162 resultados para Titanio
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Nanotubes have been subject of studies with regard to their ability to promote differentiation of several cells lines. Nanotubes have been used to increase the roughness of the implant surfaces and to improve bone tissue integration on dental implant. In this study TiO2 nanotube layer prepared by anodic oxidation was evaluated. Nanotube formation was carried out using Glycerol-H2O DI(50-50 v/v)+NH4F(0,5 a 1,5% and 10-30V) for 1-3 hours at 37ºC. After nanostructure formation the topography of surface was observed using field-emission-scanning-microscope (FE-SEM). Contact angle was evaluated on the anodized and non-anodized surfaces using a water contact angle goniometer in sessile drop mode with 5 μL drops. In the case of nanotube formation and no treatment surface were presented 39,1° and 75,9°, respectively. The contact angle describing the wettability of the surface is enhanced, more hydrophilic, on the nanotube surfaces, which can be advantageous for enhancing protein adsorption and cell adhesion.
Resumo:
Calvaria grafts provide good bone quantity for the reconstruction of the atrophic maxilla, and have lower morbidity and resorption rates when compared to iliac crest. The aim of this paper is to present the technique for obtaining a graft of the skull. Initially, the depth of the osteotomy is determined by a manually conducted bur, which establishes the limits of the structures of the skull (outer table, diploe and inner table), making the removal of bone blocks easier and safer. Thus, osteotomies of the blocks are made with greater security, avoiding the complications inherent to surgical technique. The case that will be presented it is from a male patient of 65 years who refused to submit to the iliac crest graft, opting for the calvaria, despite being bald, that is a contraindication for this treatment modality. A delicate suture associated with placement of titanium mesh to maintain the conformation of the patient's skull in the region of the bone defect, created after removal of the graft, provided a good cosmetic result at the donor site. The use of titanium mesh for re-anatomization of bone defects created in the grafts is well indicated for bald patients.
Resumo:
This study aims to evaluate the corrosion resistance of Ti-30Ta alloy when subjected to different strain rates. Samples of the alloy Ti-30Ta were obtained from the melting of pure elements in the arc furnace in inert atmosphere (argon gas). Then, the samples were subjected to a thermal treatment and to cold worked to obtain bars. After forging, the samples were machined in accordance with ASTME9-09 standard for carried out compression tests. To microstructural characterization, samples were sectioned longitudinal and transversally and embedded in resin. After, the wet sanding and polishing were performed, followed by a chemical attack, in order to study the microstructure under an optical microscope. Microhardness was measured on the samples that were subjected to microstructural characterization by using microhardness tester. Phases were evaluated by x-rays diffraction. Corrosion tests were carried out to evaluate the influence of deformation on the corrosion resistance. Results show that microstructure was not influenced by deformation
Resumo:
Surface treatments have been used to modify the surface of titanium alloys. The purpose of this study is to evaluate the surface of Ti-30Ta alloy after biomimetic approach associated to antibiotic incorporation. The ingots were obtained in arc melting furnace, treated and cold-worked by swaging. The surface treatment was performed in two steps: biomimetic treatment and antibiotic incorporation. For biomimetic treatment, first an alkaline treatment (NaOH 1M at 60ºC) was performed, followed by heat treatment and immersion in SBFx5 (Simulated Body Fluid) for a period of 24 hours. In order to incorporate the antibiotic, samples were immersed in a solution formed by drugs plus SBFx5 for 48 hours. The sample surfaces were analyzed by scanning electron microscopy (SEM), X-Ray diffraction (XRD), atomic force microscopy (AFM) and contact angle measurements. The release of antibiotic from coated implants was measured in phosphate buffer saline at pH 7.4 by using UV/VIS spectrometry. Results have shown changes on the surface after incorporating the drug, which is gradually co-precipitated with the Ca-P crystals, forming a uniform and rough layer on the metal surface
Resumo:
