940 resultados para Veterinary instruments and apparatus


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The optical power of a thick spherical lens and its Coddington shape factor are essential magnitudes that characterize its image quality. Here, we propose an experimental procedure and apparatus that allow accurate determination of those magnitudes for any spherical lens from geometrical measurements. The performance of the technique and the used instruments are simple since it only requires a microscope and an optical mouse. The propose overcomes the drawbacks of other devices that need of the refractive index or may damage the lens surfaces, like spherometers, and provides similar results to those from commercial lensmeters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"Must be used with the author catalogue [Index-catalogue of medical and veterinary zoology: authors, of the U.S. Bureau of Animal Industry, Zoological Division] ... the bibiliographical key."

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The measurement of broadband ultrasonic attenuation (BUA) in cancellous bone at the calcaneus was first described in 1984. The assessment of osteoporosis by BUA has recently been recognized by Universities UK, within its EurekaUK book, as being one of the “100 discoveries and developments in UK Universities that have changed the world” over the past 50 years, covering the whole academic spectrum from the arts and humanities to science and technology. Indeed, BUA technique has been clinically validated and is utilized worldwide, with at least seven commercial systems providing calcaneal BUA measurement. However, a fundamental understanding of the dependence of BUA upon the material and structural properties of cancellous bone is still lacking. This review aims to provide a science- and technology-orientated perspective on the application of BUA to the medical disease of osteoporosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hourly rounding in the acute hospital setting has been proposed as an intervention to increase patient satisfaction and safety, and improve the nursing practice environment, but the innovation has not been adequately tested. A quasiexperimental pretest post-test non-randomized parallel group trial design was used to test the effect of hourly patient comfort rounds on patient satisfaction and nursing perceptions of the practice environment, and to evaluate research processes and instruments for a proposed larger study. A Patient Satisfaction Survey instrument was developed and used in conjunction with the Practice Environment Scale of the Nursing Work Index. Results on patient satisfaction showed no significant changes. Significant changes were found for three of the five practice environment subscales. Consistent with the aim of a pilot study, this research has provided important information related to design, instruments and process that will inform a larger sufficiently powered study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Preterm infants have an increased risk of low bone mass and subsequent fracture due to limited bone mass accretion in utero and a greater need for bone nutrients. The diagnosis of ostepeonia of prematurity remains difficult as there is no sctreening test which is both sensitive and specific.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bone mineral density (BMD) is currently the preferred surrogate for bone strength in clinical practice. Finite element analysis (FEA) is a computer simulation technique that can predict the deformation of a structure when a load is applied, providing a measure of stiffness (N mm− 1). Finite element analysis of X-ray images (3D-FEXI) is a FEA technique whose analysis is derived from a single 2D radiographic image. This ex-vivo study demonstrates that 3D-FEXI derived from a conventional 2D radiographic image has the potential to significantly increase the accuracy of failure load assessment of the proximal femur compared with that currently achieved with BMD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper examines three functions of music technology in the study of music. Firstly, as a tool, secondly, as an instrument and, lastly, as a medium for thinking. As our societies become increasingly embroiled in digital media for representation and communication, our philosophies of music education need to adapt to integrate these developments while maintaining the essence of music. The foundation of music technology in the 1990s is the digital representation of sound. It is this fundamental shift to a new medium with which to represent sound that carries with it the challenge to address digital technology and its multiple effects on music creation and presentation. In this paper I suggest that music institutions should take a broad and integrated approach to the place of music technology in their courses, based on the understanding of digital representation of sound and these three functions it can serve. Educators should reconsider digital technologies such as synthesizers and computers as music instruments and cognitive amplifiers, not simply as efficient tools.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the field of leadership studies transformational leadership theory (e.g., Bass, 1985; Avolio, Bass, & Jung, 1995) has received much attention from researchers in recent years (Hughes, Ginnet, & Curphy, 2009; Hunt, 1999). Many previous studies have found that transformational leadership is related to positive outcomes such as the satisfaction, motivation and performance of followers in organisations (Judge & Piccolo, 2004; Lowe, Kroeck, & Sivasubramaniam, 1996), including in educational institutions (Chin, 2007; Leithwoood & Jantzi, 2005). Hence, it is important to explore constructs that may predict leadership style in order to identify potential transformational leaders in leadership assessment and selection procedures. Several researchers have proposed that emotional intelligence (EI) is one construct that may account for hitherto unexplained variance in transformational leadership (Mayer, 2001; Watkin, 2000). Different models of EI exist (e.g., Goleman, 1995, 2001; Bar-On, 