988 resultados para eye development


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose To develop a standardized questionnaire of near visual function and satisfaction to complement visual function evaluations of presbyopic corrections. Setting Eye Clinic, School of Life and Health Sciences, Aston University, Midland Eye Institute and Solihull Hospital, Birmingham, United Kingdom. Design Questionnaire development. Methods A preliminary 26-item questionnaire of previously used near visual function items was completed by patients with monofocal intraocular lenses (IOLs), multifocal IOLs, accommodating IOLs, multifocal contact lenses, or varifocal spectacles. Rasch analysis was used for item reduction, after which internal and test–retest reliabilities were determined. Construct validity was determined by correlating the resulting Near Activity Visual Questionnaire (NAVQ) scores with near visual acuity and critical print size (CPS), which was measured using the Minnesota Low Vision Reading Test chart. Discrimination ability was assessed through receiver-operating characteristic (ROC) curve analysis. Results One hundred fifty patients completed the questionnaire. Item reduction resulted in a 10-item NAVQ with excellent separation (2.92), internal consistency (Cronbach a = 0.95), and test–retest reliability (intraclass correlation coefficient = 0.72). Correlations of questionnaire scores with near visual acuity (r = 0.32) and CPS (r = 0.27) provided evidence of validity, and discrimination ability was excellent (area under ROC curve = 0.91). Conclusion Results show the NAVQ is a reliable, valid instrument that can be incorporated into the evaluation of presbyopic corrections.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fungi are ubiquitous organisms in nature and can be found in association with healthy eyes. The incidence of actual fungal infection of the eye, however, is relatively low compared with that attributable to viruses and bacteria. Nevertheless, fungal infection of the eye is increasing especially in immuno-compromised patients and a wide variety of fungal infections have now been described worldwide with species of Fusarium, Aspergillus, Candida, and dematiaceous fungi predominating. At present there are a limited number of compounds available to control ocular mycoses while resistance to anti-fungal agents has been growing in recent years, especially to azoles. Several mechanisms of resistance have been identified including modification of sterol synthesis pathways by the fungus, modification of enzymes to reduce the binding of azoles to fungal components and increased efficiency of removal of the azole within fungal cells. Although resistance to amphotericin-B has been reported, it continues to be the most important treatment for life-threatening conditions and more severe ophthalmic infections. Natamycin is often first choice for filamentous fungal keratitis and topical amphotericin-B for Candida keratitis. Continued monitoring of the behaviour of ocular fungi will be essential in future together with the development of new anti-fungal agents.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To develop a questionnaire that subjectively assesses near visual function in patients with 'accommodating' intraocular lenses (IOLs). Methods: A literature search of existing vision-related quality-of-life instruments identified all questions relating to near visual tasks. Questions were combined if repeated in multiple instruments. Further relevant questions were added and item interpretation confirmed through multidisciplinary consultation and focus groups. A preliminary 19-item questionnaire was presented to 22 subjects at their 4-week visit post first eye phacoemulsification with 'accommodative' IOL implantation, and again 6 and 12 weeks post-operatively. Rasch Analysis, Frequency of Endorsement, and tests of normality (skew and kurtosis) were used to reduce the instrument. Cronbach's alpha and test-retest reliability (intraclass correlation coefficient, ICC) were determined for the final questionnaire. Construct validity was obtained by Pearson's product moment correlation (PPMC) of questionnaire scores to reading acuity (RA) and to Critical Print Size (CPS) reading speed. Criterion validity was obtained by receiver operating characteristic (ROC) curve analysis and dimensionality of the questionnaire was assessed by factor analysis. Results: Rasch Analysis eliminated nine items due to poor fit statistics. The final items have good separation (2.55), internal consistency (Cronbach's α = 0.97) and test-retest reliability (ICC = 0.66). PPMC of questionnaire scores with RA was 0.33, and with CPS reading speed was 0.08. Area under the ROC curve was 0.88 and Factor Analysis revealed one principal factor. Conclusion: The pilot data indicates the questionnaire to be internally consistent, reliable and a valid instrument that could be useful for assessing near visual function in patients with 'accommodating' IOLS. The questionnaire will now be expanded to include other types of presbyopic correction. © 2007 British Contact Lens Association.