880 resultados para chromatographic separation
Resumo:
A simple method for the measurement of the active leflunomide metabolite A77 1726 in human plasma by HPLC is presented. The sample workup was simple, using acetonitrile for protein precipitation. Chromatographic separation of A77 1726 and the internal standard, alpha-phenylcinnamic acid, was achieved using a C-18 column with UV detection at 305 nm. The assay displayed reproducible linearity for A77 1726 with determination coefficients (r(2)) > 0.997 over the concentration range 0.5-60.0 mug/ml. The reproducibility (%CV) for intra- and inter-day assays of spiked controls was
Resumo:
A chromatographic method was developed for the determination of tryptophan content in food and feed proteins. The method involves separation and quantitation of tryptophan (released from protein by alkaline hydrolysis with NaOH) by isocratic ion-exchange chromatography with O-phthalaldehyde derivatization followed by fluorescence detection. In this procedure, chromatographic separation of the tryptophan and alpha-methyl tryptophan, the internal standard, was complete in 15 min, without any interference from other compounds. The precision of the method was 1-4%, relative standard deviation. Accuracy was validated by agreement with the value for chicken egg white lysozyme, a sequenced protein, and by quantitative recoveries after spiking with lysozyme. The method allows determination in a range of feed proteins, containing varied concentrations of tryptophan, and is applicable to systems used for routine amino acid analysis by ion-exchange chromatography. (C) 2004 Elsevier Ltd. All rights reserved.
Resumo:
High-performance liquid chromatography coupled by an electrospray ion source to a tandem mass spectrometer (HPLC-EST-MS/ MS) is the current analytical method of choice for quantitation of analytes in biological matrices. With HPLC-ESI-MS/MS having the characteristics of high selectivity, sensitivity, and throughput, this technology is being increasingly used in the clinical laboratory. An important issue to be addressed in method development, validation, and routine use of HPLC-ESI-MS/MS is matrix effects. Matrix effects are the alteration of ionization efficiency by the presence of coeluting substances. These effects are unseen in the chromatograrn but have deleterious impact on methods accuracy and sensitivity. The two common ways to assess matrix effects are either by the postextraction addition method or the postcolumn infusion method. To remove or minimize matrix effects, modification to the sample extraction methodology and improved chromatographic separation must be performed. These two parameters are linked together and form the basis of developing a successful and robust quantitative HPLC-EST-MS/MS method. Due to the heterogenous nature of the population being studied, the variability of a method must be assessed in samples taken from a variety of subjects. In this paper, the major aspects of matrix effects are discussed with an approach to address matrix effects during method validation proposed. (c) 2004 The Canadian Society of Clinical Chemists. All rights reserved.
Resumo:
A review of the general chromatographic theory and of continuous chromatographic techniques has been carried out. Three methods of inversion of sucrose to glucose and fructose in beet molasses were explored. These methods were the inversion of sucrose using the enzyme invertase, by the use of hydrochloric acid and the use of the resin Amberlite IR118 in the H+ form. The preferred method on economic and purity considerations was by the use of the enzyme invertase. The continuous chromatographic separation of inverted beet molasses resulting in a fructose rich product and a product containing glucose and other non-sugars was carried out using a semi-continuous counter-current chromatographic refiner (SCCR6), consisting of ten 10.8cm x 75cm long stainless steel columns packed with a calcium charged 8% cross-linked polystyrene resin Zerolit SRC 14. Based on the literature this is the first time such a continuous separation has been attempted. It was found that the cations present in beet molasses displaced the calcium ions from the resin resulting in poor separation of the glucose and fructose. Three methods of maintaining the calcium form of the resin during the continuous operation of the equipment were established. Passing a solution of calcium nitrate through the purge column for half a switch period was found to be most effective as there was no contamination of the main fructose rich product and the product concentrations were increased by 50%. When a 53% total solids (53 Brix) molasses feedstock was used, the throughput was 34.13kg sugar solids per m3 of resin per hour. Product purities of 97% fructose in fructose rich (FRP) and 96% glucose in the glucose rich (GRP) products were obtained with product concentrations of 10.93 %w/w for the FRP and 10.07 %w/w for the GRP. The effects of flowrates, temperature and background sugar concentration on the distribution coefficients of fructose, glucose, betaine and an ionic component of beet molasses were evaluated and general relationships derived. The computer simulation of inverted beet molasses separations on an SCCR system has been carried out successfully.
