997 resultados para Thickness dependence
Resumo:
Purpose: To compare the retinal thickness (RT) and choroidal thickness (ChT) between the fellow eyes of non-amblyopic myopic anisometropes. Methods: The eyes of 22 non-amblyopic myopic anisometropes (1 D spherical equivalent refraction [SER] anisometropia) were examined using spectral domain optical coherence tomography (SD-OCT). Customised software was used to register, align and average multiple foveal OCT B-Scan images from each subject in order to enhance image quality. Two independent masked observers manually determined the RT and ChT from each SD-OCT image up to 2.5 mm nasal and temporal to the fovea. Axial length (AXL) was measured using optical low coherence biometry during relaxed accommodation. Results: The mean SER anisometropia was 1.74 ± 0.95 D and the mean interocular AXL difference was 0.58 ± 0.41 mm. There was no significant difference in foveal RT between the fellow eyes (P > 0.05). Mean subfoveal ChT was significantly thinner in the more myopic eye (252 ± 46 μm compared to the fellow, less myopic eye (286 ± 58 μm) (P < 0.001). There was a moderate correlation between the interocular difference in subfoveal ChT and the interocular difference in AXL (r = -0.50, P < 0.01). Asian anisometropes displayed more regionally symmetrical (nasal-temporal)interocular differences in ChT profile compared to Caucasians. Conclusions: RT was similar between the fellow eyes of myopic anisometropes; however, the subfoveal choroid was significantly thinner in the more myopic (longer) eye of this anisometropic cohort. The interocular asymmetry in ChT correlated with the interocular difference in AXL.
Resumo:
Purpose: The measurement of broadband ultrasonic attenuation (BUA) in cancellous bone for the assessment of osteoporosis follows a parabolic-type dependence with bone volume fraction; having minima values corresponding to both entire bone and entire marrow. Langton has recently proposed that the primary BUA mechanism may be significant phase interference due to variations in propagation transit time through the test sample as detected over the phase-sensitive surface of the receive ultrasound transducer. This fundamentally simple concept assumes that the propagation of ultrasound through a complex solid : liquid composite sample such as cancellous bone may be considered by an array of parallel ‘sonic rays’. The transit time of each ray is defined by the proportion of bone and marrow propagated, being a minimum (tmin) solely through bone and a maximum (tmax) solely through marrow. A Transit Time Spectrum (TTS), ranging from tmin to tmax, may be defined describing the proportion of sonic rays having a particular transit time, effectively describing lateral inhomogeneity of transit time over the surface of the receive ultrasound transducer. Phase interference may result from interaction of ‘sonic rays’ of differing transit times. The aim of this study was to test the hypothesis that there is a dependence of phase interference upon the lateral inhomogenity of transit time by comparing experimental measurements and computer simulation predictions of ultrasound propagation through a range of relatively simplistic solid:liquid models exhibiting a range of lateral inhomogeneities. Methods: A range of test models was manufactured using acrylic and water as surrogates for bone and marrow respectively. The models varied in thickness in one dimension normal to the direction of propagation, hence exhibiting a range of transit time lateral inhomogeneities, ranging from minimal (single transit time) to maximal (wedge; ultimately the limiting case where each sonic ray has a unique transit time). For the experimental component of the study, two unfocused 1 MHz ¾” broadband diameter transducers were utilized in transmission mode; ultrasound signals were recorded for each of the models. The computer simulation was performed with Matlab, where the transit time and relative amplitude of each sonic ray was calculated. The transit time for each sonic ray was defined as the sum of transit times through acrylic and water components. The relative amplitude considered the reception area for each sonic ray along with absorption in the acrylic. To replicate phase-sensitive detection, all sonic rays were summed and the output signal plotted in comparison with the experimentally derived output signal. Results: From qualtitative and quantitative comparison of the experimental and computer simulation results, there is an extremely high degree of agreement of 94.2% to 99.0% between the two approaches, supporting the concept that propagation of an ultrasound wave, for the models considered, may be approximated by a parallel sonic ray model where the transit time of each ray is defined by the proportion of ‘bone’ and ‘marrow’. Conclusions: This combined experimental and computer simulation study has successfully demonstrated that lateral inhomogeneity of transit time has significant potential for phase interference to occur if a phase-sensitive ultrasound receive transducer is implemented as in most commercial ultrasound bone analysis devices.
