nursing professionals from the critical care units of two hospitals in Barcelona (Spain). The ECNQ-CCV presents 19 nursing scenarios with the potential to produce ethical conflict in the critical care setting. Exposure to ethical conflict was assessed by means of the Index of Exposure to Ethical Conflict (IEEC), a specific index developed to provide a reference value for each respondent by combining the intensity and frequency of occurrence of each scenario featured in the ECNQ-CCV. Following content validity, construct validity was assessed by means of Exploratory Factor Analysis (EFA), while Cronbach"s alpha was used to evaluate the instrument"s reliability. All analyses were performed using the statistical software PASW v19. Results: Cronbach"s alpha for the ECNQ-CCV as a whole was 0.882, which is higher than the values reported for certain other related instruments. The EFA suggested a unidimensional structure, with one component accounting for 33.41% of the explained variance. Conclusions: The ECNQ-CCV is shown to a valid and reliable instrument for use in critical care units. Its structure is such that the four variables on which our model of ethical conflict is based may be studied separately or in combination. The critical care nurses in this sample present moderate levels of exposure to ethical conflict. This study represents the first evaluation of the ECNQ-CCV.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Ethical conflicts are arising as a result of the growing complexity of clinical care, coupled with technological advances. Most studies that have developed instruments for measuring ethical conflict base their measures on the variables"frequency" and"degree of conflict". In our view, however, these variables are insufficient for explaining the root of ethical conflicts. Consequently, the present study formulates a conceptual model that also includes the variable"exposure to conflict", as well as considering six"types of ethical conflict". An instrument was then designed to measure the ethical conflicts experienced by nurses who work with critical care patients. The paper describes the development process and validation of this instrument, the Ethical Conflict in Nursing Questionnaire Critical Care Version (ECNQ-CCV). Methods: The sample comprised 205 nursing professionals from the critical care units of two hospitals in Barcelona (Spain). The ECNQ-CCV presents 19 nursing scenarios with the potential to produce ethical conflict in the critical care setting. Exposure to ethical conflict was assessed by means of the Index of Exposure to Ethical Conflict (IEEC), a specific index developed to provide a reference value for each respondent by combining the intensity and frequency of occurrence of each scenario featured in the ECNQ-CCV. Following content validity, construct validity was assessed by means of Exploratory Factor Analysis (EFA), while Cronbach"s alpha was used to evaluate the instrument"s reliability. All analyses were performed using the statistical software PASW v19. Results: Cronbach"s alpha for the ECNQ-CCV as a whole was 0.882, which is higher than the values reported for certain other related instruments. The EFA suggested a unidimensional structure, with one component accounting for 33.41% of the explained variance. Conclusions: The ECNQ-CCV is shown to a valid and reliable instrument for use in critical care units. Its structure is such that the four variables on which our model of ethical conflict is based may be studied separately or in combination. The critical care nurses in this sample present moderate levels of exposure to ethical conflict. This study represents the first evaluation of the ECNQ-CCV.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to identify differences in swine vocalization pattern according to animal gender and different stress conditions. A total of 150 barrow males and 150 females (Dalland® genetic strain), aged 100 days, were used in the experiment. Pigs were exposed to different stressful situations: thirst (no access to water), hunger (no access to food), and thermal stress (THI exceeding 74). For the control treatment, animals were kept under a comfort situation (animals with full access to food and water, with environmental THI lower than 70). Acoustic signals were recorded every 30 minutes, totaling six samples for each stress situation. Afterwards, the audios were analyzed by Praat® 5.1.19 software, generating a sound spectrum. For determination of stress conditions, data were processed by WEKA® 3.5 software, using the decision tree algorithm C4.5, known as J48 in the software environment, considering cross-validation with samples of 10% (10-fold cross-validation). According to the Decision Tree, the acoustic most important attribute for the classification of stress conditions was sound Intensity (root node). It was not possible to identify, using the tested attributes, the animal gender by vocal register. A decision tree was generated for recognition of situations of swine hunger, thirst, and heat stress from records of sound intensity, Pitch frequency, and Formant 1.