891 resultados para cornea stroma
Resumo:
Purpose: To report a very successful outcome obtained with the fitting of a new-generation hybrid contact lens of reverse geometry in a thin cornea with extreme irregularity due to the presence of a central island after unsuccessful myopic excimer laser refractive surgery. Methods: A 32-year-old man attended to our clinic complaining of very poor vision in his right eye after bilateral laser in situ keratomileusis (treatment or surgery) for myopia correction and some additional retreatments afterward. After a comprehensive ocular evaluation, contact lens fitting with a reverse geometry hybrid contact lens (SynergEyes PS, SynergEyes, Carlsbad, CA) was proposed as a solution for this case. Visual, refractive, and ocular aberrometric outcomes with the contact lens were evaluated. Results: Distance visual acuity improved from a prefitting uncorrected value of 20/200 to a postfitting corrected value of 20/16. Prefitting manifest refraction was +6.00 sphere and −3.00 cylinder at 70°, with a corrected distance visual acuity of 20/40. Higher order root mean square for a 5-mm pupil changed from a prefitting value of 1.45 to 0.34 µm with the contact lens. The contact lens wearing was reported as comfortable, and the patient was very satisfied with this solution. Conclusions: The SynergEyes PS contact lens seems to be an excellent option for the visual rehabilitation of corneas with extreme irregularity after myopic excimer laser surgery, minimizing the level of higher order aberrations and providing an excellent visual outcome.
Resumo:
Marca tipográfica en la portada.
Resumo:
Mode of access: Internet.
Resumo:
Mode of access: Internet.
Resumo:
Mode of access: Internet.
Resumo:
Background: Encapsulation in hepatocellular carcinoma is associated with decreased invasiveness and improved survival in several series. Although active fibrogenesis by myofibroblasts has been demonstrated in the capsule, it is unclear if the capsule results from a general increase in peritumoral fibrosis, or an inherently less invasive tumor phenotype. The relationship between collagen deposition within tumor stroma, presence of cirrhosis and invasiveness also needs clarification. Methods: We performed immunohistochemistry for collagens I, III, IV and VI on sections of encapsulated and non-encapsulated hepatocellular carcinoma, arising in cirrhotic and non-cirrhotic livers. Staining was graded semi-quantitatively in tumor stromal elements and adjacent parenchymal sinusoids. The relationship of this staining with encapsulation, cirrhosis, and vascular invasion was analyzed. Results: Formation of a discrete capsular layer was associated with reduced vascular invasion, but not with a pervasive increase in peritumoral fibrosis. Increased collagen I content of tumor stroma and adjacent parenchymal sinusoids was associated with non-encapsulated tumors and vascular invasion. The presence of cirrhosis had little effect on capsule composition. Conclusions: Encapsulation of hepatocellular carcinoma reflects reduced invasiveness, rather than increased peritumoral collagen synthesis, which may instead enhance invasion. Increased intratumoral collagen I protein is also associated with increased tumor invasiveness. Pre-existing cirrhosis has little effect on tumor progression, possibly because the characteristics of cirrhosis are overwhelmed by tumor-induced changes in the adjacent parenchyma.(C) 2003 Blackwell Publishing Asia Pty Ltd.
Resumo:
This paper is aimed at establishing a particular chronological priority issue in the convoluted history of artificial cornea. According to existing records, the first keratoprosthesis made from polyurethane was developed by Caldwell and Jacob-Labarre in the late 1980s. This paper demonstrates that in fact the first polyurethane keratoprosthesis was proposed and designed in 1985 by Lawrence Hirst, an Australian ophthalmologist then working in St Louis, USA. The first prototype was manufactured in January 1986 by Thermedics Inc according to Dr Hirst's instructions from Tecoflex, a transparent polyurethane developed by the same company. This keratoprosthesis, which also had a porous skirt, was inserted intralamellarly in a monkey cornea and followed up clinically for about 3 months. There were no significant postoperative complications, and the histology of the explant indicated proper biointegration of the prosthetic skirt within the host stromal tissue. Because of a delay in the manufacture of further prototypes and to Dr Hirst's decision to return to Australia, the project was eventually abandoned. As no report was published on this development, the present paper is entirely based on original documents held in Dr Hirst's archives.