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hydrogels, water swollen polymer matrices, have been utilised in many biomedical applications, as there is the potential to manipulate the properties for a given application by changing the chemical structure of the constituent monomers The eye provides an excellent site to examne the interaction between a synthetic material and a complex biological fluid without invasive surgery. There is a need for the development of new synthetic hydrogels for use in the anterior eye, Three applications of hydrogels in the eye were considered in this thesis. For some patients, the only hope of any visual improvement lies in the use of an artificial cornea, or keratoprosthesis, Preliminary investigations of a series of simple homogeneous hydrogel copolymers revealed that the mechanical properties required to withstand surgery and in eye stresses, were not achieved This lead to work on the development of semi-interpenetrating polymer networks based on the aforementioned copolymers, Manufacture of the device and cell response were also studied. Lasers have been employed in ocular surgery to correct refractive defects. If an irregular surface is ablated, an irregular surface is obtained. A hydrogel system was investigated that could be applied to the eye prior to ablation to create a smooth surface. Factors that may influence ablation rate were explored, Soft contact lenses can be used as a probe to study the interaction between synthetic materials and the biological constituents of tears. This has lead to the development of many sensitive analytical techniques for protein and lipid deposition, one of which is fluorescence spectrophotometry. Various commercially available soft contact lenses were worn for different periods of time and then analysed for protein and lipid deposition using fluorescence spectrophotometry, The influence of water content, degree of ionicity and the lens material on the level and type of deposition was investigated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The study utilized the advanced technology provided by automated perimeters to investigate the hypothesis that patients with retinitis pigmentosa behave atypically over the dynamic range and to concurrently determine the influence of extraneous factors on the format of the normal perimetric sensitivity profile. The perimetric processing of some patients with retinitis pigmentosa was considered to be abnormal in either the temporal and/or the spatial domain. The standard size III stimulus saturated the central regions and was thus ineffective in detecting early depressions in sensitivity in these areas. When stimulus size was scaled in inverse proportion to the square root of ganglion cell receptive field density (M-scaled), isosensitive profiles did not result, although cortical representation was theoretically equivalent across the visual field. It was conjectured that this was due to variations in the ganglion cell characteristics with increasing peripheral angle, most notably spatial summation. It was concluded that the development of perimetric routines incorporating stimulus sizes adjusted in proportion to the coverage factor of retinal ganglion cells would enhance the diagnostic capacity of perimetry. Good general and local correspondence was found between perimetric sensitivity and the available retinal cell counts. Intraocular light scatter arising both from simulations and media opacities depressed perimetric sensitivity. Attenuation was greater centrally for the smaller LED stimuli, whereas the reverse was true for the larger projected stimuli. Prior perimetric experience and pupil size also demonstrated eccentricity-dependent effect on sensitivity. Practice improved perimetric sensitivity for projected stimuli at eccentricities greater than or equal to 30o; particularly in the superior region. Increase in pupil size for LED stimuli enhanced sensitivity at eccentricities greater than 10o. Conversely, microfluctuation in the accommodative response during perimetric examination and the correction of peripheral refractive error had no significant influence on perimetric sensitivity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Since the initial launch of silicone hydrogel lenses, there has been a considerable broadening in the range of available commercial material properties. The very mobile silicon–oxygen bonds convey distinctive surface and mechanical properties on silicone hydrogels, in which advantages of enhanced oxygen permeability, reduced protein deposition, and modest frictional interaction are balanced by increased lipid and elastic response. There are now some 15 silicone hydrogel material variants available to practitioners; arguably, the changes that have taken place have been strongly influenced by feedback based on clinical experience. Water content is one of the most influential properties, and the decade has seen a progressive rise from lotrafilcon-A (24%) to efrofilcon-A (74%). Moduli have decreased over the same period from 1.4 to 0.3 MPa, but not solely as a result of changes in water content. Surface properties do not correlate directly with water content, and ingenious approaches have been used to achieve desirable improvements (e.g., greater lubricity and lower contact angle hysteresis). This is demonstrated by comparing the hysteresis value of the earliest (lotrafilcon-A, >40°) and most recent (delefilcon-A, <10°) coated silicone hydrogels. Although wettability is important, it is not of itself a good predictor of ocular response because this involves a much wider range of physicochemical and biochemical factors. The interference of the lens with ocular dynamics is complex leading separately to tissue–material interactions involving anterior and posterior lens surfaces. The biochemical consequences of these interactions may hold the key to a greater understanding of ocular incompatibility and end of day discomfort.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

