972 resultados para Thoraco-abdominal aortic aneurysms


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to establish and validate a three-dimensional imaging protocol for the assessment of Computed Tomography (CT) scans of abdominal aortic aneurysms in UK EVAR trials patients. Quality control and repeatability of anatomical measurements is important for the validity of any core laboratory. METHODS: Three different observers performed anatomical measurements on 50 preoperative CT scans of aortic aneurysms using the Vitrea 2 three-dimensional post-imaging software in a core laboratory setting. We assessed the accuracy of intra and inter observer repeatability of measurements, the time required for collection of measurements, 3 different levels of automation and 3 different automated criteria for measurement of neck length. RESULTS: None of the automated neck length measurements demonstrated sufficient accuracy and it was necessary to perform checking of the important automated landmarks. Good intra and limited inter observer agreement were achieved with three-dimensional assessment. Complete assessment of the aneurysm and iliacs took an average (SD) of 17.2 (4.1) minutes. CONCLUSIONS: Aortic aneurysm anatomy can be assessed reliably and quickly using three-dimensional assessment but for scans of limited quality, manual checking of important landmarks remains necessary. Using a set protocol, agreement between observers is satisfactory but not as good as within observers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Through progress in medical imaging, image analysis and finite element (FE) meshing tools it is now possible to extract patient-specific geometries from medical images of abdominal aortic aneurysms(AAAs), and thus to study clinically-relevant problems via FE simulations. Such simulations allow additional insight into human physiology in both healthy and diseased states. Medical imaging is most often performed in vivo, and hence the reconstructed model geometry in the problem of interest will represent the in vivo state, e.g., the AAA at physiological blood pressure. However, classical continuum mechanics and FE methods assume that constitutive models and the corresponding simulations begin from an unloaded, stress-free reference condition.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Lifelong surveillance after endovascular repair (EVAR) of abdominal aortic aneurysms (AAA) is considered mandatory to detect potentially life-threatening endograft complications. A minority of patients require reintervention but cannot be predictively identified by existing methods. This study aimed to improve the prediction of endograft complications and mortality, through the application of machine-learning techniques. Methods Patients undergoing EVAR at 2 centres were studied from 2004-2010. Pre-operative aneurysm morphology was quantified and endograft complications were recorded up to 5 years following surgery. An artificial neural networks (ANN) approach was used to predict whether patients would be at low- or high-risk of endograft complications (aortic/limb) or mortality. Centre 1 data were used for training and centre 2 data for validation. ANN performance was assessed by Kaplan-Meier analysis to compare the incidence of aortic complications, limb complications, and mortality; in patients predicted to be low-risk, versus those predicted to be high-risk. Results 761 patients aged 75 +/- 7 years underwent EVAR. Mean follow-up was 36+/- 20 months. An ANN was created from morphological features including angulation/length/areas/diameters/ volume/tortuosity of the aneurysm neck/sac/iliac segments. ANN models predicted endograft complications and mortality with excellent discrimination between a low-risk and high-risk group. In external validation, the 5-year rates of freedom from aortic complications, limb complications and mortality were 95.9% vs 67.9%; 99.3% vs 92.0%; and 87.9% vs 79.3% respectively (p0.001) Conclusion This study presents ANN models that stratify the 5-year risk of endograft complications or mortality using routinely available pre-operative data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Les maladies cardiovasculaires sont la première cause de mortalité dans le monde et les anévrismes de l’aorte abdominale (AAAs) font partie de ce lot déplorable. Un anévrisme est la dilatation d’une artère pouvant conduire à la mort. Une rupture d’AAA s’avère fatale près de 80% du temps. Un moyen de traiter les AAAs est l’insertion d’une endoprothèse (SG) dans l’aorte, communément appelée la réparation endovasculaire (EVAR), afin de réduire la pression exercée par le flux sanguin sur la