Resumo:
We assess the accuracy of the Visante anterior segment optical coherence tomographer (AS-OCT) and present improved formulas for measurement of surface curvature and axial separation. Measurements are made in physical model eyes. Accuracy is compared for measurements of corneal thickness (d1) and anterior chamber depth (d2) using-built-in AS-OCT software versus the improved scheme. The improved scheme enables measurements of lens thickness (d 3) and surface curvature, in the form of conic sections specified by vertex radii and conic constants. These parameters are converted to surface coordinates for error analysis. The built-in AS-OCT software typically overestimates (mean±standard deviation(SD)]d1 by +62±4 μm and d2 by +4±88μm. The improved scheme reduces d1 (-0.4±4 μm) and d2 (0±49 μm) errors while also reducing d3 errors from +218±90 (uncorrected) to +14±123 μm (corrected). Surface x coordinate errors gradually increase toward the periphery. Considering the central 6-mm zone of each surface, the x coordinate errors for anterior and posterior corneal surfaces reached +3±10 and 0±23 μm, respectively, with the improved scheme. Those of the anterior and posterior lens surfaces reached +2±22 and +11±71 μm, respectively. Our improved scheme reduced AS-OCT errors and could, therefore, enhance pre- and postoperative assessments of keratorefractive or cataract surgery, including measurement of accommodating intraocular lenses. © 2007 Society of Photo-Optical Instrumentation Engineers.
Resumo:
Bilateral corneal blindness represents a quarter of the total blind, world-wide. The artificial cornea in assorted forms, was developed to replace opaque non-functional corneas and to return sight in otherwise hopeless cases that were not amenable to corneal grafts; believed to be 2% of corneal blind. Despite technological advances in materials design and tissue engineering no artificial cornea has provided absolute, long-term success. Formidable problems exist, due to a combination of unpredictable wound healing and unmanageable pathology. To have a solid guarantee of reliable success an artificial cornea must possess three attributes: an optical window to replace the opaque cornea; a strong, long term union to surrounding ocular tissue; and the ability to induce desired host responses. A unique artificial cornea possesses all three functional attributes- the Osteo-odonto-keratoprosthesis (OOKP). The OOKP has a high success rate and can survive for up to twenty years, but it is complicated both in structure and in surgical procedure; it is expensive and not universally available. The aim of this project was to develop a synthetic substitute for the OOKP, based upon key features of the tooth and bone structure. In doing so, surgical complexity and biological complications would be reduced. Analysis of the biological effectiveness of the OOKP showed that the structure of bone was the most crucial component for implant retention. An experimental semi-rigid hydroxyapatite framework was fabricated with a complex bone-like architecture, which could be fused to the optical window. The first method for making such a framework, was pressing and sintering of hydroxyapatite powders; however, it was not possible to fabricate a void architecture with the correct sizes and uniformity of pores. Ceramers were synthesised using alternative pore forming methods, providing for improved mechanical properties and stronger attachment to the plastic optical window. Naturally occurring skeletal structures closely match the structural features of all forms of natural bone. Synthetic casts were fabricated using the replamineform process, of desirable natural artifacts, such as coral and sponges. The final method of construction by-passed ceramic fabrication in favour of pre-formed coral derivatives and focused on methods for polymer infiltration, adhesion and fabrication. Prototypes were constructed and evaluated; a fully penetrative synthetic OOKP analogue was fabricated according to the dimensions of the OOKP. Fabrication of the cornea shaped OOKP synthetic analogue was also attempted.