While knowledge about standardization of skin protection against ultraviolet radiation (UVR) has progressed over the past few decades, there is no uniform and generally accepted standardized measurement for UV eye protection. The literature provides solid evidence that UV can induce considerable damage to structures of the eye. As well as damaging the eyelids and periorbital skin, chronic UV exposure may also affect the conjunctiva and lens. Clinically, this damage can manifest as skin cancer and premature skin ageing as well as the development of pterygia and premature cortical cataracts. Modern eye protection, used daily, offers the opportunity to prevent these adverse sequelae of lifelong UV exposure. A standardized, reliable and comprehensive label for consumers and professionals is currently lacking. In this review we (i) summarize the existing literature about UV radiation-induced damage to the eye and surrounding skin; (ii) review the recent technological advances in UV protection by means of lenses; (iii) review the definition of the Eye-Sun Protection Factor (E-SPF®), which describes the intrinsic UV protection properties of lenses and lens coating materials based on their capacity to absorb or reflect UV radiation; and (iv) propose a strategy for establishing the biological relevance of the E-SPF. © 2013 John Wiley & Sons A/S.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis describes the design and development of an eye alignment/tracking system which allows self alignment of the eye’s optical axis with a measurement axis. Eye alignment is an area of research largely over-looked, yet it is a fundamental requirement in the acquisition of clinical data from the eye. New trends in the ophthalmic market, desiring portable hand-held apparatus, and the application of ophthalmic measurements in areas other than vision care have brought eye alignment under new scrutiny. Ophthalmic measurements taken in hand-held devices with out an clinician present requires alignment in an entirely new set of circumstances, requiring a novel solution. In order to solve this problem, the research has drawn upon eye tracking technology to monitor the eye, and a principle of self alignment to perform alignment correction. A handheld device naturally lends itself to the patient performing alignment, thus a technique has been designed to communicate raw eye tracking data to the user in a manner which allows the user to make the necessary corrections. The proposed technique is a novel methodology in which misalignment to the eye’s optical axis can be quantified, corrected and evaluated. The technique uses Purkinje Image tracking to monitor the eye’s movement as well as the orientation of the optical axis. The use of two sets of Purkinje Images allows quantification of the eye’s physical parameters needed for accurate Purkinje Image tracking, negating the need for prior anatomical data. An instrument employing the methodology was subsequently prototyped and validated, allowing a sample group to achieve self alignment of their optical axis with an imaging axis within 16.5-40.8 s, and with a rotational precision of 0.03-0.043°(95% confidence intervals). By encompassing all these factors the technique facilitates self alignment from an unaligned position on the visual axis to an aligned position on the optical axis. The consequence of this is that ophthalmic measurements, specifically pachymetric measurements, can be made in the absence of an optician, allowing the use of ophthalmic instrumentation and measurements in health professions other than vision care.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: To assess whether the current starting age of 12 is suitable for diabetic retinopathy (DR) screening and whether diabetes duration should be taken into account when deciding at what age to start screening patients. Materials and methods: A retrospective analysis of 143 patients aged 12 years or younger who attended diabetic eye screening for the first time in the Birmingham, Solihull and Black Country Diabetic Eye Screening Programme was performed. Results: The mean age of the patients was 10.7 (7-12) years with 73 out of 143 aged below 12 years and 70 were 12 years of age. 98% had type 1 diabetes and mean diabetes duration was 5 (1 month-11 years) years. For those younger than 12 years, 7/73 (9.6%) had background DR (BDR), of these mean diabetes duration was 7 years (6-8). The youngest patient to present with DR was aged 8 years. In those aged 12 years, 5/70 (7.1%) had BDR; of these mean diabetes duration was 8 years (6-11). No patient developed DR before 6 years duration in either group. Conclusions: The results show that no patient younger than the age of 12 had sight-threatening DR (STDR), but BDR was identified. Based on the current mission statement of the Diabetic Eye Screening Programme to identify STDR, 12 years of age is confirmed as the right age to start screening, but if it is important to diabetic management to identify first development of DR, then screening should begin after 6 years of diabetes diagnosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to: i) determine if the attention bias towards angry faces reported in eating disorders generalises to a non-clinical sample varying in eating disorder-related symptoms; ii) examine if the bias occurs during initial orientation or later strategic processing; and iii) confirm previous findings of impaired facial emotion recognition in non-clinical disordered eating. Fifty-two females viewed a series of face-pairs (happy or angry paired with