1997; Mayer & Salovey, 1997) but momentum is growing for the Mayer and Salovey (1997) model to be considered the most useful (Ashkanasy & Daus, 2005; Daus & Ashkanasy, 2005). Studies in non-educational settings claim to have found that EI is a useful predictor of leadership style and leader effectiveness (Harms & Crede, 2010; Mills, 2009) but there is a paucity of studies which have examined the Mayer and Salovey (1997) model of EI in educational settings. Furthermore, other predictor variables have rarely been controlled in previous studies and only self-ratings of leadership behaviours, rather than multiple ratings, have usually been obtained. Therefore, more research is required in educational settings to answer the question: to what extent is the Mayer and Salovey (1997) model of EI a useful predictor of leadership style and leadership outcomes? This project, set in Australian educational institutions, was designed to move research in the field forward by: using valid and reliable instruments, controlling for other predictors, obtaining an adequately sized sample of real leaders as participants and obtaining multiple ratings of leadership behaviours. Other variables commonly used to predict leadership behaviours (personality factors and general mental ability) were assessed and controlled in the project. Additionally, integrity was included as another potential predictor of leadership behaviours as it has previously been found to be related to transformational leadership (Parry & Proctor-Thomson, 2002). Multiple ratings of leadership behaviours were obtained from each leader and their supervisors, peers and followers. The following valid and reliable psychological tests were used to operationalise the variables of interest: leadership styles and perceived leadership outcomes (Multifactor Leadership Questionnaire, Avolio et al., 1995), EI (Mayer–Salovey–Caruso Emotional Intelligence Test, Mayer, Salovey, & Caruso, 2002), personality factors (The Big Five Inventory, John, Donahue, & Kentle, 1991), general mental ability (Wonderlic Personnel Test-Quicktest, Wonderlic, 2003) and integrity (Integrity Express, Vangent, 2002). A Pilot Study (N = 25 leaders and 75 raters) made a preliminary examination of the relationship between the variables included in the project. Total EI, the experiential area, and the managing emotions and perceiving emotions branches of EI, were found to be related to transformational leadership which indicated that further research was warranted. In the Main Study, 144 leaders and 432 raters were recruited as participants to assess the discriminant validity of the instruments and examine the usefulness of EI as a predictor of leadership style and perceived leadership outcomes. Scores for each leadership scale across the four rating levels (leaders, supervisors, peers and followers) were aggregated with the exception of the management-by-exception active scale of transactional leadership which had an inadequate level of interrater agreement. In the descriptive and measurement component of the Main Study, the instruments were found to demonstrate adequate discriminant validity. The impact of role and gender on leadership style and EI were also examined, and females were found to be more transformational as leaders than males. Females also engaged in more contingent reward (transactional leadership) behaviours than males, whilst males engaged in more passive/avoidant leadership behaviours than females. In the inferential component of the Main Study, multiple regression procedures were used to examine the usefulness of EI as a predictor of leadership style and perceived leadership outcomes. None of the EI branches were found to be related to transformational leadership or the perceived leadership outcomes variables included in the study. Openness, emotional stability (the inverse of neuroticism) and general mental ability (inversely) each predicted a small amount of variance in transformational leadership. Passive/avoidant leadership was inversely predicted by the understanding emotions branch of EI. Overall, EI was not found to be a useful predictor of leadership style and leadership outcomes in the Main Study of this project. Implications for researchers and human resource practitioners are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Up to one-third of people affected by cancer experience ongoing psychological distress and would benefit from screening followed by an appropriate level of psychological intervention. This rarely occurs in routine clinical practice due to barriers such as lack of time and experience. This study investigated the feasibility of community-based telephone helpline operators screening callers affected by cancer for their level of distress using a brief screening tool (Distress Thermometer), and triaging to the appropriate level of care using a tiered model. Methods Consecutive cancer patients and carers who contacted the helpline from September-December 2006 (n = 341) were invited to participate. Routine screening and triage was conducted by helpline operators at this time. Additional socio-demographic and psychosocial adjustment data were collected by telephone interview by research staff following the initial call. Results The Distress Thermometer had good overall accuracy in detecting general psychosocial morbidity (Hospital Anxiety and Depression Scale cut-off score ≥ 15) for cancer patients (AUC = 0.73) and carers (AUC = 0.70). We found 73% of participants met the Distress Thermometer cut-off for distress caseness according to the Hospital Anxiety and Depression Scale (a score ≥ 4), and optimal sensitivity (83%, 77%) and specificity (51%, 48%) were obtained with cut-offs of ≥ 4 and ≥ 6 in the patient and carer groups respectively. Distress was significantly associated with the Hospital Anxiety and Depression Scale scores (total, as well as anxiety and depression subscales) and level of care in cancer patients, as well as with the Hospital Anxiety and Depression Scale anxiety subscale for carers. There was a trend for more highly distressed callers to be triaged to more intensive care, with patients with distress scores ≥ 4 more likely to receive extended or specialist care. Conclusions Our data suggest that it was feasible for community-based cancer helpline operators to screen callers for distress using a brief screening tool, the Distress Thermometer, and to triage callers to an appropriate level of care using a tiered model. The Distress Thermometer is a rapid and non-invasive alternative to longer psychometric instruments, and may provide part of the solution in ensuring distressed patients and carers affected by cancer are identified and supported appropriately.