937 resultados para Wind-induced Natural Ventilation
Resumo:
With significant population growth experienced in South East Queensland over the past two decades and a high rate of growth expected to continue in coming decades, the Queensland Government is promoting urban consolidation planning policies to manage growth sustainably. Multi-residential buildings will play an important role in facilitating the increased densities which urban consolidation policies imply. However, a major flood event in January 2011 has brought to light the vulnerability of certain types of multi-residential typologies to power outages. The crisis conditions exposed how contemporary building design and construction practices, coupled with regulatory and planning issues, appear to have compromised the resilience and habitability of multi-storey residential buildings. In the greater urban area of Brisbane, Queensland, the debilitating dependence that certain types of apartment buildings have on mains electricity was highlighted by residents’ experiences of the Brisbane River flood disaster, before, during and after the event. This research examined high density residential buildings in West End, Brisbane, an inner city suburb which was severely affected by the flood and is earmarked for significant urban densification under the Brisbane City Plan. Medium-to-high-density residential buildings in the suburb were mapped in flooded and non-flooded locations and a database containing information about the buildings was created. Parameters included date of construction, number of storeys, systems of access and circulation, and potential for access to natural light and ventilation for habitable areas. A series of semi-structured interviews were conducted with residents involved in the owners’ management committees of several buildings to verify information the mapping could not provide. The interviews identified a number of critical systems failures due to power outage which had a significant impact on residents’ wellbeing, comfort and safety. Building services such as lifts, running water, fire alarms, security systems and air-conditioning ceased to operate when power was disconnected to neighbourhoods and buildings in anticipation of rising flood waters. Lack of access to buildings and dwellings, lack of safety, lack of building security, and lack of thermal comfort affected many residents whether or not their buildings were actually subjected to inundation, with some buildings rendered uninhabitable for a prolonged period. The extent of the impact on residents was dramatically influenced by the scale and type of building inhabited, with those dwelling in buildings under a 25m height limit, with a single lift, found to be most affected. The energy-dependency and strong trend of increasing power demands of high-rise buildings is well-documented. Extended electricity outages such as the one brought about by the 2011 flood in Queensland are likely to happen more frequently than the 50-year average of the flood event itself. Electricity blackouts can result from a number of man-made or natural causes, including shortages caused by demand exceeding supply. This paper highlights the vulnerability of energy-dependent buildings to power outages and investigates options for energy security for occupants of multi-storey buildings and makes recommendations to increase resilience and general liveability in multi-residential buildings in the subtropics through design modifications.
Resumo:
Motor vehicle emissions have been identified as one of the major contributors of fine and ultrafine particles (UFP) in urban areas. Schools located near major roads could potentially be exposed to high levels of UPFs and school classroom is an important microenvironment where significant exposure to UFPs is likely to occur. Most of the research conducted to date has investigated the relationship between indoor and outdoor particle number concentration (PNC) in schools based on one outdoor location, which may introduce a level of error when calculating the variation of total UPFs, and can result in the underestimation or overestimation of indoor to outdoor (I/O) ratio values.
Resumo:
Saudi Arabia experiences housing shortage for mid and low-income families, which is caused by rapid population growth. This condition is worsened by the fact that the current housing supply has problems in meeting both sustainable requirements and cultural needs of those families. This paper aims to investigate the link between the unique conservative Saudi culture and the design of sustainable housing, while keeping the housing cost affordable for mid and low-income families. The paper is based on a review of literatures on the issues of the Islamic culture and how can they be integrated into the design process of a Saudi house. Findings from literature reveiw suggest several design requirements for accommodating the conservative Saudi Culture in low cost sustainable houses. Such requirements include the implementation of proper usage of windows, and house orientation with a courtyard inside rather than facing the main street will provide natural ventilation while maintaining privacy. The main contribution to the body of knowledge is that this is a new approach to sustainable housing in Saudi Arabia considering not only energy use and architectural design issues but also socio-cultural issues as an essential part of sustainability.
