943 resultados para deuterated standard


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare the diagnostic efficiency of plain film and spiral CT examinations with 3D reconstructions of 42 tibial plateau fractures and to assess the accuracy of these two techniques in the pre-operative surgical plan in 22 cases. Forty-two tibial plateau fractures were examined with plain film (anteroposterior, lateral, two obliques) and spiral CT with surface-shaded-display 3D reconstructions. The Swiss AO-ASIF classification system of bone fracture from Muller was used. In 22 cases the surgical plans and the sequence of reconstruction of the fragments were prospectively determined with both techniques, successively, and then correlated with the surgical reports and post-operative plain film. The fractures were underestimated with plain film in 18 of 42 cases (43%). Due to the spiral CT 3D reconstructions, and precise pre-operative information, the surgical plans based on plain film were modified and adjusted in 13 cases among 22 (59%). Spiral CT 3D reconstructions give a better and more accurate demonstration of the tibial plateau fracture and allows a more precise pre-operative surgical plan.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Allele frequencies and forensically relevant population statistics of 16 STR loci, including the new European Standard Set (ESS) loci, were estimated from 668 unrelated individuals of Caucasian appearance living in different parts of Switzerland. The samples were amplified with a combination of the following three kits: AmpFlSTR® NGM SElect?, PowerPlex® ESI17 and PowerPlex® ESX 17. All loci were highly polymorphic and no significant departure from Hardy-Weinberg equilibrium and linkage equilibrium was detected after correction for sampling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To examine the relationship of functional measurements with structural measures. Methods: 146 eyes of 83 test subjects underwent Heidelberg Retinal Tomography (HRTIII) (disc area<2.43, mphsd<40), and perimetry testing with Octopus (SAP; Dynamic), Pulsar (PP; TOP) and Moorfields MDT (ESTA). Glaucoma was defined as progressive structural or functional loss (20 eyes). Perimetry test points were grouped into 6 sectors based on the estimated optic nerve head angle into which the associated nerve fiber bundle enters (Garway-Heath map). Perimetry summary measures (PSM) (MD SAP/ MD PP/ PTD MDT) were calculated from the average total deviation of each measured threshold from the normal for each sector. We calculated the 95% significance level of the sectorial PSM from the respective normative data. We calculated the percentage agreement with group1 (G1), healthy on HRT and within normal perimetric limits, and group 2 (G2), abnormal on HRT and outside normal perimetric limits. We also examined the relationship of PSM and rim area (RA) in those sectors classified as abnormal by MRA (Moorfields Regression Analysis) of HRT. Results: The mean age was 65 (range= [37, 89]). The global sensitivity versus specificity of each instrument in detecting glaucomatous eyes was: MDT 80% vs. 88%, SAP 80% vs. 80%, PP 70% vs. 89% and HRT 80% vs. 79%. Highest percentage agreement of HRT (respectively G1, G2, sector) with PSM were MDT (89%, 57%, nasal superior), SAP (83%, 74%, temporal superior), PP (74%, 63%, nasal superior). Globally percentage agreement (respectively G1, G2) was MDT (92%, 28%), SAP (87%, 40%) and PP (77%, 49%). Linear regression showed there was no significant trend globally associating RA and PSM. However, sectorally the supero-nasal sector had a statistically significant (p<0.001) trend with each instrument, the associated r2 coefficients are (MDT 0.38 SAP 0.56 and PP 0.39). Conclusions: There were no significant differences in global sensitivity or specificity between instruments. Structure-function relationships varied significantly between instruments and were consistently strongest supero-nasally. Further studies are required to investigate these relationships in detail.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Quitting smoking is associated with weight gain, which may threaten motivation to engage or sustain a quit attempt. The pattern of weight gained by smokers treated according to smoking cessation guidelines has been poorly described. We aimed to determine the weight gained after smoking cessation and its predictors, by smokers receiving individual counseling and nicotine replacement therapies for smoking cessation. METHODS: We performed an ancillary analysis of a randomized controlled trial assessing moderate physical activity as an aid for smoking cessation in addition to standard treatment in sedentary adult smokers. We used mixed longitudinal models to describe the evolution of weight over time, thus allowing us to take every participant into account. We also fitted a model to assess the effect of smoking status and reported use of nicotine replacement therapy at each time point. We adjusted for intervention group, sex, age, nicotine dependence, and education. RESULTS: In the whole cohort, weight increased in the first 3 months, and stabilized afterwards. Mean 1-year weight gain was 3.3kg for women and 3.9kg for men (p = .002). Higher nicotine dependence and male sex were associated with more weight gained during abstinence. Age over median was associated with continuing weight gain during relapse. There was a nonsignificant trend toward slower weight gain with use of nicotine replacement therapies. CONCLUSION: Sedentary smokers receiving a standard smoking cessation intervention experience a moderate weight gain, limited to the first 3 months. Older age, male sex, and higher nicotine dependence are predictors of weight gain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE Evaluate and correlate