926 resultados para flying robot


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Object Recent years have been marked by efforts to improve the quality and safety of pedicle screw placement in spinal instrumentation. The aim of the present study is to compare the accuracy of the SpineAssist robot system with conventional fluoroscopy-guided pedicle screw placement. Methods Ninety-five patients suffering from degenerative disease and requiring elective lumbar instrumentation were included in the study. The robot cohort (Group I; 55 patients, 244 screws) consisted of an initial open robot-assisted subgroup (Subgroup IA; 17 patients, 83 screws) and a percutaneous cohort (Subgroup IB, 38 patients, 161 screws). In these groups, pedicle screws were placed under robotic guidance and lateral fluoroscopic control. In the fluoroscopy-guided cohort (Group II; 40 patients, 163 screws) screws were inserted using anatomical landmarks and lateral fluoroscopic guidance. The primary outcome measure was accuracy of screw placement on the Gertzbein-Robbins scale (Grade A to E and R [revised]). Secondary parameters were duration of surgery, blood loss, cumulative morphine, and length of stay. Results In the robot group (Group I), a perfect trajectory (A) was observed in 204 screws (83.6%). The remaining screws were graded B (n = 19 [7.8%]), C (n = 9 [3.7%]), D (n = 4 [1.6%]), E (n = 2 [0.8%]), and R (n = 6 [2.5%]). In the fluoroscopy-guided group (Group II), a completely intrapedicular course graded A was found in 79.8% (n = 130). The remaining screws were graded B (n = 12 [7.4%]), C (n = 10 [6.1%]), D (n = 6 [3.7%]), and E (n = 5 [3.1%]). The comparison of "clinically acceptable" (that is, A and B screws) was neither different between groups (I vs II [p = 0.19]) nor subgroups (Subgroup IA vs IB [p = 0.81]; Subgroup IA vs Group II [p = 0.53]; Subgroup IB vs Group II [p = 0.20]). Blood loss was lower in the robot-assisted group than in the fluoroscopy-guided group, while duration of surgery, length of stay, and cumulative morphine dose were not statistically different. Conclusions Robot-guided pedicle screw placement is a safe and useful tool for assisting spine surgeons in degenerative spine cases. Nonetheless, technical difficulties remain and fluoroscopy backup is advocated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Las tres leyes de la robótica no son más que los principios esenciales de una gran cantidad de sistemas éticos del mundo... ¿qué aspectos bioéticos nos devela esta película?.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coloring and activity book for children produced by the Iowa Department of Transportation Aviation Department.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Albert Lewin, a well-known Hollywood cinema director who is significantly influenced by the surrealistic movement, brings together the myth f Pandora and the legend of the flying Dutchman in order to create an exemplary love story, a crazy love story which goes beyond the limits of human reason. Bearing in mind, then, that if one wants to believe in this sort of love story must not be guided by human reason stricto sensu, he builds a world of signs, a semiologic world which this article aims at helping to interpret.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La palabra cyborg (del cyborg: cyber, cibernético y organism, organismo), designa una criatura compuesta de elementos orgánicos y mecánicos que mejoran las capacidades biológicas a través de la tecnología: es un individuo en parte hombre y en parte máquina.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Data sheet produced by the Iowa Department of Natural Resources is about different times of animals, insects, snakes, birds, fish, butterflies, etc. that can be found in Iowa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La palabra cyborg (del cyborg: cyber, cibernético y organism, organismo), designa una criatura compuesta de elementos orgánicos y mecánicos que mejoran las capacidades biológicas a través de la tecnología: es un individuo en parte hombre y en parte máquina.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Las tres leyes de la robótica no son más que los principios esenciales de una gran cantidad de sistemas éticos del mundo... ¿qué aspectos bioéticos nos devela esta película?.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chronic atrial fibrillation affects millions of people worldwide. Its surgical treatment often fails to restore the transport function of the atrium. This study first introduces the concept of an atrial assist device (AAD) to restore the pump function of the atrium. The AAD is developed to be totally implantable in the human body with a transcutaneous energy transfer system to recharge the implanted battery. The ADD consists of a motorless pump based on artificial muscle technology, positioned on the external surface of the atrium to compress it and restore its muscular activity. A bench model reproduces the function of a fibrillating atrium to assess the circulatory support that this pump can provide. Atripump (Nanopowers SA, Switzerland) is a dome-shaped silicone-coated nitinol actuator 5 mm high, sutured on the external surface of the atrium. A pacemaker-like control unit drives the actuator that compresses the atrium, providing the mechanical support to the blood circulation. Electrical characteristics: the system is composed of one actuator that needs a minimal tension of 15 V and has a maximum current of 1.5 A with a 50% duty cycle. The implantable rechargeable battery is made of a cell having the following specifications: nominal tension of a cell: 4.1 V, tension after 90% of discharge: 3.5 V, nominal capacity of a cell: 163 mA h. The bench model consists of an open circuit made of latex bladder 60 mm in diameter filled with water. The bladder is connected to a vertically positioned tube that is filled to different levels, reproducing changes in cardiac preload. The Atripump is placed on the outer surface of the bladder. Pressure, volume and temperature changes were recorded. The contraction rate was 1 Hz with a power supply of 12 V, 400 mA for 200 ms. Preload ranged from 15 to 21 cm H(2)O. Maximal silicone membrane temperature was 55 degrees C and maximal temperature of the liquid environment was 35 degrees C. The pump produced a maximal work of 16 x 10(-3) J. Maximal volume pumped was 492 ml min(-1). This artificial muscle pump is compact, follows the Starling law and reproduces the hemodynamic performances of a normal atrium. It could represent a new tool to restore the atrial kick in persistent atrial fibrillation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research extends a previously developed work concerning about the use of local model predictive control in mobile robots. Hence, experimental results are presented as a way to improve the methodology by considering aspects as trajectory accuracy and time performance. In this sense, the cost function and the prediction horizon are important aspects to be considered. The platformused is a differential driven robot with a free rotating wheel. The aim of the present work is to test the control method by measuring trajectory tracking accuracy and time performance. Moreover, strategies for the integration with perception system and path planning are also introduced. In this sense, monocular image data provide an occupancy grid where safety trajectories are computed by using goal attraction potential fields

