974 resultados para THORACIC SURGERY


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Valvuloplasty of the aortic valve is currently used in selected patients for severe calcified aortic valve disease, but clinical effectiveness is low and complication rate remains high. In this study, the total particle load after valvuloplasty and the embolization risk of calcific debris into the coronary arteries was analyzed in an in vitro model.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To measure surrogate markers of coagulation activation as well as of the systemic inflammatory response in patients undergoing primary elective coronary artery bypass grafting (CABG) using either the so-called Smart suction device or a continuous autotransfusion system (C.A.T.S.®).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Graft right ventricular (RV) function is compromised directly posttransplant, especially in heart transplantation (HTx) recipients with pretransplant pulmonary hypertension (PH). Graft RV size and systolic function, and the effect of the recipient's pulmonary haemodynamics on the graft extracellular matrix are not well characterised in the patients long-term after HTx.

Relevância:

60.00% 60.00%

Publicador:

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The use of radial artery conduits in coronary artery bypass grafting (CABG) surgery is associated with improved long-term patency and patient survival rates as compared with saphenous vein conduits. Despite increasing popularity, relative incidence of local harvest-site complications and subjective perception of adverse long-term sequelae remain poorly described.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Prosthesis-patient mismatch (PPM) remains a controversial issue with the most recent stented biological valves. We analyzed the incidence of PPM after implantation of the Carpentier-Edwards Perimount Magna Ease aortic valve (PMEAV) bioprosthesis and assessed the early clinical outcome. Two hundred and seventy consecutive patients who received a PMEAV bioprosthesis between January 2007 and July 2008 were analyzed. Pre-, peri- and postoperative data were assessed and echocardiographic as well as clinical follow-up was performed. Mean age was 72+/-9 years, 168 (62.2%) were males. Fifty-seven patients (21.1%) were below 65 years of age. Absence of PPM, corresponding to an indexed effective orifice area >0.85 cm(2)/m(2), was 99.5%. Observed in-hospital mortality was 2.2% (six patients), with a predicted mortality according to the additive EuroSCORE of 7.6+/-3.1%. At echocardiographic assessment after a mean follow-up period of 150+/-91 days, mean transvalvular gradient was 11.8+/-4.8 mmHg (all valve sizes). No paravalvular leakage was seen. Nine patients died during follow-up. The Carpentier-Edwards PMEAV bioprosthesis shows excellent hemodynamic performance. This valve can be implanted in all sizes with an incidence of severe PPM below 0.5%.

Relevância:

60.00% 60.00%

Publicador:

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Gerbode's defect, a left ventricular-to-right atrial communication, with involvement of the tricuspid valve acquired after bacterial endocarditis can be challenging to repair. We report a modified technique for a shunt closure and reconstruction of the tricuspid valve using a plicated bovine pericardial patch. Combining such a repair with a left ventricular patch resulted in a complete defect closure and competent tricuspid valve without regurgitation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this study was to assess the efficacy and midterm results of endovascular treatment of acute, complicated type B aortic dissection.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The study aims to identify risk constellations for symptomatic spinal cord malperfusion in patients undergoing extensive stent-graft coverage of the thoracic aorta.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The PAS-Port system (Cardica, Inc, Redwood City, CA) was used routinely for patients undergoing coronary surgery with at least one venous graft. Graft patency and clinical results were evaluated, respectively, at 6 months and 5 years after surgery.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Transcatheter aortic valve implantation (TAVI) is an alternative to surgery for high-risk patients with severe aortic valve stenosis. Periprocedural stroke is reported at an incidence up to 10%. Magnetic resonance imaging studies have identified new onset of clinically silent ischaemic cerebral lesions more frequently (68-84%). So far, few data are available about cerebral embolism during TAVI. The aim of this study was to determine the frequency of high-intensity transient signals (HITS) and to explore differences in the HITS pattern between transfemoral and transapical access and between self-expanding (SE) and balloon-expandable (BE) deployment technique.

Relevância:

60.00% 60.00%

Publicador: