974 resultados para Tests de non corrélation


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In practice, piles are most often modelled as "Beams on Non-Linear Winkler Foundation" (also known as “p-y spring” approach) where the soil is idealised as p-y springs. These p-y springs are obtained through semi-empirical approach using element test results of the soil. For liquefied soil, a reduction factor (often termed as p-multiplier approach) is applied on a standard p-y curve for the non-liquefied condition to obtain the p-y curve liquefied soil condition. This paper presents a methodology to obtain p-y curves for liquefied soil based on element testing of liquefied soil considering physically plausible mechanisms. Validation of the proposed p-y curves is carried out through the back analysis of physical model tests.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article examines some preliminary tests which were performed in order to evaluate the best electrode configuration (width and spacing) for cell culture analyses. Biochips packaged with indium tin oxide (ITO) interdigitated electrodes (IDEs) were used to perform impedance measurements on A549 cells cultured on the surface of the biochip. Several tests were carried out using a 10 mM solution of Sodium Chloride (NaCl), cell medium and the cell culture itself to characterize some of the configurations already fabricated in the facilities at Tyndall National Institute.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Efficient early identification of primary immunodeficiency disease (PID) is important for prognosis, but is not an easy task for non-immunologists. The Clinical Working Party of the European Society for Immunodeficiencies (ESID) has composed a multi-stage diagnostic protocol that is based on expert opinion, in order to increase the awareness of PID among doctors working in different fields. The protocol starts from the clinical presentation of the patient; immunological skills are not needed for its use. The multi-stage design allows cost-effective screening for PID within the large pool of potential cases in all hospitals in the early phases, while more expensive tests are reserved for definitive classification in collaboration with an immunologist at a later stage. Although many PIDs present in childhood, others may present at any age. The protocols presented here are therefore aimed at both adult physicians and paediatricians. While designed for use throughout Europe, there will be national differences which may make modification of this generic algorithm necessary.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Optimally, expanded HIV testing programs should reduce barriers to testing while attracting new and high-risk testers. We assessed barriers to testing and HIV risk among clients participating in mobile voluntary counseling and testing (MVCT) campaigns in four rural villages in the Kilimanjaro Region of Tanzania. METHODS: Between December 2007 and April 2008, 878 MVCT participants and 506 randomly selected community residents who did not access MVCT were surveyed. Gender-specific logistic regression models were used to describe differences in socioeconomic characteristics, HIV exposure risk, testing histories, HIV related stigma, and attitudes toward testing between MVCT participants and community residents who did not access MVCT. Gender-specific logistic regression models were used to describe differences in socioeconomic characteristics, HIV exposure risk, testing histories, HIV related stigma, and attitudes toward testing, between the two groups. RESULTS: MVCT clients reported greater HIV exposure risk (OR 1.20 [1.04 to 1.38] for males; OR 1.11 [1.03 to 1.19] for females). Female MVCT clients were more likely to report low household expenditures (OR 1.47 [1.04 to 2.05]), male clients reported higher rates of unstable income sources (OR 1.99 [1.22 to 3.24]). First-time testers were more likely than non-testers to cite distance to testing sites as a reason for not having previously tested (OR 2.17 [1.05 to 4.48] for males; OR 5.95 [2.85 to 12.45] for females). HIV-related stigma, fears of testing or test disclosure, and not being able to leave work were strongly associated with non-participation in MVCT (ORs from 0.11 to 0.84). CONCLUSIONS: MVCT attracted clients with increased exposure risk and fewer economic resources; HIV related stigma and testing-related fears remained barriers to testing. MVCT did not disproportionately attract either first-time or frequent repeat testers. Educational campaigns to reduce stigma and fears of testing could improve the effectiveness of MVCT in attracting new and high-risk populations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Positive skin prick tests (SPT) for food allergens and specific IgE (sIgE) in serum indicate sensitization but do not enable distinction between sensitized but tolerant and clinically allergic patients. OBJECTIVE: Herein, we evaluate the clinical relevance of basophil activation tests (BATs) for peanut or egg allergy diagnosis. METHODS: Thirty-two peanut-allergic, 14 peanut-sensitized (sIgE(+) and/or SPT(+) to peanuts) but tolerant children and 29 controls with no history of an adverse reaction to peanuts were included. Similarly, 31 egg-allergic, 14 egg-sensitized children (sIgE(+) and/or SPT(+) to egg white) and 22 controls were studied. Flow cytometric analysis of CD63 expression or CD203c upregulation on basophils and the production of leukotrienes (LT) were performed in response to an in vitro crude peanut extract or ovalbumin (OVA) challenge. RESULTS: After in vitro peanut challenge, the basophils from peanut-allergic children showed significantly higher levels of activation than those from controls (P<0.001). After OVA challenge, a similar distinction (P<0.001) was observed between egg-allergics and controls. Interestingly, the majority of egg- or peanut-sensitized