Resumo:
An increasing number of publications on the dried blood spot (DBS) sampling approach for the quantification of drugs and metabolites have been spurred on by the inherent advantages of this sampling technique. In the present research, a selective and sensitive high-performance liquid chromatography method for the concurrent determination of multiple antiepileptic drugs (AEDs) [levetiracetam (LVT), lamotrigine (LTG), phenobarbital (PHB)], carbamazepine (CBZ) and its active metabolite carbamazepine-10,11 epoxide (CBZE)] in a single DBS has been developed and validated. Whole blood was spotted onto Guthrie cards and dried. Using a standard punch (6 mm diameter), a circular disc was punched from the card and extracted with methanol: acetonitrile (3:1, v/v) containing hexobarbital (Internal Standard) and sonicated prior to evaporation. The extract was then dissolved in water and vortex mixed before undergoing solid phase extraction using HLB cartridges. Chromatographic separation of the AEDs was achieved using Waters XBridge™ C18 column with a gradient system. The developed method was linear over the concentration ranges studied with r ≥ 0.995 for all compounds. The lower limits of quantification (LLOQs) were 2, 1, 2, 0.5 and 1 μg/mL for LVT, LTG, PHB, CBZE and CBZ, respectively. Accuracy (%RE) and precision (%CV) values for within and between day were <20% at the LLOQs and <15% at all other concentrations tested. This method was successfully applied to the analysis of the AEDs in DBS samples taken from children with epilepsy for the assessment of their adherence to prescribed treatments.
Resumo:
Soft ionization methods for the introduction of labile biomolecules into a mass spectrometer are of fundamental importance to biomolecular analysis. Previously, electrospray ionization (ESI) and matrix assisted laser desorption-ionization (MALDI) have been the main ionization methods used. Surface acoustic wave nebulization (SAWN) is a new technique that has been demonstrated to deposit less energy into ions upon ion formation and transfer for detection than other methods for sample introduction into a mass spectrometer (MS). Here we report the optimization and use of SAWN as a nebulization technique for the introduction of samples from a low flow of liquid, and the interfacing of SAWN with liquid chromatographic separation (LC) for the analysis of a protein digest. This demonstrates that SAWN can be a viable, low-energy alternative to ESI for the LC-MS analysis of proteomic samples.
Resumo:
Université de Mons, Dissertation, 2016
Resumo:
Chemical speciation in foodstuffs is of uttermost importance since it is nowadays recognized that both toxicity and bioavailability of an element depend on the chemical form in which the element is present. Regarding arsenic, inorganic species are classified as carcinogenic while organic arsenic, such as arsenobetaine (AsB) or arsenocholine (AsC), is considered less toxic or even non-toxic. Coupling a High Performance Liquid Chromatographer (HPLC) with an Inductively Coupled Plasma Mass Spectrometer (ICP-MS) combines the power of separation of the first with the selectivity and sensitivity of the second. The present work aims at developing a method, using HPLC-ICP-MS technique, to identify and quantify the chemical species of arsenic present in two food matrices, rice and fish. Two extraction methods, ultrasound and microwave, and different settings were studied. The best method was chosen based on recovery percentages. To ensure that no interconversion of species was occurring, individual spikes of each species of arsenic were made in both matrices and recovery rates were calculated. To guaranty accurate results reference material BCR-627 TUNA FISH, containing certified values for AsB and DMA, was analyzed. Chromatographic separation was achieved using an anion exchange column, HAMILTON-PRP X-100, which allowed to separate the four arsenic species for which standards were available (AsB, dimethylarsenic (DMA), arsenite (AsIII), arsenate (AsV). The mobile phase was chosen based on scientific literature and adjusted to laboratory conditions. Different gradients were studied. As a result we verified that the arsenic species present in both matrices were not the same. While in fish 90% of the arsenic present was in the form of arsenobetaine, in rice 80% of arsenic was present as DMA and 20% as inorganic arsenic.