neutral) whilst their attentional deployment was continuously monitored using an eye-tracker. They subsequently identified the emotion portrayed in a separate series of faces. The highest (n=18) and lowest scorers (n=17) on the Eating Disorders Inventory (EDI) were compared on the attention and facial emotion recognition tasks. Those with relatively high scores exhibited impaired facial emotion recognition, confirming previous findings in similar non-clinical samples. They also displayed biased attention away from emotional faces during later strategic processing, which is consistent with previously observed impairments in clinical samples. These differences were related to drive-for-thinness. Although we found no evidence of a bias towards angry faces, it is plausible that the observed impairments in emotion recognition and avoidance of emotional faces could disrupt social functioning and act as a risk factor for the development of eating disorders.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The successful design of polymers for contact lens applications depends on the ability to provide a balance of properties appropriate to the ocular environment. Principal relevant aspects of the anterior eye are the tear film, eyelid and cornea, which govern the requirements for surface properties, modulus and oxygen permeability, respectively. Permeability requirements and the developing view of the needs of the cornea, in terms of oxygen consumption and the particular roles of fluorine and silicon in the design of silicone hydrogels, which have proved to be the most successful family of materials for this demanding application, are discussed. The contact lens field is complicated by the fact that contact lenses are used in a range of wear modalities, the extremes of which can conveniently be classified as lenses that are disposed of at the end of a single period of daily wear and those used for 30. days of successive day-and-night periods, frequently referred to as extended or continuous wear. As silicone hydrogels developed, in the decade following their launch there has been a progressive trend in properties taking both modulus and water content closer to those of conventional hydrogels. This is particularly evident in the family of daily disposable contact lenses that have appeared since 2008.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This research pursued the conceptualization and real-time verification of a system that allows a computer user to control the cursor of a computer interface without using his/her hands. The target user groups for this system are individuals who are unable to use their hands due to spinal dysfunction or other afflictions, and individuals who must use their hands for higher priority tasks while still requiring interaction with a computer. ^ The system receives two forms of input from the user: Electromyogram (EMG) signals from muscles in the face and point-of-gaze coordinates produced by an Eye Gaze Tracking (EGT) system. In order to produce reliable cursor control from the two forms of user input, the development of this EMG/EGT system addressed three key requirements: an algorithm was created to accurately translate EMG signals due to facial movements into cursor actions, a separate algorithm was created that recognized an eye gaze fixation and provided an estimate of the associated eye gaze position, and an information fusion protocol was devised to efficiently integrate the outputs of these algorithms. ^ Experiments were conducted to compare the performance of EMG/EGT cursor control to EGT-only control and mouse control. These experiments took the form of two different types of point-and-click trials. The data produced by these experiments were evaluated using statistical analysis, Fitts' Law analysis and target re-entry (TRE) analysis. ^ The experimental results revealed that though EMG/EGT control was slower than EGT-only and mouse control, it provided effective hands-free control of the cursor without a spatial accuracy limitation, and it also facilitated a reliable click operation. This combination of qualities is not possessed by either EGT-only or mouse control, making EMG/EGT cursor control a unique and practical alternative for a user's cursor control needs. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Effective interaction with personal computers is a basic requirement for many of the functions that are performed in our daily lives. With the rapid emergence of the Internet and the World Wide Web, computers have become one of the premier means of communication in our society. Unfortunately, these advances have not become equally accessible to physically handicapped individuals. In reality, a significant number of individuals with severe motor disabilities, due to a variety of causes such as Spinal Cord Injury (SCI), Amyothrophic Lateral Sclerosis (ALS), etc., may not be able to utilize the computer mouse as a vital input device for computer interaction. The purpose of this research was to further develop and improve an existing alternative input device for computer cursor control to be used by individuals with severe motor disabilities. This thesis describes the development and the underlying principle for a practical hands-off human-computer interface based on Electromyogram (EMG) signals and Eye Gaze Tracking (EGT) technology compatible with the Microsoft Windows operating system (OS). Results of the software developed in this thesis show a significant improvement in the performance and usability of the EMG/EGT cursor control HCI.