1000 resultados para constante dielétrica
Resumo:
The plasma produced by Dielectric Barrier Discharge (DBD) is a promising technique for producing plasma in atmospheric pressure and has been highlighted in several areas, especially in biomedical and textile industry, this is due to the fact that the plasma generated by DBD not reaches high temperatures, enabling use it for thermally sensitive materials. But still it is necessary the development of research related to understanding of the chemical, physical and biological interaction between the non-thermal plasma at atmospheric pressure with cells, tissues, organs and organisms. This work proposes to develop equipment DBD and characterize it in order to obtain a better understanding of the process parameters of plasma production and how it behaves under the parameters adopted in the process, such as distance, frequency and voltage applied between electrodes. For this purpose two techniques were used to characterize distinct from each other. The first was the method of Lissajous figures, this technique is quite effective and accurately for complete electrical characterization equipment DBD. The second technique used was Optical Emission Spectroscopy (EEO) very effective tool for the diagnosis of plasma with it being possible to identify the excited species present in the plasma produced. Finally comparing the data obtained by the two techniques was possible to identify a set of parameters that optimize the production when combined DBD plasma atmosphere in the equipment was built precisely in this condition 0.5mm-15kV 600Hz, giving way for further work
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
JUSTIFICATIVA E OBJETIVOS: A manutenção de concentração sangüínea alvo-controlada em níveis aproximadamente constantes do propofol é uma técnica que pode ser empregada de modo simplificado na sala de cirurgia. A finalidade desta pesquisa é comparar clínica e laboratorialmente a infusão de propofol em crianças usando os atributos farmacocinéticos de Short e de Marsh. MÉTODO: Foram estudados 41 pacientes com a idade de 4 a 12 anos, de ambos os sexos, estado físico ASA I ou II, distribuídos em dois grupos S (20 pacientes) e M (21 pacientes). No Grupo S utilizaram-se os atributos farmacocinéticos de Short, e no Grupo M, os atributos farmacocinéticos de Marsh. A indução anestésica foi feita com bolus de alfentanil 30 µg.kg-1, propofol 3 mg.kg-1 e pancurônio, 0,08 mg.kg-1 por via venosa. Procedeu-se a intubação traqueal e a manutenção com N2O/O2 (60%) em ventilação controlada mecânica. No grupo S a infusão de propofol foi de 254 (30 min) seguido de 216 µg.kg-1.min-1 por mais 30 min. No grupo M a infusão de propofol foi de 208 (30 min) seguido de 170 µg.kg-1.min-1 por mais 30 min. Através do atributo farmacocinético específico a cada grupo a meta foi a obtenção da concentração-alvo de 4 µg.kg-1 de propofol. Foram colhidas três amostras sangüíneas (aos 20, 40 e 60 minutos) para a dosagem do propofol pelo método da Cromatografia Líquida de Alta Performance. RESULTADOS: Os Grupos S e M foram considerados similares quanto à idade, altura, peso e sexo (p > 0,05). Não houve diferença estatística significativa entre os dois grupos estudados para os parâmetros: PAS, PAD, FC, FiN2O, SpO2 da hemoglobina e P ET CO2 no final da expiração. A comparação entre grupos no número de bolus repetidos de alfentanil não foi estatisticamente significativa. O índice bispectral (BIS) não apresentou diferença estatisticamente significativa entre M0 (vigília) e os demais momentos em ambos os grupos. Os valores Medianos da Performance do Erro (MPE) e os valores Medianos Absolutos da Performance do Erro (MAPE) mostraram diferenças estatísticas significativas entre os grupos no momento 60. Valores medianos da concentração sangüínea de propofol (µg.kg-1) mostraram diferenças estatísticas significativas entre M e S no momento 60 e entre os momentos 40 e 60 no grupo S. CONCLUSÕES: A anestesia com propofol usando os atributos farmacocinéticos de Marsh (Grupo M) apresentou menor erro no cálculo da concentração-alvo de propofol de 4 µg.kg-1. Além disso, utiliza menor quantidade de propofol para obter resultados clínicos semelhantes. Por todas essas qualidades deve ser a preferida para uso em crianças ASA I e com idades entre 4 e 12 anos.