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Scanning optics create different types of phenomena and limitation to cladding process compared to cladding with static optics. This work concentrates on identifying and explaining the special features of laser cladding with scanning optics. Scanner optics changes cladding process energy input mechanics. Laser energy is introduced into the process through a relatively small laser spot which moves rapidly back and forth, distributing the energy to a relatively large area. The moving laser spot was noticed to cause dynamic movement in the melt pool. Due to different energy input mechanism scanner optic can make cladding process unstable if parameter selection is not done carefully. Especially laser beam intensity and scanning frequency have significant role in the process stability. The laser beam scanning frequency determines how long the laser beam affects with specific place local specific energy input. It was determined that if the scanning frequency in too low, under 40 Hz, scanned beam can start to vaporize material. The intensity in turn determines on how large package this energy is brought and if the intensity of the laser beam was too high, over 191 kW/cm2, laser beam started to vaporize material. If there was vapor formation noticed in the melt pool, the process starts to resample more laser alloying due to deep penetration of laser beam in to the substrate. Scanner optics enables more flexibility to the process than static optics. The numerical adjustment of scanning amplitude enables clad bead width adjustment. In turn scanner power modulation (where laser power is adjusted according to where the scanner is pointing) enables modification of clad bead cross-section geometry when laser power can be adjusted locally and thus affect how much laser beam melts material in each sector. Power modulation is also an important factor in terms of process stability. When a linear scanner is used, oscillating the scanning mirror causes a dwell time in scanning amplitude border area, where the scanning mirror changes the direction of movement. This can cause excessive energy input to this area which in turn can cause vaporization and process instability. This process instability can be avoided by decreasing energy in this region by power modulation. Powder feeding parameters have a significant role in terms of process stability. It was determined that with certain powder feeding parameter combinations powder cloud behavior became unstable, due to the vaporizing powder material in powder cloud. Mainly this was noticed, when either or both the scanning frequency or powder feeding gas flow was low or steep powder feeding angle was used. When powder material vaporization occurred, it created vapor flow, which prevented powder material to reach the melt pool and thus dilution increased. Also powder material vaporization was noticed to produce emission of light at wavelength range of visible light. This emission intensity was noticed to be correlated with the amount of vaporization in the powder cloud.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We compared the intensity and frequency of arthritis in old (8-12 months, N = 12) and juvenile (2 months, N = 10) rats and determined the role played by adrenal glands in this disorder. Arthritis was induced by subcutaneous injection of Mycobacterium butyricum at the base of the tail of female Holtzman rats at day zero. Paw edema and hyperalgesia were monitored from day zero to day 21 after induction as signs of arthritis development. Some (N = 11) old animals were adrenalectomized bilaterally and treated with dexamethasone or celecoxib immediately following surgery. All bilaterally adrenalectomized old animals became susceptible to arthritis and the onset of disease was shortened from the 10th to the 5th day. Hyperalgesia and paw edema responses were less frequent in older animals (50 and 25% compared to control juvenile rats, respectively), although old responder animals showed responses of similar intensity to those of their juvenile counterparts: by the 14th day the data for hyperalgesia were juvenile = 0.8 ± 0.07/old = 0.8 ± 0.09, and for paw edema juvenile = 56.6 ± 6.04/old = 32.24 ± 12.7, reported as delta% increase in paw edema. Chronic treatment of adrenalectomized old animals with dexamethasone (0.01 or 0.1 mg/kg) but not celecoxib (3 mg/kg), once daily for 21 days by gavage, abolished the effects of adrenalectomy, in particular those related to the hyperalgesia response (old = 0.95 ± 0.03/dexamethasone = 0 ± 0; 14th day), thus suggesting a specific participation of circulating corticosteroids in the modulation of pain in old arthritic rats.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Due to differences in study populations and protocols, the hemodynamic determinants of post-aerobic exercise hypotension (PAEH) are controversial. This review analyzed the factors that might influence PAEH hemodynamic determinants, through a search on PubMed using the following key words: “postexercise” or “post-exercise” combined with “hypotension”, “blood pressure”, “cardiac output”, and “peripheral vascular resistance”, and “aerobic exercise” combined only with “blood pressure”. Forty-seven studies were selected, and the following characteristics were analyzed: age, gender, training status, body mass index status, blood pressure status, exercise intensity, duration and mode (continuous or interval), time of day, and recovery position. Data analysis showed that 1) most postexercise hypotension cases are due to a reduction in systemic vascular resistance; 2) age, body mass index, and blood pressure status influence postexercise hemodynamics, favoring cardiac output decrease in elderly, overweight, and hypertensive subjects; 3) gender and training status do not have an isolated influence; 4) exercise duration, intensity, and mode also do not affect postexercise