930 resultados para Voltage ranges
Resumo:
Direction-selective retinal ganglion cells show an increased activity evoked by light stimuli moving in the preferred direction. This selectivity is governed by direction-selective inhibition from starburst amacrine cells occurring during stimulus movement in the opposite or null direction. To understand the intrinsic membrane properties of starburst cells responsible for direction-selective GABA release, we performed whole-cell recordings from starburst cells in mouse retina. Voltage-clamp recordings revealed prominent voltage-dependent K+ currents. The currents were mostly blocked by 1 mm TEA, activated rapidly at voltages more positive than -20 mV, and deactivated quickly, properties reminiscent of the currents carried by the Kv3 subfamily of K+ channels. Immunoblots confirmed the presence of Kv3.1 and Kv3.2 proteins in retina and immunohistochemistry revealed their expression in starburst cell somata and dendrites. The Kv3-like current in starburst cells was absent in Kv3.1-Kv3.2 knock-out mice. Current-clamp recordings showed that the fast activation of the Kv3 channels provides a voltage-dependent shunt that limits depolarization of the soma to potentials more positive than -20 mV. This provides a mechanism likely to contribute to the electrical isolation of individual starburst cell dendrites, a property thought essential for direction selectivity. This function of Kv3 channels differs from that in other neurons where they facilitate high-frequency repetitive firing. Moreover, we found a gradient in the intensity of Kv3.1b immunolabeling favoring proximal regions of starburst cells. We hypothesize that this Kv3 channel gradient contributes to the preference for centrifugal signal flow in dendrites underlying direction-selective GABA release from starburst amacrine cells.
Resumo:
Peripheral neuropathic pain is a disabling condition resulting from nerve injury. It is characterized by the dysregulation of voltage-gated sodium channels (Navs) expressed in dorsal root ganglion (DRG) sensory neurons. The mechanisms underlying the altered expression of Navs remain unknown. This study investigated the role of the E3 ubiquitin ligase NEDD4-2, which is known to ubiquitylate Navs, in the pathogenesis of neuropathic pain in mice. The spared nerve injury (SNI) model of traumatic nerve injury-induced neuropathic pain was used, and an Nav1.7-specific inhibitor, ProTxII, allowed the isolation of Nav1.7-mediated currents. SNI decreased NEDD4-2 expression in DRG cells and increased the amplitude of Nav1.7 and Nav1.8 currents. The redistribution of Nav1.7 channels toward peripheral axons was also observed. Similar changes were observed in the nociceptive DRG neurons of Nedd4L knockout mice (SNS-Nedd4L-/-). SNS-Nedd4L-/- mice exhibited thermal hypersensitivity and an enhanced second pain phase after formalin injection. Restoration of NEDD4-2 expression in DRG neurons using recombinant adenoassociated virus (rAAV2/6) not only reduced Nav1.7 and Nav1.8 current amplitudes, but also alleviated SNI-induced mechanical allodynia. These findings demonstrate that NEDD4-2 is a potent posttranslational regulator of Navs and that downregulation of NEDD4-2 leads to the hyperexcitability of DRG neurons and contributes to the genesis of pathological pain.
Resumo:
Line converters have become an attractive AC/DC power conversion solution in industrial applications. Line converters are based on controllable semiconductor switches, typically insulated gate bipolar transistors. Compared to the traditional diode bridge-based power converters line converters have many advantageous characteristics, including bidirectional power flow, controllable de-link voltage and power factor and sinusoidal line current. This thesis considers the control of the lineconverter and its application to power quality improving. The line converter control system studied is based on the virtual flux linkage orientation and the direct torque control (DTC) principle. A new DTC-based current control scheme is introduced and analyzed. The overmodulation characteristics of the DTC converter are considered and an analytical equation for the maximum modulation index is derived. The integration of the active filtering features to the line converter isconsidered. Three different active filtering methods are implemented. A frequency-domain method, which is based on selective harmonic sequence elimination, anda time-domain method, which is effective in a wider frequency band, are used inharmonic current compensation. Also, a voltage feedback active filtering method, which mitigates harmonic sequences of the grid voltage, is implemented. The frequency-domain and the voltage feedback active filtering control systems are analyzed and controllers are designed. The designs are verified with practical measurements. The performance and the characteristics of the implemented active filtering methods are compared and the effect of the L- and the LCL-type line filteris discussed. The importance of the correct grid impedance estimate in the voltage feedback active filter control system is discussed and a new measurement-based method to obtain it is proposed. Also, a power conditioning system (PCS) application of the line converter is considered. A new method for correcting the voltage unbalance of the PCS-fed island network is proposed and experimentally validated.
