996 resultados para Voltage dependence


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper analyzes the performance of some of the widely used voltage stability indices, namely, singular value, eigenvalue, and loading margin with different static load models. Well-known ZIP model is used to represent loads having components with different power to voltage sensitivities. Studies are carried out on a 10-bus power system and the New England 39-bus power system models. The effects of variation of load model on the performance of the voltage stability indices are discussed. The choice of voltage stability index in the context of load modelling is also suggested in this paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents dynamic hysteresis band height control to reduce the overshoot and undershoot issue on output voltage caused by load change. The converters in this study are Boost and Positive Buck-Boost (PBB) converters. PBB has been controlled to work in a step up conversion and avoid overshoot when load is changed. Simulation and experimental results have been presented to verify the proposed method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an Active Gate Signaling scheme to reduce voltage/current spikes across insulated gate power switches in hard switching power electronic circuits. Voltage and/or current spikes may cause EMI noise. In addition, they increase voltage/current stress on the switch. Traditionally, a higher gate resistance is chosen to reduce voltage/current spikes. Since the switching loss will increase remarkably, an active gate voltage control scheme is developed to improve efficiency of hard switching circuits while the undesirable voltage and/or current spikes are minimized.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Positive Buck- Boost (PBB) converter is a known DC-DC converter that can operate in step up and step down modes. Unlike Buck, Boost, and Inverting Buck Boost converters, the inductor current of a PBB can be controlled independently of its voltage conversion ratio. In other words, the inductor of PBB can be utilised as an energy storage unit in addition to its main function of energy transfer. In this paper, the capability of PBB to store energy has been utilised to achieve robustness against input voltage fluctuations and output current changes. The control strategy has been developed to keep accuracy, affordability, and simplicity acceptable. To improve the efficiency of the system a Smart Load Controller (SLC) has been suggested. Applying SLC extra current storage occurs when there is sudden loads change otherwise little extra current is stored.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is no specific self-efficacy measure that has been developed primarily for problem drinkers seeking a moderation drinking goal. In this article, we report the factor structure of a 20-item Controlled Drinking Self-Efficacy Scale (CDSES; Sitharthan et al., 1996; Sitharthan et al., 1997). The results indicate that the CDSES is highly reliable, and the factor analysis using the full sample identified four factors: negative affect, positive mood/social context, frequency of drinking, and consumption quantity. A similar factor structure was obtained for the subsample of men. In contrast, only three factors emerged in the analysis of data on female participants. Compared to women, men had low self-efficacy to control their drinking in situations relating to positive mood/social context, and subjects with high alcohol dependence had low self-efficacy for situations relating to negative affect, social situations, and drinking less frequently. The CDSES can be a useful measure in treatment programs providing a moderation drinking goal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To allocate and size capacitors in a distribution system, an optimization algorithm, called Discrete Particle Swarm Optimization (DPSO), is employed in this paper. The objective is to minimize the transmission line loss cost plus capacitors cost. During the optimization procedure, the bus voltage, the feeder current and the reactive power flowing back to the source side should be maintained within standard levels. To validate the proposed method, the semi-urban distribution system that is connected to bus 2 of the Roy Billinton Test System (RBTS) is used. This 37-bus distribution system has 22 loads being located in the secondary side of a distribution substation (33/11 kV). Reducing the transmission line loss in a standard system, in which the transmission line loss consists of only about 6.6 percent of total power, the capabilities of the proposed technique are seen to be validated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: To determine the reliability and validity of the Severity of Dependence Scale (SDS) for detecting cannabis dependence in a large sample of in-patients with a schizophrenia spectrum disorder. Design: Cross-sectional study. Participants: Participants were 153 in-patients with a schizophrenia spectrum disorder in Brisbane, Australia. Measurements: Participants were administered the SDS for cannabis dependence in the past 12 months. The presence of Diagnostic and Statistical Manual Version-IV (DSM-IV) cannabis dependence in the previous 12 months was assessed using the Comprehensive International Diagnostic Interview (CIDI). Findings: The SDS had high levels of internal consistency and strong construct and concurrent validity. Individuals with a score of ≥2 on the SDS were nearly 30 times more likely to have DSM-IV cannabis dependence. The SDS was the strongest predictor of DSM-IV cannabis dependence after controlling for other predictor variables. Conclusions: The SDS is a brief, valid and reliable screen for cannabis dependence among people with psychosis