910 resultados para Trammel net, small-scale fishery, discards, Mediterranean sea


Relevância:

100.00% 100.00%

Publicador:

Resumo:

To properly describe the interactions between the ocean and atmosphere, it is necessary to assess a variety of time and spatial scales phenomena. Here, high resolution oceanographic and meteorological data collected during an observational campaign carried out aboard a ship in the tropical Atlantic Ocean, on May 15-24, 2002, is used to describe the radiation balance at the ocean interface. Data collected by two PIRATA buoys, along the equator at 23°W and 35°W and satellite and climate data are compared with the data obtained during the observational campaign. Comparison indicates remarkable similarity for daily and hourly values of radiation fluxes components as consequence of the temporal and spatial consistence presented by the air and water temperatures measured in situ and estimated from large scale information. The discrepancy, mainly in the Sao Pedro and Sao Paulo Archipelago area, seems to be associated to the local upwelling of cold water, which is not detected in all other estimates investigated here. More in situ data are necessary to clarify whether this upwelling flow has a larger scale effect and what are the meteorological and oceanographic implications of the local upwelling area on the tropical waters at the Brazilian coast.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, experimental results are reported for a small scale cogeneration plant for power and refrigeration purposes. The plant includes a natural gas microturbine and an ammonia/water absorption chiller fired by steam. The system was tested under different turbine loads, steam pressures and chiller outlet temperatures. An evaluation based on the 1st and 2nd Laws of Thermodynamics was also performed. For the ambient temperature around 24°C and microturbine at full load, the plant is able to provide 19 kW of saturated steam at 5.3 bar (161 °C), corresponding to 9.2 kW of refrigeration at -5 °C (COP = 0.44). From a 2nd law point-of-view, it was found that there is an optimal chiller outlet temperature that maximizes the chiller exergetic efficiency. As expected, the microturbine presented the highest irreversibilities, followed by the absorption chiller and the HRSG. In order to reduce the plant exergy destruction, it is recommended a new design for the HRSG and a new insulation for the exhaust pipe. © 2013 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Incluye Bibliografía

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Includes bibliography