957 resultados para finite-sample test
Resumo:
This paper analyzes whether standard covariance matrix tests work whendimensionality is large, and in particular larger than sample size. Inthe latter case, the singularity of the sample covariance matrix makeslikelihood ratio tests degenerate, but other tests based on quadraticforms of sample covariance matrix eigenvalues remain well-defined. Westudy the consistency property and limiting distribution of these testsas dimensionality and sample size go to infinity together, with theirratio converging to a finite non-zero limit. We find that the existingtest for sphericity is robust against high dimensionality, but not thetest for equality of the covariance matrix to a given matrix. For thelatter test, we develop a new correction to the existing test statisticthat makes it robust against high dimensionality.
Resumo:
BACKGROUND/AIMS: Cannabis use is a growing challenge for public health, calling for adequate instruments to identify problematic consumption patterns. The Cannabis Use Disorders Identification Test (CUDIT) is a 10-item questionnaire used for screening cannabis abuse and dependency. The present study evaluated that screening instrument. METHODS: In a representative population sample of 5,025 Swiss adolescents and young adults, 593 current cannabis users replied to the CUDIT. Internal consistency was examined by means of Cronbach's alpha and confirmatory factor analysis. In addition, the CUDIT was compared to accepted concepts of problematic cannabis use (e.g. using cannabis and driving). ROC analyses were used to test the CUDIT's discriminative ability and to determine an appropriate cut-off. RESULTS: Two items ('injuries' and 'hours being stoned') had loadings below 0.5 on the unidimensional construct and correlated lower than 0.4 with the total CUDIT score. All concepts of problematic cannabis use were related to CUDIT scores. An ideal cut-off between six and eight points was found. CONCLUSIONS: Although the CUDIT seems to be a promising instrument to identify problematic cannabis use, there is a need to revise some of its items.
Resumo:
Forensic Anthropology and Bioarchaeology studies depend critically on the accuracy and reliability of age-estimation techniques. In this study we have evaluated two age-estimation methods for adults based on the pubic symphysis (Suchey-Brooks) and the auricular surface (Buckberry-Chamberlain) in a current sample of 139 individuals (67 women and 72 men) from Madrid in order to verify the accuracy of both methods applied to a sample of innominate bones from the central Iberian Peninsula. Based on the overall results of this study, the Buckberry-Chamberlain method seems to be the method that provides better estimates in terms of accuracy (percentage of hits) and absolute difference to the chronological age taking into account the total sample. The percentage of hits and mean absolute difference of the Buckberry-Chamberlain and Suchey-Brooks methods are 97.3% and 11.24 years, and 85.7% and 14.38 years, respectively. However, this apparently greater applicability of the Buckberry-Chamberlain method is mainly due to the broad age ranges provided. Results indicated that Suchey-Brooks method is more appropriate for populations with a majority of young individuals, whereas Buckberry-Chamberlain method is recommended for populations with a higher percentage of individuals in the range 60-70 years. These different age estimation methodologies significantly influence the resulting demographic profile, consequently affecting the biological characteristics reconstruction of the samples in which they are applied.
Resumo:
The aim of this work was to calibrate the material properties including strength and strain values for different material zones of ultra-high strength steel (UHSS) welded joints under monotonic static loading. The UHSS is heat sensitive and softens by heat due to welding, the affected zone is heat affected zone (HAZ). In this regard, cylindrical specimens were cut out from welded joints of Strenx® 960 MC and Strenx® Tube 960 MH, were examined by tensile test. The hardness values of specimens’ cross section were measured. Using correlations between hardness and strength, initial material properties were obtained. The same size specimen with different zones of material same as real specimen were created and defined in finite element method (FEM) software with commercial brand Abaqus 6.14-1. The loading and boundary conditions were defined considering tensile test values. Using initial material properties made of hardness-strength correlations (true stress-strain values) as Abaqus main input, FEM is utilized to simulate the tensile test process. By comparing FEM Abaqus results with measured results of tensile test, initial material properties will be revised and reused as software input to be fully calibrated in such a way that FEM results and tensile test results deviate minimum. Two type of different S960 were used including 960 MC plates, and structural hollow section 960 MH X-joint. The joint is welded by BöhlerTM X96 filler material. In welded joints, typically the following zones appear: Weld (WEL), Heat affected zone (HAZ) coarse grained (HCG) and fine grained (HFG), annealed zone, and base material (BaM). Results showed that: The HAZ zone is softened due to heat input while welding. For all the specimens, the softened zone’s strength is decreased and makes it a weakest zone where fracture happens while loading. Stress concentration of a notched specimen can represent the properties of notched zone. The load-displacement diagram from FEM modeling matches with the experiments by the calibrated material properties by compromising two correlations of hardness and strength.
