952 resultados para diamond electrodes
Resumo:
Some material aspects such as grain size, purity and anisotropy exert an important influence on surface quality, especially in single point diamond turning. The aim of this paper is to present and discuss some critical factors that can limit the accuracy of ultraprecision machining of non-ferrous metals and to identify the effects of them on the cutting mechanism with single point diamond tools. This will be carried out through observations of machined surfaces and chips produced using optical and scanning electron microscopy. Solutions to reduce the influence of some of these limiting factors related with the mechanism of generation of mirror-like surfaces will be discussed.
Resumo:
This paper discusses the effect of tool wear on surface finish in single-point diamond turning of single crystal silicon. The morphology and topography of the machined surface clearly show the type of cutting edge wear reproduced onto the cutting grooves. Scanning electron microscopy is used in order to correlate the cutting edge damage and microtopography features observed through atomic force microscopy. The possible wear mechanisms affecting tool performance and surface generation during cutting are also discussed. The zero degree rake angle single point diamond tool presented small nicks on the cutting edge. The negative rake angle tools presented more a type of crater wear on the rake face. No wear was detected on flank face of the diamond tools.
Resumo:
Potentiometric sensors are very attractive tools for chemical analysis because of their simplicity, low power consumption and low cost. They are extensively used in clinical diagnostics and in environmental monitoring. Modern applications of both fields require improvements in the conventional construction and in the performance of the potentiometric sensors, as the trends are towards portable, on-site diagnostics and autonomous sensing in remote locations. The aim of this PhD work was to improve some of the sensor properties that currently hamper the implementation of the potentiometric sensors in modern applications. The first part of the work was concentrated on the development of a solid-state reference electrode (RE) compatible with already existing solid-contact ion-selective electrodes (ISE), both of which are needed for all-solid-state potentiometric sensing systems. A poly(vinyl chloride) membrane doped with a moderately lipophilic salt, tetrabutylammonium-tetrabutylborate (TBA-TBB), was found to show a satisfactory stability of potential in sample solutions with different concentrations. Its response time was nevertheless slow, as it required several minutes to reach the equilibrium. The TBA-TBB membrane RE worked well together with solid-state ISEs in several different situations and on different substrates enabling a miniature design. Solid contacts (SC) that mediate the ion-to-electron transduction are crucial components of well-functioning potentiometric sensors. This transduction process converting the ionic conduction of an ion-selective membrane to the electronic conduction in the circuit was studied with the help of electrochemical impedance spectroscopy (EIS). The solid contacts studied were (i) the conducting polymer (CP) poly(3,4-ethylienedioxythiophene) (PEDOT) and (ii) a carbon cloth having a high surface area. The PEDOT films were doped with a large immobile anion poly(styrene sulfonate) (PSS-) or with a small mobile anion Cl-. As could be expected, the studied PEDOT solid-contact mediated the ion-toelectron transduction more efficiently than the bare glassy carbon substrate, onto which they were electropolymerized, while the impedance of the PEDOT films depended on the mobility of the doping ion and on the ions in the electrolyte. The carbon cloth was found to be an even more effective ion-to-electron transducer than the PEDOT films and it also proved to work as a combined electrical conductor and solid contact when covered with an ion-selective membrane or with a TBA-TBB-based reference membrane. The last part of the work was focused on improving the reproducibility and the potential stability of the SC-ISEs, a problem that culminates to the stability of the standard potential E°. It was proven that the E° of a SC-ISE with a conducting polymer as a solid contact could be adjusted by reducing or oxidizing the CP solid contact by applying current pulses or a potential to it, as the redox state of the CP solid-contact influences the overall potential of the ISE. The slope and thus the analytical performance of the SC-ISEs were retained despite the adjustment of the E°. The shortcircuiting of the SC-ISE with a conventional large-capacitance RE was found to be a feasible instrument-free method to control the E°. With this method, the driving force for the oxidation/reduction of the CP was the potential difference between the RE and the SC-ISE, and the position of the adjusted potential could be controlled by choosing a suitable concentration for the short-circuiting electrolyte. The piece-to-piece reproducibility of the adjusted potential was promising, and the day-today reproducibility for a specific sensor was excellent. The instrumentfree approach to control the E° is very attractive considering practical applications.
Resumo:
Référence bibliographique : Rol, 59930
Resumo:
Receipt from Tiffany and Co., New York for a diamond lace pin, Nov. 3, 1884.
Resumo:
Tesis (Maestría en Ciencias con acentuación en Microbiología) UANL, 2014.
