768 resultados para formative assessment in mathematics


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: A new caval tree system was designed for realistic in vitro simulation. The objective of our study was to assess cannula performance for virtually wall-less versus standard percutaneous thin-walled venous cannulas in a setting of venous collapse in case of negative pressure. METHODS: For a collapsible caval model, a very flexible plastic material was selected, and a model with nine afferent veins was designed according to the anatomy of the vena cava. A flow bench was built including a lower reservoir holding the caval tree, built by taking into account the main afferent vessels and their flow provided by a reservoir 6 cm above. A cannula was inserted in this caval tree and connected to a centrifugal pump that, in turn, was connected to a reservoir positioned 83 cm above the second lower reservoir (after-load = 60 mmHg). Using the same pre-load, the simulated venous drainage for cardiopulmonary bypass was realized using a 24 F wall-less cannula (Smartcanula) and 25 F percutaneous cannula (Biomedicus), and stepwise increased augmentation (1500 RPM, 2000 and 2500 RPM) of venous drainage. RESULTS: For the thin wall and the wall-less cannulas, 36 pairs of flow and pressure measurements were realized for three different RPM values. The mean Q-values at 1500, 2000 and 2500 RPM were: 3.98 ± 0.01, 6.27 ± 0.02 and 9.81 ± 0.02 l/min for the wall-less cannula (P <0.0001), versus 2.74 ± 0.02, 3.06 ± 0.05, 6.78 ± 0.02 l/min for the thin-wall cannula (P <0.0001). The corresponding inlet pressure values were: -8.88 ± 0.01, -23.69 ± 0.81 and -70.22 ± 0.18 mmHg for the wall-less cannula (P <0.0001), versus -36.69 ± 1.88, -80.85 ± 1.71 and -101.83 ± 0.45 mmHg for the thin-wall cannula (P <0.0001). The thin-wall cannula showed mean Q-values 37% less and mean P values 26% more when compared with the wall-less cannula (P <0.0001). CONCLUSIONS: Our in vitro water test was able to mimic a negative pressure situation, where the wall-less cannula design performs better compared with the traditional thin-wall cannula.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Protein-energy malnutrition is highly prevalent in aged populations. Associated clinical, economic, and social burden is important. A valid screening method that would be robust and precise, but also easy, simple, and rapid to apply, is essential for adequate therapeutic management. OBJECTIVES: To compare the interobserver variability of 2 methods measuring food intake: semiquantitative visual estimations made by nurses versus calorie measurements performed by dieticians on the basis of standardized color digital photographs of servings before and after consumption. DESIGN: Observational monocentric pilot study. SETTING/PARTICIPANTS: A geriatric ward. The meals were randomly chosen from the meal tray. The choice was anonymous with respect to the patients who consumed them. MEASUREMENTS: The test method consisted of the estimation of calorie consumption by dieticians on the basis of standardized color digital photographs of servings before and after consumption. The reference method was based on direct visual estimations of the meals by nurses. Food intake was expressed in the form of a percentage of the serving consumed and calorie intake was then calculated by a dietician based on these percentages. The methods were applied with no previous training of the observers. Analysis of variance was performed to compare their interobserver variability. RESULTS: Of 15 meals consumed and initially examined, 6 were assessed with each method. Servings not consumed at all (0% consumption) or entirely consumed by the patient (100% consumption) were not included in the analysis so as to avoid systematic error. The digital photography method showed higher interobserver variability in calorie intake estimations. The difference between the compared methods was statistically significant (P < .03). CONCLUSIONS: Calorie intake measures for geriatric patients are more concordant when estimated in a semiquantitative way. Digital photography for food intake estimation without previous specific training of dieticians should not be considered as a reference method in geriatric settings, as it shows no advantages in terms of interobserver variability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Factors associated with the detection of raised systolic pulmonary artery pressure (sPAP) levels in patients with a prior episode of pulmonary embolism (PE) are not well known. METHODS: We used the