127 resultados para Subterráneo


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Leachates are effluent produced by decomposition of solid waste, they have complex composition and can be highly toxic. Therefore such percolated liquid should be collected and treated properly to avoid environmental contamination of soil and of water bodies. The objective of this study was to evaluate the toxicity through ecotoxicological tests with Ceriodaphnia dubia (Cladocera - Crustacea) of percolated liquids generated in two different systems of municipal solid waste (MSW) disposal in the city of Natal/ RN: A Sanitary Landfill in the Metropolitan Region of Natal/ RN, and in a dump off area. Furthermore, it was evaluated the possible contamination of the underground water of the dump off area. Two monthly samples were taken at four points between the months of May/2009 and January/2010. The Point "A" corresponds to the end of the pond leachate treatment in ASRMN; The Point "B" corresponds to a containment pond at the dump. The Point "C" is an area near one of the cells of the dump off area where the leachate outcrops; The Point "D" stands for an underground water well at the area. The last point, called "E" was sampled only once and corresponds to the slurry produced by temporary accumulation of solid waste in the open area of the dump. The ecotoxicological tests, acute and chronic, followed the ABNT 13373/2005 rules, with some modifications. The samples were characterized by measuring the pH number, the dissolved oxygen (DO), the salinity, BOD5, COD, Cd, Cu, Pb, Cr, Fe, Mg, Ni, and Zn. At Point A, the average number of EC50-48h ranged between 1.0% and 2.77% (v/v), showing a high toxicity of the leachate to C.dubia in all months. To this point, positive correlations were found between the EC50- 48 with precipitation. Negative correlations were found between the EC50- 48h with salinity. At point B there was no response of the acute exposure of organisms to the test samples. At point C the EC50-48h ranged from 17.68% to 35.36% in just two months of the five ones analyzed, not correlated meaning. Point D, the EC50-48h level ranged between 12.31% and 71.27%, showed a negative correlation with, only, precipitation. Although it was observed toxicity of underground water in the Landfill Area, there was no evidence of water contamination by leachate, however, due to the toxic character of this water, additional tests should be conducted to confirm the quality of water that is used for human supply. At point E there was no acute toxicity. These results support the dangers of inappropriate disposal of MSW to water bodies due to the high toxicity of the leachate produced highlighting the necessity of places of safe confinement and a treatment system more effective to it

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La Compañía Metropolitano Alfonso XIII llevó a cabo, a principios del siglo XX, la empresa de dotar a la capital española de un ferrocarril subterráneo a la altura de otras ciudades europeas: el Metro de Madrid. Del proyecto original de cuatro líneas, la 3 y la 4 se construyeron e inauguraron en plena guerra civil y en los primeros años del franquismo (1936-1945). Esta última fecha es significativa, puesto que poco después de abierta al público la línea 4 (que convertía al metropolitano por fin en una red mallada), murió su primer arquitecto oficial, Antonio Palacios Ramilo, relevante proyectista de la primera mitad del siglo XX, responsable de emblemáticos edificios del centro de la capital (Círculo de Bellas Artes, Palacio de Correos, Banco Español del Río de la Plata...). En su calidad de arquitecto oficial de la Compañía Metropolitano Alfonso XIII, diseñó no sólo las estaciones, bocas y templetes del metro de Madrid, sino también toda una serie de edificios auxiliares entre los que destacan las centrales y subestaciones eléctricas. Explicaremos la evolución de la red de metro en los comienzos del franquismo y analizaremos la arquitectura subterránea que Palacios diseñó para el ferrocarril metropolitano, centrándonos en las llamadas líneas "de los barrios bajos" y "de los bulevares", la planificación de la estación de Sol como centro neurálgico de la red y en cómo los modelos de barandillas, accesos y decoración interior que ideó Antonio Palacios se siguieron utilizando hasta mucho después de su muerte, si bien otros elementos no subsistieron al paso del tiempo y la llamada "modernización" del Metro que se llevó a cabo en los años 60 y 70. También estudiaremos el modo de intervención de Palacios en la arquitectura industrial respecto al resto de su obra y haremos especial hincapié en el estado en que se encuentra actualmente este patrimonio, distinguiendo entre los casos en los que ha habido una intervención restauradora (Nave de Motores en Pacífico, Estación de Chamberí), los que están en desuso (subestaciones de Quevedo y Salamanca...) y los elementos que ya han desaparecido (templetes de Sol y Gran Vía).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Among the potentially polluting economic activities that compromise the quality of groundwater are the gas stations. The city of Natal has about 120 gas stations, of which only has an environmental license for operation. Discontinuities in the offices were notified by the Public Ministry of Rio Grande do Norte to carry out the environmental adaptations, among which is the investigation of environmental liabilities. The preliminary and confirmatory stages of this investigation consisted in the evaluation of soil gas surveys with two confirmatory chemical analysis of BTEX, PAH and TPH. To get a good evaluation and interpretation of results obtained in the field, it became necessary three-dimensional representation of them. We used a CAD software to graph the equipment installed in a retail service station fuel in Natal, as well as the plumes of contamination by volatile organic compounds. The tool was concluded that contamination is not located in the current system of underground storage of fuel development, but reflects the historical past in which tanks were removed not tight gasoline and diesel