hemodynamics; 5) time of day might have an influence, but more data are needed; and 6) recovery in the supine position facilitates systemic vascular resistance decrease. In conclusion, many factors may influence postexercise hypotension hemodynamics, and future studies should directly address these specific influences because different combinations may explain the observed variability in postexercise hemodynamic studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Contexte. Les études cas-témoins sont très fréquemment utilisées par les épidémiologistes pour évaluer l’impact de certaines expositions sur une maladie particulière. Ces expositions peuvent être représentées par plusieurs variables dépendant du temps, et de nouvelles méthodes sont nécessaires pour estimer de manière précise leurs effets. En effet, la régression logistique qui est la méthode conventionnelle pour analyser les données cas-témoins ne tient pas directement compte des changements de valeurs des covariables au cours du temps. Par opposition, les méthodes d’analyse des données de survie telles que le modèle de Cox à risques instantanés proportionnels peuvent directement incorporer des covariables dépendant du temps représentant les histoires individuelles d’exposition. Cependant, cela nécessite de manipuler les ensembles de sujets à risque avec précaution à cause du sur-échantillonnage des cas, en comparaison avec les témoins, dans les études cas-témoins. Comme montré dans une étude de simulation précédente, la définition optimale des ensembles de sujets à risque pour l’analyse des données cas-témoins reste encore à être élucidée, et à être étudiée dans le cas des variables dépendant du temps. Objectif: L’objectif général est de proposer et d’étudier de nouvelles versions du modèle de Cox pour estimer l’impact d’expositions variant dans le temps dans les études cas-témoins, et de les appliquer à des données réelles cas-témoins sur le cancer du poumon et le tabac. Méthodes. J’ai identifié de nouvelles définitions d’ensemble de sujets à risque, potentiellement optimales (le Weighted Cox model and le Simple weighted Cox model), dans lesquelles différentes pondérations ont été affectées aux cas et aux témoins, afin de refléter les proportions de cas et de non cas dans la population source. Les propriétés des estimateurs des effets d’exposition ont été étudiées par simulation. Différents aspects d’exposition ont été générés (intensité, durée, valeur cumulée d’exposition). Les données cas-témoins générées ont été ensuite analysées avec différentes versions du modèle de Cox, incluant les définitions anciennes et nouvelles des ensembles de sujets à risque, ainsi qu’avec la régression logistique conventionnelle, à des fins de comparaison. Les différents modèles de régression ont ensuite été appliqués sur des données réelles cas-témoins sur le cancer du poumon. Les estimations des effets de différentes variables de tabac, obtenues avec les différentes méthodes, ont été comparées entre elles, et comparées aux résultats des simulations. Résultats. Les résultats des simulations montrent que les estimations des nouveaux modèles de Cox pondérés proposés, surtout celles du Weighted Cox model, sont bien moins biaisées que les estimations des modèles de Cox existants qui incluent ou excluent simplement les futurs cas de chaque ensemble de sujets à risque. De plus, les estimations du Weighted Cox model étaient légèrement, mais systématiquement, moins biaisées que celles de la régression logistique. L’application aux données réelles montre de plus grandes différences entre les estimations de la régression logistique et des modèles de Cox pondérés, pour quelques variables de tabac dépendant du temps. Conclusions. Les résultats suggèrent que le nouveau modèle de Cox pondéré propose pourrait être une alternative intéressante au modèle de régression logistique, pour estimer les effets d’expositions dépendant du temps dans les études cas-témoins

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este trabajo presenta el diseño e implementación de un programa progresivo de rehabilitación basado en los ejercicios musculares del suelo pélvico, incorporando el trabajo muscular de fuerza contrarresistencia. El disenño del estudio es casi experimental.La muestra es de 33 participantes en fase de tratamiento. Las variables de estudio son las antropométricas, las relacionadas con la evolución de la incontinencia urinaria(IU (intensidad, dificultad, frecuencia y limitación de las actividades),la obesidad, fatiga y dolor,la fuerza muscular y la calidad de vida(CdV). Para evaluar el cambio intrasujeto se tomaron medidas pretest(semana 0)y postest(semana24. En el análisis estadístico se utilizan las pruebas t Student-Fisher, Wilcoxon oU de Mann Whitney y el test del w2. El análisis se realiza con el programa SPSS versión 15. El nivel de significación escogido es del 5%. Al finalizar las 24 semanas del programa se identifica una disminución significativa de las variables antropométricas índice de cintura cadera (p¼0,003), perímetro de cintura(pr0,001) y porcentaje de masa de grasa(pr0,001); de las variables de IU: intensidad(pr0,0001), frecuencia y dificultad y su relación con la limitación de las actividades (pr0,0001), así como la relación existente entre la mejora de IU y la mejora de la CdV(p¼0,039). Queda científicamente demostrada la eficacia del programa progresivo de fuerza para disminuir la IU. La mejora de la CdV del hombre mayor con cáncer de prósstata viene mediada por la mejora de la continencia urinaria