individual, work-related and organizational factors that influence adherence to standard precautions among nursing professionals of psychiatric hospitals in São Paulo. METHOD An exploratory cross-sectional study conducted with 35 nursing professionals, using the assessment tool for adherence to standard precautions through the Likert scale, ranging from 1 to 5. RESULTS Knowledge of the precautions received a high score (4.69); adherence received (3.86) and obstacles (3.78), while intermediaries and the scales of organizational factors received low scores (2.61). There was a strong correlation between the magnitude adherence scale and the personal protective equipment availability (r = 0.643; p = 0.000). The training scale for prevention of HIV exposure (p = 0.007) was statistically different between the nurses and nursing assistants. CONCLUSION The organizational factors negatively contributed to adherence to standard precautions, indicating that psychiatric institutions lack safe working conditions, ongoing training and management actions to control infections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper explores the effects of a standard influencing care choice. Firm(s) may increase the probability of offering safe products by incurring a cost. Under duopoly, they compete either in prices or in quantities. Under perfect information about safety for consumers, the selected standard that corrects a safety underinvestment is always compatible with competition. Safety over investment only emerges under competition in quantities and relatively low values of the cost. Under imperfect information about safety for consumers, the standard leads to a monopoly situation. However, for relatively large values of the cost, a standard cannot impede the market failure coming from the lack of information.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universal standard goniometer is an essential tool to measure articulations' range of motion (ROM). In this time of technological advances and increasing use of smartphones, new measurement's tools appear as specific smartphone applications. This article compares the iOS application "Knee Goniometer" with universal standard goniometer to assess knee ROM. To our knowledge, this is the first study that uses a goniometer application in a clinical context. The purpose of this study is to determine if this application could be used in clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Four standard radiation qualities (from RQA 3 to RQA 9) were used to compare the imaging performance of a computed radiography (CR) system (general purpose and high resolution phosphor plates of a Kodak CR 9000 system), a selenium-based direct flat panel detector (Kodak Direct View DR 9000), and a conventional screen-film system (Kodak T-MAT L/RA film with a 3M Trimax Regular screen of speed 400) in conventional radiography. Reference exposure levels were chosen according to the manufacturer's recommendations to be representative of clinical practice (exposure index of 1700 for digital systems and a film optical density of 1.4). With the exception of the RQA 3 beam quality, the exposure levels needed to produce a mean digital signal of 1700 were higher than those needed to obtain a mean film optical density of 1.4. In spite of intense developments in the field of digital detectors, screen-film systems are still very efficient detectors for most of the beam qualities used in radiology. An important outcome of this study is the behavior of the detective quantum efficiency of the digital radiography (DR) system as a function of beam energy. The practice of users to increase beam energy when switching from a screen-film system to a CR system, in order to improve the compromise between patient dose and image quality, might not be appropriate when switching from screen-film to selenium-based DR systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Oseltamivir phosphate (OP), the prodrug of oseltamivir carboxylate (OC; active metabolite), is marketed since 10 years for the treatment of seasonal influenza flu. It has recently received renewed attention because of the threat of avian flu H5N1 in 2006-7 and the 2009-10 A/H1N1 pandemic. However, relatively few studies have been published on OP and OC clinical pharmacokinetics. The disposition of OC and the dosage adaptation of OP in specific populations, such as young children or patients undergoing extrarenal epuration, have also received poor attention. An analytical method was thus developed to assess OP and OC plasma concentrations in patients receiving OP and presenting with comorbidities or requiring intensive care. Methods: A high performance liquid chromatography coupled to tandem mass spectrometry method (HPLC-MS/MS) requiring 100-µL aliquot of plasma for quantification within 6 min of OP and OC was developed. A combination of protein precipitation with acetonitrile, followed by dilution of supernant in suitable buffered solvent was used as an extraction procedure. After reverse phase chromatographic separation, quantification was performed by electro-spray ionization-triple quadrupole mass spectrometry. Deuterated isotopic compounds of OP and OC were used as internal standards. Results: The method is sensitive (lower limit of quantification: 5 ng/mL for OP and OC), accurate (intra-/inter-assay bias for OP and OC: 8.5%/5.5% and 3.7/0.7%, respectively) and precise (intra-/inter-assay CV%: 5.2%/6.5% and 6.3%/9.2%, respectively) over the clinically relevant concentration range (upper limits of quantification 5000 ng/mL). Of importance, OP, as in other previous reports, was found not to be stable ex vivo in plasma on standard anticoagulants (i.e. EDTA, heparin or citrate). This poor stability of OP has been prevented by collecting blood samples on commercial fluoride/oxalate tubes. Conclusions: This new simple, rapid and robust HPLC-MS/MS assay for quantification of OP and OC plasma concentrations offers an efficient tool for concentration monitoring of OC. Its exposure can probably be controlled with sufficient accuracy by thorough dosage adjustment according to patient characteristics (e.g. renal clearance). The usefulness of systematic therapeutic drug monitoring in patients appears therefore questionable. However, pharmacokinetic studies are still needed to extend knowledge to particular subgroups of patients or dosage regimens.