Resumo:
Boards of directors are key governancemechanisms in organizations and fulfill twomain tasks:monitoringmanagers and firm performance, and providing advice and access to resources. In spite of a wealth of researchmuch remains unknown about how boards attend to the two tasks. This study investigates whether organizational (firm profitability) and environmental factors (industry regulation) affect board task performance. The data combine CEOs' responses to a questionnaire, and archival data from a sample of large Italian firms. Findings show that past firm performance is negatively associatedwith board monitoring and advice tasks; greater industry regulation enhances perceived board task performance; board monitoring and advice tasks tend to reinforce each other, despite their theoretical and practical distinction.
Resumo:
In this paper we report a new neutron Compton scattering (NCS) measurement of the ground state single atom kinetic energy of polycrystalline beryllium at momentum transfers in the range 27}104 As ~1 and temperatures in the range 110}1150 K. The measurements have been made with the electron Volt spectrometer (eVS) at the ISIS facility and the measured kinetic energies are shown to be &10% higher than calculations made in the harmonic approximation.
Resumo:
In this paper, the influence of the impact energy on the initial fabrication of thin films formed by low energy cluster deposition was investigated by molecular dynamics simulation of All 3 clusters depositing on Ni(0 0 1) substrate. In the case of soft-landing, (0.01 eV/atom), clusters are rearranged from I-h symmetry into fcc-like clusters on the surface. Then they aggregate each other, which result in thin film growing in 3D island mode. While, growth will be in layer-by-layer mode at the impact energy of a few electron volt due to the transient lateral spread of cluster atoms induced by dense collision cascade. This effect has been traced to collision cascade inside the cluster. which is enhanced by collision with a hard Ni substrate. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
The deposition of hyperthermal CH3 on diamond (001)-(2×1) surface at room temperature has been studied by means of molecular dynamics simulation using the many-body hydrocarbon potential. The energy threshold effect has been observed. That is, with fixed collision geometry, chemisorption can occur only when the incident energy of CH3 is above a critical value (Eth). Increasing the incident energy, dissociation of hydrogen atoms from the incident molecule was observed. The chemisorption probability of CH3 as a function of its incident energy was calculated and compared with that of C2H2. We found that below 10 eV, the chemisorption probability of C2H2 is much lower than that of CH3 on the same surface. The interesting thing is that it is even lower than that of CH3 on a hydrogen covered surface at the same impact energy. It indicates that the reactive CH3 molecule is the more important species than C2H2 in diamond synthesis at low energy, which is in good agreement with the experimental observation.
Resumo:
Introduction: The use of amorphous-silicon electronic portal imaging devices (a-Si EPIDs) for dosimetry is complicated by the effects of scattered radiation. In photon radiotherapy, primary signal at the detector can be accompanied by photons scattered from linear accelerator components, detector materials, intervening air, treatment room surfaces (floor, walls, etc) and from the patient/phantom being irradiated. Consequently, EPID measurements which presume to take scatter into account are highly sensitive to the identification of these contributions. One example of this susceptibility is the process of calibrating an EPID for use as a gauge of (radiological) thickness, where specific allowance must be made for the effect of phantom-scatter on the intensity of radiation measured through different thicknesses of phantom. This is usually done via a theoretical calculation which assumes that phantom scatter is linearly related to thickness and field-size. We have, however, undertaken a more detailed study of the scattering effects of fields of different dimensions when applied to phantoms of various thicknesses in order to derive scattered-primary ratios (SPRs) directly from simulation results. This allows us to make a more-accurate calibration of the EPID, and to qualify the appositeness of the theoretical SPR calculations. Methods: This study uses a full MC model of the entire linac-phantom-detector system simulated using EGSnrc/BEAMnrc codes. The Elekta linac and EPID are modelled according to specifications from the manufacturer and the intervening phantoms are modelled as rectilinear blocks of water or plastic, with their densities set to a range of physically realistic and unrealistic values. Transmissions through these various phantoms are calculated using the dose detected in the model EPID and used in an evaluation of the field-size-dependence of SPR, in different media, applying a method suggested for experimental systems by Swindell and Evans [1]. These results are compared firstly with SPRs calculated using the theoretical, linear relationship between SPR and irradiated volume, and secondly with SPRs evaluated from our own experimental data. An