1000 resultados para Víctor


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper is on variable-speed wind turbines with permanent magnet synchronous generator (PMSG). Three different drive train mass models and three different topologies for the power-electronic converters are considered. The three different topologies considered are respectively a matrix, a two-level and a multilevel converter. A novel control strategy, based on fractional-order controllers, is proposed for the wind turbines. Simulation results are presented to illustrate the behaviour of the wind turbines during a converter control malfunction, considering the fractional-order controllers. Finally, conclusions are duly drawn. Copyright (C) 2010 John Wiley & Sons, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVO: Comparar las características epidemiológicas y clínicas de la cardiopatía chagásica crónica con otras miocardiopatías dilatadas. MÉTODOS: Se incluyeron a 128 pacientes consecutivos en un hospital de espcialidad, de 1993 a 2003 con miocardiopatías dilatadas, donde 51 (40%) con anti Tripanosoma cruzi. Se recopiló información epidemiológica por entrevista directa, y datos clínicos en los servicios asistenciales. Se utilizaron la prueba de la Chi-cuadrado o prueba exacta de Fischer, prueba t de Student ó la prueba de U de Mann Whitney y análisis multivariado. RESULTADOS: Los pacientes con cardiopatía chagásica crónica, eran más viejos (55±10 años) que los pacientes con miocardiopatías (42±17 años), nacieron en zonas rurales (90% vs 68%), en viviendas precarias (75% vs 16%), con hacinamiento (45% vs 20%), convivencia con animales domésticos (71% vs 61%) y conocían al vector (73% vs 25%). Los trastornos del ritmo y de la conducción, así como la colocación de marcapaso definitivo fueron frecuentes en los pacientes con cardiopatía chagásica crónica (84% vs 55%, 78% vs 64% Y 24% vs 10% respectivamente). La insuficiencia cardiaca congestiva venosa fue más frecuente en los pacientes con miocardiopatía seronegativa (88% vs 71%) y la perfusión miocárdic anormal con arterias epicárdicas normales fue igual en ambos grupos. Con respecto a co-morbilidad, los pacientes con cardiopatía chagásica crónica tenían sólo dos padecimientos, mientras que en el otro grupo era más amplia. CONCLUSIÓNES: La enfermedad de Chagas causa la miocardiopatía dilatada específica más común. Debido a su distribución regional en la República Mexicana, merece atención y se recomienda a nivel público adoptar medidas de prevención que ya probaron eficacia en otros países.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pela primeira vez é registrada a ocorrência de Aedes (Stegomyia) albopictus em área urbana da cidade de Fortaleza, no Estado do Ceará, Brasil. De janeiro a julho de 2005 foram utilizadas ovitrampas para a coleta de ovos de Aedes spp., os quais foram mantidos em laboratório para desenvolvimento até a fase adulta. Os mosquitos resultantes foram identificados e submetidos a testes para o isolamento dos vírus da dengue. Foram identificados 13 espécimes de Aedes albopictus, todos fêmeas. Não foi isolado vírus da dengue em nenhum dos pools de mosquitos. Apesar de o Aedes albopictus não ter sido incriminado por surtos de dengue no Brasil, não se pode descartar a possibilidade da transmissão dos vírus da dengue por tais mosquitos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, we present a comparison of richness patterns and floristic similarity for bryophytes in the five most important altitudinal habitat types in the Macaronesian islands. We evaluate the importance of different factors discussed in the literature in predicting species diversity applying the traditional island approach and within the framework of the new habitat approach, including area, isolation, climatic factors, geological age and human influence. From the analysis of patterns of bryophyte species distribution for selected habitats across islands and archipelagos, we specifically test the hypothesis that (i) floristic similarity is primarily determined by climatic factors, but not by geographical distance due to high dispersal ability in this species group and (ii) bryophyte richness is best predicted by area, but not by geological age of the habitat due to very low endemicity or speciation rate and high colonization rate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper focus on a demand response model analysis in a smart grid context considering a contingency scenario. A fuzzy clustering technique is applied on the developed demand response model and an analysis is performed for the contingency scenario. Model considerations and architecture are described. The demand response developed model aims to support consumers decisions regarding their consumption needs and possible economic benefits.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a comparison between proportional integral control approaches for variable speed wind turbines. Integer and fractional-order controllers are designed using linearized wind turbine model whilst fuzzy controller also takes into account system nonlinearities. These controllers operate in the full load region and the main objective is to extract maximum power from the wind turbine while ensuring the performance and reliability required to be integrated into an electric grid. The main contribution focuses on the use of fractional-order proportional integral (FOPI) controller which benefits from the introduction of one more tuning parameter, the integral fractional-order, taking advantage over integer order proportional integral (PI) controller. A comparison between proposed control approaches for the variable speed wind turbines is presented using a wind turbine benchmark model in the Matlab/Simulink environment. Results show that FOPI has improved system performance when compared with classical PI and fuzzy PI controller outperforms the integer and fractional-order control due to its capability to deal with system nonlinearities and uncertainties. © 2014 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper is about a hierarchical structure with an event-based supervisor in a higher level and a fractional-order proportional integral (FOPI) in a lower level applied to a wind turbine. The event-based supervisor analyzes the operation conditions to determine the state of the wind turbine. This controller operate in the full load region and the main objective is to capture maximum power generation while ensuring the performance and reliability required for a wind turbine to be integrated into an electric grid. The main contribution focus on the use of fractional-order proportional integral controller which benefits from the introduction of one more tuning parameter, the integral fractional-order, taking advantage over integer order proportional integral (PI) controller. Comparisons between fractional-order pitch control and a default proportional integral pitch controller applied to a wind turbine benchmark are given and simulation results by Matlab/Simulink are shown in order to prove the effectiveness of the proposed approach.