Resumo:
In the last decades, the effects of the air pollution have been increasing, especially in the case of the human health diseases. In order to overcome this problem, scientists have been studying the components of the air. As a part of water-soluble organic compounds, amino acids are present in the atmospheric environment as components of diverse living organisms which can be responsible for spreading diseases through the air. Liquid chromatography is one technique capable of distinguish the different amino acids from each other. In this work, aiming at separating the amino acids found in the aerosols samples collected in Aveiro, the ability of four columns (Mixed-Mode WAX-1, Mixed-Mode HILIC-1, Luna HILIC and Luna C18) to separate four amino acids (aspartic acid, lysine, glycine and tryptophan) and the way the interaction of the stationary phases of the columns with the analytes is influenced by organic solvent concentration and presence/concentration of the buffer, are being assessed. In the Mixed-Mode WAX-1 column, the chromatograms of the distinct amino acids revealed the separation was not efficient, since the retention times were very similar. In the case of lysine, in the elution with 80% (V/V) MeOH, the peaks appeared during the volume void. In the Mixed-Mode HILIC-1 column, the variation of the organic solvent concentration did not affect the elution of the four studied amino acids. Considering the Luna HILIC column, the retention times of the amino acids were too close to each other to ensure a separation among each other. Lastly, the Luna C18 column revealed to be useful to separate amino acids in a gradient mode, being the variation of the mobile phase composition in the organic solvent concentration (ACN). Luna C18 was the column used to separate the amino acids in the real samples and the mobile phase had acidified water and ACN. The gradient consisted in the following program: 0 – 2 min: 5% (V/V) ACN, 2 – 8 min: 5 – 2 % (V/V) ACN, 8 – 16 min: 2% (V/V) ACN, 16 – 20 min: 2 – 20 % (V/V) ACN, 20 – 35 min: 20 – 35 % (V/V) ACN. The aerosols samples were collected by using three passive samplers placed in two different locations in Aveiro and each sampler had two filters - one faced up and the other faced down. After the sampling, the water-soluble organic compounds was extracted by dissolution in ultra-pure water, sonication bath and filtration. The resulting filtered solutions were diluted in acidified water for the chromatographic separation. The results from liquid chromatography revealed the presence of the amino acids, although it was not possible to identify each one of them individually. The chromatograms and the fluorescence spectra showed the existence of some patterns: the samples that correspond to the up filters had more intense peaks and signals, revealing that the up filters collected more organic matter.
Resumo:
The forensic toxicologist faces challenges in the detection of drugs and poisons in biological samples due to transformations which occur both during life and after death. For example, changes can result from drug metabolism during life or from the use of formalin solution for post mortem embalming purposes. The former requires the identification of drug metabolites and the latter the identification of chemical reaction products in order to know which substances had been administered. The work described in this thesis was aimed at providing ways of tackling these challenges and was divided into two parts. Part 1 investigated the use of in vitro drug metabolism by human liver microsomes (HLM) to obtain information on drug metabolites and Part 2 investigated the chemical reactions of drugs and a carbamate pesticide with formalin solution and formalin-blood. The initial aim of part I was to develop an in vitro metabolism method using HLM, based on a literature review of previous studies of this type. MDMA was chosen as a model compound to develop the HLM method because its metabolism was known and standards of its metabolites were commercially available. In addition, a sensitive and selective method was developed for the identification and quantitation of hydrophilic phase I drug metabolites using LC/MS/MS with a conventional reverse-phase (C18) column. In order to obtain suitable retention factors for polar drug metabolites on this column, acetyl derivatives were evaluated for converting the metabolites to more lipophilic compounds and an optimal separation system was developed. Acetate derivatives were found to be stable in the HPLC mobile phase and to provide good chromatographic separation of the target analytes. In vitro metabolism of MDMA and, subsequently, of other drugs involved incubation of 4 µg drug substance in pH 7.4 buffer with an NADPH generating system (NGS) at 37oC for 90 min with addition of more NGS after 30 min. The reaction was stopped at 90 min by the addition of acetonitrile before extraction of the metabolites. Acetate derivatives of MDMA metabolites were identified by LC/MS/MS using multiple reaction monitoring (MRM). Three phase I metabolites (both major and minor metabolites) of MDMA were detected in HLM samples. 