Resumo:
The supply voltage decrease and powerconsumption increase of modern ICs made the requirements for low voltage fluctuation caused by packaging and on-chip parasitic impedances more difficult to achieve. Most of the research works on the area assume that all the nodes of the chip are fed at thesame voltage, in such a way that the main cause of disturbance or fluctuation is the parasitic impedance of packaging. In the paper an approach to analyze the effect of high and fast current demands on the on-chip power supply network. First an approach to model the entire network by considering a homogeneous conductive foil is presented. The modification of the timing parameters of flipflops caused by spatial voltage drops through the IC surface are also investigated.
Resumo:
Background: The divergent glacial histories of southern and northern Europe affect present-day species diversity at coarse-grained scales in these two regions, but do these effects also penetrate to the more fine-grained scales of local communities?Methodology/Principal Findings: We carried out a cross-scale analysis to address this question for vascular plants in two mountain regions, the Alps in southern Europe and the Scandes in northern Europe, using environmentally paired vegetation plots in the two regions (n = 403 in each region) to quantify four diversity components: (i) total number of species occurring in a region (total gamma-diversity), (ii) number of species that could occur in a target plot after environmental filtering (habitat-specific gamma-diversity), (iii) pair-wise species compositional turnover between plots (plot-to-plot beta-diversity) and (iv) number of species present per plot (plot gamma-diversity). We found strong region effects on total gamma-diversity, habitat-specific gamma-diversity and plot-to-plot beta-diversity, with a greater diversity in the Alps even towards distances smaller than 50 m between plots. In contrast, there was a slightly greater plot alpha-diversity in the Scandes, but with a tendency towards contrasting region effects on high and low soil-acidity plots.Conclusions/Significance: We conclude that there are strong regional differences between coarse-grained (landscape- to regional-scale) diversity components of the flora in the Alps and the Scandes mountain ranges,but that these differences do not necessarily penetrate to the finest-grained (plot-scale) diversity component, at least not on acidic soils. Because different processes can lead to a similar pattern, we discuss the consistency of our results with Quaternary history and other divergent features between the two regions such as habitat connectivity, selection for vagility and environmental differences not accounted for in our analyses
Resumo:
Tässä työssä on tutkittu tasasähkönsiirron tuomia mahdollisuuksia sähkönjakelussa, kun pienjännitedirektiivin pienjännitemäärittelyn soveltamista laajennetaan koskemaan vaihtojännitteen lisäksi myös tasajännitettä. Aiemmin tasasähköjärjestelmiä on käytetty ainoastaan sähköistymisen alkuaikoina 1900-luvun alussa. Viime vuosikymmeninä on sähkönjakelussa käytetty pelkästään vaihtosähköverkkoja, koska tehoelektronisten laitteiden korkea hintataso ja tekniset ominaisuudet ovat mahdollistaneet tasasähkön käytön vain suurjännitteellä. Suomalaisten sähkönkäyttö on lisääntynyt muutamalla prosenttiyksiköllä vuosittain ja kasvun taantumista ei ole odotettavissa lähiaikoina. Samaan aikaan yhteiskunta muuttuu jatkuvasti yhä riippuvaisemmaksi sähköstä ja odotukset toteutuvasta sähkönlaadusta ovat jatkuvasti korkeammat. Sähkönlaadun näkökulmasta ilmasto on tuonut aiempia suurempia haasteita sähkön toimitusvarmuudelle, kun myrskyjen aiheuttamat tuhot ovat olleet yhä entisiä suurempia. Toimitusvarmuuden parantamiseksi ovat muutamat vuosikymmenen alun rajut myrskyt johtaneet pohdintaan tulevien haasteiden hoitamiseksi ja edelleen uuden 3-portaiseen 20/1/0,4 kV vaihtosähköjärjestelmän kehittämiseen. Tasasähkönsiirron avulla halutaan tuoda käyttöön niitä hyötyjä, joita järjestelmän vaihdolla on saavutettavissa. Täysimääräisellä tasajännitteen hyödyntämisellä voidaan saavuttaa mm. aiempaa edullisempia investointivaihtoehtoja,parempi sähkönlaatu, parempi hajautetun tuotannon liitettävyys verkkoon ja erilaisten asiakaskohtaisten laitteiden helppo integroitavuus osaksi jakelujärjestelmää. Tämän työn puitteissa on pohdittu sekä teknisiä ratkaisuja että järjestelmän teknistaloudellista käyttöaluetta. Lisäksi on pyritty hahmottamaan eri tekijöiden vaikutuksia sähkönjakeluun.