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Activities that have fuel subterranean storage system are considered potentially polluting fuels by CONAMA Resolution 273, due to the possibility of leak, outpouring and overflow of fuel into the ground. Being even more worrying when contaminate groundwater for public supply, as the case of Natal City. For this reason, the Public Ministry/RN, in partnership with UFRN, developed the project environmental suitability of Gas stations in Natal, of which 36% showed evidence of contamination. This paper describes the four stages of the management of contaminated areas: preliminary assessment of environmental liabilities, detailed confirmatory investigation of the contamination, risk analysis to human health (RBCA), as well as the remediation plan of degraded areas. Therefore it is presented a case study. For the area investigated has been proposed a mathematical method to estimate the volume of LNAPL by a free CAD software (ScketchUp) and compare it with the partition method for grid area. Were also performed 3D graphics designs of feathers contamination. Research results showed that passive benzene contamination in groundwater was 2791.77 μg/L, when the maximum allowed by CONAMA Resolution 420 is 5 μg/L which is the potability standards. The individual and cumulative risks were calculated from 4.4 x10-3, both above the limits of 1.0 x10-5 or by RBCA 1.0 x10-6 by the Public Ministry/RN. Corrective action points that remediation of dissolved phase benzene is expected to reach a concentration of 25 μg/L, based on carcinogenic risk for ingestion of groundwater by residents residential, diverging legislation. According to the proposed model, the volume of LNAPL using the ScketchUp was 17.59 m3, while by the grid partitioning method was 14.02 m3. Because of the low recovery, the expected removal of LNAPL is 11 years, if the multiphase extraction system installed in the enterprise is not optimized