Resumo:
Dipyrromethene-Cu(II) derivatives possessing two dodecane alkyl chains have been used for the modification of gold electrodes. Electroactive host molecules have been incorporated into a lipophilic dodecanethiol SAM deposited onto gold electrodes through hydrophobic and van der Waals interactions (embedment technique). The presence of dipyrromethene-Cu(II) redox centers on the electrode surface was proved by cyclic voltammetry and Osteryoung square-wave voltammetry. The Au electrodes incorporating redox active Cu(II)-dipyrromethene SAMs were used for the direct voltammetric determination of paracetamol in human plasma.
Resumo:
The main objective of this thesis work is to optimize the growth conditions for obtaining crystalline and conducting Lao.5Sro.5Co03 (LSCO) and Lao.5Sro.5Coo.5.5Nio.5O3 (LSCNO) thin films at low processing temperatures. The films are prepared by radio frequency magnetron sputtering under various deposition conditions. The thin films were used as electrodes for the fabrication of ferroelectric capacitors using BaO.7SrO.3 Ti03 (BST) and PbZro.52 Tio.4803 (PZT). The structural and transport properties of the La1_xSrxCo03 and Lao.5Sro.5Co1_xNix03 are also investigated. The characterization of the bulk and the thin films were performed using different tools. A powder X-ray diffractometer was used to analyze the crystalline nature of the material. The transport properties were investigated by measuring the temperature dependence of resistivity using a four probe technique. The magnetoresistance and thermoelectric power were also used to investigate the transport properties. Atomic force microscope was used to study the surface morphology and thin film roughness. The ferroelectric properties of the capacitors were investigated using RT66A ferroelectric tester.
Resumo:
Diamant ist ein Material mit vielen außerordentlichen Eigenschaften, die ihn zu einem äußerst vielversprechenden Kandidaten für Anwendungen in Wissen-schaft und Technik machen. In den letzten Jahren wurde Diamant häufig als einzigartige Plattform für neue Anwendungen beispielsweise in der Quanteninformationstechnologie (QIT) oder in der Magnetometrie im Nanometermaßstab eingesetzt, wobei einer der wichtigsten lumineszierenden Gitterdefekte im Diamantgitter eingesetzt wird. Dabei handelt es sich um die sogenannten Stickstoff/Fehlenstellen-Farbzentren (NV-Zentren), die im sichtbaren Bereich mit einer absoluten Photostabilität bei Raumtemperatur emittieren. In dieser Arbeit wurden NV-Zentren in Diamantnanokristalliten und –nanosäulen untersucht, die während des Wachstumsprozesses erzeugt wurden. Einzelne Diamantnanokristallite und nanokristalline Diamantschichten (NCD), aus denen Nanosäulen geätzt wurden, wurden mithilfe der Hot Filament Chemical Vapour Deposition (HFCVD) abgeschieden. Zu Vergleichszwecken wurden auch ultrananokristalline Diamantschichten (UNCD) mittels Mikrowellen-CVD (MWCVD) hergestellt. Die Filme wurden sorgfältig in Bezug auf ihre Morphologie, kristallinen Eigenschaften und Zusammensetzung untersucht. Um die Möglichkeit einer Integration dieser Diamantschichten mit temperaturempfindlichen Materialien wie III/V-Halbleitern, Metallen mit niedrigem Schmelzpunkt oder Polymeren zu untersuchen, wurde der Einfluss der Substrattemperatur ermittelt. Eindimensionale NCD- und UNCD-Diamantnanostrukturen wurden mithilfe der Elektronenstrahllithographie (EBL) und reaktivem Ionenätzen in einem induktiv gekoppelten O2-Plasma (ICP-RIE) hergestellt. Zur Vorbereitung wurden zunächst die Ätzraten in Abhängigkeit von den vier wichtigsten Parametern ermittelt. Weitere Erkenntnisse über die Ätzmechanismen wurden durch Ätzexperiment mit unstrukturierten NCD- und UNCD-Schichten erhalten Mittels der EBL konnten mithilfe von Gold-Ätzmasken Nanosäulen mit Durchmessern von 50 nm bis zu 1 μm hergestellt werden.Eine optische Charakterisierung der NCD- und UNCD-Nanosäulen erfolgte mithilfe von Fluorenzenz-Mapping und Photomumineszenz-Spektroskopie. Diese Messungen ergaben, dass in beiden Arten von Säulen NV-Zentren vorhanden sind. Allerdings wurden nur in NCD-Säulen die gewünschten NV--Zentren gefunden, in UNCD-Säulen hingegen nur NV0-Zentren.
Resumo:
Photograph showing diamond skin disease in a pig.