Resumo:
A mathematical model of the voltage drop which arises in on-chip power distribution networks is used to compare the maximum voltage drop in the case of different geometric arrangements of the pads supplying power to the chip. These include the square or Manhattan power pad arrangement, which currently predominates, as well as equilateral triangular and hexagonal arrangements. In agreement with the findings in the literature and with physical and SPICE models, the equilateral triangular power pad arrangement is found to minimize the maximum voltage drop. This headline finding is a consequence of relatively simple formulas for the voltage drop, with explicit error bounds, which are established using complex analysis techniques, and elliptic functions in particular.
Resumo:
Voltage-gated sodium channels (Navs) are glycoproteins composed of a pore-forming α-subunit and associated β-subunits that regulate Nav α-subunit plasma membrane density and biophysical properties. Glycosylation of the Nav α-subunit also directly affects Navs gating. β-subunits and glycosylation thus comodulate Nav α-subunit gating. We hypothesized that β-subunits could directly influence α-subunit glycosylation. Whole-cell patch clamp of HEK293 cells revealed that both β1- and β3-subunits coexpression shifted V ½ of steady-state activation and inactivation and increased Nav1.7-mediated I Na density. Biotinylation of cell surface proteins, combined with the use of deglycosydases, confirmed that Nav1.7 α-subunits exist in multiple glycosylated states. The α-subunit intracellular fraction was found in a core-glycosylated state, migrating at ~250 kDa. At the plasma membrane, in addition to the core-glycosylated form, a fully glycosylated form of Nav1.7 (~280 kDa) was observed. This higher band shifted to an intermediate band (~260 kDa) when β1-subunits were coexpressed, suggesting that the β1-subunit promotes an alternative glycosylated form of Nav1.7. Furthermore, the β1-subunit increased the expression of this alternative glycosylated form and the β3-subunit increased the expression of the core-glycosylated form of Nav1.7. This study describes a novel role for β1- and β3-subunits in the modulation of Nav1.7 α-subunit glycosylation and cell surface expression.