Resumo:
A key challenge for the 21st Century is to make our cities more liveable and foster economically sustainable, environmentally responsible, and socially inclusive communities. Design thinking, particularly a human-centred approach, offers a way to tackle this challenge. Findings from two recent Australian research projects highlight how facilitating sustainable, liveable communities in a humid sub-tropical environment requires an in-depth understanding of people’s perspectives, experiences and practices. Project 1 (‘Research House’) documents the reflections of a family who lived in a ‘test’ sustainable house for two years, outlining their experience and evaluations of universal design and sustainable technologies. The study family was very impressed with the natural lighting, natural ventilation, spaciousness and ease of access, which contributed significantly to their comfort and the liveability of their home. Project 2 (‘Inner-Urban High Density Living’) explored Brisbane residents’ opinions about high-density living, through a survey (n=636), interviews (n=24), site observations (over 300 hours) and environmental monitoring, assessing opinions on the liveability of their individual dwelling, the multi-unit host building and the surrounding neighbourhood. Nine areas, categorised into three general domains, were identified as essential for enhancing high density liveability. In terms of the dwelling, thermal comfort/ventilation, natural light, noise mitigation were important; shared space, good neighbour protocols, and support for environmentally sustainable behaviour were desired in the building/complex; and accessible/sustainable transport, amenities and services, sense of community were considered important in the surrounding neighbourhood. Combined, these findings emphasise the importance and complexity associated with designing liveable building, cities and communities, illustrating how adopting a design thinking, human-centred approach will help create sustainable communities that will meet the needs of current and future generations.
Resumo:
This was a comparative study of the possibility of a net zero energy house in Queensland, Australia. It examines the actual energy use and thermal comfort conditions of an occupied Brisbane home and compares performance with the 10 star scale rating scheme for Australian residential buildings. An adaptive comfort psychometric chart was developed for this analysis. The house's capacity for the use of the natural ventilation was studied by CFD modelling. This study showed that the house succeeded in achieving the definition of net zero energy on an annual and monthly basis for lighting, cooking and space heating / cooling and for 70% of days for lighting, hot water and cooking services.
Resumo:
Dwellings in multi-storey apartment buildings (MSAB) are predicted to increase dramatically as a proportion of housing stock in subtropical cities over coming decades. The problem of designing comfortable and healthy high-density residential environments and minimising energy consumption must be addressed urgently in subtropical cities globally. This paper explores private residents’ experiences of privacy and comfort and their perceptions of how well their apartment dwelling modulated the external environment in subtropical conditions through analysis of 636 survey responses and 24 interviews with residents of MSAB in inner urban neighbourhoods of Brisbane, Australia. The findings show that the availability of natural ventilation and outdoor private living spaces play important roles in resident perceptions of liveability in the subtropics where the climate is conducive to year round “outdoor living”. Residents valued choice with regard to climate control methods in their apartments. They overwhelmingly preferred natural ventilation to manage thermal comfort, and turned to the air-conditioner for limited periods, particularly when external conditions were too noisy. These findings provide a unique evidence base for reducing the environmental impact of MSAB and increasing the acceptability of apartment living, through incorporating residential attributes positioned around climate-responsive architecture.