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this preliminary study was to determine the relevance of the categorization of the load regime data to assess the functional output and usage of the prosthesis of lower limb amputees. The objectives were a) to introduce a categorization of load regime, b) to present some descriptors of each activity, and c) to report the results for a case. The load applied on the osseointegrated fixation of one transfemoral amputee was recorded using a portable kinetic system for 5 hours. The periods of directional locomotion, localized locomotion, and stationary loading occurred 44%, 34%, and 22% of recording time and each accounted for 51%, 38%, and 12% of the duration of the periods of activity, respectively. The absolute maximum force during directional locomotion, localized locomotion, and stationary loading was 19%, 15%, and 8% of the body weight on the anteroposterior axis, 20%, 19%, and 12% on the mediolateral axis, and 121%, 106%, and 99% on the long axis. A total of 2,783 gait cycles were recorded. Approximately 10% more gait cycles and 50% more of the total impulse than conventional analyses were identified. The proposed categorization and apparatus have the potential to complement conventional instruments, particularly for difficult cases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Australian efforts to provide orthopaedic surgeons with living, load-bearing scaffolds suitable for current joint (knee and hip) replacement surgery, non-union fracture repair, and miniscal and growth plate cartilage regeneration are being lead by teams at the Institute for Medical and Veterinary Science and Women's and Children's Hospital in Adelaide; the Peter MacCallum and St Vincent's Medical Research Institutes in Melbourne; and the Mater Medical Research Institute and new Institute for Health and Biomedical Innovation at QUT, Brisbane. In each case multidisciplinary teams are attempting to develop autologous living tissue constructs, utilising mesenchymal stem cells (MSC), with the intention of effecting seamless repair and regeneration of skeletal trauma and defects. In this article we will briefly review current knowledge of the phenotypic properties of MSC and discuss the potential therapeutic applications of these cells as exemplified by their use in cartilage repair and tissue engineering based approaches to the treatment of skeletal defects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: To compare the intraocular pressure readings obtained with the iCare rebound tonometer and the 7CR non-contact tonometer with those measured by Goldmann applanation tonometry in treated glaucoma patients. Design: A prospective, cross sectional study was conducted in a private tertiary glaucoma clinic. Participants: 109 (54M:55F) patients including only eyes under medical treatment for glaucoma. Methods: Measurement by Goldmann applanation tonometry, iCare rebound tonometry and 7CR non-contact tonometry. Main Outcome Measures: Intraocular pressure. Results: There were strong correlations between the intraocular pressure measurements obtained with Goldmann and both the rebound and non-contact tonometers (Spearman r values ≥ 0.79, p < 0.001). However, there were small, statistically significant differences between the average readings for each tonometer. For the rebound tonometer, the mean intraocular pressure was slightly higher compared to the Goldmann applanation tonometer in the right eyes (p = 0.02), and similar in the left eyes (p = 0.93) however these differences did not reach statistical significance. The Goldmann correlated measurements from the noncontact tonometer were lower than the average Goldmann reading for both right (p < 0.001) and left (p > 0.01) eyes. The corneal compensated measurements from the non-contact tonometer were significantly higher compared to the other tonometers (p ≤ 0.001). Conclusions: The iCare rebound tonometer and the 7CR non-contact tonometer measure IOP in fundamentally different ways to the Goldmann applanation tonometer. The resulting IOP values vary between the instruments and will need to be considered when comparing clinical versus home acquired measurements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In recent years, the effect of ions and ultrafine particles on ambient air quality and human health has been well documented, however, knowledge about their sources, concentrations and interactions within different types of urban environments remains limited. This thesis presents the results of numerous field studies aimed at quantifying variations in ion concentration with distance from the source, as well as identifying the dynamics of the particle ionisation processes which lead to the formation of charged particles in the air. In order to select the most appropriate measurement instruments and locations for the studies, a literature review was also conducted on studies that reported ion and ultrafine particle emissions from different sources in a typical urban environment. The initial study involved laboratory experiments on the attachment of ions to aerosols, so as to gain a better understanding of the interaction between ions and particles. This study determined the efficiency of corona ions at charging and removing particles from the air, as a function of different particle number and ion concentrations. The results showed that particle number loss was directly proportional to particle charge concentration, and that higher small ion concentrations led to higher particle deposition rates in all size ranges investigated. Nanoparticles were also observed to decrease with increasing particle