960 resultados para Triple Jet


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Additions of lactams, imides, (S)-4-benzyl-1,3-oxazolidin-2-one, 2-pyridone, pyrimidine-2,4-diones (AZT derivatives), or inosines to the electron-deficient triple bonds of methyl propynoate, tert-butyl propynoate, 3-butyn-2-one, N-propynoylmorpholine, or N-methoxy-N-methylpropynamide in the presence of many potential catalysts were examined. DABCO and, second, DMAP appeared to be the best (highest reaction rates and E/Z ratios), while RuCl3, RuClCp*(PPh3)2, AuCl, AuCl(PPh3), CuI, and Cu2(OTf)2 were incapable of catalyzing such additions. The groups incorporated (for example, the 2-(methoxycarbonyl)ethenyl group that we name MocVinyl) serve as protecting groups for the above-mentioned heterocyclic CONH or CONHCO moieties. Deprotections were accomplished via exchange with good nucleophiles: the 1-dodecanethiolate anion turned out to be the most general and efficient reagent, but in some particular cases other nucleophiles also worked (e.g., MocVinyl-inosines can be cleaved with succinimide anion). Some structural and mechanistic details have been accounted for with the help of DFT and MP2 calculations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An attorney representing seven property owners in Lowell, Iowa, requested the Iowa Department of Public Health (IDPH) Hazardous Waste Site Health Assessment Program to perform a health consultation for the Jet Gas Spill Site. The attorney asked the IDPH to provide comments concerning the potential and likely health effects to her clients due to exposure from the spill. The specific issues to be addressed are listed in this health consultation. The information in this health consultation was current at the time of writing. Data that emerges later could alter this document’s conclusions and recommendations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Polochic-Motagua fault systems (PMFS) are part of the sinistral transform boundary between the North American and Caribbean plates. To the west, these systems interact with the subduction zone of the Cocos plate, forming a subduction-subduction-transform triple junction. The North American plate moves westward relative to the Caribbean plate. This movement does not affect the geometry of the subducted Cocos plate, which implies that deformation is accommodated entirely in the two overriding plates. Structural data, fault kinematic analysis, and geomorphic observations provide new elements that help to understand the late Cenozoic evolution of this triple junction. In the Miocene, extension and shortening occurred south and north of the Motagua fault, respectively. This strain regime migrated northward to the Polochic fault after the late Miocene. This shift is interpreted as a ``pull-up'' of North American blocks into the Caribbean realm. To the west, the PMFS interact with a trench-parallel fault zone that links the Tonala fault to the Jalpatagua fault. These faults bound a fore-arc sliver that is shared by the two overriding plates. We propose that the dextral Jalpatagua fault merges with the sinistral PMFS, leaving behind a suturing structure, the Tonala fault. This tectonic ``zipper'' allows the migration of the triple junction. As a result, the fore-arc sliver comes into contact with the North American plate and helps to maintain a linear subduction zone along the trailing edge of the Caribbean plate. All these processes currently make the triple junction increasingly diffuse as it propagates eastward and inland within both overriding plates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The rotational speed of high-speed electric machines is over 15 000 rpm. These machines are compact in size when compared to the power rate. As a consequence, the heat fluxes are at a high level and the adequacy of cooling becomes an important design criterion. In the high-speed machines, the air gap between the stator and rotor is a narrow flow channel. The cooling air is produced with a fan and the flow is then directed to the air gap. The flow in the gap does not provide sufficient cooling for the stator end windings, and therefore additional cooling is required. This study investigates the heat transfer and flow fields around the coil end windings when cooling jets are used. As a result, an innovative and new assembly is introduced for the cooling jets, with the benefits of a reduced amount of hot spots, a lower pressure drop, and hence a lower power need for the cooling fan. The gained information can also be applied to improve the cooling of