Resumo:
Abstract The cardiac sodium channel Nav1.5 plays a key role in cardiac excitability and conduction. Its importance for normal cardiac function has been highlighted by descriptions of numerous mutations of SCN5A (the gene encoding Nav1.5), causing cardiac arrhythmias which can lead to sudden cardiac death. The general aim of my PhD research project has been to investigate the regulation of Nav1.5 along two main axes: (1) We obtained experimental evidence revealing an interaction between Nav1.5 and a multiprotein complex comprising dystrophin. The first part of this study reports the characterization of this interaction. (2) The second part of the study is dedicated to the regulation of the cardiac sodium channel by the mineralocorticoid hormone named aldosterone. (1) Early in this study, we showed that Nav1.5 C-terminus was associated with dystrophin and that this interaction was mediated by syntrophin proteins. We used dystrophin-deficient mdx5cv mice to study the role of this interaction. We reported that dystrophin deficiency led to a reduction of both Nav1.5 protein level and the sodium current (INa). We also found that mdx5cv mice displayed atrial and ventricular conduction defects. Our results also indicated that proteasome inhibitor MG132 treatment of mdx5cv mice rescued Nav1.5 protein level and INa in cardiac tissue. (2) We showed that aldosterone treatment of mice cardiomyocytes led to an increase of the sodium current with no modification of Nav1.5 transcript and protein level. Altogether, these results suggest that the sodium current can be increased by distribution of intracellular pools of protein to the plasma membrane (e.g. upon aldosterone stimulation) and that interaction with dystrophin multiprotein complex is required for the stabilization of the channel at the plasma membrane. Finally, we obtained preliminary results suggesting that the proteasome could regulate Nav1.5 in mdx5cv mice. This study defines regulatory mechanisms of Nav1.5 which could play an important role in cardiac arrhythmia and bring new insight in cardiac conduction alterations observed in patients with dystrophinopathies. Moreover, this work suggests that Brugada syndrome, and some of the cardiac alterations seen in Duchenne patients may be caused by overlapping molecular mechanisms leading to a reduction of the cardiac sodium current.
Resumo:
Pulsewidth-modulated (PWM) rectifier technology is increasingly used in industrial applications like variable-speed motor drives, since it offers several desired features such as sinusoidal input currents, controllable power factor, bidirectional power flow and high quality DC output voltage. To achieve these features,however, an effective control system with fast and accurate current and DC voltage responses is required. From various control strategies proposed to meet these control objectives, in most cases the commonly known principle of the synchronous-frame current vector control along with some space-vector PWM scheme have been applied. Recently, however, new control approaches analogous to the well-established direct torque control (DTC) method for electrical machines have also emerged to implement a high-performance PWM rectifier. In this thesis the concepts of classical synchronous-frame current control and DTC-based PWM rectifier control are combined and a new converter-flux-based current control (CFCC) scheme is introduced. To achieve sufficient dynamic performance and to ensure a stable operation, the proposed control system is thoroughly analysed and simple rules for the controller design are suggested. Special attention is paid to the estimationof the converter flux, which is the key element of converter-flux-based control. Discrete-time implementation is also discussed. Line-voltage-sensorless reactive reactive power control methods for the L- and LCL-type line filters are presented. For the L-filter an open-loop control law for the d-axis current referenceis proposed. In the case of the LCL-filter the combined open-loop control and feedback control is proposed. The influence of the erroneous filter parameter estimates on the accuracy of the developed control schemes is also discussed. A newzero vector selection rule for suppressing the zero-sequence current in parallel-connected PWM rectifiers is proposed. With this method a truly standalone and independent control of the converter units is allowed and traditional transformer isolation and synchronised-control-based solutions are avoided. The implementation requires only one additional current sensor. The proposed schemes are evaluated by the simulations and laboratory experiments. A satisfactory performance and good agreement between the theory and practice are demonstrated.
Resumo:
IIn electric drives, frequency converters are used to generatefor the electric motor the AC voltage with variable frequency and amplitude. When considering the annual sale of drives in values of money and units sold, the use of low-performance drives appears to be in predominant. These drives have tobe very cost effective to manufacture and use, while they are also expected to fulfill the harmonic distortion standards. One of the objectives has also been to extend the lifetime of the frequency converter. In a traditional frequency converter, a relatively large electrolytic DC-link capacitor is used. Electrolytic capacitors are large, heavy and rather expensive components. In many cases, the lifetime of the electrolytic capacitor is the main factor limiting the lifetime of the frequency converter. To overcome the problem, the electrolytic capacitor is replaced with a metallized polypropylene film capacitor (MPPF). The MPPF has improved properties when compared to the electrolytic capacitor. By replacing the electrolytic capacitor with a film capacitor the energy storage of the DC-linkwill be decreased. Thus, the instantaneous power supplied to the motor correlates with the instantaneous power taken from the network. This yields a continuousDC-link current fed by the diode rectifier bridge. As a consequence, the line current harmonics clearly decrease. Because of the decreased energy storage, the DC-link voltage fluctuates. This sets additional conditions to the controllers of the frequency converter to compensate the fluctuation from the supplied motor phase voltages. In this work three-phase and single-phase frequency converters with small DC-link capacitor are analyzed. The evaluation is obtained with simulations and laboratory measurements.
