638 resultados para Titânio poroso


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Biopatologia Bucal - ICT

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the influence of the bed in High Density Porous Polyethylene (Medpor) implants integration. Two different kind of beds -- corticalized and decorticalized -- were made in six dogs. The animals were killed thirty, sixty and ninety days after implantation. Blocks including implant and adjacent bone were harvested, submitted to histological procedures, stained in hematoxiline-eosine and analyzed in optic microscope. The results demonstrated an absence of infection and foreign body reaction associated with High Density Porous Polyethylene (Medpor) implants. Furthermore, bony and fibrovascular ingrowth could be observed into its pores. The best integration was noted in decorticalized group, in which occurred a greater bony and fibrovascular ingrowth in comparison to the corticalized group

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Para a recuperação da estética facial,há necessidade de reposição do volume orbitário perdido em decorrência de eviscerações ou enucleações. Este estudo foi realizado com os objetivos de avaliar comparativamente a biocompatibilidade e a manutenção do volume orbitário com o uso de esferas de hidroxiapatita sintética e de polietileno poroso, na reconstrução de cavidades evisceradas de coelhos. Métodos: Para isso foram utilizados 56 coelhos albinos, submetidos à evisceração do olho direito, com colocação de esferas de hidroxiapatita sintética (G1 – 28 animais) ou polietileno poroso (G2 – 28 animais).Quatro coelhos de cada grupo foram sacrificados em 7 momentos experimentais: 7, 15, 30, 60, 90, 120 e 180 dias após a evisceração. Após o sacrifício, o conteúdo da cavidade orbitária direita foi removido e seccionado na porção central em duas hemi-metades,uma das quais foi preparada para exame histopatológico; exame ultra-estrutural em microscópio eletrônico de varredura foi feito em dois animais de 7, 60 e 180 dias, de ambos os grupos experimentais. Resumo 118 Resultados: Observou-se aos 7 dias, tecido conjuntivo frouxo, constituído de células inflamatórias e hemáceas, em meio à rede de fibrina, principalmente na periferia da esfera de hidroxiapatita e chegando até ao centro da esfera de polietileno; a reação tecidual tornou-se mais densa com o passar do tempo. Decorridos 60 dias, observou-se em G1, início de metaplasia óssea que se acentuou ao longo do experimento. Em todos os momentos experimentais, a inflamação,predominantemente macrofágica, foi muito mais acentuada em G1.O volume da cavidade esclero-corneana foi melhor mantido em G2. Conclusão: a esfera de hidroxiapatita sintética provoca mais inflamação que a de polietileno poroso e é menos eficiente na manutenção do volume orbitário... (Resumo completo, clicar acesso eletrônico abaixo)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atualmente o titânio é empregado como biomaterial devido à sua biocompatibilidade e resistência à corrosão. Entretanto, íons fluoretos, freqüentemente empregados em dentifrícios bucais, podem interferir no processo de corrosão. O objetivo deste estudo foi analisar a influência de um meio fluoretado com diferentes pH nas propriedades mecânicas e na resistência à corrosão dos conjuntos implantes/componentes protéticos à base de Ti c.p., a partir dos testes de fadiga, microscopia eletrônica de varredura (MEV) e dureza. Foram simulados cinco anos de uso regular de meios de higiene oral com conteúdo de 1500 ppm de NaF, com dois diferentes pH, 7,4 e 5,3, mediante imersão das amostras nesses meios durante 184 horas e também em água destilada, grupo controle. As amostras foram testadas num durômetro Micromet 2001 (500gf/30s). Os dados dos testes de dureza foram analisados pelo teste de Wilcoxon, demonstrando que as amostras sofreram influência negativa na dureza após a ação dos íons fluoreto. Entretanto, essa influência não ocorreu nos testes de fadiga realizados em uma máquina de ensaios mecânicos MTS-810, fixada a 100.000 ciclos, 15Hz e programada com força de fadiga a 150 N. Pela análise de MEV foram constatadas evidências de corrosão na superfície das amostras após ação de íons fluoretos, entretanto pelo EDS não se verificou incorporação de íons fluoretos sobre a superfície dos conjuntos. Concluiu-se que a concentração de flúor e o pH das soluções não exerceram influência nas propriedades mecânicas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O protetor solar é um produto extremamente importante para proteger a pele da radiação ultravioleta proveniente do sol e capaz de reduzir a incidência de câncer de pele. Os filtros solares são divididos em orgânicos e inorgânicos e, dentre os inorgânicos, se encontra o TiO2 que atua refletindo, espalhando e absorvendo as radiações UV, além de ser fotoestável e de baixo potencial de irritabilidade dérmica. Neste trabalho foram desenvolvidas formulações cosméticas em forma de gel contendo nanopartículas de dióxido de titânio capazes de agir como fotoprotetores físicos e que mantem a transparência ao serem aplicados sobre uma superfície, como a pele. Foram desenvolvidos xerogéis a base de nanopartículas de TiO2 com tamanho e superfície controlados. A partir dessas nanopartículas foi possível preparar formulações cosméticas contendo nanopartículas redispersas de xerogéis a base de TiO2. Esses sistemas foram avaliados por testes de citotoxicidade e foi obtido um resultado favorável para a continuidade da pesquisa, sugerindo o uso deste material em humanos sem causar danos. Foram feitas as caracterizações físico químicas e estruturais. A análise de FPS indicou amplo espectro da formulação, o potencial zeta mostrou que é possível evitar aglomerações das nanopartículas em pHs utilizados para formulações tópicas, a reologia demonstrou que as formulações apresentam comportamento de recuperação da consistência e organização do material inicial após seu desarranjo durante o cisalhamento. As caracterizações serviram para obter um conhecimento da estrutura química e física das amostras que contém as nanopartículas de dióxido de titânio, para que seja possível fazer uma análise crítica e melhor qualificar o protetor solar desenvolvido.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to complications caused by metallic implants in the replacement of bone tissue, the biological application of ceramics raised and became a viable alternative. The titania has the ability to promote bone tissue regeneration based on its structure, mechanical and biologically properties compatibility. The present work aims at obtaining and characterization of Titania (TiO2) porous ceramics produced by the polymeric sponge method (replica method). Polyurethane sponge with 10 ppi and 15 ppi (pores per linear inch) were used. The process differentiation is the air blower used to remove excess slurry. The ceramics sponges were dried in an oven, then pre-sintered at 1000 o C and sintered at 1450 o C. The effect of direct sintering at 1450 o C was also assessed. The percentage of solids used to prepare the slurry was 40 to 45% by weight. To increase the surface porosity of the sponge, 20% of starch was added. There was difficulty on controlling the thickness of the slurry layers on the sponge which resulted in the variation of samples mechanical resistance. Despite this, the results obtained are quite promising for the proposed use, indicating that it is possible to obtain titania sponges with an apparent porosity of around 60%, a bulk density ranging from 40 to 47% and a compressive strength resistance – that with better control of layers depositions – can vary from 1 to 4 MPa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this research was tested a finite element model (FEM) that represented the creep of a slab during the reheating process of hot rolling. The aim is to prevent creep phenomenon changing the reheating profile with hot tensile test in Gleeble 3500, and, also, understand the former defect crisis. The goal of this work is to have a predictive tool to optimize the reheating process changing parameters (length and thickness). Then, use input parameters obtained from the tests to approximate the solution of the problem aided by Abaqus CAE. The results have showed that the ferritic stainless steel AISI 409 has a lower sensitivity to creep comparing to the stainless steel AISI 409, AISI 430Ti, AISI 441 and AISI 444