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research work deals with the problem of modeling and design of low level speed controller for the mobile robot PRIM. The main objective is to develop an effective educational, and research tool. On one hand, the interests in using the open mobile platform PRIM consist in integrating several highly related subjects to the automatic control theory in an educational context, by embracing the subjects of communications, signal processing, sensor fusion and hardware design, amongst others. On the other hand, the idea is to implement useful navigation strategies such that the robot can be served as a mobile multimedia information point. It is in this context, when navigation strategies are oriented to goal achievement, that a local model predictive control is attained. Hence, such studies are presented as a very interesting control strategy in order to develop the future capabilities of the system. In this context the research developed includes the visual information as a meaningful source that allows detecting the obstacle position coordinates as well as planning the free obstacle trajectory that should be reached by the robot

Relevância:

20.00% 20.00%

Publicador:

Resumo:

S’arriba a un acord entre el grup de recerca GREFEMA i ViCOROB per estudiar els propulsors de palesutilitzats fins a l’actualitat en el robot submarí Girona 500, de forma que el model creatserveixi d’eina per apoder estudiar qualsevol tipus de propulsor que es vulgui fer servir.Es crearà un model de simulació amb CFD d’ANSYS per tal de poder recrear qualsevol situació ambqualsevol model de propulsor que es vulgui emprar, estalviant en costos de compra o fabricació, a mésd’evitar un muntatge experimental que pot no ser del tot fiable.A partir de geometries de propulsors de pales comercials existents es realitzarà una simulació amb elprograma de dinàmica de fluids computacional (CFD) d’ANSYS.La informació proporcionada per l’eina de simulació es compararan amb els resultats obtinguts de formaempírica a les instal•lacions del Parc Científic i Tecnològic de la Universitat de Girona i amb el model teòric.D’aquesta forma, es comprovarà la bondat de la simulació i es validarà el model numèric utilitzat

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The design of an efficient collaborative multirobot framework that ensures the autonomy and the individualrequirements of the involved robots is a very challenging task. This requires designing an efficient platform for inter-robot communication. P2P is a good approach to achieve this goal. P2P aims at making the communication ubiquitous thereby crossing the communication boundary and has many attractive features to use it as a platform for collaborative multi-robot environments. In this work, we present the JXTA Overlay P2P system and its application for robot control. Since JXTAOverlay is able to overcome Firewalls, Routers and NATs, it is possible to control end-devices in a WAN without changing the network security policy. We used JXTA-Overlay for the control of robot motors. We evaluated the proposed system by many experiments and have shown that the proposed system has a good performance and can be used successfully for the control of robot.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Localization, which is the ability of a mobile robot to estimate its position within its environment, is a key capability for autonomous operation of any mobile robot. This thesis presents a system for indoor coarse and global localization of a mobile robot based on visual information. The system is based on image matching and uses SIFT features as natural landmarks. Features extracted from training images arestored in a database for use in localization later. During localization an image of the scene is captured using the on-board camera of the robot, features are extracted from the image and the best match is searched from the database. Feature matching is done using the k-d tree algorithm. Experimental results showed that localization accuracy increases with the number of training features used in the training database, while, on the other hand, increasing number of features tended to have a negative impact on the computational time. For some parts of the environment the error rate was relatively high due to a strong correlation of features taken from those places across the environment.