paroi. L’efficacité de ce traitement est compromise par la survenue d’endofuites (flux sanguins entre la prothèse et le sac anévrismal) pouvant conduire à la rupture de l’anévrisme. Ces flux sanguins peuvent survenir à n’importe quel moment après le traitement EVAR. Une surveillance par tomodensitométrie (CT-scan) annuelle est donc requise, augmentant ainsi le coût du suivi post-EVAR et exposant le patient à la radiation ionisante et aux complications des contrastes iodés. L’endotension est le concept de dilatation de l’anévrisme sans la présence d’une endofuite apparente au CT-scan. Après le traitement EVAR, le sang dans le sac anévrismal coagule pour former un thrombus frais, qui deviendra progressivement un thrombus plus fibreux et plus organisé, donnant lieu à un rétrécissement de l’anévrisme. Il y a très peu de données dans la littérature pour étudier ce processus temporel et la relation entre le thrombus frais et l’endotension. L’étalon d’or du suivi post-EVAR, le CT-scan, ne peut pas détecter la présence de thrombus frais. Il y a donc un besoin d’investir dans une technique sécuritaire et moins coûteuse pour le suivi d’AAAs après EVAR. Une méthode récente, l’élastographie dynamique, mesure l’élasticité des tissus en temps réel. Le principe de cette technique repose sur la génération d’ondes de cisaillement et l’étude de leur propagation afin de remonter aux propriétés mécaniques du milieu étudié. Cette thèse vise l’application de l’élastographie dynamique pour la détection des endofuites ainsi que de la caractérisation mécanique des tissus du sac anévrismal après le traitement EVAR. Ce projet dévoile le potentiel de l’élastographie afin de réduire les dangers de la radiation, de l’utilisation d’agent de contraste ainsi que des coûts du post-EVAR des AAAs. L’élastographie dynamique utilisant le « Shear Wave Imaging » (SWI) est prometteuse. Cette modalité pourrait complémenter l’échographie-Doppler (DUS) déjà utilisée pour le suivi d’examen post-EVAR. Le SWI a le potentiel de fournir des informations sur l’organisation fibreuse du thrombus ainsi que sur la détection d’endofuites. Tout d’abord, le premier objectif de cette thèse consistait à tester le SWI sur des AAAs dans des modèles canins pour la détection d’endofuites et la caractérisation du thrombus. Des SGs furent implantées dans un groupe de 18 chiens avec un anévrisme créé au moyen de la veine jugulaire. 4 anévrismes avaient une endofuite de type I, 13 avaient une endofuite de type II et un anévrisme n’avait pas d’endofuite. Des examens échographiques, DUS et SWI ont été réalisés à l’implantation, puis 1 semaine, 1 mois, 3 mois et 6 mois après le traitement EVAR. Une angiographie, un CT-scan et des coupes macroscopiques ont été produits au sacrifice. Les régions d’endofuites, de thrombus frais et de thrombus organisé furent identifiées et segmentées. Les valeurs de rigidité données par le SWI des différentes régions furent comparées. Celles-ci furent différentes de façon significative (P < 0.001). Également, le SWI a pu détecter la présence d’endofuites où le CT-scan (1) et le DUS (3) ont échoué. Dans la continuité de ces travaux, le deuxième objectif de ce projet fut de caractériser l’évolution du thrombus dans le temps, de même que l’évolution des endofuites après embolisation dans des modèles canins. Dix-huit anévrismes furent créés dans les artères iliaques de neuf modèles canins, suivis d’une endofuite de type I après EVAR. Deux gels embolisants (Chitosan (Chi) ou Chitosan-Sodium-Tetradecyl-Sulfate (Chi-STS)) furent injectés dans le sac anévrismal pour promouvoir la guérison. Des examens échographiques, DUS et SWI ont été effectués à l’implantation et après 1 semaine, 1 mois, 3 mois et 6 mois. Une angiographie, un CT-scan et un examen histologique ont été réalisés au sacrifice afin d’évaluer la présence, le type et la grosseur de l’endofuite. Les valeurs du module d’élasticité des régions d’intérêts ont été identifiées et segmentées sur les données pathologiques. Les régions d’endofuites et de thrombus frais furent différentes de façon significative comparativement aux autres régions (P < 0.001). Les valeurs d’élasticité du thrombus frais à 1 semaine et à 3 mois indiquent que le SWI peut évaluer la maturation du thrombus, de même que caractériser l’évolution et la dégradation des gels embolisants dans le temps. Le SWI a pu détecter des endofuites où le DUS a échoué (2) et, contrairement au CT-scan, détecter la présence de thrombus frais. Finalement, la dernière étape du projet doctoral consistait à appliquer le SWI dans une phase clinique, avec des patients humains ayant déjà un AAA, pour la détection d’endofuite et la caractérisation de l’élasticité des tissus. 