898 resultados para Surgical site infection
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This case report presents details of a new surgical technique for mandibular ridge sagittal osteotomy and expansion associated to immediate dental implants in atrophic ridges. The bone atrophies represents a challenge for the surgeons that intends to modify this situation. In the past, the only viable option was the onlay bone graft. However, the bone graft requests a second surgical site that certainly increases the postoperative morbidity, without mentioning the longer treatment time required. The sagittal osteotomy of the alveolar crest represents a faster option, because it eliminates the time requested for bone graft integration, providing rehabilitation of edentulous areas with thin alveolar crests that otherwise would need additi onal surgical procedures for a satisfactory result. The authors report a clinical case in which this technique was used with the installation of a Bicon dental implant in the same surgical time, showing all the steps for this single-tooth rehabilitation.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
Pós-graduação em Doenças Tropicais - FMB
Resumo:
Thrombosis of tunneled central venous catheters (CVC) in hemodialysis (HD) patients is common and it can lead to the elimination of vascular sites. This study aimed to evaluate the incidence of thrombotic obstruction of tunneled CVC in HD patients and the efficacy of occlusion treatment with alteplase use, and identify factors associated with thrombotic occlusion. It was a prospective cohort study performed in two centers which evaluated the diagnosis and treatment of thrombotic occlusion of CVC in HD patients for 24 consecutive months. The catheter occlusion was defined as the difficulty infusing or withdrawing fluid from their paths. Alteplase dose was infused to fill the lumen of the occluded catheter and remained for 50 min. As there was no obstruction of the catheter, the procedure was repeated. Three hundred and thirty-nine CVC in 247 patients were evaluated and followed, totalling 67 244 CVC-days. One hundred fifty-seven patients had only one CVC, 88 patients had two CVC during the study, and two patients had three CVC. The median age was 58 (47–66) years, patients were predominantly men (54%), with diabetic nephropathy as the main cause of chronic kidney disease (44%), the internal jugular vein as the main site of implantation (82%), and duration of dialysis before CVC implantation of 119 (41.5 to 585.5) days. Eight hundred and fifteen occlusion episodes were diagnosed (12 episodes/1000 CVC-days), with primary success with alteplase in 596 episodes (77%) and secondary in 81 cases (10%). In 99 episodes (13%), success was not achieved after the second dose of alteplase. Two hundred and thirty CVC were removed during the study and the removal causes were arteriovenous fistula use in 88 patients (38.3%), infectious and mechanical complications in 89 (38.7%) and 21 (9.1%), respectively, and others (transplantation, transfer, or death) in 32 patients (13.9%). Adverse effects were also not observed. In the multivariate analysis, we identified the greatest number of days with CVC (OR = 1.02, CI = 1.01–1.04, P = 0.004), the presence of diabetes (OR = 1.560, CI = 1.351–1.894, P = 0.015), and exit site infection (ESI) (OR = 1.567 CI = 1347–1926, P = 0.023) as factors associated with obstruction. Thrombotic occlusion showed frequent mechanical complication in CVC of HD patients. We observed 12 episodes of obstruction per 1000 CVC-days, with a high success rate after alteplase use (87%). In the multivariate analysis, the time with CVC, the presence of diabetes, and ESI were identified as variables associated with thrombotic obstruction.