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractText BACKGROUND: Profiling sperm DNA present on vaginal swabs taken from rape victims often contributes to identifying and incarcerating rapists. Large amounts of the victim's epithelial cells contaminate the sperm present on swabs, however, and complicate this process. The standard method for obtaining relatively pure sperm DNA from a vaginal swab is to digest the epithelial cells with Proteinase K in order to solubilize the victim's DNA, and to then physically separate the soluble DNA from the intact sperm by pelleting the sperm, removing the victim's fraction, and repeatedly washing the sperm pellet. An alternative approach that does not require washing steps is to digest with Proteinase K, pellet the sperm, remove the victim's fraction, and then digest the residual victim's DNA with a nuclease. METHODS: The nuclease approach has been commercialized in a product, the Erase Sperm Isolation Kit (PTC Labs, Columbia, MO, USA), and five crime laboratories have tested it on semen-spiked female buccal swabs in a direct comparison with their standard methods. Comparisons have also been performed on timed post-coital vaginal swabs and evidence collected from sexual assault cases. RESULTS: For the semen-spiked buccal swabs, Erase outperformed the standard methods in all five laboratories and in most cases was able to provide a clean male profile from buccal swabs spiked with only 1,500 sperm. The vaginal swabs taken after consensual sex and the evidence collected from rape victims showed a similar pattern of Erase providing superior profiles. CONCLUSIONS: In all samples tested, STR profiles of the male DNA fractions obtained with Erase were as good as or better than those obtained using the standard methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acute myocarditis was until recently one of the most difficult diagnoses in cardiology. The spectrum of signs and symptoms is very wide, the usual non-invasive tests lack specificity and the myocardial biopsy is only performed in a minority of cases to confirm the diagnosis. Due to its unique ability to directly image myocardial necrosis, fibrosis and oedema, cardiac magnetic resonance (CMR) is now considered the primary tool for noninvasive assessment of patients with suspected myocarditis. CMR is also useful for monitoring disease activity under treatment. Myocarditis has been associated with the development of dilated cardiomyopathy; CMR could play a role in the follow-up of such cases to detect the progression toward a dilatative phenotype. Precise mapping of myocardial lesions with cardiac MRI is invaluable to guide myocardial biopsy and increase its diagnostic yield by improving sensitivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The practice of sedation, including monitoring practice for digestive endoscopy, continues to evolve throughout the world. In many countries, including Switzerland, there is a trend towards increased utilization of sedation during both routine and advanced endoscopic procedures. Sedation improves patient satisfaction with endoscopy and also improves the quality of the examination. In addition, a trend can be observed towards an increasing use of propofol as the preferred sedative drug. Here we review the latest published data from surveys describing sedation and monitoring practice in different countries and compare them with our own data from successive nationwide surveys among Swiss gastroenterologists over a period of 20 years. This development between these socioeconomically very similar Western industrialized countries, however, shows some unique and surprising differences. In Germany and Switzerland, propofol use has become increasingly widespread, in Switzerland even to the extent that during the last few years propofol has overtaken benzodiazepine sedation, with an absolute majority of Swiss gastroenterologists using it without the assistance of an anesthesiologist. In addition, the change in Switzerland reflects a successful generalization of nonanesthesiologist-administered propofol (NAAP) sedation from the hospital setting to private practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A list of 681 UBVRI secondary standard stars for CCD photometry is presented. Visual magnitude ranges from 9.7 to 19.4, and the B-V colour index varies from 1.15 to 1.97. The stars are grouped into 11 different fields, each of them is generally observable in a single CCD frame. The stars are located near Landolt UBVRI equatorial standards, accessible to telescopes in both hemispheres, and mainly within the 5 - 8 hours range of right ascension. Photometry, equatorial coordinates and finding charts are provided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[eng] ISO standard 9001 is one of a set of management tools that libraries have adopted in recent years. This article focuses on libraries in higher education institutions that have received ISO certification of their quality management systems (ISO standard 9001:2000). We examine their reasons for seeking certification and the advantages and difficulties they have encountered in applying this ISO standard. Finally, we consider the future prospects of ISO standard 9001 in university libraries.