alternate evaluation of the SPR in each simulated system is also made by modifying the BEAMnrc user code READPHSP, to identify and count those particles in a given plane of the system that have undergone a scattering event. In addition to these simulations, which are designed to closely replicate the experimental setup, we also used MC models to examine the effects of varying the setup in experimentally challenging ways (changing the size of the air gap between the phantom and the EPID, changing the longitudinal position of the EPID itself). Experimental measurements used in this study were made using an Elekta Precise linear accelerator, operating at 6MV, with an Elekta iView GT a-Si EPID. Results and Discussion: 1. Comparison with theory: With the Elekta iView EPID fixed at 160 cm from the photon source, the phantoms, when positioned isocentrically, are located 41 to 55 cm from the surface of the panel. At this geometry, a close but imperfect agreement (differing by up to 5%) can be identified between the results of the simulations and the theoretical calculations. However, this agreement can be totally disrupted by shifting the phantom out of the isocentric position. Evidently, the allowance made for source-phantom-detector geometry by the theoretical expression for SPR is inadequate to describe the effect that phantom proximity can have on measurements made using an (infamously low-energy sensitive) a-Si EPID. 2. Comparison with experiment: For various square field sizes and across the range of phantom thicknesses, there is good agreement between simulation data and experimental measurements of the transmissions and the derived values of the primary intensities. However, the values of SPR obtained through these simulations and measurements seem to be much more sensitive to slight differences between the simulated and real systems, leading to difficulties in producing a simulated system which adequately replicates the experimental data. (For instance, small changes to simulated phantom density make large differences to resulting SPR.) 3. Comparison with direct calculation: By developing a method for directly counting the number scattered particles reaching the detector after passing through the various isocentric phantom thicknesses, we show that the experimental method discussed above is providing a good measure of the actual degree of scattering produced by the phantom. This calculation also permits the analysis of the scattering sources/sinks within the linac and EPID, as well as the phantom and intervening air. Conclusions: This work challenges the assumption that scatter to and within an EPID can be accounted for using a simple, linear model. Simulations discussed here are intended to contribute to a fuller understanding of the contribution of scattered radiation to the EPID images that are used in dosimetry calculations. Acknowledgements: This work is funded by the NHMRC, through a project grant, and supported by the Queensland University of Technology (QUT) and the Royal Brisbane and Women's Hospital, Brisbane, Australia. The authors are also grateful to Elekta for the provision of manufacturing specifications which permitted the detailed simulation of their linear accelerators and amorphous-silicon electronic portal imaging devices. Computational resources and services used in this work were provided by the HPC and Research Support Group, QUT, Brisbane, Australia.
Resumo:
This thesis studied the source of instability in optical phase modulators used in high accuracy laser measurement systems. The nonlinear origin of the amplitude noise helped further reducing this instability in applications that rely on phase modulators to function. This outcome will have positive impacts on the development of new methods in the amplitude noise suppression.
Resumo:
This study aimed to investigate drink driving in a sample of general drivers and convicted drunk driving offenders in Guangzhou, China. The study also aimed to explore some potential factors that impact on alcohol-related driving behaviour. Samples of 406 general drivers and 101 drunk driving offenders were recruited between May and October 2012. A survey was used to collect information about demographic characteristics, knowledge, attitudes and practices related to drink driving. The Alcohol Use Disorders Identification Test (AUDIT) was used to assess possible drinking problems. The average age reported for starting to drink alcohol for both groups of participants was around 19 years old. The mean AUDIT score of general drivers was 7.4 (SD = 5.4) representing a low level of alcohol problems, and for convicted drunk driving offenders was 11.1 (SD = 5.9) representing a medium level of alcohol problems (significant difference between means, t = 5.75, p < 0.001). AUDIT scores indicated that a substantial proportion (65%) of the offenders had medium to high levels of alcohol use disorders, compared with 38.5% among general drivers. Offenders who knew the drunk driving legal limit had a lower AUDIT score (M = 9.8, SD = 5.16) than those who did not know it (M = 12.2, SD = 6.257, t = -1.987. p = 0.05). In addition, offenders who were novice drivers (licensed less than 2 years) had a higher AUDIT score (M = 16.4, SD = 7.6) than the other three driver experience categories used.