Resumo:
The elimination of all external incisions is an important step in reducing the invasiveness of surgical procedures. Natural Orifice Translumenal Endoscopic Surgery (NOTES) is an incision-less surgery and provides explicit benefits such as reducing patient trauma and shortening recovery time. However, technological difficulties impede the widespread utilization of the NOTES method. A novel robotic tool has been developed, which makes NOTES procedures feasible by using multiple interchangeable tool tips. The robotic tool has the capability of entering the body cavity through an orifice or a single incision using a flexible articulated positioning mechanism and once inserted is not constrained by incisions, allowing for visualization and manipulations throughout the cavity. Multiple interchangeable tool tips of the robotic device initially consist of three end effectors: a grasper, scissors, and an atraumatic Babcock clamp. The tool changer is capable of selecting and switching between the three tools depending on the surgical task using a miniature mechanism driven by micro-motors. The robotic tool is remotely controlled through a joystick and computer interface. In this thesis, the following aspects of this robotic tool will be detailed. The first-generation robot is designed as a conceptual model for implementing a novel mechanism of switching, advancing, and controlling the tool tips using two micro-motors. It is believed that this mechanism achieves a reduction in cumbersome instrument exchanges and can reduce overall procedure time and the risk of inadvertent tissue trauma during exchanges with a natural orifice approach. Also, placing actuators directly at the surgical site enables the robot to generate sufficient force to operate effectively. Mounting the multifunctional robot on the distal end of an articulating tube provides freedom from restriction on the robot kinematics and helps solve some of the difficulties otherwise faced during surgery using NOTES or related approaches. The second-generation multifunctional robot is then introduced in which the overall size is reduced and two arms provide 2 additional degrees of freedom, resulting in feasibility of insertion through the esophagus and increased dexterity. Improvements are necessary in future iterations of the multifunctional robot; however, the work presented is a proof of concept for NOTES robots capable of abdominal surgical interventions.
Resumo:
Objective: To analyze the association between maternal obesity and postnatal infectious complications in high-risk pregnancies. Methods: Prospective study from August 2009 through August 2010 with the following inclusion criteria: women up to the 5th postpartum day; age L 18 years; high-risk pregnancy; singleton pregnancy with live fetus at labor onset; delivery at the institution; maternal weight measured on day of delivery. The nutritional status in late pregnancy was assessed by the body mass index (BMI), with the application of the Atalah et al. curve. Patients were graded as underweight, adequate weight, overweight, or obese. Postpartum complications investigated during the hospital stay and 30 days post-discharge were: surgical wound infection and/or secretion, urinary infection, postpartum infection, fever, hospitalization, antibiotic use, and composite morbidity (at least one of the complications mentioned). Results: 374 puerperal women were included, graded according to the final BMI as: underweight (n = 54, 14.4%); adequate weight (n = 126, 33.7%); overweight (n = 105, 28.1%); and obese (n = 89, 23.8%). Maternal obesity was shown to have a significant association with the following postpartum complications: surgical wound infection (16.7%, p = 0.042), urinary infection (9.0%, p = 0.004), antibiotic use (12.3%, p < 0.001), and composite morbidity (25.6%, p = 0.016). By applying the logistic regression model, obesity in late pregnancy was found to be an independent variable regardless of the composite morbidity predicted (OR: 2.09; 95% CI: 1.15-3.80, p = 0.015). Conclusion: Maternal obesity during late pregnancy in high-risk patients is independently associated with postpartum infectious complications, which demonstrates the need for a closer follow-up of maternal weight gain in these pregnancies.
Resumo:
Introduction: Nurse understaffing is frequently hypothesized as a potential risk factor for healthcare-associated infections (HAI). This study aimed to evaluate the role of nursing workload in the occurrence of HAI, using Nursing Activities Score (NAS). Methods: This prospective cohort study enrolled all patients admitted to 3 Medical ICUs and one step-down unit during 3 months (2009). Patients were followed-up until HAI, discharge or death. Information was obtained from direct daily observation of medical and nursing rounds, chart review and monitoring of laboratory system. Nursing workload was determined using NAS. Non-compliance to the nurses' patient care plans (NPC) was identified. Demographic data, clinical severity, invasive procedures, hospital interventions, and the occurrence of other adverse events were also recorded. Patients who developed HAI were compared with those who did not. Results: 195 patients were included and 43 (22%) developed HAI: 16 pneumonia, 12 urinary-tract, 8 bloodstream, 2 surgical site, 2 other respiratory infections and 3 other. Average NAS and average proportion of non compliance with NPC were significantly higher in HAI patients. They were also more likely to suffer other adverse events. Only excessive nursing workload (OR: 11.41; p: 0.019) and severity of patient's clinical condition (OR: 1.13; p: 0.015) remained as risk factors to HAI. Conclusions: Excessive nursing workload was the main risk factor for HAI, when evaluated together with other invasive devices except mechanical ventilation. To our knowledge, this study is the first to evaluate prospectively the nursing workload as a potential risk factor for HAI, using NAS.
