424 resultados para headspace
Resumo:
Edaphic factors affect the quality of onions (Allium cepa). Two experiments were carried out in the field and glasshouse to investigate the effects of N (field: 0, 120 kg ha(-1); glasshouse: 0, 108 kg ha(-1)), S (field: 0, 20 kg ha(-1); glasshouse: 0, 4.35 kg ha(-1)) and soil type (clay, sandy loam) on onion quality. A conducting polymer sensor electronic nose (E-nose) was used to classify onion headspace volatiles. Relative changes in the E-nose sensor resistance ratio (%dR/R) were reduced following N and S fertilisation. A 2D Principal Component Analysis (PCA) of the E-nose data sets accounted for c. 100% of the variations in onion headspace volatiles in both experiments. For the field experiment, E-nose data set clusters for headspace volatiles for no N-added onions overlapped (D-2 = 1.0) irrespective of S treatment. Headspace volatiles of N-fertilised onions for the glasshouse sandy loam also overlapped (D-2 = 1.1) irrespective of S treatment as compared with distinct separations among clusters for the clay soil. N fertilisation significantly (P < 0.01) reduced onion bulb pyruvic acid concentration (flavour) in both experiments. S fertilisation increased pyruvic acid concentration significantly (P < 0.01) in the glasshouse experiment, especially for the clay soil, but had no effect on pyruvic acid concentration in the field. N and S fertilisation significantly (P < 0.01) increased lachrymatory potency (pungency), but reduced total soluble solids (TSS) content in the field experiment. In the glasshouse experiment, N and S had no effect on TSS. TSS content was increased on the clay by 1.2-fold as compared with the sandy loam. Onion tissue N:water-soluble SO42- ratios of between five and eight were associated with greater %dR/R and pyruvic acid concentration values. N did not affect inner bulb tissue microbial load. In contrast, S fertilisation reduced inner bulb tissue microbial load by 80% in the field experiment and between 27% (sandy loam) and 92% (clay) in the glasshouse experiment. Overall, onion bulb quality discriminated by the E-nose responded to N, S and soil type treatments, and reflected their interactions. However, the conventional analytical and sensory measures of onion quality did not correlate with %dR/R.
Resumo:
Solid phase microextraction (SPME) offers a solvent-free and less labour-intensive alternative to traditional flavour isolation techniques. In this instance, SPME was optimised for the extraction of 17 stale flavour volatiles (C3-11,13 methyl ketones and C4-10 saturated aldehydes) from the headspace of full-cream ultrahigh-temperature (UHT)-processed milk. A comparison of relative extraction efficiencies was made using three fibre coatings, three extraction times and three extraction temperatures. Linearity of calibration curves, limits of detection and repeatability (coefficients of variation) were also used in determining the optimum extraction conditions. A 2 cm fibre coating of 50130 gm divinylbenzene/Carboxen/polydimethylsiloxane in conjunction with a 15 min extraction at 40 degrees C were chosen as the final optimum conditions. This method can be used as an objective tool for monitoring the flavour quality of UHT milk during storage. (c) 2005 Society of Chemical Industry.
Resumo:
Of those explants tested, immature zygotic embryo tissues proved to be the best for initiating callus with potential for somatic embryogenesis. Slicing of this tissue and use of the central sections (near to and including the meristematic tissue) gave the best embryogenic response. Slices that were placed under illumination necrosed more rapidly and to a greater degree than those incubated in the dark. Explant slice necrosis could be prevented or severely retarded by the addition of activated charcoal into the medium. Washing the explants for short periods of time prior to culture was also found to improve callus production. Prolonged washing resulted in low rates of callus production. In an attempt to prevent ethylene accumulation in the culture vessel headspace, AVG, an ethylene biosynthesis inhibitor and STS, a chemical which reduces the physiological action of ethylene, were successfully used to promote somatic embryogenesis. Spermidine, putrescine and spermine, polyamines that are known to delay plant senescence and promote somatic embryogenesis in some plant species, enhanced the rate of somatic embryogenesis when they were introduced into the callus induction medium. The use of polyethylene glycol in combination with abscisic acid helped promote somatic embryo formation and maturation as well as the subsequent formation of plantlets. The use of all of these improvements together has created a new and improved protocol for coconut somatic embryogenesis. This new protocol puts significant emphasis on improving the in vitro ecology of the explant, callus and somatic embryogenic tissues.