RIETE Registry database to identify factors associated with the finding of sPAP levels ≥50 mm Hg on trans-thoracic echocardiography, in 557 patients with a prior episode of acute, symptomatic PE. RESULTS: Sixty-two patients (11.1%; 95% CI: 8.72-14.1) had sPAP levels ≥50 mm Hg. These patients were more likely women, older, and more likely had chronic lung disease, heart failure, renal insufficiency or leg varicosities than those with PAP levels <50mm Hg. During the index PE event, they more likely had recent immobility, and more likely presented with hypoxemia, increased sPAP levels, atrial fibrillation, or right bundle branch block. On multivariate analysis, women aged ≥70 years (hazard ratio [HR]: 2.0; 95% CI: 1.0-3.7), chronic heart or chronic lung disease (HR: 2.4; 95% CI: 1.3-4.4), atrial fibrillation at PE presentation (HR: 2.8; 95% CI: 1.3-6.1) or varicose veins (HR: 1.8; 95% CI: 1.0-3.3) were all associated with an increased risk to have raised sPAP levels. Chronic heart disease, varicose veins, and atrial fibrillation were independent predictors in women, while chronic heart disease, atrial fibrillation, a right bundle branch block or an S1Q3T3 pattern on the electrocardiogram were independent predictors in men. CONCLUSIONS: Women aged ≥70 years more likely had raised sPAP levels than men after a PE episode. Additional variables influencing this risk seem to differ according to gender.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pain assessment in critically ill infants and nonverbal children remains a challenge for health professionals. Despite the numerous pain observational measures that have been developed or adapted for infants and children with impaired communication, pain prevalence in paediatric and neonatal intensive care unit remains too high. As pain assessment has been recognised as a pre-requisite for appropriate pain management, much effort was put in the validation or the adaptation of pain measures with little emphasis on implementation of these instruments into practice. Only a few studies demonstrated the benefit of using standardised protocols for the management of pain to guide practice with variable effects. When standardised protocols are undeniably useful in practice, they do not replace health professionals' clinical reasoning necessary to care for individuals. The diversity of the PICU population makes that pain scores need to be interpreted within its clinical context. This session will present pain assessment as a complex transaction that describes structured clinical reasoning from expert nurses that goes beyond the "silver" standard of hetero-evaluation of pain in non-communicative children. Besides pain scores, several patients and nurses factors play a major role in making decisions about analgesia and/or sedation. Patient's clinical instability, change in patient's clinical status, source for observed agitated behaviour, patient's known reactions to analgesia and sedation and anticipation of risks are factors that should be taken into account when implementing pain assessment and management guidelines in PICU and NICU.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the emergency situation, preoperative patient work-up for cardio-vascular surgery is quite different from the elective setting. We have analyzed a consecutive series of 5576 cases out of which 823 underwent emergency procedures (14.8%). The most frequent problems requiring emergent intervention were peripheral vascular (186 cases; 22.6% of the emergent procedure), followed by coronary artery disease (156 cases; 19.0%), thoracic aortic aneurysms (86 cases; 10.4%), abdominal aortic aneurysms (54 cases; 6.6%), congenital heart disease (36 cases: 4.4%), heart and heart lung transplantation (31 cases; 3.8%), problems with cardiac rythm (25 cases: 3.0%), and others (267 cases: 32.4%). Classification by proportion of urgent procedures with reference to elective operations shows a different picture. As a matter of fact transplantations were always emergency procedures (100%), whereas repair of aortic dissections type A and B was an emergency procedure in 81.5%. Emergency thoracic and abdominal aortic aneurysm repair accounted for 30% and 20% respectively and the corresponding proportion for peripheral vascular surgery is 19%. However, emergency surgery for acute coronary ischemia, valvular and congenital heart disease accounted for somewhat less than 10% for each group of these pathologies. Systematic pre-operative diagnostic work-up is a recognized tool for procedure related risk assessment and superior management of diseases. However, hemodynamic instability and other time related events correlated with negative outcome, are the main driving forces for accelerated diagnostic pathways