electric machines through geometry modifications. The objective of the research is to determine the locations of the hot spots and to find out induced pressure losses with different jet alternatives. Several possibilities to arrange the extra cooling are considered. In the suggested approach cooling is provided by using a row of air jets. The air jets have three main tasks: to cool the coils effectively by direct impingement jets, to increase and cool down the flow that enters the coil end space through the air gap, and to ensure the correct distribution of the flow by forming an air curtain with additional jets. One important aim of this study is the arrangement of cooling jets in such manner that hot spots can be avoided to wide extent. This enables higher power density in high-speed motors. This cooling system can also be applied to the ordinary electric machines when efficient cooling is needed. The numerical calculations have been performed using a commercial Computational Fluid Dynamics software. Two geometries have been generated: cylindrical for the studied machine and Cartesian for the experimental model. The main parameters include the positions, arrangements and number of jets, the jet diameters, and the jet velocities. The investigated cases have been tested with two widely used turbulence models and using a computational grid of over 500 000 cells. The experimental tests have been made by using a simplified model for the end winding space with cooling jets. In the experiments, an emphasis has been given to flow visualisation. The computational analysis shows good agreement with the experimental results. Modelling of the cooling jet arrangement enables also a better understanding of the complex system of heat transfer at end winding space.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Additions of lactams, imides, (S)-4-benzyl-1,3-oxazolidin-2-one, 2-pyridone, pyrimidine-2,4-diones (AZT derivatives), or inosines to the electron-deficient triple bonds of methyl propynoate, tert-butyl propynoate, 3-butyn-2-one, N-propynoylmorpholine, or N-methoxy-N-methylpropynamide in the presence of many potential catalysts were examined. DABCO and, second, DMAP appeared to be the best (highest reaction rates and E/Z ratios), while RuCl3, RuClCp*(PPh3)2, AuCl, AuCl(PPh3), CuI, and Cu2(OTf)2 were incapable of catalyzing such additions. The groups incorporated (for example, the 2-(methoxycarbonyl)ethenyl group that we name MocVinyl) serve as protecting groups for the above-mentioned heterocyclic CONH or CONHCO moieties. Deprotections were accomplished via exchange with good nucleophiles: the 1-dodecanethiolate anion turned out to be the most general and efficient reagent, but in some particular cases other nucleophiles also worked (e.g., MocVinyl-inosines can be cleaved with succinimide anion). Some structural and mechanistic details have been accounted for with the help of DFT and MP2 calculations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE This prospective multicenter phase III study compared the efficacy and safety of a triple combination (bortezomib-thalidomide-dexamethasone [VTD]) versus a dual combination (thalidomide-dexamethasone [TD]) in patients with multiple myeloma (MM) progressing or relapsing after autologous stem-cell transplantation (ASCT). PATIENTS AND METHODS Overall, 269 patients were randomly assigned to receive bortezomib (1.3 mg/m(2) intravenous bolus) or no bortezomib for 1 year, in combination with thalidomide (200 mg per day orally) and dexamethasone (40 mg orally once a day on 4 days once every 3 weeks). Bortezomib was administered on days 1, 4, 8, and 11 with a 10-day rest period (day 12 to day 21) for eight cycles (6 months), and then on days 1, 8, 15, and 22 with a 20-day rest period (day 23 to day 42) for four cycles (6 months). Results Median time to progression (primary end point) was significantly longer with VTD than TD (19.5 v 13.8 months; hazard ratio, 0.59; 95% CI, 0.44 to 0.80; P = .001), the complete response plus near-complete response rate was higher (45% v 25%; P = .001), and the median duration of response was longer (17.2 v 13.4 months; P = .03). The 24-month survival rate was in favor of VTD (71% v 65%; P = .093). Grade 3 peripheral neuropathy was more frequent with VTD (29% v 12%; P = .001) as were the rates of grades 3 and 4 infection and thrombocytopenia. CONCLUSION VTD was more effective than TD in the treatment of patients with MM with progressive or relapsing disease post-ASCT but was associated with a higher incidence of grade 3 neurotoxicity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present