3,4-dihydroxy-methamphetamine and 4-hydroxy-3-methoxymethamphetamine were found to be major metabolites of MDMA whereas 3,4-methylenedioxyamphetamine was found to be a minor metabolite. Subsequently, ten MDMA positive urines were analysed to compare the metabolite patterns with those produced by HLM. An LC/MS method for MDMA and its metabolites in urine samples was developed and validated. The method demonstrated good linearity, accuracy and precision and insignificant matrix effects, with limits of quantitation of 0.025 µg/ml. Moreover, derivatives of MDMA and its metabolites were quantified in all 10 positive human urine samples. The urine metabolite pattern was found to be similar to that from HLM. The second aim of Part 1 was to use the HLM system to study the metabolism of some new psychoactive substances, whose misuse worldwide has necessitated the development of analytical methods for these drugs in biological specimens. Methylone and butylone were selected as representative cathinones and para-methoxyamphetamine (PMA) was chosen as a representative ring-substituted amphetamine, because of the involvement of these drugs in recent drug-related deaths, because of a relative lack of information on their metabolism, and because reference standards of their metabolites were not commercially available. An LC/MS/MS method for the analysis of methylone, butylone, PMA and their metabolites was developed. Three phase I metabolites of methylone and butylone were detected in HLM samples. Ketone reduction to β-OH metabolites and demethylenation to dihydroxy-metabolites were found to be major phase I metabolic pathways of butylone and methylone whereas N-demethylation to nor-methylone and nor-butylone were found to be minor pathways. Also, demethylation to para-hydroxyamphetamine was found to be a major phase I metabolic pathway of PMA whereas β-hydroxylation to β-OH-PMA was found to be a minor pathway. Formaldehyde is used for embalming, to reduce decomposition and preserve cadavers, especially in tropical countries such as Thailand. Drugs present in the body can be exposed to formaldehyde resulting in decreasing concentrations of the original compounds and production of new substances. The aim of part II of the study was to evaluate the in vitro reactions of formaldehyde with selected drug groups including amphetamines (amphetamine, methamphetamine and MDMA), benzodiazepines (alprazolam and diazepam), opiates (morphine, hydromorphone, codeine and hydrocodone) and with a carbamate insecticide (carbosulfan). The study would identify degradation products to serve as markers for the parent compounds when these were no longer detectable. Drugs standards were spiked in 10% formalin solution and 10% formalin blood. Water and whole blood without formalin were used for controls. Samples were analysed by LC/MS/MS at different times from the start, over periods of up to 30 days. Amphetamine, methamphetamine and MDMA were found to rapidly convert to methamphetamine, DMA and MDDMA respectively, in both formalin solution and formalin blood, confirming the Eschweiler-Clarke reaction between amine-containing compounds and formaldehyde. Alprazolam was found to be unstable whereas diazepam was found to be stable in both formalin solution and water. Both were found to hydrolyse in formalin solution and to give open-ring alprazolam and open-ring diazepam. Other alprazolam conversion products attached to paraformaldehyde were detected in both formalin solution and formalin blood. Morphine and codeine were found to be more stable than hydromorphone and hydrocodone in formalin solution. Conversion products of hydromorphone and hydrocodone attached to paraformaldehyde were tentatively identified in formalin solution. Moreover, hydrocodone and hydromorphone rapidly decreased within 24 h in formalin blood and could not be detected after 7 days. Carbosulfan was found to be unstable in formalin solution and was rapidly hydrolysed within 24 h, whereas in water it was stable up to 48 h. Carbofuran was the major degradation product, plus smaller amounts of other products, 3-ketocarbofuran and 3-hydrocarbofuran. By contrast, carbosulfan slowly hydrolysed in formalin-blood and was still detected after 15 days. It was concluded that HLM provide a useful tool for human drug metabolism studies when ethical considerations preclude their controlled administration to humans. The use of chemical derivatisation for hydrophilic compounds such as polar drug metabolites for analysis by LC/MS/MS with a conventional C18 column is effective and inexpensive, and suitable for routine use in the identification and quantitation of drugs and their metabolites. The detection of parent drugs and their metabolites or conversion and decomposition products is potentially very useful for the interpretation of cases in forensic toxicology, especially when the original compounds cannot be observed.