Resumo:
The use of immobilised TiO2 for the purification of polluted water streams introduces the necessity to evaluate the effect of mechanisms such as the transport of pollutants from the bulk of the liquid to the catalyst surface and the transport phenomena inside the porous film. Experimental results of the effects of film thickness on the observed reaction rate for both liquid-side and support-side illumination are here compared with the predictions of a one-dimensional mathematical model of the porous photocatalytic slab. Good agreement was observed between the experimentally obtained photodegradation of phenol and its by-products, and the corresponding model predictions. The results have confirmed that an optimal catalyst thickness exists and, for the films employed here, is 5 μm. Furthermore, the modelling results have highlighted the fact that porosity, together with the intrinsic reaction kinetics are the parameters controlling the photocatalytic activity of the film. The former by influencing transport phenomena and light absorption characteristics, the latter by naturally dictating the rate of reaction.
Application of near infrared (NIR) spectroscopy for determining the thickness of articular cartilage
Resumo:
The determination of the characteristics of articular cartilage such as thickness, stiffness and swelling, especially in the form that can facilitate real-time decisions and diagnostics is still a matter for research and development. This paper correlates near infrared spectroscopy with mechanically measured cartilage thickness to establish a fast, non-destructive, repeatable and precise protocol for determining this tissue property. Statistical correlation was conducted between the thickness of bovine cartilage specimens (n = 97) and regions of their near infrared spectra. Nine regions were established along the full absorption spectrum of each sample and were correlated with the thickness using partial least squares (PLS) regression multivariate analysis. The coefficient of determination (R2) varied between 53 and 93%, with the most predictive region (R2 = 93.1%, p < 0.0001) for cartilage thickness lying in the region (wavenumber) 5350–8850 cm−1. Our results demonstrate that the thickness of articular cartilage can be measured spectroscopically using NIR light. This protocol is potentially beneficial to clinical practice and surgical procedures in the treatment of joint disease such as osteoarthritis.
Resumo:
Purpose To examine choroidal thickness (ChT) and its spatial distribution across the posterior pole in pediatric subjects with normal ocular health and minimal refractive error. Methods ChT was assessed using spectral domain optical coherence tomography (OCT) in 194 children aged between 4-12 years, with spherical equivalent refractive errors between +1.25 and -0.50 DS. A series of OCT scans were collected, imaging the choroid along 4 radial scan lines centered on the fovea (each separated by 45°). Frame averaging was used to reduce noise and enhance chorio-scleral junction visibility. The transverse scale of each scan was corrected to account for magnification effects associated with axial length. Two independent masked observers manually segmented the OCT images to determine ChT at foveal centre, and averaged across a series of perifoveal zones over the central 5 mm. Results The average subfoveal ChT was 330 ± 65 µm (range 189-538 µm), and was significantly influenced by age (p=0.04). The ChT of the 4 to 6 year old age group (312 ± 62 µm) was significantly thinner compared to the 7 to 9 year olds (337 ± 65 µm, p<0.05) and bordered on significance compared to the 10 to 12 year olds (341 ± 61 µm, p=0.08). ChT also exhibited significant variation across the posterior pole, being thicker in more central regions. The choroid was thinner nasally and inferiorly compared to temporally and superiorly. Multiple regression analysis revealed age, axial length and anterior chamber depth were significantly associated with subfoveal ChT (p<0.001). Conclusions ChT increases significantly from early childhood to adolescence. This appears to be a normal feature of childhood eye growth.
Resumo:
Our results demonstrate that photorefractive residual amplitude modulation (RAM) noise in electro-optic modulators (EOMs) can be reduced by modifying the incident beam intensity distribution. Here we report an order of magnitude reduction in RAM when beams with uniform intensity (flat-top) profiles, generated with an LCOS-SLM, are used instead of the usual fundamental Gaussian mode (TEM00). RAM arises from the photorefractive amplified scatter noise off the defects and impurities within the crystal. A reduction in RAM is observed with increasing intensity uniformity (flatness), which is attributed to a reduction in space charge field on the beam axis. The level of RAM reduction that can be achieved is physically limited by clipping at EOM apertures, with the observed results agreeing well with a simple model. These results are particularly important in applications where the reduction of residual amplitude modulation to 10^-6 is essential.