Resumo:
Sediment resuspension, the return of the bottom material into the water column, is an important process that can have various effects on a lake ecosystem. Resuspension caused by wind-induced wave disturbance, currents, turbulent fluctuations and bioturbation affects water quality characteristics such as turbidity, light conditions, and concentrations of suspended solids (SS) and nutrients. Resuspension-mediated increase in turbidity may favour the dominance of phytoplankton over macrophytes. The predator-prey interactions contributing to the trophic state of a lake may also be influenced by increasing turbidity. Directly, the trophic state of a lake can be influenced by the effect of sediment resuspension on nutrient cycling. Resuspension enhances especially the cycling of phosphorus by bringing the sedimentary nutrients back into the water column and may thereby induce switches between phosphorus and nitrogen limitation. The contribution of sediment resuspension to gross sedimentation, turbidity, and concentration of SS and nutrients was studied in a small, deep lake as well as in a multibasin lake with deep and shallow areas. The effect of ice cover on sediment resuspension and thereby on phosphorus concentrations was also studied. The rates of gross sedimentation and resuspen¬sion were estimated with sediment traps and the associations between SS and nutrients were considered. Sediment resuspension, caused by wind activity, comprised most of the gross sedimenta¬tion and strongly contributed to the concentration of SS and turbidity in the lakes studied. Additionally, via the influence on SS, resuspension affected the concentration of total phosphorus (TP) and soluble reactive phosphorus (SRP), as well as the total nitrogen to total phosphorus (TN:TP) ratio. Although contrasting results concerning the dependence between the SS and SRP concentrations were observed, it could be concluded that sediment resuspension during strong algal blooms (pH > 9) led to aerobic release of P. The main findings of this thesis were that in the course of the growing season, sediment resuspension coupled with phytoplankton succession led to liberation of P from resuspended particles, which in turn resulted in high TP concentrations and low TN:TP ratios. This development was likely a cause of strong cyanobacterial blooms in midsummer.
Resumo:
This doctoral thesis is about the solar wind influence on the atmosphere of the planet Venus. A numerical plasma simulation model was developed for the interaction between Venus and the solar wind to study the erosion of charged particles from the Venus upper atmosphere. The developed model is a hybrid simulation where ions are treated as particles and electrons are modelled as a fluid. The simulation was used to study the solar wind induced ion escape from Venus as observed by the European Space Agency's Venus Express and NASA's Pioneer Venus Orbiter spacecraft. Especially, observations made by the ASPERA-4 particle instrument onboard Venus Express were studied. The thesis consists of an introductory part and four peer-reviewed articles published in scientific journals. In the introduction Venus is presented as one of the terrestrial planets in the Solar System and the main findings of the work are discussed within the wider context of planetary physics. Venus is the closest neighbouring planet to the Earth and the most earthlike planet in its size and mass orbiting the Sun. Whereas the atmosphere of the Earth consists mainly of nitrogen and oxygen, Venus has a hot carbon dioxide atmosphere, which is dominated by the greenhouse effect. Venus has all of its water in the atmosphere, which is only a fraction of the Earth's total water supply. Since planets developed presumably in similar conditions in the young Solar System, why Venus and Earth became so different in many respects? One important feature of Venus is that the planet does not have an intrinsic magnetic field. This makes it possible for the solar wind, a continuous stream of charged particles from the Sun, to flow close to Venus and to pick up ions from the planet's upper atmosphere. The strong intrinsic magnetic field of the Earth dominates the terrestrial magnetosphere and deflects the solar wind flow far away from the atmosphere. The region around Venus where the planet's atmosphere interacts with the solar wind is called the plasma environment or the induced magnetosphere. Main findings of the work include new knowledge about the movement of escaping planetary ions in the Venusian induced magnetosphere. Further, the developed simulation model was used to study how the solar wind conditions affect the ion escape from Venus. Especially, the global three-dimensional structure of the Venusian particle and magnetic environment was studied. The results help to interpret spacecraft observations around the planet. Finally, several remaining questions were identified, which could potentially improve our knowledge of the Venus ion escape and guide the future development of planetary plasma simulations.
Resumo:
An expression for the spectrum and cross spectrum of an acoustic field measured at two vertically separated sensors in shallow water has been obtained for any correlated noise sources distributed over the surface. Numerical results are presented for the case where the noise sources, white noise and wind-induced colored noise, are contained within a circular disk centered over the sensors. The acoustic field is generally inhomogeneous except when the channel is deep. The coherence function becomes real for a large disk, for a radius greater than 25 times the depth of the channel, decreases with further increase of the size of the disk, and finally tapers off after certain limiting size, approximately given by 1/alpha, where alpha is the attenuation coefficient.
Resumo:
该文基于对太湖地形和水动力特征的分析,建立了沿垂向平均的太湖二维浅水动力学模型,给出了模型参数和模型的数值求解方法.通过对太湖风生流的模拟,分析了太湖风生环流的基本形态特征,并得到了实测流场的良好验证.进一步对盛行风场下的太湖流场和水动力特征进行数值研究表明,太湖风生流的形成主要由风场、湖泊边界及湖底地形决定;得到了不同湖区的流动规律和水动力特征,并揭示了不同湖区流动差异的形成原因.
Resumo:
A racionalização do uso da energia elétrica nas edificações é um assunto atual e de grande importância face ao grande impacto ambiental produzido. O consumo de energia elétrica no Brasil nas edificações residenciais, comerciais, de serviços e públicas é bastante significativo. Calcula-se que quase 50% da energia elétrica produzida no país seja consumida não só na operação e manutenção das edificações como também nos sistemas artificiais, que proporcionam conforto ambiental para seus usuários como iluminação, climatização e aquecimento de água. O Regulamento Técnico de Qualidade do Nível de Eficiência Energética de Edifícios Comerciais e Serviços e Públicos, RQT-C do INMETRO surge como uma contribuição à etiquetagem do nível de eficiência energética das edificações de uso coletivo. Para a determinação da eficiência são considerados três requisitos: envoltória da edificação, sistema de iluminação e sistema de condicionamento de ar. Todos os requisitos têm cinco níveis de eficiência que variam de A (mais eficiente) até E (menos eficiente), que associados com algumas bonificações (uso da energia solar, ventilação natural, etc.) tornam possível a atribuição de uma classificação geral para o edifício em seu todo. Neste trabalho objetivou-se avaliar esse desempenho energético para o prédio do Instituto Brasileiro de Adminstração Municipal -IBAM, situado na cidade do Rio de Janeiro, de concepção modernista. Foi mostrado como as decisões arquitetônicas tomadas e o uso da ventilação natural podem influenciar na avaliação de sua eficiência energética.
Resumo:
A global wavenumber-3 dipole SST mode is showed to exist in the Southern Hemisphere subtropical climate variability in austral summer. A positive (negative) phase of the mode is characterized by cool (warm) SST anomalies in the east and warm (cool) SST anomalies in the southwest of the south Indian, Pacific, and Atlantic Oceans, respectively. This coherent dipole structure is largely a response of ocean mixed layer to the atmospheric forcing characterized by migration and modulation of the subtropical high-pressures, in which the latent heat flux play a leading role through wind-induced evaporation, although ocean dynamics may also be crucial in forming SST anomalies attached to the continents. Exploratory analyses suggest that this mode is strongly damped by the negative heat flux feedback, with a persistence time about three months and no spectral peak at interannual to decadal time scales. As the subtropical dipole mode is linearly independent of ENSO and SAM, whether it represents an additional source of climate predictability should be further studied. Citation: Wang, F. (2010), Subtropical dipole mode in the Southern Hemisphere: A global view, Geophys. Res. Lett., 37, L10702, doi: 10.1029/2010GL042750.
Resumo:
The strength of the North Atlantic Current (NAC) (based on sea-surface elevation sloped derived from altimeter data) is correlated with westerly winds (based on North Atlantic Oscillation [NAO] Index data over a nine year period [1992-2002] with 108 monthly values). The data time window includes the major change in climate forcing over the last 100 years (1995 to 1996). It is shown that the NAO Index can be used for early earning of system failure for the NAC. The correlation response or early warning time scale for western Europe and south England is six months. The decay scale for the NAC and Subtropical Gyre circulation is estimated as three years. Longer period altimeter elevation/circulation changes are discussed. The sea-surface temperature (SST) response of the North Sea to negative and positive NAO conditions is examined. The overall temperature response for the central North Sea to NAO index forcing, reflecting wind induced inflow, shelf circulation and local climate forcing, is similar to 5 months. In years with strong North Atlantic winter wind induced inflow, under marked NAO positive conditions, mean temperatures ( similar to 10.5 degree C) are about 1 degree C warmer than under negative conditions. In 1996 under extreme negative winter NAO conditions, the North Sea circulation stopped, conditions near the Dogger Bank became more continentally influenced and the winter (March) temperature fell to 3.1 degree C whereas in 1995 under NAO positive winter conditions the minimum temperature was 6.4 degree C (February). Seasonal advance of North Atlantic and North Sea temperature is derived in relation to temperature change. Temperature change and monthly NAO Index are discussed with respect to phytoplankton blooms, chlorophyll-a measurements, ocean colour data and the anomalous north-eastern Atlantic 2002 spring/summer bloom SeaWiFS chlorophyll concentrations.