Resumo:
Neste trabalho é proposto pela primeira vez, o desenvolvimento e validação de um método analítico baseado no emprego da dispersão da matriz em fase sólida (MSPD) modificada, para extração das espécies CH3Hg+ e Hg2+ em amostras de peixe e determinação por cromatografia em fase gasosa acoplada à espectrometria de massas (GC-MS). O método de extração utilizando a MSPD combina o rompimento da estrutura física da amostra, através da maceração e do uso de SiO2 como suporte sólido, com o método da extração ácida, utilizando uma solução de HCl 4,2 mol L-1 e NaCl 0,5 mol L-1. Para otimização da MSPD, foram avaliados parâmetros como massa de amostra, massa de suporte sólido, concentração de HCl, concentração de NaCl, tipo de suporte sólido e o tempo de agitação, com auxílio da metodologia de superfície de resposta. Além disso, a etapa de derivatização e a separação cromatográfica também foram otimizadas na determinação de CH3Hg+ e Hg2+ por GC-MS. O método mostrouse adequado para extração e determinação de espécies de mercúrio através da aplicação em materiais de referência certificados de fígado de peixe (DOLT-3) e músculo de peixe (DORM-2), apresentando boas concordâncias com os valores certificados e desvio padrão relativo inferior a 9,5%. Os limites de detecção foram de 0,06 e 0,12 µg g-1 para CH3Hg+ e Hg2+, respectivamente. Além disso, foi observado um significativo efeito de matriz e, por isso, a calibração foi feita com curvas preparadas com o extrato da MSPD. O método mostrou boa concordância na comparação entre a soma da concentração das espécies e a concentração de mercúrio total determinada por espectrometria de massas com plasma indutivamente acoplado com geração de vapor frio (CVG-ICP-MS), após digestão assistida por micro-ondas (MAD) em peixes do tipo atum (Thunnus thynnus), cação anjo (Squatina squatina) e cação viola (Rhinobatos blochii.).
Resumo:
O Rio Grande Sul destaca-se no cenário nacional como grande produtor de diversas culturas, as quais demandam grande quantidade de agrotóxicos das mais diversas classes químicas e toxicidades. No entanto a intensa utilização destes compostos torna-se uma preocupação devido a possíveis contaminações das águas superficiais e subterrâneas. Em virtude da degradação dos mananciais a água mineral passou a ser uma das fontes mais utilizadas para o consumo humano, pois tem-se a percepção de que a mesma possui melhor qualidade que a água tratada, além disso acredita-se que a mesma esta isenta de substâncias orgânicas prejudiciais à saúde humana. Neste trabalho, foi realizada a determinação dos agrotóxicos atrazina, simazina, imazapique, imazetapir, imidacloprido, ciproconazol, tebuconazol e epoxiconazol em água mineral empregando a Microextração Líquido-Líquido Dispersiva (DLLME), Microextração Líquido-Líquido Dispersiva com Solidificação da Gota Orgânica Flutuante (DLLME-SFO) e Cromatografia Líquida acoplada à Espectrometria de Massas em série com fonte de ionização por Eletronebulização (LC-ESI-MS/MS). Para o método empregando DLLME e LC-ESI-MS/MS foram otimizados alguns fatores como o tipo e volume de solvente extrator e dispersor e pH. Após a otimização dos parâmetros de extração, fragmentação dos compostos e separação cromatográfica, o método foi validado avaliando-se curva analítica, linearidade, limites de detecção e quantificação, precisão (repetitividade e precisão intermediária) e exatidão (recuperação). Todas