983 resultados para Z-Source
Resumo:
This paper presents the possibility of utilizing a current source topology instead of a voltage source as an efficient, flexible and reliable power supply for plasma applications. A buck-boost converter with a current controller has been used to transfer energy from an inductor to a plasma system. A control strategy has also been designed to satisfy all the desired purposes. The main concept behind this topology is to provide high dv/dt regardless of the switching speed of a power switch and to control the current level to properly transfer adequate energy to various plasma applications.
Resumo:
Problem-based learning (PBL) is a pedagogical methodology that presents the learner with a problem to be solved to stimulate and situate learning. This paper presents key characteristics of a problem-based learning environment that determines its suitability as a data source for workrelated research studies. To date, little has been written about the availability and validity of PBL environments as a data source and its suitability for work-related research. We describe problembased learning and use a research project case study to illustrate the challenges associated with industry work samples. We then describe the PBL course used in our research case study and use this example to illustrate the key attributes of problem-based learning environments and show how the chosen PBL environment met the work-related research requirements of the research case study. We propose that the more realistic the PBL work context and work group composition, the better the PBL environment as a data source for a work-related research. The work context is more realistic when relevant and complex project-based problems are tackled in industry-like work conditions over longer time frames. Work group composition is more realistic when participants with industry-level education and experience enact specialized roles in different disciplines within a professional community.
Resumo:
Since the emergence of the destination branding literature in 1998, there have been few studies related to performance measurement of destination brand campaigns. There has also been little interest to date in researching the extent to which a destination brand represents the host community’s sense of place. Given that local residents represent a key stakeholder group for the destination marketing organisation (DMO), research is required to examine the extent to which marketing communications have been effective in enhancing engagement with the brand, and inducing a brand image that is congruent with the brand identity. Motivated by conceptual and practical aims, this paper reports the trial of a hierarchy of consumer-based brand equity (CBBE) for a destination, from the perspective of residents as active participants of local tourism. It is proposed that strong levels of CBBE among the host community representsa strong level of CBBE among the host community represents a source of comparative advantage for a destination, for which the DMO could proactively develop into a competitive advantage.
Resumo:
Various load compensation schemes proposed in literature assume that voltage source at point of common coupling (PCC) is stiff. In practice, however, the load is remote from a distribution substation and is supplied by a feeder. In the presence of feeder impedance, the PWM inverter switchings distort both the PCC voltage and the source currents. In this paper load compensation with such a non-stiff source is considered. A switching control of the voltage source inverter (VSI) based on state feedback is used for load compensation with non-stiff source. The design of the state feedback controller requires careful considerations in choosing a gain matrix and in the generation of reference quantities. These aspects are considered in this paper. Detailed simulation and experimental results are given to support the control design.
Identification of acoustic emission wave modes for accurate source location in plate-like structures
Resumo:
Acoustic emission (AE) technique is a popular tool used for structural health monitoring of civil, mechanical and aerospace structures. It is a non-destructive method based on rapid release of energy within a material by crack initiation or growth in the form of stress waves. Recording of these waves by means of sensors and subsequent analysis of the recorded signals convey information about the nature of the source. Ability to locate the source of stress waves is an important advantage of AE technique; but as AE waves travel in various modes and may undergo mode conversions, understanding of the modes (‘modal analysis’) is often necessary in order to determine source location accurately. This paper presents results of experiments aimed at finding locations of artificial AE sources on a thin plate and identifying wave modes in the recorded signal waveforms. Different source locating techniques will be investigated and importance of wave mode identification will be explored.
Resumo:
In this study, the host-specificity and -sensitivity of human- and bovine-specific adenoviruses (HS-AVs and BS-AVs) were evaluated by testing wastewater/fecal samples from various animal species in Southeast, Queensland, Australia. The overall specificity and sensitivity of the HS-AVs marker were 1.0 and 0.78, respectively. These figures for the BS-AVs were 1.0 and 0.73, respectively. Twenty environmental water samples were colleted during wet conditions and 20 samples were colleted during dry conditions from the Maroochy Coastal River and tested for the presence of fecal indicator bacteria (FIB), host-specific viral markers, zoonotic bacterial and protozoan pathogens using PCR/qPCR. The concentrations of FIB in water samples collected after wet conditions were generally higher compared to dry conditions. HS-AVs was detected in 20% water samples colleted during wet conditions and whereas BS-AVs was detected in both wet (i.e., 10%) and dry (i.e., 10%) conditions. Both, C. jejuni mapA and Salmonella invA genes were detected in 10% and 10% of samples, respectively collected during dry conditions. The concentrations of Salmonella invA ranged between 3.5 × 102 to 4.3 × 102 genomic copies per 500 ml of water G. lamblia β-giardin gene was detected only in one sample (5%) collected during the dry conditions. Weak or significant correlations were observed between FIB with viral markers and zoonotic pathogens. However, during dry conditions, no significant correlations were observed between FIB concentrations with viral markers and zoonotic pathogens. The prevalence of HS-AVs in samples collected from the study river suggests that the quality of water is affected by human fecal pollution and as well as bovine fecal pollution. The results suggest that HS-AVs and BS-AVs detection using PCR could be a useful tool for the identification of human sourced fecal pollution in coastal waters.