Resumo:
Sähkönjakeluverkkojen kehittäminen nykyistä käyttövarmemmiksi ja taloudellisemmiksi vaatii jatkuvasti uusia ratkaisumalleja. Lupaavaksi tekniikaksi sähkönjakeluverkkojen kehittämisessä on osoittautumassa tasasähkönjakelu tehoelektronisten komponenttien kehittyessä ja hintojen laskiessa samanaikaisesti. Pienjännitedirektiivi mahdollistaa tasajännitteen myötä aiempaa suurempien jännitteiden käytön pienjänniteverkoissa. Tasajännitteen käytöllä voidaan saavuttaa etuja mm. tehonsiirtokyvyssä, sähkönlaadussa, käyttövarmuudessa sekä kustannuksissa. Työssä tehdään yksityiskohtaisia teknistaloudellisia tarkasteluja perinteistä 20/0,4 kV tekniikkaa, 1000 V sähkönjakelua sekä tasasähköjärjestelmiä hyödyntäen ja verrataan näiden järjestelmien kustannuksia ja ominaisuuksia toisiinsa. Tutkimusalueet on valittu Fortum Sähkönsiirto Oy:n maaseutu- ja taajamaverkoista. Työssä pyritään hahmotta-maan teknistaloudellista käyttöaluetta eri tasasähkönjakelujärjestelmille sekä määrittä-mään tasasähkönjakelun käyttöpotentiaali tutkimuskohteena olleissa verkoissa. Lisäksi tutkitaan eri tekijöiden vaikutuksia tasasähköjakelun kannattavuuteen ja käyttövarmuu-teen sekä pyritään tuomaan esiin muitakin tasasähkönjakelujärjestelmien ominaisuuksia.
Resumo:
The structural position of the Upper Jurassic-Lower Cretaceous carbonates located in the central part of the Catalan Coastal Ranges corresponds to the southwestern end of the Vallès-Penedès Fault. This fault was reactivated at different times during successive extensional and compressional events and several generations of fractures and cementations were formed.
Resumo:
The hercynian outcrops of the Catalonian Coastal Ranges (NE Spain) consist mainly of Lower Permian-Upper Carboniferous, post-tectonic, epizona1 granitoid intrusions which form a typical applutonic calc-alkaline suite ranging from mafic hornblende gabbros and ultramafic olivine homblendites throught on alites and granodioritcs to leucogranites. This suite displays major andtrace-element characteristics and Sr isotope ratios similar to volcanic arc and post-collision magmatism oceanic lithosphere and to have been modified by contamination and is therefore believed to have formed above subducted with melts from the crust
Resumo:
Paleozoic rocks in the Catalonian Coastal Ranges are in their largestpart affectedby alow-tovery-low grade Hercynian metamorphism. Amphibolite facies conditions are only found in restricted areas such as the southwestern part of the Guilleries massif where upper amphibolite facies conditions are reached. Metamorphic grade increases from top to bottom of the Paleozoic stratigraphic sequence and the metamorphic peak is diachronous, being progressively older in the lower grade metamorphic zones. The isograd pattern, mineral assemblages, mineral chemistry and preserved reaction textures are consistent with a low pressure metamorphism possibly evolving from a previous Barrovian type event. The metamorphic climax in the high grade zone was reached after the seconddeformational phase. Calculatedpeak P-Tconditions are 620-640 OC and around 3.5 Kb . A latter episode of decompression from the maximum conditions to 1-2 Kb, with an associated temperature decrease to 530-550 OC, is recognized. The intrusion of late Hercynian granitoids produced contact metamorphic aureoles where the pyroxene-hornfels facies is locally reached.