25 patients furent sélectionnés pour participer à l’étude. Une comparaison d’imagerie a été produite entre le SWI, le CT-scan et le DUS. Les valeurs de rigidité données par le SWI des différentes régions (endofuite, thrombus) furent identifiées et segmentées. Celles-ci étaient distinctes de façon significative (P < 0.001). Le SWI a détecté 5 endofuites sur 6 (sensibilité de 83.3%) et a eu 6 faux positifs (spécificité de 76%). Le SWI a pu détecter la présence d’endofuites où le CT-scan (2) ainsi que le DUS (2) ont échoué. Il n’y avait pas de différence statistique notable entre la rigidité du thrombus pour un AAA avec endofuite et un AAA sans endofuite. Aucune corrélation n’a pu être établie de façon significative entre les diamètres des AAAs ainsi que leurs variations et l’élasticité du thrombus. Le SWI a le potentiel de détecter les endofuites et caractériser le thrombus selon leurs propriétés mécaniques. Cette technique pourrait être combinée au suivi des AAAs post-EVAR, complémentant ainsi l’imagerie DUS et réduisant le coût et l’exposition à la radiation ionisante et aux agents de contrastes néphrotoxiques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coronary heart disease is a major cause of morbidity and mortality worldwide. Percutaneous coronary intervention (PCI) has become the most widely used method of coronary artery revascularisation. The use of stents to hold open atherosclerosis induced arterial narrowing has significantly reduced elastic recoil and acute vessel occlusion following balloon angioplasty. However, bare metal stents have been associated with in-stent restenosis attributed to vascular smooth muscle cell (VSMC) hyperplasia and excessive neointimal formation. The resultant luminal renarrowing may manifest clinically with the return of symptoms such as chest pain or shortness of breath. The development of drug eluting stents has significantly reduced the incidence of in-stent restenosis (ISR). Unfortunately the antiproliferative medications used not only inhibit VSMC proliferation but also re-endothelialisation of the stented vessel. In addition, the drug impregnated polymer coating has been associated with a chronic inflammatory response within the vessel wall predisposing patients to stent thrombosis. Thus the identification of novel therapies which promote vessel healing without excessive proliferative or inflammatory response may improve long term outcome and reduce the need for repeated revascularisation. MicroRNAs (miRs) are short (18-25 nucleotide) non-coding RNAs acting to regulate gene expression. By binding to the 3’untranslated region of mRNA they act to fine tune gene expression either by mRNA degradation or translational repression. Originally identified in coordinating tissue development microRNAs have also been shown to play important roles coordinating the inflammatory response and in numerous cardiovascular diseases. MiR-21 has been identified in human atherosclerotic plaques, arteriosclerosis obliterans and abdominal aortic aneurysms. In addition, its up regulation has been documented in preclinical models of vascular injury. This study sought to identify the role of miR-21 in the development of ISR. Utilising a small animal model of stenting and in vitro techniques, we sought to investigate its influence upon VSMC and immune cell response following stenting. 19 The refinement of a murine stenting model within the Baker laboratory and the electrochemical dissolution of the metal stent from within harvested vascular tissues significantly improved the ability to perform detailed histological analysis. In addition, identification of miRNAs using in situ hybridisation was achieved for the first time within stented tissue. Neointimal formation and ISR was significantly reduced in mice in which miR-21 had been genetically deleted. In addition, neointimal composition was found to be altered in miR-21 KO mice with reductions in VSMC and elastin content demonstrated. Importantly, no difference in re-endothelialisation was observed. In vitro analysis demonstrated that VSMCs from miR-21 KO mice had both reduced proliferative and migratory capacity following platelet derived growth factor stimulation. Molecular analysis revealed that these differences may, at least in part, be due to de-repression of programmed cell death 4 (PDCD4). PDCD4 is a known miR-21 target within VSMCs implicated in the suppression of proliferation and promotion of apoptosis. Unfortunately, initial attempts at antimiR mediated knockdown of miR-21 in vivo, failed to produce a similar change in the suppression of ISR. Furthermore, a significant alteration in macrophage polarisation