940 resultados para XFEL Ondulatori CXDI Spettroscopia Ultraveloce Femtosecondo Laser X-Ray Sincrotrone
Resumo:
Pericardial cysts are rare benign congenital malformations, usually small, asymptomatic and detected incidentally on chest X-ray as a mass located in the right costophrenic angle. Giant pericardial cysts are very uncommon and produce symptoms by compressing adjacent structures. In this report, the authors present a case of a symptomatic giant pericardial cyst incorrectly diagnosed as dextrocardia on chest X-ray.
Resumo:
Ligand K-edge XAS of an [Fe3S4]0 model complex is reported. The pre-edge can be resolved into contributions from the í2Ssulfide, í3Ssulfide, and Sthiolate ligands. The average ligand-metal bond covalencies obtained from these pre-edges are further distributed between Fe3+ and Fe2.5+ components using DFT calculations. The bridging ligand covalency in the [Fe2S2]+ subsite of the [Fe3S4]0 cluster is found to be significantly lower than its value in a reduced [Fe2S2] cluster (38% vs 61%, respectively). This lowered bridging ligand covalency reduces the superexchange coupling parameter J relative to its value in a reduced [Fe2S2]+ site (-146 cm-1 vs -360 cm-1, respectively). This decrease in J, along with estimates of the double exchange parameter B and vibronic coupling parameter ì2/k-, leads to an S ) 2 delocalized ground state in the [Fe3S4]0 cluster. The S K-edge XAS of the protein ferredoxin II (Fd II) from the D. gigas active site shows a decrease in covalency compared to the model complex, in the same oxidation state, which correlates with the number of H-bonding interactions to specific sulfur ligands present in the active site. The changes in ligand-metal bond covalencies upon redox compared with DFT calculations indicate that the redox reaction involves a two-electron change (one-electron ionization plus a spin change of a second electron) with significant electronic relaxation. The presence of the redox inactive Fe3+ center is found to decrease the barrier of the redox process in the [Fe3S4] cluster due to its strong antiferromagnetic coupling with the redox active Fe2S2 subsite.
Correlating EPR and X-ray structural analysis of arsenite-inhibited forms of aldehyde oxidoreductase
Resumo:
J Biol Inorg Chem (2007) 12:353–366 DOI 10.1007/s00775-006-0191-9
Resumo:
J. Am. Chem. Soc., 2004, 126 (28), pp 8614–8615 DOI: 10.1021/ja0490222
Resumo:
Dissertação para obtenção do Grau de Doutor em Bioquímica, Especialidade Bioquímica Estrutural
Resumo:
Dissertação para obtenção do Grau de Doutor em Bioquímica – Ramo Bioquímica Estrutural
Resumo:
A thesis submitted for the degree of Ph. D. in Physics
Resumo:
Scanning electron microscopy applied to the mycelial phase of Sporothrix schenckii shows a matted mycelium with conidia of a regular pattern. X-Ray microanalysis applied in energy dispersive spectroscopy and also in wavelength dispersive spectroscopy reveals the presence of several elements of Mendeleef's classification.
Resumo:
A radiological study of the small intestine of 17 untreated patients in the acute phase ofschistosomiasis was performed. Twelve patients (70% of total) had alterations: nine had clear-cut thickening of the duodenal and jejunal folds, one flocculation, one fragmentation and one thickening of mucosae, flocculation and fragmentation of the barium column. There was no correlation of the gastrointestinal symptomatology (vomiting, diarrhoea, dysentery, hepatomegaly) neither with the parasitological load nor with the x-ray alterations.
Resumo:
Polymer based scintillator composites have been fabricated by combining poly(vinylidene fluoride) (PVDF) and Gd2O3:Eu nanoparticles (50nm). PVDF has been used since it is a flexible and stable binder matrix and highly resistance to thermal and light deterioration. Gd2O3:Eu has been selected as scintillator material due to its wide band gap, high density and suitable visible light yield. The structural, mechanical, thermal and electrical characteristics of the composites were studied as a function of filler content, together with their performance as scintillator material. The introduction of Gd2O3:Eu nanoparticles into the PVDF matrix does not influence the morphology of the polymer or the degree of crystallinity. On the other hand, an increase of the Young´s modulus with respect to PVDF matrix is observed for filler contents of 0.1-0.75 wt.%. The introduction of Gd2O3:Eu into the PVDF matrix increases dielectric constant and DC electrical conductivity as well as the visible light yield in the nanocomposite, being this increase dependent upon Gd2O3:Eu content and X-ray input power. In this way, Gd2O3:Eu/PVDF composites shows suitable characteristics to be used as X-ray radiation transducers, in particular for large area applications.