paper is devoted to the results of experimental research undertaken into photocatalytical oxidation (PCO) of aqueous solutions of de-icing agents and aqueous extract of jet fuel. The report consists of introduction, literature review, description of materials and methods, discussion of results and conclusions. TiO2 was selected as a photocatalyst for the experiments with synthetic solutions of ethylene glycol, 2-ethoxyethanol and aqueous extract of jet fuel. To explain the PCO mechanisms affecting certain behaviour of de-icing agent under distinctive conditions, the following factors were studied: the impact of initial concentration of pollutant, the role of pH, the presence of tert-butanol as OH·-radicals scavenger and mineral admixtures. PCO under solar radiation performed in two ways: catalysed by irradiated TiO2 slurry or by TiO2 attached to buoyant hollow glass micro-spheres. Special attention was paid to the energy-saving PCO with reduced intensity mixing of the slurry. The effect of PCO was assessed by determination of residual chemical oxygen demand of solution (COD) and by measuring of concentration of glycols. The PCO process efficiency was assumed to be dependent on the TiO2 suspension fractional composition. Thus, the following effects of solutions’ media were viewed: presence of organic admixtures, pH influence, mixing mode during the PCO. The effects of mineral admixtures - Ca2+, Fe3+/2+, Mn2+, SO42- - that are often present in natural and wastewater systems or produced during the degradation of organic pollutants and which can affect the rate of PCO of de-icing agents, were also investigated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Suihku/viira-nopeussuhde on perälaatikon huulisuihkun ja viiran välinen nopeusero. Se vaikuttaa suuresti paperin ja kartongin loppuominaisuuksiin, kuten formaatioon sekä kuituorientaatioon ja näin ollen paperin lujuusominaisuuksiin. Tämän johdosta on erityisen tärkeää tietää todellinen suihku/viira-nopeussuhde paperin- ja kartonginvalmistuksessa. Perinteinen suihku/viira-nopeussuhteen määritysmenetelmä perustuu perälaatikon kokonaispaineeseen. Tällä menetelmällä kuitenkin todellinen huulisuihkun nopeus saattaa usein jäädä tietämättä johtuen mahdollisesta virheellisestä painemittarin kalibroinnista sekä laskuyhtälön epätarkkuuksista. Tämän johdosta on kehitetty useita reaaliaikaisia huulisuihkun mittausmenetelmiä. Perälaatikon parametrien optimaaliset asetukset ovat mahdollista määrittää ja ylläpitää huulisuihkun nopeuden “on-line” määrityksellä. Perälaatikon parametrejä ovat mm. huulisuihku, huuliaukon korkeusprofiili, reunavirtaukset ja syöttövirtauksen tasaisuus. Huulisuihkun nopeuden on-line mittauksella paljastuu myös muita perälaatikon ongelmakohtia, kuten mekaaniset viat, joita on perinteisesti tutkittu aikaa vievillä paperin ja kartongin lopputuoteanalyyseillä.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The aims of the study were to evaluate the prevalence of acute coronary syndrome (ACS) among patients presenting with atypical chest pain who are evaluated for acute aortic syndrome (AAS) or pulmonary embolism (PE) with computed tomoangiography (CTA) and discuss the rationale for the use of triple rule-out (TRO) protocol for triaging these patients. METHODS: This study is a retrospective analysis of patients presenting with atypical chest pain and evaluated with thoracic (CTA), for suspicion of AAS/PE. Two physicians reviewed patient files for demographic characteristics, initial CT and final clinical diagnosis. Patients were classified according to CTA finding into AAS, PE and other diagnoses and according to final clinical diagnosis into AAS, PE, ACS and other diagnoses. RESULTS: Four hundred and sixty-seven patients were evaluated: 396 (84.8%) patients for clinical suspicion of PE and 71 (15.2%) patients for suspicion of AAS. The prevalence of ACS and AAS was low among the PE patients: 5.5% and 0.5% respectively (P = 0.0001), while the prevalence of ACS and PE was 18.3% and 5.6% among AAS patients (P = 0.14 and P = 0.34 respectively). CONCLUSION: The prevalence of ACS and AAS among patients suspected clinically of having PE is limited while the prevalence of ACS and PE among patients suspected clinically of having AAS is significant. Accordingly patients suspected for PE could be evaluated with dedicated PE CTA while those suspected for AAS should still be triaged using TRO protocol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Context.Massive stars form in dense and massive molecular cores. The exact formation mechanism