Resumo:
The aim of this study was to evaluate the microbial growth on single-use vitrectomy probes reprocessed in healthcare practice. We investigated nine vitrectomy probes that had been reused and reprocessed using different methods. The samples were sectioned, individually, in portions of 3.5 cm, totaling 979 sampling units (extensions, connectors and vitrectomy cutters), which were inoculated in culture medium and incubated at 37 C for 14 days. The results showed microbial growth on 57 (5.8%) sample units, 25 of which had been sterilized using ethylene oxide, 16 by hydrogen peroxide plasma, and 16 by low-temperature steam and formaldehyde. Seventeen microbial species were identified. The most prevalent were: Micrococcus spp., coagulase-negative Staphylococcus, Pseudomonas spp., and Bacillus subtilis. The reuse of single-use vitrectomy probes was shown to be unsafe, therefore this practice is not recommended.
Resumo:
The aims of this study were to evaluate the influence of cardiopulmonary bypass (CPB) on the plasma concentrations and pharmacokinetics of cefuroxime and to assess whether the cefuroxime dose regimen (a 1.5 g dose, followed by 750 mg every 6 h for 24 h) is adequate for cardiac surgery antibiotic prophylaxis. A prospective, controlled, observational study compared patients undergoing coronary surgery with CPB (CPB group, n = 10) or off-pump surgery (off-pump group, n = 9). After each cefuroxime dose, blood samples were sequentially collected and analysed using high-efficiency chromatography. For demographic data and pharmacokinetic parameters, the authors used Fisher's exact test for nominal variables and Student's t-test and the Mann-Whitney U-test for parametric and non-parametric variables, respectively. Plasma concentrations were compared using ANOVA, and the percentage of patients with a remaining plasma concentration of > 16 mg/l within 6 h after each bolus was quantified in tabular form. After each cefuroxime bolus was administered, both groups presented a significant decrease in plasma concentration over time (P < 0.001), without differences between the groups. The mean CPB time of 59.7 +/- 21.1 min did not change cefuroxime plasma concentrations or pharmacokinetics. The mean clearance +/- SD (ml/kg/min) and median elimination half-life (h) of the CPB group versus the off-pump group were 1.7 +/- 0.7 versus 1.6 +/- 0.6 (P = 0.67), respectively, and 2.2 versus 2.3 (P = 0.49), respectively. Up to 3 h following the first bolus of 1.5 g, but not after 6 h, all patients had plasma concentrations > 16 mg/l (CPB group = 20% and off-pump group = 44%). However, after all 750 mg boluses were administered, concentrations < 16 mg/dl were reached within 3 h. CPB does not influence cefuroxime plasma concentrations. The dosing regimen is adequate for the intraoperative period, but in the immediate postoperative period, it requires further review.
Resumo:
O objetivo deste estudo foi avaliar o crescimento microbiano em sondas para vitrectomia de uso único, reprocessadas na prática assistencial. Foram investigadas nove sondas reusadas e reprocessadas por diferentes métodos. As sondas foram segmentadas, individualmente, em porções de 3,5 cm, totalizando em 979 unidades amostrais (extensões, conectores e ponteiras) inoculadas em meio de cultura e incubadas a 37ºC, por 14 dias. Os resultados mostraram crescimento microbiano em 57 (5,8%) unidades amostrais, das quais, 25 foram esterilizadas por Óxido de Etileno, 16 por Plasma de Peróxido de Hidrogênio e 16 por Vapor à Baixa Temperatura e Formaldeído. Foram identificadas 17 espécies microbianas, sendo as mais prevalentes o Micrococcus spp., Staphylococcus coagulase negativa, Pseudomonas spp. e Bacillus subtilis. O reuso de sondas de uso único para vitrectomia não se mostrou seguro, portanto tal prática não é recomendada.