children failed to activate basophils, respectively, in response to OVA and peanut challenge. The sensitivity of the CD63, CD203c and LT assay was 86.7%, 89.5% and 76.0% with a specificity of 94.1%, 97.1% and 94.6% for peanut allergy diagnosis. The corresponding performances of BATs applied to egg allergy diagnosis were 88.9%, 62.5% and 77.8% for the sensitivity and 100%, 96.4% and 96.4% for the specificity. CONCLUSION: Neither conventional tests nor BATs are sensitive and specific enough to predict food allergy accurately. However, BATs may helpfully complete conventional tests, especially SPT, allowing improved discrimination between allergic and non-allergic individuals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Four non-destructive tests for determining the length of fatigue cracks within the solder joints of a 2512 surface mount resistor are investigated. The sensitivity of the tests is obtained using finite element analysis with some experimental validation. Three of the tests are mechanically based and one is thermally based. The mechanical tests all operate by applying different loads to the PCB and monitoring the strain response at the top of the resistor. The thermal test operates by applying a heat source underneath the PCB, and monitoring the temperature response at the top of the resistor. From the modelling work done, two of these tests have shown to be sensitive to cracks. Some experimental results are presented but further work is required to fully validate the simulation results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents both modelling and experimental test data to characterise the performance of four non-destructive tests. The focus is on determining the presence and rough magnitude of thermal fatigue cracks within the solder joints for a surface mount resistor on a strip of FR4 PCB. The tests all operate by applying mechanical loads to the PCB and monitoring the strain response at the top of the resistor. The modelling results show that of the four tests investigated, three are sensitive to the presence of a crack in the joint and its magnitude. Hence these tests show promise in being able to detect cracking caused by accelerated testing. The experimental data supports these results although more validation is required.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To help design an environment in which professionals without legal training can make effective use of public sector legal information on planning and the environment - for Add-Wijzer, a European e-government project - we evaluated their perceptions of usefulness and usability. In concurrent think-aloud usability tests, lawyers and non-lawyers carried out information retrieval tasks on a range of online legal databases. We found that non-lawyers reported twice as many difficulties as those with legal training (p = 0.001), that the number of difficulties and the choice of database affected successful completion, and that the non-lawyers had surprisingly few problems understanding legal terminology. Instead, they had more problems understanding the syntactical structure of legal documents and collections. The results support the constraint attunement hypothesis (CAH) of the effects of expertise on information retrieval, with implications for the design of systems to support the effective understanding and use of information.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pregnancy is characterized by a state of heightened coagulation, which is exacerbated in pathological conditions such as pre-eclampsia (PET). PET is further associated with abnormal maternal inflammation and increased circulating microparticles (MP); however, a mechanistic link between these pathological features has never been established. It is proposed in this thesis that abnormal maternal inflammation is causally linked to pro-coagulant trophoblast MP shedding via a mechanism mediated by the pro-inflammatory cytokine tumour necrosis factor alpha (TNF), thereby contributing to maternal coagulopathies associated with PET. Using thromboelastography (TEG) and standard laboratory tests, haemostatic function was evaluated in PET and normotensive subjects at delivery and post-partum. Furthermore, the effects of the menstrual cycle and oral contraceptive (OC) use on haemostatic function were assessed in non-pregnant subjects in order to understand their influence on post-partum haemostasis. Plasma TNF and pro-coagulant MP levels were evaluated in the pregnant subjects. Using chorionic villi explants from human term placentas, MPs were quantified after TNF administration. The pro-coagulant potential of placental MPs was evaluated by TEG by spiking whole-blood with medium containing MPs from chorionic villi. TEG identified increased whole-blood coagulability in PET subjects at delivery, demonstrating its increased sensitivity over standard laboratory tests at identifying haemostatic alterations associated with PET. Haemostatic alterations were normalized by six weeks post-partum. TEG also identified cyclic haemostatic variations associated with OC use. Chorionic villi treated with TNF (1 ng/ml) shed significantly more MPs than untreated placentas. MPs from chorionic villi increased the coagulability of whole-blood. Together, results provide evidence supporting the concept that abnormal maternal inflammation is causally linked to the development of maternal coagulopathies in pregnancy complications. Moreover, TEG may be superior to standard laboratory tests in evaluating haemostasis in pregnant and non-pregnant subjects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background-Asthma, post-nasal drip syndrome (PNDS), and gastrooesophageal reflux (GOR) account for many cases of chronic non-productive cough (CNPC). Each may simultaneously contribute to cough even when clinically silent, and failure to recognise their contribution may lead to unsuccessful treatment.