Resumo:
The study investigated the central and peripheral corneal characteristics of groups of subjects from 20 to 90 years of age to assist the understanding of ageing changes in the cornea, and to see whether relationships between ocular parameters were revealed. After age 45 the corneal horizontal radius of curvature gradually decreased with age. This trend was shown by the Aston University subjects (group B). The effect was very significant for the hospital patients undergoing biometry before cataract extraction operation (group D). Vertical radius of curvature showed a slight decrease with age after age 45, but similar to corneal eccentricity, this showed no significant age effect. Corneal astigmatism progressed from with the rule towards against the rule, particularly after age 60. The shift seemed mainly due to the decreasing horizontal corneal curvature. In biometry no significant age relation was found for axial length, but a significant relation was found between curvature and axial length in the larger group D. Lens thickness showed a very significant relation to age and to axial length, but no significant relation to corneal curvature. Anterior chamber depth showed a very significant relation to age, lens thickness and axial length, but no significant relation to corneal curvature. A significant age effect was found for corneal thickness decreasing with age for the central, nasal and temporal regions of the right eye. Analysis of the biometry results indicated the influence of two major factors. Firstly, the natural growth of the eye in youth, leading to greater values of axial length, radius of corneal curvature, lens thickness and anterior chamber depth. Secondly, the typical ageing changes where the increasing lens thickness caused a reduction in anterior chamber depth. The decrease in corneal thickness with age shown in some corneal regions may be a sign of ageing changes in the tissue proteins and hydration balance.
Resumo:
Purpose: We have reported that the changes in the pupillary shape in response to electrical stimulation of the branches of the ciliary nerves in cats. (Miyagawa et al. PLoS One, 2014). This study investigates the changes in the pupillary shapes in response to electrical stimulations of the sclera of peripheral cornea in cats and porcines. Methods: Two enucleated eyes of two cats and three enucleated porcine eyes were studied. Trains of biphasic pulses (current, 3 mA; duration, 2 ms/phase; frequency, 40 Hz) were applied using a tungsten electrode (0.3mm diameter). The stimulation was performed at every 45 degree over the entire circular region on the sclera near the cornea. The pupillary images were recorded before and 4 s (cat) and 10 s (pig) after the stimulation and the change in the pupil diameter (Δr) was quantified. The pupillary images were obtained with a custom-built compact wavefront aberrometer (Uday et al. J Cataract Refract Surg, 2013). Results: In a cat eye, the pupil was dilated by the electrical stimulation at six out of eight orientations (before stimulation pupil diameter r=10.10±0.49 mm, Δr=0.33±0.12 mm). The pupil dilated only toward the electrode (relative eccentricity of the pupil center to the pupil diameter change amount rdec=1.15±0.28). In the porcine eyes, the pupils were constricted by the electrical stimulations at the temporal and nasal orientations (r=10.04±0.57 mm, Δr=1.52±0.70 mm). The pupils contracted symmetrically (rdec=0.30±0.12). Conclusions: With electrical stimulation in the sclera of the peripheral cornea, asymmetric mydriasis in cat eyes and symmetrical miosis in porcine eyes were observed. Under the assumption that the electrical stimulation stimulated both muscles that contribute to the pupil control, our hypothesis proposed here is that the pupil dilator is stronger than the pupil sphincter in cat, and pupil sphincter is stronger than pupil dilator in porcine.
Resumo:
Purpose: We have reported that the changes in the accommodative response to electrical stimulation of the branches of the ciliary nerves in cats. (Miyagawa et al, PLoS One, 2014). We have also reported that no robust accommodative responses to the electrical stimulations of the sclera of peripheral cornea (SSPC) were observed in enucleated porcine eyes (Mihashi et al, VPOptics, 2014). In this study, accommodative responses to SSPC stimulation in cats and porcines were investigated. Methods: Two eyes of two cats under anesthesia and after they were sacrificed were studied. Three enucleated porcine eyes obtained from a local slaughterhouse were also studied. Trains of biphasic pulses (current, 3 mA; duration, 2 ms/phase; frequency, 40 Hz) were applied using a tungsten electrode (0.3mm diameter) from several orientations. Wavefront sensing with a compact wavefront aberrometer (Uday et al J Cataract Refract Surg, 2013) were performed before and 4 s (cat) and 10 s (pig) after the stimulations and wavefront aberrations including spherical errors were analyzed over a 4-mm pupil area. Results: In the first cat under anesthesia, at three out of seven stimulus positions, 0.2 D hyperopic accommodative responses were observed and in two orientations, myopic responses were observed. For the other cat, weak accommodative responses including astigmatic changes were observed. In the sacrificed condition of the second cat, 0.1 D myopic response was observed for one stimulus orientation and the smaller responses were observed at six out of eight stimulus positions. No accommodative responses were elicited for the enucleated porcine eyes. Conclusions: In the anesthetized cats, electrical stimulation of the SSPC induced accommodative responses; the responses were unstable and weaker than the responses by the ciliary nerve stimulations we observed in our previous study. Small accommodative responses were observed after one of two cats had been sacrificed, but no accommodative responses were detected in the enucleated porcine eyes. Further studies are needed to confirm difference in the accommodation functions in the two species.