as curvas analíticas apresentaram valores de r maiores que 0,999. Os Limites de Quantificação (LOQs) para o método estiveram na faixa de 5 a 500 ng L-1. Foram obtidas recuperações entre 102 - 120% para a repetibilidade e entre 92 e 110% para a precisão intermediária, com RSD de 2 a 10% para todos os compostos. Para o método empregando DLLME-SFO e LC-ESI-MS/MS foram avaliados alguns parâmetros que afetam a eficiência da extração como, tipo e volume de solvente extrator e dispersor, força iônica e pH. Nas condições ótimas de extração todas as curvas analíticas apresentaram valores de r maiores que 0,997. Os LOQs para o método variaram entre 12,5 - 125 ng L-1. As recuperações foram entre 70 e 118% para a repetitividade e entre 76 e 95% para a precisão intermediária, com RSD de 2 a 18% para todos os compostos. Com relação ao Efeito Matriz (EM) avaliado para todos os compostos pelos dois métodos, foi observado baixo EM. Isso indicou que não é necessário utilizar a curva analítica preparada no extrato branco da matriz para a quantificação destes analitos. Ambos os métodos foram aplicados para a determinação de resíduos de agrotóxicos em amostras de água mineral provenientes de diferentes regiões do estado do Rio Grande do Sul e não foram encontrados resíduos de agrotóxicos nas amostras analisadas. Os métodos validados apresentaram como principais vantagens baixo consumo de solventes orgânicos e amostra, rapidez, altos fatores de concentração e recuperações dentro da faixa aceitável. Os limites de quantificação dos métodos ficaram abaixo dos limites máximos de resíduos permitidos pela legislação brasileira para agrotóxicos em água mineral.
Resumo:
Context: Species of Baccharis exhibit antibiotic, antiseptic, and wound-healing properties, and have been used in the traditional medicine of South America for the treatment of inflammation, headaches, diabetes, and hepatobiliary disorders.Objective: To investigate the anti-inflammatory activity of organic phases from EtOH extract of the aerial parts of Baccharis uncinella DC (Asteraceae).Materials and methods: The crude EtOH extract from the aerial parts of B. uncinella was subjected to partition procedures and the corresponding CH(2)Cl(2) and EtOAc phases were subjected to several chromatographic separation procedures. Thus, these phases and their purified compounds were assayed for evaluation of anti-inflammatory activity.Results: The CH(2)Cl(2) phase from EtOH extract from B. uncinella contained two triterpenoids (oleanolic and ursolic acids) and one flavonoid (pectolinaringenin), whereas the respective EtOAc phase showed to be composed mainly by two phenylpropanoid derivatives (caffeic and ferulic acids). The CH(2)Cl(2) and EtOAc phases as well as their isolated compounds exhibited anti-inflammatory effects against inflammatory reactions induced by phospholipase A2 (from Crotalus durissus terrificus venom) and by carrageenan.Discussion and conclusion: The results suggested that the components obtained from partition phases of EtOH extract of B. uncinella could represent lead molecules for the development of anti-inflammatory agents. Additionally, the results confirmed the use of Baccharis genus in the traditional medicine of South America for the treatment of inflammation and other heath disorders. To date, the present work describes for the first time the anti-inflammatory effects of compounds isolated from B. uncinella.