state within the neointima of miR-21 WT and KO mice was noted. Immunohistochemical staining revealed a preponderance of anti-inflammatory M2 macrophages in KO mice. Analysis of bone marrow derived macrophages from miR-21 KO mice demonstrated an increased level of the peroxisome proliferation activating receptor-γ (PPARγ) which facilitates M2 polarisation. Importantly, significant alterations in numerous pro-inflammatory cytokines, which also have mitogenic effects, were also found following genetic deletion of miR-21. In Summary, this is the first study to look at miRs in the development of ISR. MiR-21 plays an important role in the development of ISR by influencing the proliferative response of VSMCs and modulating the immune response following stent deployment. Further attempts to modulate miR-21 expression following PCI may reduce ISR and the need for repeat revascularisation while also reducing the risk of stent thrombosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Les maladies cardiovasculaires sont la première cause de mortalité dans le monde et les anévrismes de l’aorte abdominale (AAAs) font partie de ce lot déplorable. Un anévrisme est la dilatation d’une artère pouvant conduire à la mort. Une rupture d’AAA s’avère fatale près de 80% du temps. Un moyen de traiter les AAAs est l’insertion d’une endoprothèse (SG) dans l’aorte, communément appelée la réparation endovasculaire (EVAR), afin de réduire la pression exercée par le flux sanguin sur la paroi. L’efficacité de ce traitement est compromise par la survenue d’endofuites (flux sanguins entre la prothèse et le sac anévrismal) pouvant conduire à la rupture de l’anévrisme. Ces flux sanguins peuvent survenir à n’importe quel moment après le traitement EVAR. Une surveillance par tomodensitométrie (CT-scan) annuelle est donc requise, augmentant ainsi le coût du suivi post-EVAR et exposant le patient à la radiation ionisante et aux complications des contrastes iodés. L’endotension est le concept de dilatation de l’anévrisme sans la présence d’une endofuite apparente au CT-scan. Après le traitement EVAR, le sang dans le sac anévrismal coagule pour former un thrombus frais, qui deviendra progressivement un thrombus plus fibreux et plus organisé, donnant lieu à un rétrécissement de l’anévrisme. Il y a très peu de données dans la littérature pour étudier ce processus temporel et la relation entre le thrombus frais et l’endotension. L’étalon d’or du suivi post-EVAR, le CT-scan, ne peut pas détecter la présence de thrombus frais. Il y a donc un besoin d’investir dans une technique sécuritaire et moins coûteuse pour le suivi d’AAAs après EVAR. Une méthode récente, l’élastographie dynamique, mesure l’élasticité des tissus en temps réel. Le principe de cette technique repose sur la génération d’ondes de cisaillement et l’étude de leur propagation afin de remonter aux propriétés mécaniques du milieu étudié. Cette thèse vise l’application de l’élastographie dynamique pour la détection des endofuites ainsi que de la caractérisation mécanique des tissus du sac anévrismal après le traitement EVAR. Ce projet dévoile le potentiel de l’élastographie afin de réduire les dangers de la radiation, de l’utilisation d’agent de contraste ainsi que des coûts du post-EVAR des AAAs. L’élastographie dynamique utilisant le « Shear Wave Imaging » (SWI) est prometteuse. Cette modalité pourrait complémenter l’échographie-Doppler (DUS) déjà utilisée pour le suivi d’examen post-EVAR. Le SWI a le potentiel de fournir des informations sur l’organisation fibreuse du thrombus ainsi que sur la détection d’endofuites. Tout d’abord, le premier objectif de cette thèse consistait à tester le SWI sur des AAAs dans des modèles canins pour la détection d’endofuites et la caractérisation du thrombus. Des SGs furent implantées dans un groupe de 18 chiens avec un anévrisme créé au moyen de la veine jugulaire. 4 anévrismes avaient une endofuite de type I, 13 avaient une endofuite de type II et un anévrisme n’avait pas d’endofuite. Des examens échographiques, DUS et SWI ont été réalisés à l’implantation, puis 1 semaine, 1 mois, 3 mois et 6 mois après le traitement EVAR. Une angiographie, un CT-scan et des coupes macroscopiques ont été produits au sacrifice. Les régions d’endofuites, de thrombus frais et de thrombus organisé furent identifiées et segmentées. Les valeurs de rigidité données par le SWI des différentes régions furent comparées. Celles-ci furent différentes de façon significative (P < 0.001). Également, le SWI a pu détecter la présence d’endofuites où le CT-scan (1) et le DUS (3) ont échoué. Dans la continuité de ces travaux, le deuxième objectif de ce projet fut de caractériser l’évolution