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Leachates are effluent produced by decomposition of solid waste, they have complex composition and can be highly toxic. Therefore such percolated liquid should be collected and treated properly to avoid environmental contamination of soil and of water bodies. The objective of this study was to evaluate the toxicity through ecotoxicological tests with Ceriodaphnia dubia (Cladocera - Crustacea) of percolated liquids generated in two different systems of municipal solid waste (MSW) disposal in the city of Natal/ RN: A Sanitary Landfill in the Metropolitan Region of Natal/ RN, and in a dump off area. Furthermore, it was evaluated the possible contamination of the underground water of the dump off area. Two monthly samples were taken at four points between the months of May/2009 and January/2010. The Point "A" corresponds to the end of the pond leachate treatment in ASRMN; The Point "B" corresponds to a containment pond at the dump. The Point "C" is an area near one of the cells of the dump off area where the leachate outcrops; The Point "D" stands for an underground water well at the area. The last point, called "E" was sampled only once and corresponds to the slurry produced by temporary accumulation of solid waste in the open area of the dump. The ecotoxicological tests, acute and chronic, followed the ABNT 13373/2005 rules, with some modifications. The samples were characterized by measuring the pH number, the dissolved oxygen (DO), the salinity, BOD5, COD, Cd, Cu, Pb, Cr, Fe, Mg, Ni, and Zn. At Point A, the average number of EC50-48h ranged between 1.0% and 2.77% (v/v), showing a high toxicity of the leachate to C.dubia in all months. To this point, positive correlations were found between the EC50- 48 with precipitation. Negative correlations were found between the EC50- 48h with salinity. At point B there was no response of the acute exposure of organisms to the test samples. At point C the EC50-48h ranged from 17.68% to 35.36% in just two months of the five ones analyzed, not correlated meaning. Point D, the EC50-48h level ranged between 12.31% and 71.27%, showed a negative correlation with, only, precipitation. Although it was observed toxicity of underground water in the Landfill Area, there was no evidence of water contamination by leachate, however, due to the toxic character of this water, additional tests should be conducted to confirm the quality of water that is used for human supply. At point E there was no acute toxicity. These results support the dangers of inappropriate disposal of MSW to water bodies due to the high toxicity of the leachate produced highlighting the necessity of places of safe confinement and a treatment system more effective to it

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El objetivo de este paper es analizar la relevancia que posee para la comprensión de Helena el himno a las Sirenas y a Perséfone, deidades que a simple vista no tienen relación con el mito de la tragedia. Consideramos que la inclusión de este himno no es arbitraria ni evidencia un descuido del poeta, por el contrario, permite la interpretación de Helena a partir de las doctrinas órficas y mistéricas vigentes en el siglo V (Ässael 2012). En Eleusis, Perséfone junto con su madre Deméter preside los misterios que prometen bendiciones a los iniciados tanto durante su vida como después de la muerte. En la tradición órfica, específicamente en las laminillas de oro, la figura de Perséfone cobra mayor importancia, ya que es quien decide sobre la suerte del iniciado después de su muerte. Y en la colección de himnos órficos, ligados a cultos mistéricos (Morand 2001: 77), su presencia junto con la de Deméter, Zeus y Dioniso es central. Sin embargo, no existe evidencia de himnos cultuales ni literarios en honor a Perséfone, salvo el Himno Orfico XXIX. Además, en la tragedia, la Reina del mundo subterráneo es alabada junto a las Sirenas, diosas que en la tradición iconográfica desempeñan el rol de cantoras en el Más Allá, en la Isla de los Bienaventurados. Por este motivo consideramos que puede plantearse el análisis del himno trágico a partir de la función central que desempeñaba la mousike en los misterios en el siglo V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El objetivo de este paper es analizar la relevancia que posee para la comprensión de Helena el himno a las Sirenas y a Perséfone, deidades que a simple vista no tienen relación con el mito de la tragedia. Consideramos que la inclusión de este himno no es arbitraria ni evidencia un descuido del poeta, por el contrario, permite la interpretación de Helena a partir de las doctrinas órficas y mistéricas vigentes en el siglo V (Ässael 2012). En Eleusis, Perséfone junto con su madre Deméter preside los misterios que prometen bendiciones a los iniciados tanto durante su vida como después de la muerte. En la tradición órfica, específicamente en las laminillas de oro, la figura de Perséfone cobra mayor importancia, ya que es quien decide sobre la suerte del iniciado después de su muerte. Y en la colección de himnos órficos, ligados a cultos mistéricos (Morand 2001: 77), su presencia junto con la de Deméter, Zeus y Dioniso es central. Sin embargo, no existe evidencia de himnos cultuales ni literarios en honor a Perséfone, salvo el Himno Orfico XXIX. Además, en la tragedia, la Reina del mundo subterráneo es alabada junto a las Sirenas, diosas que en la tradición iconográfica desempeñan el rol de cantoras en el Más Allá, en la Isla de los Bienaventurados. Por este motivo consideramos que puede plantearse el análisis del himno trágico a partir de la función central que desempeñaba la mousike en los misterios en el siglo V.