Resumo:
O atenolol é um fármaco β-bloqueador normalmente encontrado em águas residuais devido à incapacidade que os processos convencionais de tratamento destas águas têm em removê-lo. Neste trabalho foram utilizados microcosmos de leitos construídos de macrófitas de fluxo sub-superficial utilizando uma matriz de argila expandida (LECA) e plantados com Phragmites australis para avaliar a sua capacidade em remover atenolol das águas residuais. Para a detecção e quantificação do atenolol em soluções aquosas (águas e efluentes) desenvolveu-se e optimizou-se uma metodologia analítica usando separação cromatográfica por HPLC e detecção espectrofotométrica por diode array (HPLC-DAD) ou por ultravioleta visível (HPLC-UV-Vis). Desenvolveu-se também um procedimento de limpeza e concentração de amostra por extracção em fase sólida (SPE), o qual foi utilizado sempre que as concentrações do analito se encontraram abaixo dos limites de quantificação do equipamento. A utilização desta metodologia de HPLC, combinada com uma eficaz pré-concentração por SPE, resultou num método analítico com um limite de quantificação muito reduzido (9 ngmL-1) e elevada reprodutibilidade (RSD<4%). A eficiência de remoção de atenolol pelos sistemas de macrófitas estudados foi de 93% após um tempo de retenção de 4 dias. Foram testados leitos só com LECA e com LECA e plantas para remoção do atenolol. Nos leitos só com LECA, a cinética de remoção foi caracterizada por um rápido passo inicial (uma remoção de aproximadamente 75% após apenas 24 h), o qual é frequentemente atribuído à adsorção na matriz de LECA. A remoção de atenolol nos leitos de LECA continuou a aumentar de forma constante até ao final do ensaio (8 dias), sendo, contudo cerca de 5-10% mais baixo do que o valor observado nos leitos das plantas após os 4 primeiros dias. Para o tempo de retenção de 4 dias a maioria do atenolol é removido pela matriz de LECA, porém um acréscimo de cerca de 12-14% relativamente à eficiência de remoção global pode ser atribuído às plantas (Phragmites australis), o que está de acordo com trabalhos anteriormente publicados. Apesar de ser necessário realizar mais testes utilizando sistemas em larga escala, de modo a conseguir avaliar totalmente o comportamento do atenolol num sistema de leitos construídos de macrófitas, o presente estudo apresenta a possibilidade de aplicar este tipo de sistemas, relativamente baratos, no tratamento de águas residuais contaminadas com atenolol. ABSTRACT: Atenolol is a β-blocker drug commonly found in wastewaters due to the inability of the conventional wastewater treatment processes to remove it. ln this study, subsurface flow constructed wetland microscosm systems have been established with a matrix of light expanded clay aggregates (LECA) and planted with Phragmites australis in order to evaluate their ability to remove atenolol from wastewater. For the detection and quantification of atenolol in aqueous solutions (water and wastewater), an adequate analytical methodology was developed and optimized using chromatographic separation by HPLC and diode array (DAD) or UV-Vis spectrophotometric detection. A sample clean-up and preconcentration procedure by solid phase extraction (SPE) was also developed for use whenever the concentration levels of the analyte were below the instrument's limit of quantification. Combined with an efficient SPE concentration step, the use of HPLC yielded an analytical method for atenolol quantification with very low LOQ (9 ngmL-1) and high reproducibility (RSD< 4%). Overall atenolol removal efficiency of 93% was achieved after a retention time of only 4 days with the microcosm systems planted with Phragmites australis. The removal kinetics was characterized by an initial fast step (removal of about 75% after just 24h) which is mainly attributable to adsorption on the LECA matrix. Atenolol removal in LECA beds continues to increase in a steady pace up to the end of the assay (8 days) being nevertheless about 5-l 0% lower than those observed in the planted beds after the first 4 days. For the retention time of 4 days most of the atenolol is removed by the LECA matrix but an additional 12-14% to the overall removal efficiency can be attributed to the Phragmites plants, which comes in agreement with other published reports. Despite the fact that further tests using larger scale systems are required to fully evaluate the atenolol behavior in a constructed wetland system, this study points out to the possible application of these low-cost wastewater systems to treat atenolol contaminated wastewater.