du thrombus dans le temps, de même que l’évolution des endofuites après embolisation dans des modèles canins. Dix-huit anévrismes furent créés dans les artères iliaques de neuf modèles canins, suivis d’une endofuite de type I après EVAR. Deux gels embolisants (Chitosan (Chi) ou Chitosan-Sodium-Tetradecyl-Sulfate (Chi-STS)) furent injectés dans le sac anévrismal pour promouvoir la guérison. Des examens échographiques, DUS et SWI ont été effectués à l’implantation et après 1 semaine, 1 mois, 3 mois et 6 mois. Une angiographie, un CT-scan et un examen histologique ont été réalisés au sacrifice afin d’évaluer la présence, le type et la grosseur de l’endofuite. Les valeurs du module d’élasticité des régions d’intérêts ont été identifiées et segmentées sur les données pathologiques. Les régions d’endofuites et de thrombus frais furent différentes de façon significative comparativement aux autres régions (P < 0.001). Les valeurs d’élasticité du thrombus frais à 1 semaine et à 3 mois indiquent que le SWI peut évaluer la maturation du thrombus, de même que caractériser l’évolution et la dégradation des gels embolisants dans le temps. Le SWI a pu détecter des endofuites où le DUS a échoué (2) et, contrairement au CT-scan, détecter la présence de thrombus frais. Finalement, la dernière étape du projet doctoral consistait à appliquer le SWI dans une phase clinique, avec des patients humains ayant déjà un AAA, pour la détection d’endofuite et la caractérisation de l’élasticité des tissus. 25 patients furent sélectionnés pour participer à l’étude. Une comparaison d’imagerie a été produite entre le SWI, le CT-scan et le DUS. Les valeurs de rigidité données par le SWI des différentes régions (endofuite, thrombus) furent identifiées et segmentées. Celles-ci étaient distinctes de façon significative (P < 0.001). Le SWI a détecté 5 endofuites sur 6 (sensibilité de 83.3%) et a eu 6 faux positifs (spécificité de 76%). Le SWI a pu détecter la présence d’endofuites où le CT-scan (2) ainsi que le DUS (2) ont échoué. Il n’y avait pas de différence statistique notable entre la rigidité du thrombus pour un AAA avec endofuite et un AAA sans endofuite. Aucune corrélation n’a pu être établie de façon significative entre les diamètres des AAAs ainsi que leurs variations et l’élasticité du thrombus. Le SWI a le potentiel de détecter les endofuites et caractériser le thrombus selon leurs propriétés mécaniques. Cette technique pourrait être combinée au suivi des AAAs post-EVAR, complémentant ainsi l’imagerie DUS et réduisant le coût et l’exposition à la radiation ionisante et aux agents de contrastes néphrotoxiques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: A 24-year-old man presented with previously diagnosed Marfan's syndrome. Since the age of 9 years, he had undergone eight cardiovascular procedures to treat rapidly progressive aneurysms, dissection and tortuous vascular disease involving the aortic root and arch, the thoracoabdominal aorta, and brachiocephalic, vertebral, internal thoracic and superior mesenteric arteries. Throughout this extensive series of cardiovascular surgical repairs, he recovered without stroke, paraplegia or renal impairment. INVESTIGATIONS: CT scans, arteriogram, genetic mutation screening of transforming growth factor beta receptors 1 and 2. DIAGNOSIS: Diffuse and rapidly progressing vascular disease in a patient who met the diagnostic criteria for Marfan's syndrome, but was later rediagnosed with Loeys-Dietz syndrome. Genetic testing also revealed a de novo mutation in transforming growth factor beta receptor 2. MANAGEMENT: Regular cardiovascular surveillance for aneurysms and dissections, and aggressive surgical treatment of vascular disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Bases Gerais da Cirurgia - FMB

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Um longo caminho foi percorrido desde as primeiras intervenções cirúrgicas feitas para o tratamento do aneurisma de aorta abdominal. Ao longo deste tempo, várias inovações foram criadas, no sentido de reduzir a invasividade dos procedimentos e melhorar sua segurança e durabilidade. Nesta revisão, são discutidos os principais e recentes avanços em intervenções sobre aneurismas aórticos, incluindo a restauração aórtica endovascular, a cirurgia aórtica videolaparoscópica, as técnicas híbridas convencionais e endovasculares, as técnicas combinadas videolaparoscópicas e endovasculares, bem como as perspectivas futuras, tanto para aorta torácica como abdominal. Diante de tantas transformações e evolução, o cirurgião vascular moderno terá que ter sua mente aberta para as novidades e desenvolver capacitação ampla com diferentes técnicas