Resumo:
The present research focused on the pathways through which the symptoms of posttraumatic stress disorder (PTSD) may negatively impact intimacy. Previous research has confirmed a link between self-reported PTSD symptoms and intimacy; however, a thorough examination of mediating paths, partner effects, and secondary traumatization has not yet been realized. With a sample of 297 heterosexual couples, intraindividual and dyadic models were developed to explain the relationships between PTSD symptoms and intimacy in the context of interdependence theory, attachment theory, and models of selfpreservation (e.g., fight-or-flight). The current study replicated the findings of others and has supported a process in which affective (alexithymia, negative affect, positive affect) and communication (demand-withdraw behaviour, self-concealment, and constructive communication) pathways mediate the intraindividual and dyadic relationships between PTSD symptoms and intimacy. Moreover, it also found that the PTSD symptoms of each partner were significantly related; however, this was only the case for those dyads in which the partners had disclosed most everything about their traumatic experiences. As such, secondary traumatization was supported. Finally, although the overall pattern of results suggest a total negative effect of PTSD symptoms on intimacy, a sex difference was evident such that the direct effect of the woman's PTSD symptoms were positively associated with both her and her partner's intimacy. I t is possible that the Tend-andBefriend model of threat response, wherein women are said to foster social bonds in the face of distress, may account for this sex difference. Overall, however, it is clear that PTSD symptoms were negatively associated with relationship quality and attention to this impact in the development of diagnostic criteria and treatment protocols is necessary.
Resumo:
Resumen tomado de la publicaci??n. Resumen tambi??n en ingl??s
Resumo:
To plan testing activities, testers face the challenge of determining a strategy, including a test coverage criterion that offers an acceptable compromise between the available resources and test goals. Known theoretical properties of coverage criteria do not always help and, thus, empirical data are needed. The results of an experimental evaluation of several coverage criteria for finite state machines (FSMs) are presented, namely, state and transition coverage; initialisation fault and transition fault coverage. The first two criteria focus on FSM structure, whereas the other two on potential faults in FSM implementations. The authors elaborate a comparison approach that includes random generation of FSM, construction of an adequate test suite and test minimisation for each criterion to ensure that tests are obtained in a uniform way. The last step uses an improved greedy algorithm.
Resumo:
Paracoccidioidomycosis is diagnosed from the direct observation of the causative agent, but serology can facilitate and decrease the time required for diagnosis. The objective of this study was to determine the influence of serum sample inactivation on the performance of the latex agglutination test (LAT) for detecting antibodies against Paracoccidioides brasiliensis. The sensitivity of LAT from inactivated or non-inactivated samples was 73% and 83%, respectively and the LAT selectivity was 79% and 90%, respectively. The LAT evaluated here was no more specific than the double-immunodiffusion assay. We suggest the investigation of other methods for improving the LAT, such as the use of deglycosylated antigen.
Resumo:
The study of short implants is relevant to the biomechanics of dental implants, and research on crown increase has implications for the daily clinic. The aim of this study was to analyze the biomechanical interactions of a singular implant-supported prosthesis of different crown heights under vertical and oblique force, using the 3-D finite element method. Six 3-D models were designed with Invesalius 3.0, Rhinoceros 3D 4.0, and Solidworks 2010 software. Each model was constructed with a mandibular segment of bone block, including an implant supporting a screwed metal-ceramic crown. The crown height was set at 10, 12.5, and 15 mm. The applied force was 200 N (axial) and 100 N (oblique). We performed an ANOVA statistical test and Tukey tests; p < 0.05 was considered statistically significant. The increase of crown height did not influence the stress distribution on screw prosthetic (p > 0.05) under axial load. However, crown heights of 12.5 and 15 mm caused statistically significant damage to the stress distribution of screws and to the cortical bone (p <0.001) under oblique load. High crown to implant (C/I) ratio harmed microstrain distribution on bone tissue under axial and oblique loads (p < 0.001). Crown increase was a possible deleterious factor to the screws and to the different regions of bone tissue. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
Power calculations in a small sample comparative study, with a continuous outcome measure, are typically undertaken using the asymptotic distribution of the test statistic. When the sample size is small, this asymptotic result can be a poor approximation. An alternative approach, using a rank based test statistic, is an exact power calculation. When the number of groups is greater than two, the number of calculations required to perform an exact power calculation is prohibitive. To reduce the computational burden, a Monte Carlo resampling procedure is used to approximate the exact power function of a k-sample rank test statistic under the family of Lehmann alternative hypotheses. The motivating example for this approach is the design of animal studies, where the number of animals per group is typically small.