Resumo:
Pancreatic ductal adenocarcinoma (PDAC) is a lethal cancer in part due to inherent resistance to chemotherapy, including the first-line drug gemcitabine. Gemcitabine is a nucleoside pyrimidine analog that has long been the backbone of chemotherapy for PDAC, both as a single agent, and more recently, in combination with nab-paclitaxel. Since gemcitabine is hydrophilic, it must be transported through the hydrophobic cell membrane by transmembrane nucleoside transporters. Human equilibrative nucleoside transporter-1 (hENT1) and human concentrative nucleoside transporter-3 (hCNT3) both have important roles in the cellular uptake of the nucleoside analog gemcitabine. While low expression of hENT1 and hCNT3 has been linked to gemcitabine resistance clinically, mechanisms regulating their expression in the PDAC tumor microenvironment are largely unknown. We identified that the matricellular protein Cysteine-Rich Angiogenic Inducer 61 (CYR61) negatively regulates expression of hENT1 and hCNT3. CRISPR/Cas9-mediated knockout of CYR61 significantly increased expression of hENT1 and hCNT3 and cellular uptake of gemcitabine. CRSIPR-mediated knockout of CYR61 sensitized PDAC cells to gemcitabine-induced apoptosis. Conversely, adenovirus-mediated overexpression of CYR61 decreased hENT1 expression and reduced gemcitabine-induced apoptosis. We demonstrate that CYR61 is expressed primarily by stromal pancreatic stellate cells (PSCs) within the PDAC tumor microenvironment, with Transforming Growth Factor- β (TGF-β) inducing the expression of CYR61 in PSCs through canonical TGF-β-ALK5-Smad signaling. Activation of TGF-β signaling or expression of CYR61 in PSCs promotes resistance to gemcitabine in an in vitro co-culture assay with PDAC cells. Our results identify CYR61 as a TGF-β induced stromal-derived factor that regulates gemcitabine sensitivity in PDAC and suggest that targeting CYR61 may improve chemotherapy response in PDAC patients.
Resumo:
La cornée est la couche la plus antérieure de l’oeil et sa transparence permet de laisser passer les ondes lumineuses vers la rétine. Cependant, la localisation de la cornée la prédispose à des blessures chimiques et mécaniques. La guérison des blessures cornéennes est un mécanisme complexe faisant intervenir la mort cellulaire, la migration, la prolifération, la différenciation et le remodelage de la matrice extracellulaire (MEC). Dans cette étude, nous avons utilisé la cornée humaine reconstruite par génie tissulaire composée d’un épithélium et d’un stroma afin d’étudier les mécanismes cellulaires et moléculaires de la guérison des plaies, en particulier le remodelage de la MEC exercé par les métalloprotéinases matricielles (MMPs). Les analyses en profilage génique sur biopuces à ADN nous ont permis de démontrer que l’expression de plusieurs gènes était dérégulée lors de la guérison des plaies dans notre modèle. L’expression des gènes codant pour les MMPs, tel que confirmée en qPCR, est augmentée dans l’épithélium migrant afin de recouvrir la plaie. Les analyses en zymographie sur gel ont démontré que les MMPs étaient converties en leur forme enzymatiquement active au fur et à mesure que la lésion se referme. Par ailleurs, nous avons démontré que l’expression des MMPs par les cellules épithéliales est influencée par la présence des fibroblastes dans le stroma ainsi que par leur sécrétion d’une MEC enrichie en collagènes. De plus, les analyses en spectrométrie de masse ont confirmé que la présence d’un épithélium stratifié est requise pour la synthèse et l’organisation adéquate de la MEC. Enfin, les résultats de ces travaux améliorent nos connaissances des mécanismes cellulaires et moléculaires qui modulent la guérison des plaies cornéennes et pourront certainement mener à des progrès en clinique, notamment au niveau du développement de thérapies visant à traiter les troubles de la cornée.