Resumo:
A ocorrência e destino de fármacos no ambiente aquático tem vindo a ser reconhecido como um problema emergente em química ambiental. Alguns compostos são resistentes à degradação nas estações de tratamento de águas residuais, ETARs, enquanto que outros, ainda que sofram degradação parcial, continuam a ser lançados nos meios aquáticos em quantidades apreciáveis. O Ibuprofeno, IB, um dos anti inflamatórios mais consumidos por todo o mundo, é um dos fármacos mais detectados no meio hídrico. Apesar dos sistemas de tratamento convencionais utilizados nas ETARs removerem até 90% do IB das águas residuais, é frequente o efluente descarregado conter ainda quantidades significativas deste poluente. A presença destes compostos no ambiente deve ser avaliada dado que possuem actividade biológica, mesmo a baixas concentrações. Os processos avançados de oxidação com peróxido de hidrogénio, na presença de catalisadores heterogéneos, permitem melhorar significativamente a remoção deste tipo de compostos em águas. Assim, foi objectivo deste trabalho o estudo da utilização de peróxido de hidrogénio como agente oxidante na remoção de IB em soluções aquosas, na presença de complexo de acetilacetonato de Ni (II) disperso em PDMS ou encapsulado em zeólitos NaY. Para o doseamento do fármaco em solução foi necessário desenvolver um método analítico consistindo de separação cromatográfica por HPLC e detecção e quantificação por UV-Vis. Não houve necessidade de recorrer a um passo de pré concentração de amostras por extracção em fase sólida (SPE) devido ao facto das concentrações de IB medidas ao longo do trabalho se terem sempre encontrado acima do LOQ (811 g L-1) do método analítico por injecção directa. Deste estudo pode concluir-se que o catalisador que apresentou melhor actividade catalítica e consequentemente maior remoção do IB em solução, foi o complexo de acetilacetonato de Ni (II), disperso em PDMS. Foi avaliada a influência, na conversão do IB, de diferentes parâmetros como a concentração inicial de peróxido de hidrogénio adicionada, quantidade de catalisador utilizada na mistura reaccional e temperatura. Os resultados permitiram concluir que os aumentos destes parâmetros conduzem a um aumento da actividade catalítica da reacção. A estabilidade catalítica do acetilacetonato de Ni (II)/PDMS, foi avaliada em ensaios consecutivos com a mesma amostra e nas mesmas condições, tendo-se observado que, após 8 utilizações, o catalisador perde ligeiramente a actividade (cerca de 11% do seu valor inicial). ABSTRACT: The presence and fate of pharmaceuticals in the aquatic environment is an emergent issue in environmental chemistry. Some compounds are poorly removed in wastewater treatment plants (WWTPs) while others, in spite of being partially removed, are still present in the WWTPs effluents and discharged in the receiving water bodies. Ibuprofen, IB, a non-steroid anti-inflammatory drug, is one of the most used and also one of the most frequently detected pharmaceutical contaminants in aquifers worldwide. Its removal by conventional wastewater treatment processes used in most WWTPs is usually high (up to 90% of incoming IB may be removed), but duet the high loads present in the influents, still significant amounts of IB usually leave the WWTPs in the treated effluents. The presence of these compounds in the environment must be evaluated considering that they may have some biological activity even at low concentrations. Advanced oxidation processes using hydrogen peroxide, in the presence of heterogeneous catalysts, provide a significantly improved removal of this type of substances from waters. Therefore, it was the aim of this work to study the use of hydrogen peroxide as an oxidizing agent in the removal of IB from aqueous solutions, in the presence of the catalyst nickel (II) acetylacetonate dispersed in PDMS or encapsulated in the NaY zeolite. For the quantification of the pharmaceutical in aqueous solution it was necessary to develop an analytical methodology based in chromatographic separation by HPLC and with UV-Vis detection and quantification. There was no need for a preconcentration step of the samples by solid phase extraction (SPE) as the IB concentrations measured were always above the limit of quantification (811 bL1 of) the analytical method. The results from this study have shown that the catalyst which presented the best catalytic activity and the highest IB removal in solution was nickel (II) acetylacetonate dispersed in PDMS.