Resumo:
Many established models of animal foraging assume that individuals are ecologically equivalent. However, it is increasingly recognized that populations may comprise individuals who differ consistently in their diets and foraging behaviors. For example, recent studies have shown that individual foraging site fidelity (IFSF, when individuals consistently forage in only a small part of their population's home range) occurs in some colonial breeders. Short‐term IFSF could result from animals using a win–stay, lose–shift foraging strategy. Alternatively, it may be a consequence of individual specialization. Pelagic seabirds are colonial central‐place foragers, classically assumed to use flexible foraging strategies to target widely dispersed, spatiotemporally patchy prey. However, tracking has shown that IFSF occurs in many seabirds, although it is not known whether this persists across years. To test for long‐term IFSF and to examine alternative hypotheses concerning its cause, we repeatedly tracked 55 Northern Gannets (Morus bassanus) from a large colony in the North Sea within and across three successive breeding seasons. Gannets foraged in neritic waters, predictably structured by tidal mixing and thermal stratification, but subject to stochastic, wind‐induced overturning. Both within and across years, coarse to mesoscale (tens of kilometers) IFSF was significant but not absolute, and foraging birds departed the colony in individually consistent directions. Carbon stable isotope ratios in gannet blood tissues were repeatable within years and nitrogen ratios were also repeatable across years, suggesting long‐term individual dietary specialization. Individuals were also consistent across years in habitat use with respect to relative sea surface temperature and in some dive metrics, yet none of these factors accounted for IFSF. Moreover, at the scale of weeks, IFSF did not decay over time and the magnitude of IFSF across years was similar to that within years, suggesting that IFSF is not primarily the result of win–stay, lose–shift foraging. Rather, we hypothesize that site familiarity, accrued early in life, causes IFSF by canalizing subsequent foraging decisions. Evidence from this and other studies suggests that IFSF may be common in colonial central‐place foragers, with far‐reaching consequences for our attempts to understand and conserve these animals in a rapidly changing environment.
Resumo:
Well planned natural ventilation strategies and systems in the built environments may provide healthy and comfortable indoor conditions, while contributing to a significant reduction in the energy consumed by buildings. Computational Fluid Dynamics (CFD) is particularly suited for modelling indoor conditions in naturally ventilated spaces, which are difficult to predict using other types of building simulation tools. Hence, accurate and reliable CFD models of naturally ventilated indoor spaces are necessary to support the effective design and operation of indoor environments in buildings. This paper presents a formal calibration methodology for the development of CFD models of naturally ventilated indoor environments. The methodology explains how to qualitatively and quantitatively verify and validate CFD models, including parametric analysis utilising the response surface technique to support a robust calibration process. The proposed methodology is demonstrated on a naturally ventilated study zone in the library building at the National University of Ireland in Galway. The calibration process is supported by the on-site measurements performed in a normally operating building. The measurement of outdoor weather data provided boundary conditions for the CFD model, while a network of wireless sensors supplied air speeds and air temperatures inside the room for the model calibration. The concepts and techniques developed here will enhance the process of achieving reliable CFD models that represent indoor spaces and provide new and valuable information for estimating the effect of the boundary conditions on the CFD model results in indoor environments. © 2012 Elsevier Ltd.