Resumo:
Le stress oxydatif peut provenir de sources exogènes comme les UVA ou de sources endogènes comme la chaîne respiratoire (OXPHOS). L’oxydation des composants cellulaires a été associée avec la dégénération, des phénotypes de vieillissement et des pertes de fonctionnalités des tissus. Les UVA sont les plus efficaces des rayons UV à induire de l’oxydation, tel que démontré par la formation de dommages oxydatifs à l’ADN et par l’apparition de délétions mitochondriales qui en résultent. La délétion mitochondriale de 4977 pb (ADNmtCD4977), la plus commune, et celle de 3895 pb (ADNmt3895) sont deux délétions reliées au photovieillissement cutané et à l’exposition au stress oxydant. Le phénomène de vieillissement dans la peau est bien documenté et se traduit par une dégradation de la matrice extracellulaire, une perte d’élasticité et la formation de rides. Toutefois, peu d’études portent sur la cornée humaine alors qu’elle est un tissu exposé directement aux rayonnements UV au même titre que la peau. Nous avons donc tenté mieux comprendre l’effet de l’oxydation exogène et endogène sur cette structure. L’analyse de la localisation des délétions ADNmtCD4977 et ADNmtCD4977 dans l’oeil humain a permis de révéler qu’elles se concentrent principalement dans le stroma cornéen et s’accumule avec l’âge. Le stroma cornéen est la couche cellulaire qui confère la transparence et la rigidité à la cornée humaine. Ces résultats nous ont suggéré une implication des UVA dans le photovieillissement de la cornée. Nous avons donc entrepris de vérifier les changements liés à l’exposition aux UVA dans le stroma cornéen puisque les UVA sont connus pour causer des altérations à la matrice extracellulaire (ECM) au niveau cutané. Nous avons donc créé un modèle de photovieillisement par une exposition chronique aux UVA sur des kératocytes avec lesquels nous avons fait sécréter une ECM. Nos résultats nous ont démontré qu’une exposition chronique aux UVA cause des altérations à l’ECM cornéen semblable à des phénotypes de photvieillissement. En effet, nous avons dénoté des changements transcriptomiques et protéomiques pour certains collagènes et protéoglycans. Une atteinte aux collagènes par le vieillissement cornéen se traduit entre autres par une rigidification, une opacification et un changement dans son pouvoir réfractif qui mène à une perte de la vision. Par ailleurs, notre avons également investigué l’implication du stress oxydatif dans la dystrophie cornéenne endothéliale de Fuchs (FECD), une maladie dégénérative de l’endothélium cornéen, qui mène à une perte de vision et est une cause principale de greffe cornéenne. L’étiologie de la maladie est encore inconnue, mais le stress oxydatif est soupçonné de jouer un rôle important dans la pathogenèse. Nos résultats ont amené de nouvelles évidences de l’implication de l’oxydation dans la maladie par l’augmentation de la quantité d’ADN mitochondrial et un raccourcissement des télomères dans des explants de cornées pathologiques. Nos résultats nous ont également démontré que la mise en culture de cellules FECD permettait la sélection de cellules fonctionnelles et comparables à des cellules saines en termes de quantité d’ADN mitochondrial et de son intégrité, de sensibilité à l’oxydation et de longueur télomérique. Les résultats obtenus soutiennent ainsi la possibilité d’employer les cellules FECD fonctionnelles sélectionnées pour utilisation en génie tissulaire afin de créer des cornées autologues pour pallier aux manques de greffes cornéennes. Enfin, nos résultats apportent de nouvelles évidences quant à l’implication du stress oxydatif dans le photovieillissement cornéen et dans l’étiologie de la FECD.