Resumo:
Smokeless powder additives are usually detected by their extraction from post-blast residues or unburned powder particles followed by analysis using chromatographic techniques. This work presents the first comprehensive study of the detection of the volatile and semi-volatile additives of smokeless powders using solid phase microextraction (SPME) as a sampling and pre-concentration technique. Seventy smokeless powders were studied using laboratory based chromatography techniques and a field deployable ion mobility spectrometer (IMS). The detection of diphenylamine, ethyl and methyl centralite, 2,4-dinitrotoluene, diethyl and dibutyl phthalate by IMS to associate the presence of these compounds to smokeless powders is also reported for the first time. A previously reported SPME-IMS analytical approach facilitates rapid sub-nanogram detection of the vapor phase components of smokeless powders. A mass calibration procedure for the analytical techniques used in this study was developed. Precise and accurate mass delivery of analytes in picoliter volumes was achieved using a drop-on-demand inkjet printing method. Absolute mass detection limits determined using this method for the various analytes of interest ranged between 0.03–0.8 ng for the GC-MS and between 0.03–2 ng for the IMS. Mass response graphs generated for different detection techniques help in the determination of mass extracted from the headspace of each smokeless powder. The analyte mass present in the vapor phase was sufficient for a SPME fiber to extract most analytes at amounts above the detection limits of both chromatographic techniques and the ion mobility spectrometer. Analysis of the large number of smokeless powders revealed that diphenylamine was present in the headspace of 96% of the powders. Ethyl centralite was detected in 47% of the powders and 8% of the powders had methyl centralite available for detection from the headspace sampling of the powders by SPME. Nitroglycerin was the dominant peak present in the headspace of the double-based powders. 2,4-dinitrotoluene which is another important headspace component was detected in 44% of the powders. The powders therefore have more than one headspace component and the detection of a combination of these compounds is achievable by SPME-IMS leading to an association to the presence of smokeless powders.
Resumo:
Human scent and human remains detection canines are used to locate living or deceased humans under many circumstances. Human scent canines locate individual humans on the basis of their unique scent profile, while human remains detection canines locate the general scent of decomposing human remains. Scent evidence is often collected by law enforcement agencies using a Scent Transfer Unit, a dynamic headspace concentration device. The goals of this research were to evaluate the STU-100 for the collection of human scent samples, and to apply this method to the collection of living and deceased human samples, and to the creation of canine training aids. The airflow rate and collection material used with the STU-100 were evaluated using a novel scent delivery method. Controlled Odor Mimic Permeation Systems were created containing representative standard compounds delivered at known rates, improving the reproducibility of optimization experiments. Flow rates and collection materials were compared. Higher air flow rates usually yielded significantly less total volatile compounds due to compound breakthrough through the collection material. Collection from polymer and cellulose-based materials demonstrated that the molecular backbone of the material is a factor in the trapping and releasing of compounds. The weave of the material also affects compound collection, as those materials with a tighter weave demonstrated enhanced collection efficiencies. Using the optimized method, volatiles were efficiently collected from living and deceased humans. Replicates of the living human samples showed good reproducibility; however, the odor profiles from individuals were not always distinguishable from one another. Analysis of the human remains samples revealed similarity in the type and ratio of compounds. Two types of prototype training aids were developed utilizing combinations of pure compounds as well as volatiles from actual human samples concentrated onto sorbents, which were subsequently used in field tests. The pseudo scent aids had moderate success in field tests, and the Odor pad aids had significant success. This research demonstrates that the STU-100 is a valuable tool for dog handlers and as a field instrument; however, modifications are warranted in order to improve its performance as a method for instrumental detection.