Resumo:
La idea principal del proyecto abarca el estudio de parámetros y fenómenos físicos. Los avances logrados se aplicarán al desarrollo de software y metodologías para cuantificación de materiales mediante microanálisis con sonda de electrones y microscopía electrónica de barrido. El microanálisis no es una técnica absoluta, sino que requiere de estándares de referencia, para obviar el uso de ciertos parámetros geométricos y atómicos difíciles de conocer con una precisión adecuada. Para contar con un método sin estándares debe abordarse la determinación de parámetros atómicos e instrumentales, que es uno de los aspectos que se desea encarar en este proyecto. Por otro lado, también se pretende incluir los parámetros estudiados en un software de cuantificación desarrollado por integrantes del proyecto. Otro de los propósitos del plan de trabajo es estudiar la potencialidad de la resolución espacial de una microsonda de electrones con el fin de desarrollar una metodología para caracterizar interfases, bordes de granos e inclusiones, con resolución submicrométrica, ya que los métodos tradicionales de cuantificación se restringen al caso de muestras planas y homogéneas dentro del volumen de interacción, pero la caracterización de inhomogeneidades a nivel micrométrico no ha sido desarrollada todavía, salvo algunas excepciones. The main idea of this project involves the study of physical parameters and phenomena. The concretion of the different goals will permit the elaboration of softeare and methodologies for materials characterization by means of electron probe microanalysis and scanning microscopy. Electron probe microanalysis is not an absolute technique, but requires reference standards in order not to involve certain geometrical and atomic parameters for which high uncertainties cannot be avoided. In order to have standardless method, the determination of atomic and instrumental parameters must be accomplished, as will be faced through this project. Complementary, the parameters studied will be included in a quantification software developed in our research group of FaMAF. Another objective of this activity plan is to study the spatial resolution potentiality of a focalized electron beam, with the aim of characterizing interphases, grain boundaries and inclusions with submicron sensitivity, since the traditional quantification procedures are restricted to flat homogeneous samples, whereas the characterization of inhomogeneities has not been developed yet.
Resumo:
Magdeburg, Univ., Fak. für Maschinenbau, Diss., 2015
Resumo:
The trabecular bone score (TBS, Med-Imaps, Pessac, France) is an index of bone microarchitecture texture extracted from anteroposterior dual-energy X-ray absorptiometry images of the spine. Previous studies have documented the ability of TBS of the spine to differentiate between women with and without fractures among age- and areal bone mineral density (aBMD)-matched controls, as well as to predict future fractures. In this cross-sectional analysis of data collected from 3 geographically dispersed facilities in the United States, we investigated age-related changes in the microarchitecture of lumbar vertebrae as assessed by TBS in a cohort of non-Hispanic US white American women. All subjects were 30 yr of age and older and had an L1-L4aBMDZ-score within ±2 SD of the population mean. Individuals were excluded if they had fractures, were on any osteoporosis treatment, or had any illness that would be expected to impact bone metabolism. All data were extracted from Prodigy dual-energy X-ray absorptiometry devices (GE-Lunar, Madison, WI). Cross-calibrations between the 3 participating centers were performed for TBS and aBMD. aBMD and TBS were evaluated for spine L1-L4 but also for all other possible vertebral combinations. To validate the cohort, a comparison between the aBMD normative data of our cohort and US non-Hispanic white Lunar data provided by the manufacturer was performed. A database of 619 non-Hispanic US white women, ages 30-90 yr, was created. aBMD normative data obtained from this cohort were not statistically different from the non-Hispanic US white Lunar normative data provided by the manufacturer (p = 0.30). This outcome thereby indirectly validates our cohort. TBS values at L1-L4 were weakly inversely correlated with body mass index (r = -0.17) and weight (r = -0.16) and not correlated with height. TBS values for all lumbar vertebral combinations decreased significantly with age. There was a linear decrease of 16.0% (-2.47 T-score) in TBS at L1-L4 between 45 and 90 yr of age (vs. -2.34 for aBMD). Microarchitectural loss rate increased after age 65 by 50% (-0.004 to -0.006). Similar results were obtained for other combinations of lumbar vertebra. TBS, an index of bone microarchitectural texture, decreases with advancing age in non-Hispanic US white women. Little change in TBS is observed between ages 30 and 45. Thereafter, a progressive decrease is observed with advancing age. The changes we observed in these American women are similar to that previously reported for a French population of white women (r(2) > 0.99). This reference database will facilitate the use of TBS to assess bone microarchitectural deterioration in clinical practice.
Resumo:
Lean meat percentage (LMP) is an important carcass quality parameter. The aim of this work is to obtain a calibration equation for the Computed Tomography (CT) scans with the Partial Least Square Regression (PLS) technique in order to predict the LMP of the carcass and the different cuts and to study and compare two different methodologies of the selection of the variables (Variable Importance for Projection — VIP- and Stepwise) to be included in the prediction equation. The error of prediction with cross-validation (RMSEPCV) of the LMP obtained with PLS and selection based on VIP value was 0.82% and for stepwise selection it was 0.83%. The prediction of the LMP scanning only the ham had a RMSEPCV of 0.97% and if the ham and the loin were scanned the RMSEPCV was 0.90%. Results indicate that for CT data both VIP and stepwise selection are good methods. Moreover the scanning of only the ham allowed us to obtain a good prediction of the LMP of the whole carcass.