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As Lesões Musculosqueléticas Relacionadas com o Trabalho (LMERT) são patologias inflamatórias e degenerativas do sistema musculosquelético desenvolvidas pelos trabalhadores quando sujeitos a determinados riscos profissionais. O crescente número de trabalhadores tem vindo a aumentar com lesões musculosqueléticas, embora não tenhamos encontrado estudos que analisem as LMERT na indústria dos moldes. Este estudo teve como finalidade avaliar o grau de incidência das lesões musculosqueléticas bem como as localizações mais relatadas. A amostra constituiu-se por 196 trabalhadores masculinos inquiridos por questionário. Os dados permitiram caracterizar a amostra quanto a hábitos de vida, condições de trabalho, ambiente de trabalho, posturas adotadas nas tarefas laborais bem como retirar informações quanto a queixas relativas às LMERT, as causas, a localização, a frequência da dor. Os resultados revelam que os trabalhadores desempenham tarefas de caráter repetitivo, fundamentalmente de pé e com poucas pausas. Os sintomas musculosqueléticos mais frequentes situam-se na zona lombar, nos joelhos, nos braços e na cabeça, sendo nos trabalhadores com mais idade que se registam mais sintomas, assim como dores mais intensas e permanentes. O trabalho termina com algumas recomendações para trabalhos futuros.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper examines the effects of armed conflicts between drug gangs in Rio de Janeiro's favelas on student achievement. We explore variation in violence that occurs across time and space when gangs battle over territories. Within-school estimates indicate that students from schools exposed to violence score less in math exams. The effect of violence increases with conflict intensity, duration, and proximity to exam dates; and decreases with the distance between the school and the conflict location. Finally, we find that school supply is an important mechanism driving the achievement results; armed conflicts are significantly associated with higher teacher absenteeism, principal turnover, and temporary school closings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

CONTEXTO E OBJETIVO: A associação entre ropivacaína e clonidina agiria menos que a ropivacaína isolada na mãe e no feto? Foram pesquisados os efeitos materno-fetais de duas técnicas farmacológicas: pequena dose de ropivacaína ou dose menor de ropivacaína mais clonidina na analgesia peridural para parto. TIPO DE ESTUDO E LOCAL: Estudo prospectivo, Departamento de Anestesiologia, Faculdade de Medicina de Botucatu, Universidade Estadual Paulista. MÉTODOS: Trinta e duas parturientes, estado físico de acordo com a American Society of Anesthesiologists I e II, foram aleatoriamente submetidas à analgesia peridural com 15 ml de ropivacaína 0,125% (grupo R) ou 15 ml de ropivacaína 0,0625% mais clonidina, 75 µg (grupo RC). Foram avaliados: intensidade da dor, nível do bloqueio sensitivo, latência, intensidade do bloqueio motor, duração da analgesia de parto e da analgesia peridural. Os neonatos foram avaliados pelo Apgar e método de Amiel-Tison (capacidade neurológica e adaptativa). RESULTADOS: Não houve diferenças significativas entre grupos para dor, nível de bloqueio sensitivo, duração da analgesia peridural e Apgar. Para latência, duração da analgesia de parto e bloqueio motor, grupo R < grupo RC. O escore da capacidade neurológica e adaptativa de meia e duas horas foi maior para o grupo R. Cem por cento dos neonatos do grupo R e 75% dos do grupo RC estavam neurologicamente saudáveis ao exame de 24 horas. CONCLUSÃO: Pequena dose de ropivacaína e dose menor mais clonidina aliviaram a dor materna durante o parto. Neonatos de mães que receberam apenas ropivacaína mostraram melhores escores da capacidade neurológica e adaptativa.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: Nosso objetivo foi investigar se o uso do solo do ambiente terrestre adjacente influencia a estrutura das assembleias fitoplanctônicas (composição, riqueza, diversidade e abundância) e biomassa (clorofila-a) em um riacho de Cerrado durante diferentes períodos do ano. MÉTODOS: Os trabalhos de campo foram realizados trimestralmente durante dois anos. RESULTADOS: As variáveis físico-químicas que melhor indicaram as diferenças nas condições da água foram condutividade, oxigênio dissolvido e transparência. Também houve um notável aumento na concentração de nitrogênio, fósforo e material em suspensão na água durante o verão devido aos efeitos da pluviosidade. As assembleias fitoplanctônicas foram compostas por 64 espécies. Cryptophyceae foi o grupo mais abundante, seguido por Bacillariophyceae. Para ambos os anos, a riqueza e a diversidade foram maiores durante a primavera e no outono, enquanto que a abundância do fitoplâncton e a concentração de clorofila-a foram mais elevados durante o outono e verão. A análise de agrupamento e a analise de correspondência canônica mostraram que a sazonalidade e o uso do solo são fatores importantes na estruturação das assembleias ao longo do ano. As alterações nas assembleias fitoplanctônicas ocorreram provavelmente em função da variação na intensidade e freqüência da mistura da água e da entrada de nutrientes oriundo do sistema terrestre adjacente para o aquático. CONCLUSÃO: A estrutura das assembleias fitoplanctônicas mostrou ser altamente influenciada pelo uso do solo, corroborando com a hipótese inicial do trabalho.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)