Resumo:
Fractional Fokker-Planck equations (FFPEs) have gained much interest recently for describing transport dynamics in complex systems that are governed by anomalous diffusion and nonexponential relaxation patterns. However, effective numerical methods and analytic techniques for the FFPE are still in their embryonic state. In this paper, we consider a class of time-space fractional Fokker-Planck equations with a nonlinear source term (TSFFPE-NST), which involve the Caputo time fractional derivative (CTFD) of order α ∈ (0, 1) and the symmetric Riesz space fractional derivative (RSFD) of order μ ∈ (1, 2). Approximating the CTFD and RSFD using the L1-algorithm and shifted Grunwald method, respectively, a computationally effective numerical method is presented to solve the TSFFPE-NST. The stability and convergence of the proposed numerical method are investigated. Finally, numerical experiments are carried out to support the theoretical claims.
Resumo:
Executive summary Objective: The aims of this study were to identify the impact of Pandemic (H1N1) 2009 Influenza on Australian Emergency Departments (EDs) and their staff, and to inform planning, preparedness, and response management arrangements for future pandemics, as well as managing infectious patients presenting to EDs in everyday practice. Methods This study involved three elements: 1. The first element of the study was an examination of published material including published statistics. Standard literature research methods were used to identify relevant published articles. In addition, data about ED demand was obtained from Australian Government Department of Health and Ageing (DoHA) publications, with several state health departments providing more detailed data. 2. The second element of the study was a survey of Directors of Emergency Medicine identified with the assistance of the Australasian College for Emergency Medicine (ACEM). This survey retrieved data about demand for ED services and elicited qualitative comments on the impact of the pandemic on ED management. 3. The third element of the study was a survey of ED staff. A questionnaire was emailed to members of three professional colleges—the ACEM; the Australian College of Emergency Nursing (ACEN); and the College of Emergency Nursing Australasia (CENA). The overall response rate for the survey was 18.4%, with 618 usable responses from 3355 distributed questionnaires. Topics covered by the survey included ED conditions during the (H1N1) 2009 influenza pandemic; information received about Pandemic (H1N1) 2009 Influenza; pandemic plans; the impact of the pandemic on ED staff with respect to stress; illness prevention measures; support received from others in work role; staff and others’ illness during the pandemic; other factors causing ED staff to miss work during the pandemic; and vaccination against Pandemic (H1N1) 2009 Influenza. Both qualitative and quantitative data were collected and analysed. Results: The results obtained from Directors of Emergency Medicine quantifying the impact of the pandemic were too limited for interpretation. Data sourced from health departments and published sources demonstrated an increase in influenza-like illness (ILI) presentations of between one and a half and three times the normal level of presentations of ILIs. Directors of Emergency Medicine reported a reasonable level of preparation for the pandemic, with most reporting the use of pandemic plans that translated into relatively effective operational infection control responses. Directors reported a highly significant impact on EDs and their staff from the pandemic. Growth in demand and related ED congestion were highly significant factors causing distress within the departments. Most (64%) respondents established a ‘flu clinic’ either as part of Pandemic (H1N1) 2009 Influenza Outbreak in Australia: Impact on Emergency Departments. the ED operations or external to it. They did not note a significantly higher rate of sick leave than usual. Responses relating to the impact on staff were proportional to the size of the colleges. Most respondents felt strongly that Pandemic (H1N1) 2009 Influenza had a significant impact on demand in their ED, with most patients having low levels of clinical urgency. Most respondents felt that the pandemic had a negative impact on the care of other patients, and 94% revealed some increase in stress due to lack of space for patients, increased demand, and filling staff deficits. Levels of concern about themselves or their family members contracting the illness were less significant than expected. Nurses displayed significantly higher levels of stress overall, particularly in relation to skill-mix requirements, lack of supplies and equipment, and patient and patients’ family aggression. More than one-third of respondents became ill with an ILI. Whilst respondents themselves reported taking low levels of sick leave, respondents cited difficulties with replacing absent staff. Ranked from highest to lowest, respondents gained useful support from ED colleagues, ED administration, their hospital occupational health department, hospital administration, professional colleges, state health department, and their unions. Respondents were generally positive about the information they received overall; however, the volume of information was considered excessive and sometimes inconsistent. The media was criticised as scaremongering and sensationalist and as being the cause of many unnecessary presentations to EDs. Of concern to the investigators was that a large proportion (43%) of respondents did not know whether a pandemic plan existed for their department or hospital. A small number of staff reported being redeployed from their usual workplace for personal risk factors or operational reasons. As at the time of survey (29 October –18 December 2009), 26% of ED staff reported being vaccinated against Pandemic (H1N1) 2009 Influenza. Of those not vaccinated, half indicated they would ‘definitely’ or ‘probably’ not get vaccinated, with the main