Methods—Patients (all lifetime non-smokers with normal chest radiographs and spirometric measurements) referred with CNPC persisting for more than three weeks as their sole respiratory symptom underwent histamine challenge, home peak flow measurements, ear, nose and throat (ENT) examination, sinus CT scanning, and 24 hour oesophageal pH monitoring. Treatment was prescribed on the basis of diagnoses informed by investigation results.

RESULTS—Forty three patients (29 women) of mean age 47.5 years (range 18-77) and mean cough duration 67 months (range 2-240) were evaluated. On the basis of a successful response to treatment, a cause for the cough was identified in 35 patients (82%) as follows: cough variant asthma (CVA) (10 cases), PNDS (9 cases), GOR (8cases), and dual aetiologies (8 cases). Histamine challenge correctly predicted CVA in 15 of 17 (88%) positive tests. ENT examination and sinus CT scans each had low positive predictive values for PNDS (10 of 16 (63%) and 12 of 18 (67%) positive cases, respectively), suggesting that upper airways disease frequently co-exists but does not always contribute to cough. When negative, histamine challenge and 24 hour oesophageal pH monitoring effectively ruled out CVA and GOR, respectively, as a cause for cough.

CONCLUSION—This comprehensive approach aids the accurate direction of treatment and, while CVA, PNDS and GOR remain the most important causes of CNPC to consider, a group with no identifiable aetiology remains.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper examines the finite sample properties of three testing regimes for the null hypothesis of a panel unit root against stationary alternatives in the presence of cross-sectional correlation. The regimes of Bai and Ng (2004), Moon and Perron (2004) and Pesaran (2007) are assessed in the presence of multiple factors and also other non-standard situations. The behaviour of some information criteria used to determine the number of factors in a panel is examined and new information criteria with improved properties in small-N panels proposed. An application to the efficient markets hypothesis is also provided. The null hypothesis of a panel random walk is not rejected by any of the tests, supporting the efficient markets hypothesis in the financial services sector of the Australian Stock Exchange.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Punching failure is the common failure mode in concrete bridge deck slabs when these structural components are subjected to local patch loads, such as tyre loads. Past research has shown that reinforced concrete slabs in girder–slab type bridges have a load-carrying capacity far greater than the ultimate static loads predicted by traditional design methods, because of the presence of compressive membrane action. However, due to the instability problems from punching failure, it is difficult to predict ultimate capacities accurately in numerical analyses. In order to overcome the instability problems, this paper establishes an efficient non-linear finite-element analysis using the commercial finite-element package Abaqus. In the non-linear finite-element analysis, stabilisation methods were adopted and failure criteria were established to predict the ultimate punching behaviour of deck slabs in composite steel–concrete bridges. The proposed non-linear finite-element analysis predictions showed a good correlation on punching capacities with experimental tests.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents experimental tests carried out on steel fibre reinforced concrete samples, including mechanical tests as well as non-destructive technique (electrical resistivity) and non destructive technique on cores (X-ray). Electrical resistivity measurements are done as a blind test, to characterise the electrical anisotropy and deduce the distribution and the orientation of fibres. These results are compared to X-ray imaging to check the quality of the non destructive evaluation. Then, flexural and compressive strength are measured on specimens to assess the influence of fibre distribution on the concrete properties.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A full-scale seven-storey in-situ advanced reinforced concrete building frame was constructed in the Building Research Establishment's Cardington laboratory encompassing a range of different concrete mixes and construction techniques. This provided an opportunity to use in-situ non-destructive test methods, namely Lok and CAPO tests, on a systematic basis during the construction of the building. They were used in conjunction with both standard and temperature-matched cube specimens to assess their practicality and their individual capabilities under field conditions. Results have been analysed and presented to enable comparisons of the performance of the individual test methods employed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The results of 82 web crippling tests are presented, with 20 tests conducted on channel sections without web openings and 62 tests conducted on channel sections with web openings. The tests consider both end-two-flange and interior-two-flange loading conditions. In the case of the tests with web openings, the hole was located directly under the concentrated load. The concentrated load was applied through bearing plates; the effect of different bearing lengths is investigated. In addition, the cases of both flanges fastened and unfastened to the support is considered. A non-linear elasto-plastic finite element model is described, and the results compared against the laboratory test results; a good agreement was obtained in terms of both strength and failure modes.