Resumo:
Sampling and preconcentration techniques play a critical role in headspace analysis in analytical chemistry. My dissertation presents a novel sampling design, capillary microextraction of volatiles (CMV), that improves the preconcentration of volatiles and semivolatiles in a headspace with high throughput, near quantitative analysis, high recovery and unambiguous identification of compounds when coupled to mass spectrometry. The CMV devices use sol-gel polydimethylsiloxane (PDMS) coated microglass fibers as the sampling/preconcentration sorbent when these fibers are stacked into open-ended capillary tubes. The design allows for dynamic headspace sampling by connecting the device to a hand-held vacuum pump. The inexpensive device can be fitted into a thermal desorption probe for thermal desorption of the extracted volatile compounds into a gas chromatography-mass spectrometer (GC-MS). The performance of the CMV devices was compared with two other existing preconcentration techniques, solid phase microextraction (SPME) and planar solid phase microextraction (PSPME). Compared to SPME fibers, the CMV devices have an improved surface area and phase volume of 5000 times and 80 times, respectively. One (1) minute dynamic CMV air sampling resulted in similar performance as a 30 min static extraction using a SPME fiber. The PSPME devices have been fashioned to easily interface with ion mobility spectrometers (IMS) for explosives or drugs detection. The CMV devices are shown to offer dynamic sampling and can now be coupled to COTS GC-MS instruments. Several compound classes representing explosives have been analyzed with minimum breakthrough even after a 60 min. sampling time. The extracted volatile compounds were retained in the CMV devices when preserved in aluminum foils after sampling. Finally, the CMV sampling device were used for several different headspace profiling applications which involved sampling a shipping facility, six illicit drugs, seven military explosives and eighteen different bacteria strains. Successful detection of the target analytes at ng levels of the target signature volatile compounds in these applications suggests that the CMV devices can provide high throughput qualitative and quantitative analysis with high recovery and unambiguous identification of analytes.
Resumo:
Smokeless powder additives are usually detected by their extraction from post-blast residues or unburned powder particles followed by analysis using chromatographic techniques. This work presents the first comprehensive study of the detection of the volatile and semi-volatile additives of smokeless powders using solid phase microextraction (SPME) as a sampling and pre-concentration technique. Seventy smokeless powders were studied using laboratory based chromatography techniques and a field deployable ion mobility spectrometer (IMS). The detection of diphenylamine, ethyl and methyl centralite, 2,4-dinitrotoluene, diethyl and dibutyl phthalate by IMS to associate the presence of these compounds to smokeless powders is also reported for the first time. A previously reported SPME-IMS analytical approach facilitates rapid sub-nanogram detection of the vapor phase components of smokeless powders. A mass calibration procedure for the analytical techniques used in this study was developed. Precise and accurate mass delivery of analytes in picoliter volumes was achieved using a drop-on-demand inkjet printing method. Absolute mass detection limits determined using this method for the various analytes of interest ranged between 0.03 - 0.8 ng for the GC-MS and between 0.03 - 2 ng for the IMS. Mass response graphs generated for different detection techniques help in the determination of mass extracted from the headspace of each smokeless powder. The analyte mass present in the vapor phase was sufficient for a SPME fiber to extract most analytes at amounts above the detection limits of both chromatographic techniques and the ion mobility spectrometer. Analysis of the large number of smokeless powders revealed that diphenylamine was present in the headspace of 96% of the powders. Ethyl centralite was detected in 47% of the powders and 8% of the powders had methyl centralite available for detection from the headspace sampling of the powders by SPME. Nitroglycerin was the dominant peak present in the headspace of the double-based powders. 2,4-dinitrotoluene which is another important headspace component was detected in 44% of the powders. The powders therefore have more than one headspace component and the detection of a combination of these compounds is achievable by SPME-IMS leading to an association to the presence of smokeless powders.