is unclear, but it is possible that some massive stars are formed by processes similar to those that produce the low-mass stars, with accretion/ejection phenomena occurring at some point of the evolution of the protostar. This picture seems to be supported by the detection of a collimated stellar wind emanating from the massive protostar IRAS 16547-4247. A triple radio source is associated with the protostar: a compact core and two radio lobes. The emission of the southern lobe is clearly non-thermal. Such emission is interpreted as synchrotron radiation produced by relativistic electrons locally accelerated at the termination point of a thermal jet. Since the ambient medium is determined by the properties of the molecular cloud in which the whole system is embedded, we can expect high densities of particles and infrared photons. Because of the confirmed presence of relativistic electrons, inverse Compton and relativistic Bremsstrahlung interactions are unavoidable. Aims.We aim to make quantitative predictions of the spectral energy distribution of the non-thermal spots generated by massive young stellar objects, with emphasis on the particular case of IRAS 16547-4247. Methods.We study the high-energy emission generated by the relativistic electrons which produce the non-thermal radio source in IRAS 16547-4247. We also study the result of proton acceleration at the terminal shock of the thermal jet and make estimates of the secondary gamma rays and electron-positron pairs produced by pion decay. Results.We present spectral energy distributions for the southern lobe of IRAS 16547-4247, for a variety of conditions. We show that high-energy emission might be detectable from this object in the gamma-ray domain. The source may also be detectable in X-rays through long exposures with current X-ray instruments. Conclusions.Gamma-ray telescopes such as GLAST, and even ground-based Cherenkov arrays of new generation can be used to study non-thermal processes occurring during the formation of massive stars.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The efficacy of first-generation protease inhibitor based triple-therapy against hepatitis C virus (HCV) infection is limited in HIV/HCV-coinfected patients with advanced liver fibrosis and non-response to previous peginterferon-ribavirin. These patients have a low chance of achieving a sustained virologic response (SVR) using first generation triple-therapy, with a success rate of only 20%. We investigated the efficacy and safety of lead-in therapy with intravenous silibinin followed by triple-therapy in this difficult-to-treat patient group. METHODOLOGY: Inclusion criteria were HIV/HCV coinfection with advanced liver fibrosis and documented previous treatment failure on peginterferon-ribavirin. The intervention was a lead-in therapy with intravenous silibinin 20 mg/kg/day for 14 days, followed by triple-therapy (peginterferon-ribavirin and telaprevir) for 12 weeks, and peginterferon-ribavirin alone for 36 weeks. Outcome measurements were HCV-RNA after silibinin lead-in and during triple-therapy, SVR data at week 12, and safety and tolerability of silibinin. RESULTS: We examined sixteen HIV/HCV-coinfected patients with previous peginterferon-ribavirin failure, of whom 14 had a fibrosis grade METAVIR ≥F3. All were on successful antiretroviral therapy. Median (IQR) HCV-RNA decline after silibinin therapy was 2.65 (2.1-2.8) log10 copies/mL. Fifteen of sixteen patients (94%) had undetectable HCV RNA at weeks 4 and 12, eleven patients (69%) showed end-of-treatment response (i.e., undetectable HCV-RNA at week 48), and ten patients (63%) reached SVR at week 12 (SVR 12). Six of the sixteen patients (37%) did not reach SVR 12: One patient had rapid virologic response (RVR) (i.e., undetectable HCV-RNA at week 4) but stopped treatment at week 8 due to major depression. Five patients had RVR, but experienced viral breakthroughs at week 21, 22, 25, or 32, or a relapse at week 52. The HIV RNA remained below the limit of detection in all patients during the complete treatment period. No serious adverse events and no significant drug-drug interactions were associated with silibinin. CONCLUSION: A lead-in with silibinin before triple-therapy was safe and highly effective in difficult-to-treat HIV/HCV coinfected patients, with a pronounced HCV-RNA decline during the lead-in phase, which translates into 63% SVR. An add-on of intravenous silibinin to standard of care HCV treatment is worth further exploration in selected difficult-to-treat patients. TRIAL REGISTRATION: ClinicalTrials.gov NCT01816490.