charge concentration, due to their higher Brownian mobility and subsequent attachment to charged particles. Given that corona discharge from high voltage powerlines is considered one of the major ion sources in urban areas, a detailed study was then conducted under three parallel overhead powerlines, with a steady wind blowing in a perpendicular direction to the lines. The results showed that large sections of the lines did not produce any corona at all, while strong positive emissions were observed from discrete components such as a particular set of spacers on one of the lines. Measurements were also conducted at eight upwind and downwind points perpendicular to the powerlines, spanning a total distance of about 160m. The maximum positive small and large ion concentrations, and DC electric field were observed at a point 20 m downwind from the lines, with median values of 4.4×103 cm-3, 1.3×103 cm-3 and 530 V m-1, respectively. It was estimated that, at this point, less than 7% of the total number of particles was charged. The electrical parameters decreased steadily with increasing downwind distance from the lines but remained significantly higher than background levels at the limit of the measurements. Moreover, vehicles are one of the most prevalent ion and particle emitting sources in urban environments, and therefore, experiments were also conducted behind a motor vehicle exhaust pipe and near busy motorways, with the aim of quantifying small ion and particle charge concentration, as well as their distribution as a function of distance from the source. The study found that approximately equal numbers of positive and negative ions were observed in the vehicle exhaust plume, as well as near motorways, of which heavy duty vehicles were believed to be the main contributor. In addition, cluster ion concentration was observed to decrease rapidly within the first 10-15 m from the road and ion-ion recombination and ion-aerosol attachment were the most likely cause of ion depletion, rather than dilution and turbulence related processes. In addition to the above-mentioned dominant ion sources, other sources also exist within urban environments where intensive human activities take place. In this part of the study, airborne concentrations of small ions, particles and net particle charge were measured at 32 different outdoor sites in and around Brisbane, Australia, which were classified into seven different groups as follows: park, woodland, city centre, residential, freeway, powerlines and power substation. Whilst the study confirmed that powerlines, power substations and freeways were the main ion sources in an urban environment, it also suggested that not all powerlines emitted ions, only those with discrete corona discharge points. In addition to the main ion sources, higher ion concentrations were also observed environments affected by vehicle traffic and human activities, such as the city centre and residential areas. A considerable number of ions were also observed in a woodland area and it is still unclear if they were emitted directly from the trees, or if they originated from some other local source. Overall, it was found that different types of environments had different types of ion sources, which could be classified as unipolar or bipolar particle sources, as well as ion sources that co-exist with particle sources. In general, fewer small ions were observed at sites with co-existing sources, however particle charge was often higher due to the effect of ion-particle attachment. In summary, this study quantified ion concentrations in typical urban environments, identified major charge sources in urban areas, and determined the spatial dispersion of ions as a function of distance from the source, as well as their controlling factors. The study also presented ion-aerosol attachment efficiencies under high ion concentration conditions, both in the laboratory and in real outdoor environments. The outcomes of these studies addressed the aims of this work and advanced understanding of the charge status of aerosols in the urban environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Digital human modelling (DHM) has today matured from research into industrial application. In the automotive domain, DHM has become a commonly used tool in virtual prototyping and human-centred product design. While this generation of DHM supports the ergonomic evaluation of new vehicle design during early design stages of the product, by modelling anthropometry, posture, motion or predicting discomfort, the future of DHM will be dominated by CAE methods, realistic 3D design, and musculoskeletal and soft tissue modelling down to the micro-scale of molecular activity within single muscle fibres. As a driving force for DHM development, the automotive industry has traditionally used human models in the manufacturing sector (production ergonomics, e.g. assembly) and the engineering sector (product ergonomics, e.g. safety, packaging). In product ergonomics applications, DHM share many common characteristics, creating a unique subset of DHM. These models are optimised for a seated posture, interface to a vehicle seat through standardised methods and provide linkages to vehicle controls. As a tool, they need to interface with other analytic instruments and integrate into complex CAD/CAE environments. Important aspects of current DHM research are functional analysis, model integration and task simulation. Digital (virtual, analytic) prototypes or digital mock-ups (DMU) provide expanded support for testing and verification and consider task-dependent performance and motion. Beyond rigid body mechanics, soft tissue modelling is evolving to become standard in future DHM. When addressing advanced issues beyond the physical domain, for example anthropometry and biomechanics, modelling of human behaviours and skills is also integrated into DHM. Latest developments include a more comprehensive approach through implementing perceptual, cognitive and performance models, representing human behaviour on a non-physiologic level. Through integration of algorithms from the artificial intelligence domain, a vision of the virtual human is emerging.