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, the influence of modifications of the cp-Ti and Ti 6Al 4V alloy, by treating the surface with NaOH and depositing titanium oxide and hydroxyapatite by sol-gel method, on their biocompatibility was studied. The coatings were characterized by scanning electron microscopy and X-ray diffraction which showed that the coatings on Ti 6Al 4V are better than on cp-Ti. Adhesion tests showed that adhesion strength of the coatings on cp-Ti substrate is less than on Ti 6Al 4V as well as cytotoxicity for L929 fibroblast cells is higher

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A destruição da camada de ozônio resulta em um preocupante aumento na incidência de radiação ultravioleta (UV) na superfície da Terra, radiação esta, responsável pela ocorrência de danos na pele e pelo aparecimento do câncer de pele, tipo mais comum de câncer. Assim, neste trabalho foram desenvolvidos sistemas líquido-cristalinos multifuncionais contendo nanopartículas de dióxido de titânio, cuja propriedade fotoprotetora é bem conhecida, e alfa-tocoferol, um composto com ação antioxidante. Com isso, pretendeu-se desenvolver uma formulação que atue como protetor solar inorgânico, bloqueando a radiação UV e impedindo sua penetração que pode causar sérios danos à pele, além de conter o alfa-tocoferol que interage com os radicais livres, diminuindo os danos causados por estes. Para tanto, inicialmente foram preparadas formulações baseadas em dois diagramas de fases, as amostras que apresentaram separação de fase foram excluídas do trabalho, e as outras foram submetidas à análise de microscopia de luz polarizadas. Através da microscopia de luz polarizada foi possível concluir que a estrutura líquido-cristalina é mantida com a incorporação dos ativos no sistema, o que posteriormente foi confirmado com a análise por SAXS. A análise do potencial zeta permitiu verificar que na faixa de pH entre 5 e 7, indicada para produtos de uso tópico, é possível evitar aglomeração das partículas, e com isso obter um visual transparente do produto. A avaliação do comportamento possibilitou concluir que todas as amostras apresentaram uma consistência ideal para aplicação do produto na pele

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hybrid composites combining metal plates and laminates with continuous fiber reinforced polymer, called fiber-metal (CHMF), have been particularly attractive for aerospace applications, due mainly to their high mechanical strength and stiffness associated with low density. These laminates (CHMF) consist of a sandwich structure consisting of layers of polymer composites and metal plates, stacked alternately. This setting allows you to combine the best mechanical performance of polymer composites reinforced with long fibers, to the high toughness of metals. Environmental effects should always be considered in the design of structural components, because these materials in applications are submitted to the effects of moisture in the atmosphere, the large cyclical variations of temperature around 82 ° C to -56 ° C, and high effort mechanical. The specimens of fibermetal composite were prepared at EMBRAER with titanium plates and laminates of carbon fiber/epoxy resin. This study aims to evaluate the effect of different environmental conditions (water immersion, hygrothermal chamber and thermal shock) of laminate hybrid titanium/carbon fiber/epoxy resin. The effects of conditioning were evaluated by interlaminar shear tests - ILSS, tensile, and vibration free

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The project aims to develop ceramic compounds with gradients of the mechanical properties, using the molding technique with commercial starches. To understand the process of interaction between starch and ceramic powders, the proposed methodology involves viscometry tests (up to 200 °C). Viscometric assays were carried out with slurries of alumina, titania and aluminum titanate with potato starch, cassava and corn. The specimens were tested for dilatometry, thermomechanical, thermal shock, mechanical and characterization by SEM. The ceramic powders and starches were analyzed using the optical microscope to measure the size of these. It was made of th kinetics of starch gelatinization and titania with the cornstarch in theoptical microscope to observe how the grains of starch behaved in welling