para proporcionar a melhor opção terapêutica para seus pacientes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The sandwich technique is an endovascular off-the-shelf solution for patients with thoracoabdominal aortic aneurysms (TAAAs). In a sandwich configuration, the chimney stent runs in the middle of a space created by two or three aortic endografts.Methods: All patients with TAAAs who were treated with the sandwich technique were included in the study. Self-expanding Viabahn grafts (W. L. Gore and Associates Inc, Flagstaff, Ariz) were used as parallel grafts in the renal arteries and visceral vessels. Caudad-facing chimney grafts were used for the visceral arteries and cephalad-facing periscope grafts for the renal arteries.Results: During the study period, 32 patients with TAAAs were treated with sandwich grafts. Indication for the procedure in 43% was an acute onset of symptoms, including two patients with a rupture and a retroperitoneal hematoma. Three patients required an additional debranching procedure. A total of 104 chimney grafts were implanted. Two patients died postoperatively because of the operation. Major adverse events were recorded in five patients, including one patient with persistent paraplegia and two with permanent renal failure requiring dialysis. The incidence of chimney graft occlusion was higher in patients with three or four parallel grafts than in those with two chimney grafts only. Patients with chronic dissections had a 12-times higher incidence of chimney graft occlusion than aneurysm patients. The number of patients with type I or III endoleaks was higher in the group with three or four parallel grafts.Conclusions: The sandwich technique is an off-the-shelf endovascular alternative to treat patients with TAAAs in an emergent setting. The combination of chimney grafts with a periscope configuration enables a rapid endovascular aneurysm exclusion with acceptable midterm results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hydronephrosis is a condition that results from complete or partial obstruction of the urinary flow. This paper reports the case of a two-year-old, mixed-breed dog diagnosed with hydronephrosis of the left kidney six months after being kicked in the thoraco-abdominal region. The diagnosis was based on radiographic and ultrasonographic examinations. Percutaneous antegrade pyelography was also performed and allowed the visualization of opacification of the left kidney, which confirmed the diagnosis. Because the exams indicated that the patient had normal renal function, nephrectomy was performed. The patient remained in good health during the postoperative period and in subsequent evaluations. (C) 2013 PVJ. All rights reserved

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A deficiência do fator XI, também conhecida como hemofilia C, é uma doença hematológica hereditária rara, que se manifesta clinicamente com hemorragia persistente após cirurgias, traumas, menorragias e extrações dentárias. Neste artigo, relatou-se a correção endovascular de um paciente com aneurisma de aorta e de artéria ilíaca comum esquerda em um paciente portador de deficiência major do fator XI (atividade do fator XI inferior a 20%). O procedimento foi realizado com sucesso, com o manuseio do distúrbio da coagulação por meio da infusão de plasma fresco no pré-operatório imediato e no pós-operatório, e controle laboratorial da coagulação do paciente.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Acute dissection and rupture of aortic aneurysms comprise for 1-2% of all deaths in industrialized countries. Dilation of the aorta is caused by a multitude of mechanisms including inherited connective tissue disorders such as Marfan syndrome (MFS). MFS is one of the most common inherited connective tissue disorders affecting 1 in 5000 individuals. Although the phenotype of MFS can be quite variable, aneurysmal dilation of the aortic root and consecutive acute aortic dissection is the leading cause of death in this patient population. Over the past years it has been shown that a comprehensive understanding of this disorder provides greater understanding of vascular wall biology and identifies pathways relevant to aortic aneurysms and dissection in general. The current review discusses the surgical management of patients with MFS with a special emphasis on indications for surgery in this complex group of patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study assessed the feasibility and effectiveness of remote neuromonitoring as an adjunct to spinal cord protection during surgical repair of descending thoracic aortic aneurysms and thoracoabdominal aortic aneurysms.