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: The estimated GFR (eGFR) is important in clinical practice. To find the best formula for eGFR, this study assessed the best model of correlation between sinistrin clearance (iGFR) and the solely or combined cystatin C (CysC)- and serum creatinine (SCreat)-derived models. It also evaluated the accuracy of the combined Schwartz formula across all GFR levels. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: Two hundred thirty-eight iGFRs performed between January 2012 and April 2013 for 238 children were analyzed. Regression techniques were used to fit the different equations used for eGFR (i.e., logarithmic, inverse, linear, and quadratic). The performance of each model was evaluated using the Cohen κ correlation coefficient and the percentage reaching 30% accuracy was calculated. RESULTS: The best model of correlation between iGFRs and CysC is linear; however, it presents a low κ coefficient (0.24) and is far below the Kidney Disease Outcomes Quality Initiative targets to be validated, with only 84% of eGFRs reaching accuracy of 30%. SCreat and iGFRs showed the best correlation in a fitted quadratic model with a κ coefficient of 0.53 and 93% accuracy. Adding CysC significantly (P<0.001) increased the κ coefficient to 0.56 and the quadratic model accuracy to 97%. Therefore, a combined SCreat and CysC quadratic formula was derived and internally validated using the cross-validation technique. This quadratic formula significantly outperformed the combined Schwartz formula, which was biased for an iGFR≥91 ml/min per 1.73 m(2). CONCLUSIONS: This study allowed deriving a new combined SCreat and CysC quadratic formula that could replace the combined Schwartz formula, which is accurate only for children with moderate chronic kidney disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims Perfusion-cardiac magnetic resonance (CMR) has emerged as a potential alternative to single-photon emission computed tomography (SPECT) to assess myocardial ischaemia non-invasively. The goal was to compare the diagnostic performance of perfusion-CMR and SPECT for the detection of coronary artery disease (CAD) using conventional X-ray coronary angiography (CXA) as the reference standard. Methods and results In this multivendor trial, 533 patients, eligible for CXA or SPECT, were enrolled in 33 centres (USA and Europe) with 515 patients receiving MR contrast medium. Single-photon emission computed tomography and CXA were performed within 4 weeks before or after CMR in all patients. The prevalence of CAD in the sample was 49%. Drop-out rates for CMR and SPECT were 5.6 and 3.7%, respectively (P = 0.21). The primary endpoint was non-inferiority of CMR vs. SPECT for both sensitivity and specificity for the detection of CAD. Readers were blinded vs. clinical data, CXA, and imaging results. As a secondary endpoint, the safety profile of the CMR examination was evaluated. For CMR and SPECT, the sensitivity scores were 0.67 and 0.59, respectively, with the lower confidence level for the difference of +0.02, indicating superiority of CMR over SPECT. The specificity scores for CMR and SPECT were 0.61 and 0.72, respectively (lower confidence level for the difference: -0.17), indicating inferiority of CMR vs. SPECT. No severe adverse events occurred in the 515 patients. Conclusion In this large multicentre, multivendor study, the sensitivity of perfusion-CMR to detect CAD was superior to SPECT, while its specificity was inferior to SPECT. Cardiac magnetic resonance is a safe alternative to SPECT to detect perfusion deficits in CAD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Quality control (QuaCo) in urology is mandatory to standardize or even increase the level of care. While QuaCo is undertaken at every step in the clinical pathway, it should focus on the patient's comorbidities and on the urologist and its complication rate. Resulting from political and economical pressures, comparing QuaCo and outcomes between urologists and institutions is nowadays often performed. However, careful interpretation of these comparisons is mandatory to avoid potential discriminations. Indeed, the reader has to make sure that patients groups and surgical techniques are comparable, definitions of complications are similar, classification of complications is standardized, and finally that the methodology in collecting data is irreproachable.