Resumo:
Image overlay projection is a form of augmented reality that allows surgeons to view underlying anatomical structures directly on the patient surface. It improves intuitiveness of computer-aided surgery by removing the need for sight diversion between the patient and a display screen and has been reported to assist in 3-D understanding of anatomical structures and the identification of target and critical structures. Challenges in the development of image overlay technologies for surgery remain in the projection setup. Calibration, patient registration, view direction, and projection obstruction remain unsolved limitations to image overlay techniques. In this paper, we propose a novel, portable, and handheld-navigated image overlay device based on miniature laser projection technology that allows images of 3-D patient-specific models to be projected directly onto the organ surface intraoperatively without the need for intrusive hardware around the surgical site. The device can be integrated into a navigation system, thereby exploiting existing patient registration and model generation solutions. The position of the device is tracked by the navigation system’s position sensor and used to project geometrically correct images from any position within the workspace of the navigation system. The projector was calibrated using modified camera calibration techniques and images for projection are rendered using a virtual camera defined by the projectors extrinsic parameters. Verification of the device’s projection accuracy concluded a mean projection error of 1.3 mm. Visibility testing of the projection performed on pig liver tissue found the device suitable for the display of anatomical structures on the organ surface. The feasibility of use within the surgical workflow was assessed during open liver surgery. We show that the device could be quickly and unobtrusively deployed within the sterile environment.
Resumo:
OBJECTIVE: To investigate causes of the lack of clinical improvement after thoracolumbar disc surgery. STUDY DESIGN: Case-control magnetic resonance imaging (MRI) study. ANIMALS: Chondrodystrophic dogs with acute thoracolumbar disc disease treated by hemilaminectomy: 10 that had no short-term clinical improvement and 12 with "normal" clinical improvement. METHODS: Dogs that had surgery for treatment of intervertebral disc extrusion (2003-2008) where thoracolumbar disc disease was confirmed by MRI were evaluated to identify dogs that had lack of clinical improvement after surgery. Ten dogs with delayed recovery or clinical deterioration were reexamined with MRI and compared with 12 dogs with normal recovery and MRI reexamination after 6 weeks (control group). RESULTS: Of 173 dogs, 10 (5.8%) had clinical deterioration within 1-10 days after surgery. In 8 dogs, residual spinal cord compression was identified on MRI. Bleeding was present in 1 dog. In 3 dogs, the cause was an incorrect approach and insufficient disc material removal. In 3 dogs, recurrence occurred at the surgical site. In 1 dog, the centrally located extruded material was shifted to the contralateral side during surgery. These 8 dogs had repeat surgery and recovery was uneventful. In 2 dogs, deterioration could not be associated with a compressive disc lesion. Hemorrhagic myelomalacia was confirmed by pathologic examination in 1 dog. The other dog recovered after 6 months of conservative management. CONCLUSION: Delayed postsurgical recovery or deterioration is commonly associated with newly developed and/or remaining compressive disc lesion. CLINICAL RELEVANCE: We recommend early MRI reexamination to assess the postsurgical spinal canal and cord, and to plan further therapeutic measures in chondrodystrophic dogs with delayed recovery after decompressive hemilaminectomy for thoracolumbar disc disease.
Resumo:
Postoperative fascial dehiscence and open abdomen are severe postoperative complications and are associated with surgical site infections, fistula, and hernia formation at long-term follow-up. This study was designed to investigate whether intraperitoneal implantation of a composite prosthetic mesh is feasible and safe.