With advances in health care, has been na increase of demand for material that could replace the functions of the human body parts, thus evolved biomedic prosthesis which today are responsible for the constant improvement of the quality of life. The Titanium alloys are widely used as implants due to its properties, like high mechanical resistance, biocompatibility and corrosion resistance, and the addition alloying elements like Zirconium, may improve some of those properties. Such properties are related to the microstructure and consequently to the type of processing performed. The purpose of this dissertation was to characterize the experimental alloy Ti15Zr after route of processsing and heat treatment in order to extend the knowledge about this alloy. The latter has been abtained by fusion of pure metals in a arc melting furnace with an inert argon atmosphere. The material has been homogenized in a tube furnace at 950ºC for 24h and cold worked by swaging, after that, bars with 10 mm of diameter were obtained by the process of rotary forging. The samples were solubilized at 900º C for 2 hours and quenched in water. After that, 4 samples were submitted to the aging, at 400º C, 450º C, 500º C and 550º C. The microstructure and phase analysis was done by optical microscopy and X-rays diffraction (XRD), the mechanical characterization was carried out by microhardness test and finally, evaluation of corrosion resistance of the alloy by electrochemical tests. The XRD and the optical microscopy made it possible to analyze that the heat treatment influenced the phase shifting from α to α', and probably affected the alloy hardness, at the first aged sample at 500º Chas been a sudden increase in the value of hardness, probably by appearance of omega phase, unwanted phase to the medical application duo to great fragility, and finally ... (Complete abstract click electronic access below)
Resumo:
This study aims to evaluate the corrosion resistance of Ti-30Ta alloy when subjected to different strain rates. Samples of the alloy Ti-30Ta were obtained from the melting of pure elements in the arc furnace in inert atmosphere (argon gas). Then, the samples were subjected to a thermal treatment and to cold worked to obtain bars. After forging, the samples were machined in accordance with ASTME9-09 standard for carried out compression tests. To microstructural characterization, samples were sectioned longitudinal and transversally and embedded in resin. After, the wet sanding and polishing were performed, followed by a chemical attack, in order to study the microstructure under an optical microscope. Microhardness was measured on the samples that were subjected to microstructural characterization by using microhardness tester. Phases were evaluated by x-rays diffraction. Corrosion tests were carried out to evaluate the influence of deformation on the corrosion resistance. Results show that microstructure was not influenced by deformation
Resumo:
Surface treatments have been used to modify the surface of titanium alloys. The purpose of this study is to evaluate the surface of Ti-30Ta alloy after biomimetic approach associated to antibiotic incorporation. The ingots were obtained in arc melting furnace, treated and cold-worked by swaging. The surface treatment was performed in two steps: biomimetic treatment and antibiotic incorporation. For biomimetic treatment, first an alkaline treatment (NaOH 1M at 60ºC) was performed, followed by heat treatment and immersion in SBFx5 (Simulated Body Fluid) for a period of 24 hours. In order to incorporate the antibiotic, samples were immersed in a solution formed by drugs plus SBFx5 for 48 hours. The sample surfaces were analyzed by scanning electron microscopy (SEM), X-Ray diffraction (XRD), atomic force microscopy (AFM) and contact angle measurements. The release of antibiotic from coated implants was measured in phosphate buffer saline at pH 7.4 by using UV/VIS spectrometry. Results have shown changes on the surface after incorporating the drug, which is gradually co-precipitated with the Ca-P crystals, forming a uniform and rough layer on the metal surface
Resumo:
With advances in health care, has been na increase of demand for material that could replace the functions of the human body parts, thus evolved biomedic prosthesis which today are responsible for the constant improvement of the quality of life. The Titanium alloys are widely used as implants due to its properties, like high mechanical resistance, biocompatibility and corrosion resistance, and the addition alloying elements like Zirconium, may improve some of those properties. Such properties are related to the microstructure and consequently to the type of processing performed. The purpose of this dissertation was to characterize the experimental alloy Ti15Zr after route of processsing and heat treatment in order to extend the knowledge about this alloy. The latter has been abtained by fusion of pure metals in a arc melting furnace with an inert argon atmosphere. The material has been homogenized in a tube furnace at 950ºC for 24h and cold worked by swaging, after that, bars with 10 mm of diameter were obtained by the process of rotary forging. The samples were solubilized at 900º C for 2 hours and quenched in water. After that, 4 samples were submitted to the aging, at 400º C, 450º C, 500º C and 550º C. The microstructure and phase analysis was done by optical microscopy and X-rays diffraction (XRD), the mechanical characterization was carried out by microhardness test and finally, evaluation of corrosion resistance of the alloy by electrochemical tests. The XRD and the optical microscopy made it possible to analyze that the heat treatment influenced the phase shifting from α to α', and probably affected the alloy hardness, at the first aged sample at 500º Chas been a sudden increase in the value of hardness, probably by appearance of omega phase, unwanted phase to the medical application duo to great fragility, and finally ... (Complete abstract click electronic access below)
Resumo:
Oggigiorno si osserva a livello mondiale un continuo aumento dei consumi di acqua per uso domestico, agricolo ed industriale che dopo l’impiego viene scaricata nei corpi idrici (laghi, fiumi, torrenti, bacini, ecc) con caratteristiche chimico fisiche ed organolettiche completamente alterate, necessitando così di specifici trattamenti di depurazione. Ricerche relative a metodi di controllo della qualità dell’acqua e, soprattutto, a sistemi di purificazione rappresentano pertanto un problema di enorme importanza. I trattamenti tradizionali si sono dimostrati efficienti, ma sono metodi che operano normalmente trasferendo l’inquinante dalla fase acquosa contaminata ad un’altra fase, richiedendo perciò ulteriori processi di depurazione. Recentemente è stata dimostrata l’efficacia di sistemi nano strutturati come TiO2-Fe3O4 ottenuto via sol-gel, nella foto-catalisi di alcuni sistemi organici. Questo lavoro di tesi è rivolto alla sintesi e caratterizzazione di un catalizzatore nanostrutturato composito costituito da un core di Fe3O4 rivestito da un guscio di TiO2 separate da un interstrato inerte di SiO2, da utilizzare nella foto-catalisi di sistemi organici per la depurazione delle acque utilizzando un metodo di sintesi alternativo che prevede un “approccio” di tipo colloidale. Partendo da sospensioni colloidali dei diversi ossidi, presenti in commercio, si è condotta la fase di deposizione layer by layer via spray drying, sfruttando le diverse cariche superficiali dei reagenti. Questo nuovo procedimento permette di abbattere i costi, diminuire i tempi di lavoro ed evitare possibili alterazioni delle proprietà catalitiche della titania, risultando pertanto adatto ad una possibile applicazione su scala industriale. Tale sistema composito consente di coniugare le proprietà foto-catalitiche dell’ossido di titanio con le proprietà magnetiche degli ossidi di ferro permettendo il recupero del catalizzatore a fine processo. Il foto-catalizzatore è stato caratterizzato durante tutte la fasi di preparazione tramite microscopia SEM e TEM, XRF, Acusizer, spettroscopia Raman e misure magnetiche. L’attività foto-calitica è stata valutata con test preliminari utilizzando una molecola target tipo il rosso di metile in fase acquosa. I risultati ottenuti hanno dimostrato che il sistema core-shell presenta inalterate sia le proprietà magnetiche che quelle foto-catalitiche tipiche dei reagenti.
Resumo:
Le Dye – Sensitized Solar Cells (DSSC) sono attualmente considerate tra le alternative più promettenti al fotovoltaico tradizionale. I ridotti costi di produzione e l’elevata versatilità di utilizzo rappresentano i punti di forza di questi dispositivi innovativi. Ad oggi la ricerca è concentrata prevalentemente sull’incremento delle prestazioni delle DSSC, ottenibile solamente attraverso un miglioramento delle funzioni dei singoli componenti e dell’interazione sinergica tra questi. Tra i componenti, ha recentemente assunto particolare interesse il blocking layer (BL), costituito generalmente da un film sottile di TiO2 depositato sulla superficie dell’anodo (FTO) e in grado di ottimizzare i fenomeni all’interfaccia FTO/TiO2/elettrolita. Nel corso di questo lavoro di tesi si è rivolta l’attenzione prevalentemente sulle caratteristiche del BLs (ad esempio proprietà morfologico – strutturali) cercando di mettere in correlazione il processo di deposizione con le caratteristiche finali del film ottenuto. A questo scopo è stato ottimizzato un processo di deposizione dei film via spin coating, a partire da soluzioni acquosa o alcolica di precursore (TiCl4). I film ottenuti sono stati confrontati con quelli depositati tramite un processo di dip coating riportato in letteratura. I BLs sono stati quindi caratterizzati tramite microscopia (SEM – AFM), spettrofotometria (UV.- Vis) e misure elettrochimiche (CV – EIS). I risultati ottenuti hanno messo in evidenza come i rivestimenti ottenuti da soluzione acquosa di precursore, indipendentemente dalla tecnica di deposizione utilizzata (spin coating o dip coating) diano origine a film disomogenei e scarsamente riproducibili, pertanto non idonei per l’applicazione nelle DSSC. Viceversa, i BLs ottenuti via spin coating dalla soluzione alcolica di TiCl4 sono risultati riproducibili, omogenei, e uniformemente distribuiti sulla superficie di FTO. Infine, l’analisi EIS ha in particolare evidenziato un effettivo aumento della resistenza al trasferimento di carica tra elettrodo FTO ed elettrolita in presenza di questi BLs, fenomeno generalmente associato ad un efficace blocking effect.