Resumo:
Purpose - To evaluate the influence of sustained elevations of arterial pressure on dP/dt values, which the left ventricular end diastolic pressure was kept constant. Methods - Thirteen anesthetized dogs, mechanically ventilated and submitted to thoracotomy and pharmacological autonomic block (atropine - 0.5 mg/kg IV + oxprenolol - 3 mg/kg IV) were studied. The arterial pressure elevation was obtained by mechanical constriction of the descending thoracic aorta. Analyses were made in control (C) situation and after two successives increments of arterial pressure, sustained for 10min, called hypertension 1 (H1) and hypertension 2 (H2), respectively. The end diastolic left ventricular pressure was kept constant by utilization of a perfusion system connected to the left atria. Results - Heart rate did not change (C: 125 ± 13.9bpm; H1: 125 ± 13.5bpm; H2: 123 ± 14.1bpm; p > 0.05); the LVSP increased (C: 119 ± 8.1mmHg; H1: 142 ± 7.9mmHg; H2: 166 ± 7.7mmHg; p < 0.01); the AoDP increased (C: 89 ± 11.6mmHg; H1: 99 ± 9.5mmHg; H2: 120 ± 11.8mmHg; p < 0.01); the LVEDP (C: 6.2 ± 2.48mmHg; H1: 6.3 ± 2.43mmHg; H2: 6.1 ± 2.51mmHg; p > 0.05) and the dP/dt (C: 3068 ± 1057.1mmHg/s; 3112 ± 995.7mmHg/s; H2: 3086 ± 979.5mmHg/s; p > 0.05) did not change. Conclusion - dP/dt values are not influenced by a sustained elevation of arterial pressure, when the end diastolic left ventricular pressure is kept constant.
Resumo:
The experiment was carried out at Piracicaba, São Paulo, Brazil, from January to February 1993, with the objective of evaluating the behavior responses of Holstein cows, with constant or limited access to shade. The experimental design used was completely randomized. Twenty four dairy cows were used, at different lactation stages and production levels, kept in two free stall barns, with or without protection against solar radiation in south-east and north-west edge. The behavior parameters studied were: alimentation, rumination, rest time and frequency and water ingestion frequency. The protection of the free stall barn didn't affect the behavior responses. The alimentation, rumination and rest time, daily, were 3.4, 7.0 e 9.0 hours, respectively. The highest alimentation frequencies were before and after milking. The rumination was mainly during nocturnal period; the rest was more frequent during the period with higher solar radiation. The animals stayed more time in the shelter (13.4 vs 2.5 h/day). The highest daily water ingestion frequencies were in the hot time and next milking, mainly.
Resumo:
The main purpose of this study was to analyze the effect of the pedaling cadence (500 × 100 rpm) on the heart rate (HR) and the blood lactate response during incremental and constant workload exercises in active individuals. Nine active male individuals (20.9 ± 2.9 years old; 73.9 ± 6.5 kg; 1.79 ± 0.9 m) were submitted to two incremental tests, and to 6-8 constant workload tests to determine the intensity corresponding to the maximal steady state lactate (MLSSintens) in both cadences. The maximal power (Pmax) attained during the incremental test, and the MLSSintens were significantly lower at 100 rpm (240.9 ± 12.6 W; 148.1 ± 154.W) compared to 50 rpm (263.9 ± 18.6 W; 186.1 ± 21.2 W), respectively. The HRmax did not change between cadences (50 rpm = 191.1 ± 8.8 bpm; 100 rpm = 192.6 ± 9.9 bpm). Regardless the cadence, the HRmax percentage (70, 80, 90, and 100%) determined the same lactate concentrations during the incremental test. However, when the intensity was expressed in Pmax percentage or in absolute power, the lactate and the HR values were always higher at highest cadences. The HR corresponding to MLSSintens was similar between cadences (50 rpm = 162.5 ± 9.1 bpm; 100 rpm = 160.4 ± 9.2 bpm). Based on these results, it can be conclude that regardless the cadence employed (50 × 100 rpm), the use of the HR to individualize the exercise intensity indicates similar blood lactate responses, and this relationship is also kept in the exercise of constant intensity performed at MLSSintens. On the other hand, the use of the Pmax percentages depend on the cadence used, indicating different physiological responses to a same percentage.
Resumo:
Incluye Bibliografía
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Biotecnologia - IQ
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Educação Escolar - FCLAR
Resumo:
Incluye Bibliografía
Resumo:
Incluye Bibliografía