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper focuses on a novel formalization for assessing the five parameter modeling of a photovoltaic cell. An optimization procedure is used as a feasibility problem to find the parameters tuned at the open circuit, maximum power, and short circuit points in order to assess the data needed for plotting the I-V curve. A comparison with experimental results is presented for two monocrystalline PV modules.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new integrated mathematical model for the simulation of offshore wind energy conversion system performance is presented in this paper. The mathematical model considers an offshore variable-speed turbine in deep water equipped with a permanent magnet synchronous generator using full-power two-level converter, converting the energy of a variable frequency source in injected energy into the electric network with constant frequency, through a high voltage DC transmission submarine cable. The mathematical model for the drive train is a concentrate two mass model which incorporates the dynamic for the structure and tower due to the need to emulate the effects of the moving surface. Controller strategy considered is a proportional integral one. Also, pulse width modulation using space vector modulation supplemented with sliding mode is used for trigger the transistor of the converter. Finally, a case study is presented to access the system performance. © 2014 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper proposes a stochastic mixed-integer linear approach to deal with a short-term unit commitment problem with uncertainty on a deregulated electricity market that includes day-ahead bidding and bilateral contracts. The proposed approach considers the typically operation constraints on the thermal units and a spinning reserve. The uncertainty is due to the electricity prices, which are modeled by a scenario set, allowing an acceptable computation. Moreover, emission allowances are considered in a manner to allow for the consideration of environmental constraints. A case study to illustrate the usefulness of the proposed approach is presented and an assessment of the cost for the spinning reserve is obtained by a comparison between the situation with and without spinning reserve.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper is on the maximization of total profit in a day-ahead market for a price-taker producer needing a short-term scheduling for wind power plants coordination with concentrated solar power plants, having thermal energy storage systems. The optimization approach proposed for the maximization of profit is a mixed-integer linear programming problem. The approach considers not only transmission grid constraints, but also technical operating constraints on both wind and concentrated solar power plants. Then, an improved short-term scheduling coordination is provided due to the more accurate modelling presented in this paper. Computer simulation results based on data for the Iberian wind and concentrated solar power plants illustrate the coordination benefits and show the effectiveness of the approach.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As it is well known, competitive electricity markets require new computing tools for generation companies to enhance the management of its resources. The economic value of the water stored in a power system reservoir is crucial information for enhancing the management of the reservoirs. This paper proposes a practical deterministic approach for computing the short-term economic value of the water stored in a power system reservoir, emphasizing the need to considerer water stored as a scarce resource with a short-term economic value. The paper addresses a problem concerning reservoirs with small storage capacities, i.e., the reservoirs considered as head-sensitivity. More precisely, the respective hydro plant is head-dependent and a pure linear approach is unable to capture such consideration. The paper presents a case study supported by the proposed practical deterministic approach and applied on a real multi-reservoir power system with three cascaded reservoirs, considering as input data forecasts for the electric energy price and for the natural inflow into the reservoirs over the schedule time horizon. The paper presents various water schedules due to different final stored water volume conditions on the reservoirs. Also, it presents the respective economic value of the water for the reservoirs at different stored water volume conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a systemic modeling for a PV system integrated into an electric grid. The modeling includes models for a DC-DC boost converter and a DC-AC two-level inverter. Classical or fuzzy PI controllers with pulse width modulation by space vector modulation associated with sliding mode control is used for controlling the PV system and power factor control is introduced at the output of the system. Comprehensive performance simulation studies are carried out with the modeling of the DC-DC boost converter followed by a two-level power inverter in order to compare the performance with the experimental results obtained during in situ operation with three commercial inverters. Also, studies are carried out to assess the quality of the energy injected into the electric grid in terms of harmonic distortion. Finally, conclusions regarding the integration of the PV system into the electric grid are presented. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper deals with the computing simulation of the impact on permanent magnet synchronous generator wind turbines due to fifth harmonic content and grid voltage decrease. Power converter topologies considered in the simulations are the two-level and the three-level ones. The three-level converters are limited by unbalance voltages in the DC-link capacitors. In order to lessen this limitation, a new control strategy for the selection of the output voltage vectors is proposed. Controller strategies considered in the simulation are respectively based on proportional integral and fractional-order controllers. Finally, a comparison between the results of the simulations with the two controller strategies is presented in order to show the main advantage of the proposed strategy. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper is about a hierarchical structure with an event-based supervisor in a higher level and a fractional-order proportional integral (FOPI) in a lower level applied to a wind turbine. The event-based supervisor analyzes the operation conditions to determine the state of the wind turbine. This controller operate in the full load region and the main objective is to capture maximum power generation while ensuring the performance and reliability required for a wind turbine to be integrated into an electric grid. The main contribution focus on the use of fractional-order proportional integral controller which benefits from the introduction of one more tuning parameter, the integral fractional-order, taking advantage over integer order proportional integral (PI) controller. Comparisons between fractional-order pitch control and a default proportional integral pitch controller applied to a wind turbine benchmark are given and simulation results by Matlab/Simulink are shown in order to prove the effectiveness of the proposed approach.