Resumo:
Studio sulla ottimizzazione di placche mandibolari, utilizzate per ricostruzioni ossee, inclusivo di calcolo numerico, disegno ed analisi strutturali.
Resumo:
Il lavoro di questa tesi è incentrato sulla crescita e lo studio delle proprietà strutturali di sistemi nanostrutturati di titanio e ossido di titanio, prodotti mediante la tecnica della condensazione in gas inerte. Lo studio è finalizzato in particolare ad ottenere un materiale idoneo per la produzione di idrogeno tramite la foto-elettrolisi. Nel primo capitolo viene descritto a livello teorico il processo di scissione dell’acqua all’interno di celle foto-elettrochimiche, in cui viene impiegato il TiO2 (titania) come foto-anodo. Nel secondo capitolo viene introdotta la tecnica di crescita, viene descritta la macchina utilizzata illustrandone vantaggi e limitazioni. Inoltre viene fornita una descrizione teorica del tipo di crescita che avviene all’interno della camera di evaporazione. Allo scopo di comprendere meglio questi processi, vengono riportati nel capitolo 3 alcuni studi, basati su principi primi, riguardanti la stabilità di fase e le trasformazioni di fase per i tre principali polimorfi del TiO2. Nel capitolo 4 sono illustrate le tecniche impiegate per l’indagine strutturale: diffrazione e assorbimento di raggi X con relativa analisi dati, microscopia elettronica a scansione. Prima di misurare l’attività fotocatalitica dei campioni di nanoparticelle di titania, è necessario condurre delle misure di fotocorrente in una cella foto-elettrochimica, i risultati di queste analisi di tipo funzionale sono presentati nel capitolo 5. Nel capitolo 6 sono riportate le conclusioni del lavoro di tesi.
Resumo:
L’obbiettivo di una ricostruzione micro vascolare di mandibola è quello di assicurare al paziente il miglior risultato estetico e funzionale auspicabile. Ciò può essere conseguito utilizzando il lembo microvascolare di perone/cresta iliaca e una placca ricostruttiva in titanio che funga da guida nella fase di modellamento del lembo per ricreare un contorno parabolico il più possibile simile al profilo mandibolare originario del paziente. Il modellamento manuale ed artigianale intraoperatorio di una placca ricostruttiva è operatore dipendente ed anche in mani molto abili o ricorrendo a modelli anatomici stereolitografici non sempre risulta preciso quanto voluto e spesso non porta ai risultati postoperatori attesi e desiderati. Obbiettivo del nostro studio è stato pertanto, sfruttando le moderne tecnologie CAD-CAM, la produzione di placche ricostruttive “custom -made” progettate direttamente al computer ricreanti il profilo osseo originale del paziente.
Resumo:
Nella presente tesi ci si pone lo scopo di studiare stabilità, ciclabilità e cinetica di campioni composti da magnesio e titanio (Mg-Ti) prodotti con la tecnica della condensazione in gas inerte (IGC) per lo di stoccaggio di idrogeno. Il sistema Mg-Ti sembra essere un buon candidato per poter costruire serbatoi di idrogeno allo stato solido sia per applicazioni fisse che mobili. La ricerca di tecnologie efficaci per immagazzinare idrogeno è fondamentale per poter affermare un ciclo energetico sostenibile, svincolato dai combustibili fossili. Sia il lavoro di crescita dei campioni all'Università di Bologna, sia la caratterizzazione di questi nei laboratori dell' Institut de Chimie et des Materiaux Paris-Est (ICMPE) si collocano all'interno del progetto europeo COST per la ricerca di materiali nanostrutturati destinati ad applicazioni nel campo dello stoccaggio dell'energia in forma di idrogeno allo stato solido.