reasons being the vaccine was ‘rushed into production’, ‘not properly tested’, ‘came out too late’, or not needed due to prior infection or exposure, or due to the mildness of the disease. Conclusion: Pandemic (H1N1) 2009 Influenza had a significant impact on Australian Emergency Departments. The pandemic exposed problems in existing plans, particularly a lack of guidelines, general information overload, and confusion due to the lack of a single authoritative information source. Of concern was the high proportion of respondents who did not know if their hospital or department had a pandemic plan. Nationally, the pandemic communication strategy needs a detailed review, with more engagement with media networks to encourage responsible and consistent reporting. Also of concern was the low level of immunisation, and the low level of intention to accept vaccination. This is a problem seen in many previous studies relating to seasonal influenza and health care workers. The design of EDs needs to be addressed to better manage infectious patients. Significant workforce issues were confronted in this pandemic, including maintaining appropriate staffing levels; staff exposure to illness; access to, and appropriate use of, personal protective equipment (PPE); and the difficulties associated with working in PPE for prolonged periods. An administrative issue of note was the reporting requirement, which created considerable additional stress for staff within EDs. Peer and local support strategies helped ensure staff felt their needs were provided for, creating resilience, dependability, and stability in the ED workforce. Policies regarding the establishment of flu clinics need to be reviewed. The ability to create surge capacity within EDs by considering staffing, equipment, physical space, and stores is of primary importance for future pandemics.
Resumo:
A composite line source emission (CLSE) model was developed to specifically quantify exposure levels and describe the spatial variability of vehicle emissions in traffic interrupted microenvironments. This model took into account the complexity of vehicle movements in the queue, as well as different emission rates relevant to various driving conditions (cruise, decelerate, idle and accelerate), and it utilised multi-representative segments to capture the accurate emission distribution for real vehicle flow. Hence, this model was able to quickly quantify the time spent in each segment within the considered zone, as well as the composition and position of the requisite segments based on the vehicle fleet information, which not only helped to quantify the enhanced emissions at critical locations, but it also helped to define the emission source distribution of the disrupted steady flow for further dispersion modelling. The model then was applied to estimate particle number emissions at a bi-directional bus station used by diesel and compressed natural gas fuelled buses. It was found that the acceleration distance was of critical importance when estimating particle number emission, since the highest emissions occurred in sections where most of the buses were accelerating and no significant increases were observed at locations where they idled. It was also shown that emissions at the front end of the platform were 43 times greater than at the rear of the platform. Although the CLSE model is intended to be applied in traffic management and transport analysis systems for the evaluation of exposure, as well as the simulation of vehicle emissions in traffic interrupted microenvironments, the bus station model can also be used for the input of initial source definitions in future dispersion models.
Resumo:
Managing the sustainability of urban infrastructure requires regular health monitoring of key infrastructure such as bridges. The process of structural health monitoring involves monitoring a structure over a period of time using appropriate sensors, extracting damage sensitive features from the measurements made by the sensors, and analysing these features to determine the current state of the structure. Various techniques are available for structural health monitoring of structures, and acoustic emission is one technique that is finding an increasing use in the monitoring of civil infrastructures such as bridges. Acoustic emission technique is based on the recording of stress waves generated by rapid release of energy inside a material, followed by analysis of recorded signals to locate and identify the source of emission and assess its severity. This chapter first provides a brief background of the acoustic emission technique and the process of source localization. Results from laboratory experiments conducted to explore several aspects of the source localization process are also presented. The findings from the study can be expected to enhance knowledge of the acoustic emission process, and to aid the development of effective bridge structure diagnostics systems.
Resumo:
In this paper, two different high bandwidth converter control strategies are discussed. One of the strategies is for voltage control and the other is for current control. The converter, in each of the cases, is equipped with an output passive filter. For the voltage controller, the converter is equipped with an LC filter, while an output has an LCL filter for current controller. The important aspect that has been discussed the paper is to avoid computation of unnecessary references using high-pass filters in the feedback loop. The stability of the overall system, including the high-pass filters, has been analyzed. The choice of filter parameters is crucial for achieving desirable system performance. In this paper, the bandwidth of achievable performance is presented through frequency (Bode) plot of the system gains. It has been illustrated that the proposed controllers are capable of tracking fundamental frequency components along with low-order harmonic components. Extensive simulation results are presented to validate the control concepts presented in the paper.